| 1 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent PVC casing capping of appropriate size as required.>(b) 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm casing ) |
| 2 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately).>(b) In rocky strata |
| 3 | Extra for using salt and charcoal for pipe earth electrode as required( 65 Kgs of Charcoal and 5 Kgs of Salt). |
| 4 | Supplying and laying 6 SWG GI wire at 0.5 m below ground level for conductor earth electrode including soldering etc. as required |
| 5 | Supplying and laying 25 mm x 5 mm GI strip at 0.5 m below ground as strip earth electrode including soldering etc. as required |
| 6 | Supply of 3 1/2 core armoured PVC/XLPE insulated PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.>3 1/2 Core 35 sq.mm |
| 7 | Supply of 4 core armoured PVC/XLPE insulated PVC sheathed aluminium conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.>4 Core 16 sq.mm |
| 8 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Inchargesand cushioning with screened sand bed of 20mm thick protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.>(b) In rocky strata |
| 9 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 120 sq.mm direct in ground including excavation in the form of a trench as per Cable Trench Drawing provided by the Engineer-Inchargesand cushioning with screened sand bed of 20mm thick protective covering with bricks placed breadth-wise on top of cable all over the run( the brick protection shall cover the cable and project atleast 5 cms over the sides of the cable) and backfilling the excavated earth without stones or hard material and making the surface proper with 15 cm crown on the top complete as required.>(b) In rocky strata |
| 10 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 3 1/2 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade complete as required.>(2) 3 1/2 x 35 Sq. mm. |
| 11 | Supplying and making cable end terminations with brass compression gland and aluminium lugs for folowing sizes of 4 Core PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade complete as required.>(5) 4 x 16 Sq. mm. |
| 12 | Supply, installation, testing and commissioning of 90W LED street light fittings with required nut bolts etc. a) Rated Voltage : 230V AC Voltage range : 140V AC to 280V AC Power consumption 90W, White coloured LED b) Power factor : > 0.95 c) Operation Temp : -10 to 55 deg C d) Total Harmonic Distortion(THD) : <=10% e) Ingress protection : IP65 min f) LED Life Span : >50,000 hrs g) Glass type : Toughned glass h) With over voltage, over current & internal surge protection. |
| 13 | Supply and fixing of 0.5mtrs to 1.5mtrs long single arm brackets of HDGI 3.25 mm thick of outer diameter 50 mm for mounting LED street light fixtures, suitable for 6mtr high, galvanized octagonal pole. |
| 14 | Supply and fixing of 0.5mtrs to 1.5mtrs long double arm brackets of HDGI 3.25 mm thick of outer diameter 50 mm for mounting LED street light fixtures, suitable for 6mtr high, galvanized octagonal pole. |
| 15 | Supply and erecting 6 mtrs high, galvanized octagonal pole on RCC foundation with rates inclusive of providing RCC foundation. The details of the of which are provided in the annexure 1 (enclosed). |
| 16 | Fabrication, supply, installation, testing & commissioning of LT street light panel with PCC foundation for street lighting system with required MCCB/MCB, indicating lamp, timer etc complete as required, as directed by the Engineer-in-charge. The details of the panel are provided in the annexure 2 (enclosed). |
| 17 | Providing & fixing G.I. pipes complete with G.I. fittings including trenching & re-filling etc. (external work).>80 mm nominal bore |
| 18 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe etc. complete as required |
| 19 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size exceeding 25 sq.mm but not exceeding 400 sq.mm in the existing RCC/HUME/STONEWARE Metal pipe etc. complete as required Please Enable Macros to View BoQ information |