}

Tender For Provision Of Storage Sheds And Ancillary Buildings At Munakot Phase Ii, Pithoragarh-Uttarakhand

Tender Notice

52339397
Tender For Provision Of Storage Sheds And Ancillary Buildings At Munakot Phase Ii
Tender
Indian
Uttarakhand
Pithoragarh
18-12-2025

Tender Details

Tender For Provision Of Storage Sheds And Ancillary Buildings At Munakot Phase Ii; 1 SCHEDULE A PART-I(BUILDING WORK) 2 Construction of 4.2 M high URP (RCC Framed Structure)- with blast wall, hard standing and ramp in accordance with STEC pamphlet 3complete all as specified, shown on drawing and directed. 3 Construction of 4.2 M high Ammunition lab (RCC Framed Structure) -in accordance with STEC pamphlet 3 complete all as specified, shown on drawing and directed. 4 Construction of Main fire station building including open repair bay with inspection pit(RCC Framed Structure)complete all as specified, shown on drawing and directed. 5 Construction of Garage for Scooters(RCC Framed Structure)complete all as specified, shown on drawing and directed. 6 Construction of MT Garage for various vehicles(RCC Framed Structure)complete all as specified, shown on drawing and directed. 7 Construction of MT Store for various vehicles(RCC Framed Structure)complete all as specified, shown on drawing and directed. 8 Construction of Petrol Store(RCC Framed Structure)complete all as specified, shown on drawing and directed. 9 Construction of lubrication oil and grease Store(RCC Framed Structure)complete all as specified, shown on drawing and directed. 10 Construction of covered repair bay with inspection pit (RCCStructure)complete all as specified, shown on drawing and directed. 11 Construction of Apron in front of MT area buildings (RCCStructure)complete all as specified, shown on drawing and directed. 12 Construction of MI Room (RCCStructure)complete all as specified, shown on drawing and directed. 13 Construction of Labour amenity Room (RCCStructure)complete all as specified, shown on drawing and directed. 14 Construction of drying and ironing Room (RCCStructure)complete all as specified, shown on drawing and directed. 15 Construction of open garage for Cars complete all as specified, shown on drawing and directed. 16 Construction of MES Maintenance Cell(RCCStructure)complete all as specified, shown on drawing and directed. 17 Provn of RCC dunnage for Igloo/ESH (Size 300mm x 300 mm x 200mm ) 18 Total amount of Sch A Part II A (Internal Water Supply) (For details see Sch A in PDF folder) 19 Total amount of Sch A Part III-A (INTERNAL ELECTRIFICATION) (For details see Sch A in PDF folder) 20 SCHEDULE A PART III-B (INTERNAL ELECTRIFICATION) 21 M & L for Point wiring with PVC insulated PVC unsheathed electric (FRLS) cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (MS boxes for ceiling fans and for light points along with conduit be fixed in ceiling while casting slab for fan point and for light points,in rigid pvc conduit will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including sunk in pressed steel terminal boxes (normal and moduler type) of 1.6 mm thickand including bakelite sheet cover or hylam board of 2.8 mm thick including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screw, washer etc for the following and Make of wire- Grandlay/Havells /polycab, Make of the conduit : Kalinga/AKG/Polycab 22 (a) One lightpoint / fan point / exhaust fan/bell point/ security lightcontrolled by oneone way switch 23 (b) One 3/5 pin socket outlet 5 Amp on the same board with other swithes. 24 (c)One 3/5 pin 5 Amps socket outlet on independant board. 25 (d) One lightpoint / fan point / exhaust fan/bell point/ security lightcontrolled by onetwo way switch 26 Supply and fixingSub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLS) cable of size 4.0 sqmm LT, 1100V grade, down trhough and incl adequate sizes PVC non metallic conduit of 20mm/ approprite dia with accessories and fittings and one run of 4 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm/approprite dia shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe(Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.) Make of Cable- Grandlay/Havells /polycab, Make of PVC conduit - Kalinga/AKG/Polycab 27 Supply and fixing Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLS) cable of size 6.0 sqmm LT, 1100V grade, down trhough and incl adequate sizes in PVC casing and capping approprite size with accessories and fittings and one run of6 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of in PVC casing and capping shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe(Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate.) Make of Cable- Grandlay/Havells /polycab, Make of PVC conduit - Kalinga/AKG/Polycab 28 S&F LED Tubelight fitting20 Watt surface and wall mounted LED batten,in PVC body, polycarbonate diffuser & integrated electronic driver complete with all accessories internally prewired and incl connecting upthree core single wire complete all as spd and directed . Make : HAVELLS : CAT PART No.LHEXAQP7PN1W020, HSN Code 9405, or Crompton : Model - Bright linea,Cat part No. CCS-100-20-65-HL2-DP-NWH, Make : Bajaj, Cat part No. BCLSB 20 2H. 29 S&F Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar ,earth bar,triple pole and neutral 415volts ,flush to wall complete all as specified and directed. .MAKE-LEGRAND / SCHNEIDER /SEIMENS 30 S&F double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 8 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /SEIMENS 31 S&Fdouble door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 amps rated busbar 4 way complete all as specified and directed by Engr-in-charge. MAKE-LEGRAND / SCHNEIDER /SEIMENS 32 M&L for MCB single pole,6 to 40 Amp 240 volt C curve 10 KA, IP 20 transparent lebel holder fully insulated safety shutters suitable for cable up to 35Sqmm cross sectional area completeincluding suitable sizecopper Lugs complete all as specified and directedMAKE-LEGRAND / SCHNEIDER /HAVELLS/HPL 33 S&F Miniature circuit breakers ISI marked 240 Volt, 50 Hz, SPN 40-63 Amps, breaking capacity 10 KA. MAKE-LEGRAND / SCHNEIDER /SEIMENS 34 S&F Miniature circuit breakers ISI marked 415 Volt, 50 Hz, TPN 40-100 Amps, breaking capacity 10 KA , C Curve. MAKE-LEGRAND / SCHNEIDER /SEIMENS 35 Supply and fixing building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic drivertype street light fitting 45Watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete all as specified and directed. Make: Havells, Cat Part No ENDURAPEARLNEOSL45LED757SASYTOPC or Crompton- Model No Raptor Pro-I, Cat part No. CRP-409-45-57-SL-GL-NSG,or Bajaj- Model EDGE NXT LED, Cat part No. ENXT P 45L WW CR PC SD 36 Supply, installation, testing and commissioning of waterheater storage, storage for single phase, 50 Hz AC supply, stainless steel inner assembly, 2 KW heating element, twin thermostat for water temperature and safety thermostat stove enamel outer body including minimum 1 M of three core 2.5 sqmm twisted copper conductorPVC sheathed, three pin plug top, polyethylene pipe connection piece 450mm long of 6kg/sqmm with two sets of chromium plated adopter at each end suitable for 15mm bore GI pipe at cold water inlet and copper tubing connection with chromium plated adopterat ends, at hot water outlet , with safety fusible plug conforming to IS , capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. 37 Total amount of Sch A Part IV (Site Clearance and Earthwork) (For details see Sch A in PDF folder) 38 Total amount of Sch A Part V A (ROAD, PATH & CULVERT) (For details see Sch A in PDF folder) 39 SCHEDULE A PART V-B (ROAD, PATH & CULVERT) 40 M&L for applying theromoplastic reflective paint as in edge line marking 100/125/150 width using hot mark thermoplastic paint ( Hot application) white/golden yellow by ingredient, modern propelled road marking machine as directed including all ingredient such as binder glass beads Titanium dioxide calcium carbonate lintar fillers thermoplastic requirement of glass beads shall be as per the table no. 800-4 specification incl spraying of glass beads instruction complete all as directed. 41 Total amount of Sch A Part VI A (Sewage Disposal) (For details see Sch A in PDF folder) 42 SCHEDULE A PART VI-B (SEWAGE DISPOSAL) 43 M & L for Construction of septic tank 50 users capacity with excavation and earth work in hard / dense soil, PCC 1:2:4 type B2in foundation, 200 mm thiick PCC Solid Block Masonry PCC (1:3:6) in CM (1:6), RCC M-25 using 20 mm graded crushed aggregate as specified,duly reinforced with 8mm TMT bar @ 120mm c/c manhole covers, angle iron frame, vent shaft and sludge chamber etc. complete all as specified, directed and shown on drawing No TD - 217 sheet 1/7 to 7/7. 44 M&L for Construction of LLDPE conventional septic tank for 25 users designed to carry sewage and sullage water, excavationin any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete with effective depth of 1.5m and overall depth of 3m for 10user scred cover with angle iron frame vent shaft an sludge chambers etc complete for 10users complete all as specified and directed. 45 M&L for Construction of LLDPE conventional septic tank for 10 users designed to carry sewage and sullage water, excavationin any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete with effective depth of 1.5m and overall depth of 3m for 10user scred cover with angle iron frame vent shaft an sludge chambers etc complete for 10users complete all as specified and directed. 46 M&L for soakage well with size 1.8 m dia x 3.0 m effective depth including excavation in hard / dense soil, foundation in PCC 1:3:6, walls of honeycombed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of 200 mm thiick PCC Solid Block Masonry PCC (1:3:6) in CM (1:6), RCC cover slab in M-25, interconnecting pipes of RCC complete filled with brick bats complete all as specified and directed.and shown on drawing No TD -309 sheet 1/4 to 4/4. 47 M&L for soakage well with size 2.4 m dia x 4.5 m effective depth including excavation in hard / dense soil, foundation in PCC 1:3:6, walls of honeycombed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of 200 mm thiick PCC Solid Block Masonry PCC (1:3:6) in CM (1:6), RCC cover slab in M-25, interconnecting pipes of RCC complete filled with brick bats complete all as specified and directed.and shown on drawing No TD -309 sheet 1/4 to 4/4. 48 Total amount of Sch A Part VII A (SECURITY WALL) (For details see Sch A in PDF folder) 49 SCHEDULE A PART VII B (SECURITY WALL) 50 S & F of Galvanised steel wire concertina coil of 600 mm dia blade type of 0.60m thick and 65 mm long width 21 mm and 2.5 mm core and blade spacing 100mm fixe in angle iron complete all as specified & directed. 51 M & L for Precast reinforced cement concrete M30 as boundary wall complete all as specified and directed. all as specified and directed 52 Total amount of Sch A Part VIII A (AREA DRAINAGE) (For details see Sch A in PDF folder) 53 SCHEDULE A PART VIII B (AREA DRAINAGE ) 54 M & L for precast cement concrete1:2:4 Type B-1 (20mm graded agg) as in surface channel and drain etc complete and set in CM 1:4 all as specified and directed . 55 Total amount of Sch A Part IX (Lightening Protection) (For details see Sch A in PDF folder) 56 SCHEDULE A PART X (AIR CONDITIONING & REFRIGERATION ) 57 Supply, install testing and commissioning all weather Inverter Split Air Conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated forcooling with intelligent heating, High Ambient Cooling, active Dehumidifier, Anti Microbial Air Filteration, 100% Copper, Instant Cooling, Sleep mode, 4-speed fan function, self Diagnosis complete. 58 Supply, install testing and commissioning Refrigerator, convertible double door with smart inverter compressor, multi air flow, auto smart connect, toughened glass, electric driven (Single Phase), Capacity 240 Litres, BEE 5 Star rated, complete. 59 Supply, install testing and commissioning water cooler electric driver single phase 230V, sinsitu puf insulation, cfc free refrigernt, having energy efficient hermitically sealed reciprocation type compressor, RO & UV purifier, Cooling capacity 40 Ltrs per hour and water storage copacity 80 Liters, all stainless steel body having two taps complete all as specified and as directed. 60 Supply, install testing and commissioning Deep Freezer hard toughened glass top, gross capacity 315/320 liter having double door electric driver single phase 230V, temperture range -24 degree C to +8 degree C, refrigerant R290, inner cabiet made of PP Liner, PUF thickness 60mm complete all as specified and as directed. 61 Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp. 62 Supply, install tensting and commissioing voltage stabilizer for automatic operation, single phase nautrally air cooled indoor type & designed for input variation between 130V to 300V with output stabilized at 230V with accuracy of + 2.5% and of capacity 4 KVA. Make : V Guard, bluestar/Servo 63 Total amount of Sch A Part XI-A (External Water Supply) (For details see Sch A in PDF folder) 64 SCHEDULE A PART XI-B (External Water Supply) 65 Cutting cast iron pipes in position for insertion of new tees, branches, etc.(inclusive of earth work, CI specials, tpt and labour charges etc) complete all as specified and directed at site by Engr-in-Charge 66 Construction of new valve pit brick masonry including dismantling existing unsv valve pit complete with mild steel sheet cover 3 mm thick and angle iron frame of size 40 x 40 x 6 mm duly painted with two coats of synthetic enamel paint over a coat of red oxide primer and including locking arrangement with lock and lifting handle all as specified and shown on drawing brick work of inner surface of pit shall be plasterof cement mortar 1:4 complete all as specified and shown on drawing of size 950 mm x 950 mm x 950 mm (Internal dimension) 67 Total amount of Sch A Part XII-A (External Electric Supply) (For details see Sch A in PDF folder) 68 SCHEDULE A PART XII-B (External Electric Supply) 69 M&L forsand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches complete all as specified & directed. Note- Punned thickness of sand will be measured (18 cm) and paid. 70 Supply , laying,jointing & testing ofXLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 150 Sqmm 3.5 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items. 71 Supply , laying,jointing & testing ofXLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 120 Sqmm 3.5 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items. 72 Supply , laying,jointing & testing ofXLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 50 Sqmm 3.5 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items. 73 Supply , laying,jointing & testing ofXLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 35 Sqmm 3.5 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items. 74 Supply , laying,jointing & testing ofXLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 25 Sqmm 4 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items. 75 Supply , laying,jointing & testing ofXLPE (XLPE cable confirming to IS 7098 Part I) insulated ,armoured heavy duty electric cable with aluminium stranded conductor, 1100 volts grade, cross sectional area 16 Sqmm 4 core complete all as specified and directed.Note: (i) Cable shall be directly procured from the manufacturer(ii) The end termination joint shall be measured and paid separately under respective items.(iii) Excavation, earth work, sand cushioning and cable cover protection will be measured and paid separately under respective items. 76 Supply, installing, erecting, commissioning and testing newfactory made LT panel board, 415 Volts, 3 Phase & 4wire system, cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley protected with bakelite sheet between bus bar & cable alley with front side shutters with locking arrangement, including TPN Aluminium bus bar insulated with colour coaded heat shrinkable sleeve of rating not less then 1.5 times the rated capacity of the incomer MCCB and bus barchamber covered both side using bakelite sheet partition and wire mesh to the back side of cable alley for the protection purpose . All type Test Certificates and Design varification with switch geares (MCCB) as per confirming to IS/ IEC: 61439/2011Part-1 andpart -2 with short circuit test at 65 KA, should be submitted by the contractor before executing the job. The TPN bus bar shall be mounted on F class insulators with intervals not more then 500 mm. 77 All interconnections between the main bus bar as well as incoming/outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less then 1.5 times rated capacity ofindividualoutgoing feeders. All control wiring shall be with FRLS PVC insulated 2.5 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm properly welded with 45 CM long 04 legs of angle iron 50x50x6 mm using 3.15 mm thick CRCA sheet corners to all legs and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of Aluminum lugs and suitable size of chrome plated brass double compression glands provided for incoming and out-going cables comprising the following :- Make of ACB/ MCCB/MCB/Change over switch: L&T/ABB/LEGRAND/SCHNIEDER/SIEMENS 78 INCOMING :- (a) Supply and fix 4 Pole MCCB 200 Amp, 50 Hz, 415 V with rupturing capacity 36 KA with Thermal megnatic relay adjustable type – 01 Nos (Incoming)OUTGOING :- (b) Supply and fix 3 Pole MCCB 32/40 Amp, 50 Hz, 415 V with rupturing capacity 16 KA with Thermal megnatic relay adjustable type – 03 Nos (Main Fire Station, MT area and one for future load)(c)Supply and fix MCB TPN 32/40 Amp, 50 Hz, 415 V– 03 Nos (MI Room, Drying/Ironing room, + 1 for future load)(d)Supply and fix MCB SPN 32/40 Amp, 50 Hz, 230 V– 03 Nos (MT/POL Store, Veh waiting area,+3 for future load)(e)Digital Voltmeter with built in selector switch 0-500Volts -1No(f) Digital Ammeter with built in selector switch 0-200 amps with suitable CTs -1 No(g) LED Indicated Lamp (R,Y,B) one Set-01Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate.(ii) Internal power and control wiring with suitable size PVC insulated multistranded copper wire. 79 Supply, installing, erecting, commissioning and testing newfactory made LT panel board, 415 Volts, 3 Phase & 4wire system, cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley protected with bakelite sheet between bus bar & cable alley with front side shutters with locking arrangement, including TPN Aluminium bus bar insulated with colour coaded heat shrinkable sleeve of rating not less then 1.5 times the rated capacity of the incomer MCCB and bus barchamber covered both side using bakelite sheet partition and wire mesh to the back side of cable alley for the protection purpose . All type Test Certificates and Design varification with switch geares (MCCB) as per confirming to IS/ IEC: 61439/2011Part-1 andpart -2 with short circuit test at 65 KA, should be submitted by the contractor before executing the job. The TPN bus bar shall be mounted on F class insulators with intervals not more then 500 mm. 80 All interconnections between the main bus bar as well as incoming/outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less then 1.5 times rated capacity ofindividualoutgoing feeders. All control wiring shall be with FRLS PVC insulated 2.5 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm properly welded with 45 CM long 04 legs of angle iron 50x50x6 mm using 3.15 mm thick CRCA sheet corners to all legs and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of Aluminum lugs and suitable size of chrome plated brass double compression glands provided for incoming and out-going cables comprising the following :- Make of ACB/ MCCB/MCB/Change over switch: L&T/ABB/LEGRAND/SCHNIEDER/SIEMENS 81 INCOMING :- (a) Supply and fix 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA with Thermal megnatic relay adjustable type – 01 Nos (Incoming)OUTGOING :- (b) Supply and fix 4 Pole MCCB 32/40 Amp, 50 Hz, 415 V with rupturing capacity 25 KA with Thermal megnatic relay adjustable type – 02 Nos (Amn Lab, +1 for future load)(c) Supply and fix MCB SPN 32/40 Amp, 50 Hz, 230 V– 03 Nos (URPs-02, +1 for future load)(d)Digital Voltmeter with built in selector switch 0-500Volts -1No(e) Digital Ammeter with built in selector switch 0-200 amps with suitable CTs -1 No(f) LED Indicated Lamp (R,Y,B) one Set-01Note :- (i) All type of spares such as glands, lugs, nuts, bolts etc, necessary excavation and earthwork, PCC work and making good disturbed surfaces shall deemed to be included in the quoted unit rate.(ii) Internal power and control wiring with suitable size PVC insulated multistranded copper wire. 82 M & L Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 50 x 6 mm, welded/riveted on back side of plate, fixed and grounted in position with PCC type C-1, block of suitable size complete. 83 M & L for installation of Busbar Chamber maSuitable size (CPRI approved) out door type dust proof, vermin proof with IP 56 protection made out of CRCA sheet3.15 mm thick powder coated having provision for frontopening door with hinges including locking arrangements including provision of rubber beading and mild steel cable glands for each cable to make it weather and vermin proof, complete with Copper bus bar capacity 250 Amps 04 Nos . 84 Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection inclusing GI Pipe 40 mm medium grade 0.75 mtr long with mounting bracket 25 x 6 flat ,iron bolt, nut and washers of suitable size complete. 85 Supply and fixing Junction boxwith aluminium bus bar suitable for 3 phase & Neutral , 04 Nos, (RYBN)wire of capacity 100 Ampsand MCB 0.5 to 6 amps SPN complete with fixing clamps etc. . 86 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 3x1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxas directed by Engr- in- Charge. 87 Supply and fixing post top lantern LED type 20 watt 230volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lampcomplete. 88 Supply and fixing post top lantern LED type 20 watt 230volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lampcomplete. 89 EARTHING 90 Earthing complete with copper earth plate electrode60cm×60cm.× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to copper strip 20mmx3mm earth lead stripdia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified. 91 Earthing complete with galvanised steel earth plate electrode60cm×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing testpoint all as specified or indicated including testing on completion complete all as specified. 92 Total amount of Sch A Part XIII (RETAINING WALL AND PROTECTIVE WORK) (For details see Sch A in PDF folder)

Key Value

Document Fees
INR 3000 /-
EMD
INR 1500000.0 /-
Tender Value
INR 90.60 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail