| 1 | Dismantling of posts or struts of RCC/wood/steel any section incl taking out embedded portion and making good disturbed portion, (posts embedded in concrete or in hard core) complete all as specified and directed |
| 2 | Site clearance, in soft / loose soile including cutting of bushes& small shurbs etc complete all as specified and directed |
| 3 | Excavation in post holes (or similar hole) each in hard and dense soil n.exc 0.50 cu m getting out and removing surplus spoil at a distance not exc 50 metre and making good surfaces complete all as specified and directed. |
| 4 | Plain cement concrete 1:3:6 type C-1 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed. |
| 5 | providing cement concrete type D2, 1:4:8 using 40 mm graded stone aggregate,as in foundations, filling and mass concrete etc., complete all as specified and as directed |
| 6 | 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed. |
| 7 | Mild steel round bars 10mm dia and over, cut to length fixed in chain link fencing complete all as specified. |
| 8 | Mild steel work as in hand rails, half round or other stock section or core for wooden hand-rail straight portion , drilled and countersunk for balusters , nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets including all necessary drilling, bolting or riveting etc and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed. |
| 9 | Mild steel screw bolt (machine made) with hexagonal at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal exc 5cm and n.exc 10cm long, diaMetre of shank 5-10mm , complete all as specified and directed. |
| 10 | Two coats of synthetic enameled paint on steel and iron surfaces over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces complete all as specified & directed. |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 12 | Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0,fixed as in repair all as specified and directed. |
| 13 | Refixing only mild steel frame work as in gates including pintol hinges, stops, hand made sliding bolt etc of ornamental and intricate design after necessay welding complete all as specified and directed. |
| 14 | Dismantling fencing wire mesh any type complete all as specified and directed |
| 15 | Supply only chain link fencing of n.exc 3.00 mm dia galvanized steel wire, size of mesh as approved complete all as specified and directed.Note:-(i) Fixing included under item No 16.(ii) Unit weight (weight per sqm) of chain link fencing shall be derived as per site through a BOO appointed by GE in presence of Contractor\"s authorised rep and shall be kept in record. |
| 16 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed. |
| 17 | Taking down existing plaster of any description on brick wall/ concrete surface including racking out joints, hacking for key, scrubbing down with water etc complete, all as specified and directed. |
| 18 | Rendering 15mm thick on fair faces of brick work or concrete surface in cement mortar 1:4 surface finished even and smooth without using extra cement. |
| 19 | PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in surface channels, benching and drains complete all as specified and directed. |
| 20 | Demolition of brick masonry and built in cement mortar including all quoins arches, pillars completeall as specified & directed |
| 21 | Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar 1:4, complete all as specified and directed. |
| 22 | All as per serial item No 5 herein before but except bricks (using old serviceable bricks) –ditto- |
| 23 | Cement concrete type B-1, 1:2:4 using (20 mm graded crushed stone aggregate) as in copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including the use of forms or moulds with plain faces complete all as specified and directed. |
| 24 | Preparation of new surfacs and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as specified and directed. |
| 25 | Preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat primer , complete all as specified and directed. |
| 26 | Dismantling timber scantling exc 40 Sqcm in section in any position unframed work & removing from site complete all as specified and directed. |
| 27 | Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified & directed by Engineer-in-Charge |
| 28 | Demolition of Textile coverings including frames (if any) and cover fillets (measured flat and not girthed) completed all as specified and directed. |
| 29 | 2mm thick fibre glass reinforced translucent plain coloured sheeting with side lap, fixed with coach screws as in roof, wall etc, complete all as specified and directed. |
| 30 | Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strength 550 Mpa as in roof coverings/cladding to wall, fixed with self tapping screws as specifiedcomplete all as specified & directed |
| 31 | Galvanized, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc. as directed(each line of wire to be measured) fixed as in repair complete all as specified and directed. |
| 32 | Demolition of reinforced concrete such as roofs, flors, beams,staircase, landing, chaffas, facia and similar suspended work (reinforcement cut as required to facilitate demolition) |
| 33 | Providing precast cement concrete louvers and jallies, 40mm thick (measured solid) type B0(12.5mm aggregate) set in cement mortar (1:4), including all mouldings complete all as specified and directed. |
| 34 | Demolition of cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) complete all as specified and directed. |
| 35 | Demolition of stone slabs of any description in floors/ walls laid, bedded and pointed in any mortar complete all as specified and directed |
| 36 | Concrete interlocking pre polished paver block, with grey cement andpigment, design as approved, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Gradelaid over and including 25mm thick sand cushioning, complete all as specified and directed.Notes: The shape/size of paver blocks shall be as approved by the GE. |
| 37 | Factory made rubber moulded machine pressed coloured chequered cement concrete tiles 300mm x 300mm x 22mm thick (with grey cement and pigments), set, jointed and pointed in neat cement slurry with grey cement with pigment to match the colour of tiles, glossy finish, laid over and including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 38 | Coloured non skid porcelain tiles exterior grade 300x300x 8-10mm thick heavy duty (Endura from Johnson or equivalent) as in floor, set and jointed in neat slurry and pointed in coloured cement to match the colour of tiles over and including screed bed or bedding layer of 15mm thick in cement mortar 1:6, complete all as specified and directed |
| 39 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 40 | 16-18mm thick Granite work (of any type table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like, including 15mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite compelte all as specified and directed. |
| 41 | Desilting the drains, removal of mud, removing the grass, vegetation shrubs etc from drain and removing the excavated soil toa distance n.exc 50 metre and depositing where directed at a level n.exc 1.5 metre above the starting point compelte all as specified and directed. |
| 42 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) of 300 /450mm dia set in cement mortar compelte all as specified and directed. |
| 43 | Reinforced concrete pipes, 450 mm boreclass NP2, laid in trench and jointed completewith collars , jointed with cement mortarinculding fitting of same grade complete all as specified and directed. |
| 44 | Plain cement concrete 1:2:4 type B-2using 40mm graded crushed stone aggregate including necessary form work as in path/ flooring, surface finished even & smooth without using extra cementcomplete all as specified & directed. |