| 1 | Maintenance of Distribution Transformer |
| 2 | Half yearly Maintenance on Oil / Dry type Distribution Transformerof capacity 250 KVA -Up to 2.5 MVA(Refer Sec VI (MNC), Clause No.18.2). |
| 3 | Annual Maintenance on Distribution Transformer of capacity3 MVA to 7 MVA(Refer Sec VI (MNC), Clause No.18.1). |
| 4 | Annual Maintenance on Distribution Transformer of capacity Above 7MVA upto 20MVA (Refer Sec VI (MNC), Clause No.18.3). |
| 5 | Carrying out Breakdown Maintenance /Trouble shooting in 11 kV / 415 V panels and transformers at substation. |
| 6 | Operation of filtration plant for Reconditioning of Transformer oil in Transformers/storage Tank/Drums/BOCBs. (Refer Sec VI (MNC), Clause No.20.1). |
| 7 | Collection of Transformer oil samples and Conducting Break Down Voltage test(Refer Sec VI (MNC), Clause No.20.3). |
| 8 | Collection of Transformer Oil into a 20 Ltr container from drum barrel available at Electrical store room, Carrying to various substations and topping up of oil into the Transformers as directed by the Engineer-in-Charge and as per the detailed Specification |
| 9 | Supply and replacing of Silicagel Beadsin Breathers of Transformers/BOCBs/Storage Tanks |
| 10 | Reconditioning of silicagel in Breathers of Transformers/BOCBs/Storage Tanks (Refer Sec VI (MNC), Clause No.20). |
| 11 | Supply and Installation of Flow meter with indicator for 1200 LPH Oil filtration plant as per specifications and as directed by the Engineer-in-charge. |
| 12 | Supply and installation of the 8 SWG size of copper wires in built in trench as per the detailed specification.(Refer Sec VI, Clause No.12.8) |
| 13 | Supply and Installation of 40mm /32mm flange type Gate valves for transformer drain line and oil sample line including flange fixing on both sides of valve, making oil sample pipe arrangement and removal of old valves from transformer bottom. Oil to be removed and refilling to be done for fixing of valves as directed by the Engineer-in-Charge. |
| 14 | Annual Maintenance of 11kV HV bus duct length of 30m to 40m at 5m height at 33kV CSS, including supply of fasteners,cleaning agent such asBaniyan Waste, etc as per detailed Specification (aluminium scafolding tower ladder will be provided by the department) |
| 15 | General maintenance of Transformers |
| 16 | Supply and Installation of Standard Aircell with Flange as per drawing for 20 MVA transformer-3, conservator size 2100 mmlength x 900 mm dia. Excisting aircell size 2150 mmlength x 990 mm dia with loop distance of 1000 mm as directed by the Engineer-in-Charge and as per the detailed Specification |
| 17 | Assisting for Tap changing operations in distribution Transformer including supply of cleaning agent such as Baniyan Waste, etc as per detailed Specification |
| 18 | Assistingfor Arresting of Oil leakage in radiators, valves and other parts of transformer and BOCBs including external cleaning as per the scope of work including supply of cleaning agent such as Baniyan Waste, etc as per detailed Specification |
| 19 | Assistingfor Calibration and testing of OTI and WTI of distribution Transformer including simulation testing between control circuits of panel and transformer as per detailed Specification |
| 20 | Quarterly functional monitoring of Transformers having various capacity as per scope of work (Ref. Sec-VI (MNC) Clause No: 20.14) |
| 21 | Modification ofcontrol wiring in Marshalling Boxes, Transformers and panels |
| 22 | Assisting for carrying out measurement of Insulation Resistance (IR) value on HT equipments/feeders |
| 23 | Temporary connection / disconnection of 415 Volt equipment like Oil Filtration/welding machine etc as per scope of work. |
| 24 | Maintenance / Assisting in Maintenance of outdoor HT equipment or structure |
| 25 | Servicing of 33kV Outdoor P.Ts which includes attending to faults, arresting oil leaks if any, replacement of Gaskets if required, Replacement of Oil etc,andpost service testing as per the specifications and as directed by the Engineer-in-Charge. (Refer Sec VI (MNC), Clause No.13). |
| 26 | Cleaning, painting, wiring tightness check, Post service testing of 33kV Outdoor PTs as per the specifications and as directed by the Engineer-in-Charge.(Three single phase PTs will be measured as one set. |
| 27 | 33kV outdoor VCBs of upto 1250A / BOCBs of upto 2000A |
| 28 | Maintenance of 33kV Outdoor Isolators, Including cleaning, Lubricating, Supporting Insulators healthiness checking and other related works as per the specifications and as directed by the Engineer-in-Charge. |
| 29 | Maintenance of Outdoor 33kV Bus Section including supply of cleaning agent like CRC,baniyan waste etc., |
| 30 | Quarterly maintenance and routine functional test of Mulsifire system in transformer (Ref Sec VI (MNC), Clause No: 20.13). |
| 31 | Painting of EquipmentsSupply and painting One coat on metallic surfaces of electrical equipment and other required surface at all levels with primer & paint (Asian or approved brand, colour and manufacturer) to give an even shade including preparation of the surfaces,providing scaffolding as per the requirements /specifications and as directed by the Engineer-in-Charge. (Refer Sec VI (MNC), Clause No.3). |
| 32 | Synthetic enamel Paint |
| 33 | Aluminium paint |
| 34 | Painting of 33kV Bus bars (R,Y,B) with synthetic enamel paint 60 Sq.m surface area of tubular bus section at an elevation of 5mtr to 7mtr height at 33kV CSS Outdoor switch yard,includes Shifting, assembling and dismantling of aluminium scafolding tower ladder materials and supply of Paints, cleaning agent like CRC,baniyan waste etc.,Scaffolding materials required for the work will be issued free of cost by the departmentas directed by the Engineer-in-Charge.(Refer Sec VI (MNC), Clause No.3). |
| 35 | Painting of 33 kV outdoor circuit breaker with synthetic enamel paint at an elevation of 1 mtr to 6 mtrs inside 33 kV CSS (Refer Sec VI (MNC), Clause No.3). |
| 36 | Painting of Distribution Equipments with ONE Coat of Primer, TWO Coat of Synthetic Enamel Paint including supply of paint & primer and required consumables .(Refer Sec VI (MNC), Clause No.3). |
| 37 | Painting of 11 kV/415 V Bus ducts with synthetic enamel paint (Aircraft grey) at an elevation of 5mtr to 7mtr height at various substations (Refer Sec VI (MNC), Clause No.3). |
| 38 | 400/500 kVA Transformer |
| 39 | Painting of Transformer capacity upto 3 MVA including supply of required paints and other consumables |
| 40 | Shifting of Electrical equipment of various sizes including loading and unloading/Shifting of electrical/telephone items from IGCAR and hand over to service centre (upto Chennai limit) or vice versa.(Refer Sec VI (MNC), Clause No.31). |
| 41 | Shifting of oil filtering machine/transformers of capacity more than Heavy Electrical equipment more than 500 kg distance of more than 500m and upto 5Km. |
| 42 | Items weighing upto 100 kg |
| 43 | Items weighing above500 kg |
| 44 | Equipment weighing upto100 kgs for a distance more than 500 mtrs and upto a distance of 5 kms. |
| 45 | Collecting of scrap items and shifting more than 1 km and up to a distance of 5 kms. Measurement will be done on volume basis (Refer Sec VI (MNC), Clause No.28). |
| 46 | Shifting of Tr. Oil /Diesel with 210 Litres drums(One number :210 Ltrs. Drum) |
| 47 | Shifting of 210 Litres Empty Oil drums. |
| 48 | Assisting for cleaning the spare cub-boards / Tool-racks, shifting of equipments and spares with in the sub-station, re-arranging /positioning the spares and equipments and segregation of materials, cleaning of spares, minor house keeping works as per the detailed specification. |
| 49 | Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/ galvanising as follows including supply of required, fasteners, nuts, washers, etc.(Refer Sec VI, Clause No.11). |
| 50 | MS fabrication 1 coat primer & 2 coats synthetic enamel paint |
| 51 | GI: MS fabrication With hot dipped galvanising. |
| 52 | Clearing light jungle area, bulb weeds, grass including removal all unwanted plants, branches, twigs, wild growth etc.complete, and disposing the same 100 meters away manually or burning them without disturbing other areas etc., complete all as directed by the Engineer-in-Charge. Contractor must inform the Engineer-in-charge and prior permission shall be obtained from him for burning the wild growth.(Refer Sec VI (MNC), Clause No.7.3). |
| 53 | Clearing Heavy jungle area including removal all unwanted plants, branches, twigs, wild growth, trees and saplings of girth upto 30cm, uprooting of rank vegetation etc. complete, and disposing the same 100metres away by manually or burning them without disturbing other areas etc., complete all as directed by the EIC. The useful firewood if any, shall be cut and stacked at a place (with 100metres lead) as directed by the Engineer-in-Charge. Contractor must inform the Engineer-in-charge and prior permission shall be obtained from EIC before burning the wild growth.(Refer Sec VI (MNC), Clause N |
| 54 | Clearing of Vegetation in and around of 33 kV outdoor switch yard of 60m x 50m area including removal all unwanted plants, twigs, wild growth, and, uprooting of rank vegetation etc. complete, and disposing the same 100metres away by manually or burning them without disturbing other areas etc., complete all as directed by the EIC. |
| 55 | Trimming road side tree branches upto 1500mm girth, replanting of fallen trees / branches including collecting and disposing the fallen trees / branches at places shown by department all as per specifications and as directed by the Engineer-in-charge. Note: In IGCAR Plant site fallen trees shall be disposed to the disposal yard through the CTS gate. |
| 56 | Numbering of electrical equipments in following size and shape with synthetic enamel paint of different background colour, letter colour & size of letter as directed by Engineer in Charge (Refer Sec VI (MNC), Clause No.10.3). |
| 57 | within 200mm dia/225 X 100mm area |
| 58 | Painting and letter writing on Transformer bay/Service trenches size of 300x300mm. |
| 59 | Supply and pasting of water proof UV laminated 3M stickers of 300 x 300 mm size consider as 1 No with messages as directed by Engineer in charge |
| 60 | Supply and Installation of Danger Boards for 33kV/11kV system using Powder coated Aluminium base board with printing. Old damaged boards to be removed and installed using S.S fastners in the transformer bay gates, on equipments at various places in IGCAR |
| 61 | Board Size – 450 x 400 mm. 2 mm thick |
| 62 | Board Size – 250 x 200 mm. 1 mm thick |
| 63 | Testing of Transformer oil using NABL accredited Labs (CPRI or ERDA). |
| 64 | Testing of parameters as per IS;1866 as per the scope of work. |
| 65 | Testing ofDGA as per the scope of work. |
| 66 | Furan Analysis as per the detailed scope of work. |
| 67 | Civil workManufacturing, supplying, hoisting and fixing in position at all lifts, precast units of various patterns and sizes for precast plain solid units, slabs, exhaust fan moulds etc., in reinforced cement concrete of 1:1.5:3, using 20mm and below machine crushed graded stone aggregate and crushed stone sand including weigh batching, mechanical mixing, casting, vibrating, finishing of exposed faces, curing, necessary formwork & moulds, transporting and placing at all lifts, preparation of connections, grouting with cement mortar/cement grout wherever needed excluding steel reinforcement complete all as per drawing, specification and as directed by Engineer-in-Charge. |
| 68 | Providing, straightening, decoiling wherever necessary bending, cutting, binding and fixing in position steel reinforcement at all levels TMT bars of Fe500D grade steel conforming to IS:1786 \"SAIL or VIZAG or approved equivalent make\" and tying with approved annealed binding wire of 1.6mm dia in all reinforced cement concrete work at all lifts, including cost of supplying and fixing the spacer/cover blocks in cement mortar 1:2 and binding wire complete all as per specification and as directed by the Engineer-in-charge at all lifts. Note: The rate shall be including the cost of reinforcement steel. |
| 69 | Excavation in hard soil including refilling with excavated earth and disposing surplus earth at places as directed with in a lead of 10 Mtrs. and initial lift upto 1.5 Mtrs. including neat banking as per detailed specification. (Refer Sec VI, Clause No.2) |
| 70 | Supplying of 40mm hard blue granite metal (for repair and maintenance works only) etc. and stacking at place shown for measurement etc. complete all as directed by the Engineer-in-Charge. |
| 71 | Inspection and maintenance of Lightning mast copper conductors and connecting pad on the top of 11 metre RCC pole structure at 33kV out door switch yard. this work includes Shifting, assembling and dismantling of aluminium scafolding tower ladder materials and supply of cleaning agent like CRC,baniyan waste etc.,Scaffolding materials required for the job will be issued free of cost by the departmentas directed by the Engineer-in-Charge. |
| 72 | Shifting, assembling and dismantling of aluminium scafolding tower ladder materialsfor inspection and maintenance work in 33 kV outdoor bus bar at 7 m height (aluminium scafolding tower ladder will be provided by the department) as directed by the Engineer-in-Charge. (Note:1 assembling and 1 dismantling per day per Phase will be taken as 1 No) |
| 73 | AMC Work at DAE Nodal Centre, Pallavaram, Chennai Maintenance/Assisting in Maintenance of IndoorLT/HT equipment |
| 74 | Annual Maintenance on Distribution Transformer of capacity 1.25MVA (Dry Type) (Refer Sec VI (MNC), Clause No.18.1). |
| 75 | Assisting in the mainenance of indoor type VCB/MOCB/Vacuum Contactors of voltages form 3.3kV to 33kV |
| 76 | 6.6/11kV indoor panel Bus-sections containing more than 5 vertical sectionand upto 7 vertical section |
| 77 | PCC consisting up to 10 Nos. ACBs, Cubical Switchboards having number of vertical sections more than 10 and up to 15 |
| 78 | Maintenance of 415V, ACB\"s 630A to 4000A, 3/4 Pole |
| 79 | Testing of Protective Relay VAMP-57 using secondary injection test kitby external agency.Cleaning of relay housing and tightness checking |
| 80 | Maintenance of Transformer LV /HV Bus Ducts length of 7Mtrs at 3 Mtrs height. |
| 81 | AMF panel with 2 Nos. Of ACB or Contactor and Cubical Switchboards having number of vertical sections up to 7 |
| 82 | Annual Maintenance on Battery chargers and batteries |
| 83 | Maintenance of Motor Control centre/Distribution Centre, LT panels/TPN switch Fuse Units (Refer Sec VI (MNC), Clause No.17.2). |
| 84 | Industrial LT panels |
| 85 | External cleaning Cubicle switch boards having number of vertical sections more than 3 ( 415V PCC, 3 Incomer pnl) |
| 86 | External cleaning of 1.1/3.3/6.6/11kV HT/LT Panels of containing 7 to 10 Verical section |
| 87 | Maintenance of Earth Pitsand measurement of Earth Pit Resistance as per the specification.(Refer Sec VI (MNC), Clause No.2). |
| 88 | Cleaning of Indoor Cable trenches (Refer Sec VI (MNC), Clause No.26). |