| 1 | SOLAR ROOF TOP SYSTEM |
| 2 | Design, Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar Power Plant with Solar Panels (ALMM approved): Frame Material :Anodized Aluminum alloy Frame With Twin Wall Profile, Front Cover : High Transmission Low-Iron Tempered Glass (AR Coated), High efficency and positive power tolerance Pmax: 0/+5, Module Efficiency should be approx.18%-21%,Normal operating temperature 45\"C, Junction Box with Waterproof IP67 & MC4 Compatible and Enclosed with Bypass diodes, 100% Electroluminescence test to ensure error free Modules, Thep. temp. co-efficient of the PV module shall equal or better than -0.45%/degree C. Solar PV modules of minimum fill factor 75% to be used. Unit Production:- 4 to 5 Unit /kw /day (Actual)(1Year Avg) With 10 year Product warranty and 25 year Linear Power Warranty., Solar Inverter: MPPT Range: 80-1000 V, Max efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: <3%, Operating Tempreture Range: -25~60°C, Anti-islanding Protection: Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor Detection Integrated, Residual Current Monitoring Unit Integrated, Output Over Current Protection Integrated, Output Short Circuit Protection Integrated, Output Over Voltage Protection Integrated, Protection Degree: IP65, User Interface LCD & APP,Datalogger & Communication: GPRS / Wi-Fi, Module Mounting Structure: Seamless Box Pipe / \"C\" Channelof suitable size for rooftop solar installations with good stability agaist wind & weight load., Hot Dipped Galvanized steel coils. suitable arrangement for base plate for foundation , solar panel mounting, the structure should be suitable for carry the load of solar panel,wiring, sprinkler system etc. with necessary foundation work/wall mount, j bolt, anchor fastner etc. the nut bolt used for installtion of stucture should be (SS 304) quality. and Balane of System with necessary Swithgears (Suitabel size and protection of ACDB & DCDB), inter connecting wiring, earthing system, lightining arrester system, all liasoning work with various gov. dipartment like state nodal agency,DISCOM & CEIG is included in agency scope. (Excluding GEDA Application fees, Solar connectivity Charges, Meter connectivity Charges, Meter testing Charges.) . Solar Panel shall be min 595Wp Each or above unit with N-Type Topcon Mono crystalline Silicon Bifacial Module with 30 years Linear Performance Warranty. (D) Grid Tied Solar Power System: 26 - 50 kW (3 - phase) |
| 3 | (E) Grid Tied Solar Power System: 51 - 100 kW (3 - phase) |
| 4 | (F) Grid Tied Solar Power System: 101 - 250 kW (3 - phase) |
| 5 | Providing & erecting Automatic solar panel cleaning system for solar power projects which includes necessary plumbing work (UPVC pipes and accessories) from source of water to project site (upto 30 meters),Suitable size of sub mercible/ open well motor, necessary wiring for motor and sprinkler system with safety, timer circuit for automatically on/off the sprinkler system, necessary size oand number of nozzles/JET (minimum 1 Nozzle/Jet per module).(D) 21KW-50KW Cleaning System |
| 6 | (E) 51KW-100KW Cleaning System |
| 7 | (F) 101KW-200KW Cleaning System |
| 8 | The all inclusive comprehencive annual maintance contract cost covers yearly maintanance of solar Pv Modules, Inverter, wiring,earthing,switchgears, etc with material and labour cost including preventive maintanance.The cost covers entire installation. AMC also includes monthly site visit and inspection of project with submission of inspection and solar generation report. All parts should be replaced/repaired if found faulty within specified time. Agency has to provide necessory licening work for warranty,power,Bidirectional meter etc. (C ) 21KW-50KWSystem |
| 9 | (D) 51KW-100KWSystem |
| 10 | (E) 101KW-200KWSystem |
| 11 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenientsections,joinedwithconnectors,suspendedfrom the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.150 mm width X 50 mm depth X 1.6 mm thickness |
| 12 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 13 | 600 mm width X 50 mm depth X 2.0 mm thickness |
| 14 | 900 mm width X 75 mm depth X 2.0 mm thickness |
| 15 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables. (A) 3 1/2core 25 Sq. mm ( 16 Sq. mm 1/2 core) |
| 16 | (C) 3 1/2core 50 Sq. mm ( 25 Sq.1/2 mmcore) |
| 17 | (F) 3 1/2core 120 Sq. mm ( 70 Sq. mm 1/2 core) |
| 18 | (G) 3 1/2 core 150 Sq. mm ( 70 Sq. mm 1/2 core) |
| 19 | (H) 3 1/2core 185 Sq. mm ( 95 Sq. mm1/2 core) |
| 20 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand / SolidCopperconductor for1.1 KV. to be laidon wall with necessary clamps or in existingtrench/ pipe at road crossing or floorof followingsize of cables. (A) 4 core 2.5 Sq. mm |
| 21 | (B) 4 core 4 Sq. mm |
| 22 | (C) 4 core 6 Sq. mm |
| 23 | (F) 4 core 10 Sq. mm |
| 24 | (D)4 core 16 Sq. mm |
| 25 | (C) 4 core 25 Sq. mm |
| 26 | Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 27 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 28 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 29 | Supplying and making end termination with brass compression glandandaluminiumlugsforfollowingsizeofPVCinsulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 25 sq. mm (28mm) |
| 30 | 3½ X 50 sq. mm (35mm) |
| 31 | 3½ X 70 sq. mm (38mm) |
| 32 | 3½ X 120 sq. mm (45mm) |
| 33 | 3½ X 150 sq. mm (50mm) |
| 34 | 3½ X 185 sq. mm (57mm) |
| 35 | Solder less crimping type Copper lugs conforming to IS suitable for cable of following size evenly crimped with high pressure tool & connected to switchgear terminals with brass/cadmium plated nut bolts in an approved manner. (A) 1.5/2.5 to 6 Sq.mm |
| 36 | (B) 10 Sq.mm |
| 37 | (C) 16 Sq.mm. |
| 38 | (D) 25 Sq.mm. |
| 39 | Making trench in Hard Murrum / Tar Road of suitable width of 90 cm or requireddepth for laying any size of cable or locating the faultall over the run and back filling the same and making the surface as normal ground. |
| 40 | Covering of cable with second class bricks or cement tileslaid cover the cable crosswise & also on both sides with covering of 7. 5 Cm. layer of sand above & below cable (16 bricks per meter) |
| 41 | Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original. (C) 300 mm dia |
| 42 | Providing & laying approved makeDouble walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connectingaccessories of same material at required depth in existing trenchfor laying ofcable. below ground/ road surface for enclosing cable. (A)50 mm outer dia |
| 43 | (B)63mm outer dia |
| 44 | (D)120 mm outer dia |
| 45 | Supply and installation of Fire stop mortar system equivalent to Hilti CP 636 , with minimum 2 hours fire rating when tested in accordance with UL 1479/ASTM-E 814 standards, for horizontal openings in floors or slabs after passing service lines like cables/cable bundles, cable trays etc. The mortar shall be a light weight cementitious product and shall carry test certificate in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall be age tested as per Dafstb and DIBT standards. The product shall carry test certificate for mold resistance rating of 0 as determined by ASTM G21-96. The product shall be age tested as per Dafstb and DIBT standards.The system shall be UL listed. The gaps around inaccessible or complicated openings shall be sealed with exapnding firestop foam. |
| 46 | 500mm AT WITH BASE 10MM DIA Blunt tip Aluminium Rod |
| 47 | 1000mm AT WITH BASE 10MM DIA Blunt Tip Aluminium rod |
| 48 | Vario connector with SS 304 grade material tested as per IEC 62561-1 from Govt. accredited laboratory |
| 49 | 8 / 10 mm dia universal cross connector SS 304 grade material tested as per IEC 62561-1 from Govt. Accredited laboratory and with CE compliance |
| 50 | 2mtr mast 34mm dia pipe GI with provision of AT base with base plate |
| 51 | 8mm dia Aluminium conductor for installation of roof/terrace complying IEC 62305 |
| 52 | Parapet holding clamp - Polyamide for 8mm dia conductor with UV resistant grade material |
| 53 | Concrete block round type |
| 54 | Expansion piece without connector of Aluminium grade material tested as pr IEC 62561-1 from Govt Accredited Laboratory and with CE compliance |
| 55 | Test Link - Round To flat SS304 tested as per IEC 62561-1 from govt. Accredited Laboratory |
| 56 | Electromechanical counter with IP 65 box |
| 57 | 25x6 GI strip with 86 micron avg Zinc coating |
| 58 | Saddle for Flat strip suitable for 25mm wide strip size |
| 59 | UL Listed Copper Bonded Earthing Rod Dia : 17.2mm, Length : 3000mm Micron : 250, Test Certificate : 25KA rms for 1 Sec. ERDA Teststed. |
| 60 | 17.2mm dia SS double sided clamp |
| 61 | 25kg Carbon+bentonite based backfill compound SRIPCarbon based backfill compound complying IEEE 80, with ROHS compliance from NABL govt. accredited laboratory. |
| 62 | HDPE chamber - High Density poly ethylene chamber for earth inspection |
| 63 | SERVICE CHARGES - Installation with Trained Team & Taking care of all Safety Precautions |
| 64 | Design, Supplying and Erecting Seamless Box Pipeof suitable size for rooftop solar installations with good stability agaist wind, Thickness 2 mm and 80 micron, Hot Dipped Galvanized steel coils. suitable arrangement for base plate for foundation , solar panel mounting, the structure should be suitable for carry the load of solar panel,wiring, sprinkler system etc. with necessary foundation work/wall mount, j bolt, anchor fastner, shop drawing etc. the nut bolt used for installtion of stucture should be (SS 304) quality. box. pipe ref. size (A) 40 x 40 x 2mm, (B) 50 × 50 × 2mm, (C.) 60 x 40 x 2mm,(D) 72 x 72 x2.5mm |
| 65 | Design, Supplying and Erecting \"C\" Channel ofsuitable size for rooftop solar installations with good stability agaist wind, Hot Dipped Galvanized steel coils. It have suitable arrangement for base plate for foundation Screw Arrangement , solar panel mounting, the structure should be suitable for carry the load of solar panel,wiring, sprinkler system, shop drawing etc. with necessary foundation work/wall mount, j bolt, anchor fastner etc. the nut bolt used for installtion of stucture should be (SS 304) quality. |
| 66 | Supplying and Erecting Stainless Steel Nut Bolt (SS 304) for Installation of Solar PV Module, Structures, and other related items with required size as engineer in charge demands for project Size, length upto 10 x 150 mm |
| 67 | Horizontal Directional Drilling (HDD): Supply, Installation, Testing, Commissioning, laying & Fixing of Horizontal Directional Digging/ Drilling (HDD) with Pit work: up 300 mm |
| 68 | Providing and erecting Inverter based approved make split air-conditioning unit consisting of condensing unit with variable speed fan motor, inverter type hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means ofextra supplied proper insulated copper tubing,drain PVC pipes suitable for ( cost includes Eco Friendly green gas charging and 15A plug top & Remote Control & MS Stand) with necessary core cutting. (A) for 0.8 to 1.0ton capacity |
| 69 | (B) for 1.5ton capacity |
| 70 | (C) for 1.7 to 2ton capacity-Premium Cat. |
| 71 | Rate Only Item\"s |
| 72 | Supply, Installation, Testing & Commissioning of following size of Grid Tied Solar Power Plant with Solar Panels (ALMM approved): Frame Material :Anodized Aluminum alloy Frame With Twin Wall Profile, Front Cover : High Transmission Low-Iron Tempered Glass (AR Coated), High efficency and positive power tolerance Pmax: 0/+5, Module Efficiency should be approx.18%-21%,Normal operating temperature 45\"C, Junction Box with Waterproof IP67 & MC4 Compatible and Enclosed with Bypass diodes, 100% Electroluminescence test to ensure error free Modules, Thep. temp. co-efficient of the PV module shall equal or better than -0.45%/degree C. Solar PV modules of minimum fill factor 75% to be used. Unit Production:- 4 to 5 Unit /kw /day (Actual)(1Year Avg) With 10 year Product warranty and 25 year Linear Power Warranty., Solar Inverter: MPPT Range: 80-1000 V, Max efficiency: 97.5% - 98.9%, O/p Frequency: 50/60Hz, Operating Altitude (m) ≤4000, O/p Power Factor: ~1, O/P THDi: <3%, Operating Tempreture Range: -25~60°C, Anti-islanding Protection: Integrated, Input Reverse Polarity Protection Integrated, Insulation Resistor Detection Integrated, Residual Current Monitoring Unit Integrated, Output Over Current Protection Integrated, Output Short Circuit Protection Integrated, Output Over Voltage Protection Integrated, Protection Degree: IP65, User Interface LCD & APP,Datalogger & Communication: GPRS / Wi-Fi, Module Mounting Structure: Seamless Box Pipe / \"C\" Channelof suitable size for rooftop solar installations with good stability agaist wind & weight load., Hot Dipped Galvanized steel coils. suitable arrangement for base plate for foundation , solar panel mounting, the structure should be suitable for carry the load of solar panel,wiring, sprinkler system etc. with necessary foundation work/wall mount, j bolt, anchor fastner etc. the nut bolt used for installtion of stucture should be (SS 304) quality. and Balane of System with necessary Swithgears (Suitabel size and protection of ACDB & DCDB), inter connecting wiring, earthing system, lightining arrester system, all liasoning work with various gov. dipartment like state nodal agency,DISCOM & CEIG is included in agency scope. (Excluding GEDA Application fees, Solar connectivity Charges, Meter connectivity Charges, Meter testing Charges.) . Solar Panel shall be min 595Wp Each or above unit with N-Type Topcon Mono crystalline Silicon Bifacial Module with 30 years Linear Performance Warranty. (A) Grid Tied Solar Power System: 1 - 6 kW (Single phase) |
| 73 | (B) Grid Tied Solar Power System: 7 - 10 kW (3 - phase) |
| 74 | (C ) Grid Tied Solar Power System: 11 - 25 kW (3 - phase) |
| 75 | (G) Grid Tied Solar Power System: 251 - 500 kW (3 - phase) |
| 76 | Providing & erecting Automatic solar panel cleaning system for solar power projects which includes necessary plumbing work (UPVC pipes and accessories) from source of water to project site (upto 30 meters),Suitable size of sub mercible/ open well motor, necessary wiring for motor and sprinkler system with safety, timer circuit for automatically on/off the sprinkler system, necessary size oand number of nozzles/JET (minimum 1 Nozzle/Jet per module). (C ) 11KW-20KW Cleaning System |
| 77 | The all inclusive comprehencive annual maintance contract cost covers yearly maintanance of solar Pv Modules, Inverter, wiring,earthing,switchgears, etc with material and labour cost including preventive maintanance.The cost covers entire installation. AMC also includes monthly site visit and inspection of project with submission of inspection and solar generation report. All parts should be replaced/repaired if found faulty within specified time. Agency has to provide necessory licening work for warranty,power,Bidirectional meter etc. (A) 1KW-10KWSystem |
| 78 | (B) 11KW-20KWSystem |
| 79 | Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand Aluminium conductor for1.1 KV. to be laidon wall with necessary clamps or in existing trench/ pipe of following size of cables. (B) 3 1/2core 35 Sq. mm ( 16 Sq. mm 1/2 core) |
| 80 | (D) 3 1/2 core 70 Sq. mm ( 35 Sq. mm 1/2 core) |
| 81 | (E) 3 1/2 core 95 Sq. mm ( 50 Sq. mm 1/2 core) |
| 82 | (I) 3 1/2 core 240 Sq. mm( 120 Sq. mm1/2core) |
| 83 | (J) 3 1/2core 300 Sq.mm ( 150 Sq. mm1/2core) |
| 84 | Supplying and making end termination with brass compression glandandaluminiumlugsforfollowingsizeofPVCinsulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 35 sq. mm (32mm) |
| 85 | 3½ X 95 sq. mm (45mm) |
| 86 | 3½ X 225 sq. mm (62mm) |
| 87 | 3½ X 240 sq. mm (62mm) |
| 88 | 3½ X 300 sq. mm (70mm) |
| 89 | Providing & laying. R.C.C. Hume pipe for cable to be laid 90 cm. below ground across the road crossing or on floor with necessary material in an approved manner and making the ground as per original. (A) 450 mm dia |
| 90 | (B) 400 mm dia |
| 91 | (D) 250 mm dia |
| 92 | (E)150 mm dia |
| 93 | (F) 100 mm dia. |
| 94 | Providing & laying approved makeDouble walled corrugated pipes (DWC) of polyethylene (conforming to IS 14930 II ) with necessary connectingaccessories of same material at required depth in existing trenchfor laying ofcable. below ground/ road surface for enclosing cable. (C))90 mmouter dia |