Tender For Provision Of Or Md Accommodation At Clement Town Dehradun.; 2 Construction ofORs Md Accn (G+6 storey),(RCC Framed Structure) ,including RCC over head tank of capacity 25KLoverterrace, with permanent specification all as shown on drawings and as specified. 3 SCHEDULE A PART II-A (Internal Water Supply) for details refer Sch A in pdf folder 4 SCHEDULE A PART II-B (Internal Water Supply) 5 S&F Brass Chromium Plated Wall Mixerfor mixing hot and cold waterwith L bend including shower of size 125 mm and shower arm , screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed. 6 S&F Brass Chromium Plated Central hole wash basin Mixer fancy type with or without lettered Hot or Cold with long screwed shanks and fly nut capstan head screwed for iron pipe suitable for 15 mm bore pipes complete all specified and directed. 7 S&F Brass Chromium Plated Angle Valve, fancy typescrewed for iron pipe suitable for 15 mm bore pipes complete all specified and directed. 8 S&F Health faucet with hose & hook ( complete set) fixed to angle / stop cock 15 mm dia complete all specified and directed. 9 S&F 15 mm bore CP pillar tap fancy type screwed down for iron pipe complete all specified and directed. 10 S&F 15 mm bore brass chromium platedsink mixer fancy type with swinging spout (wall mounted type) for mixing hot and cold water screwed downfor iron pipe complete all as specifed and directed 11 SCHEDULE A PART III-A (Internal Electrification) for details refer Sch A in pdf folder 12 SCHEDULE A PART III-B (Internal Electrification) 13 M & L forpoint wiring using 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade, IS-694 single core multi-stranded (FRLS-H) copper conductor cable in proper colour coding drawn into and including non metallic rigid PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed, sunk cast iron or 1.6 mm thick pressed modular steel terminal box for mounting fittings i.e, modularswitch / socketsincl cover plate with frameincluding one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded FRLS-H copper conductor cable as in earth wire and connecting all metal parts to common earth dolly inclcutting and chases pinning in for concealed conduit wiring and making good of disturbed surface complete all as specified and directed for the following: - 14 Note: (i) Also includes inverter wiringwith one run of inverter wire 1.5 sqmm all alongwith circuit also included. (ii) All items used should be ISI marked. (iii) Cutting chases for concealed type point wiring including making good the same with plaster/putty is deemed to be included in quoted rate by the contractor. (iv) Accessories modular metal boxes, cover plate inner & outer is also deemed to be included in quoted rate. 15 (a) One light point/ bulb/ security light /bell buzzer/ ceiling fan/Exhaust fan point controlled by one-one way switch. 16 (b) One three pin 5 Amp socket on same board with other switches. 17 (c) One three pin 5 Amp socket on independent board 18 (d) All as per item No 5.01 above but for two way wiring 19 (e) All as per item No 5.01 above but point wiring with cable 2.50 Sq mm size, with earth continuity conductor of size 2.50 Sq mm. 20 All as per item No- 5.01 above but point wiring with cable 4.0 Sq mm size, with earth continuity conductor of size 4.0 Sq mm. 21 Supply & fixing decorative wall mounted LED tube light 1 x 20 watt with polycarbonate housing and integrated electronic driver with all acessories and fixing materialcomplete all as specified and directed. 22 Supply & fix decorativeLED tube light 1 x 10 watt wall mounted with extruded polycarbonate, integrated lamp & driver with opel diffuser and decorative end plates complete with all acessories and fixing materialcomplete all as specified and directed. 23 Supply & fix LED lamp 9 watt with suitable for batten / angular holder complete all as specified and directed. 24 Supply and fixing Vertical Loadline sheet metal enclosure double door, Triple pole and neutral (TP&N vertical loadline) AC, 415 volts, 08 way, with 200Amps rated copper bus bar and IP - 54 & IK 09 protection, with the inbuilt provison forfixing of 1 No MCCB 160 Amps Capacity and 24 Nos MCBs inside of DB, with metal door and flush to wall including grouting and cutting in existingwall and making good disturbed surfacewith two coats of white / colour washing / distempering etc to match the existing complete all as specified and directed. Note : MCCB and MCBs shall be provided inside the verticle DBs alongwith suitable size of copper wiring. 25 Supply and fixing BLDC Ceiling fan complete with blades, down rods, electronic fan regulator and accessories 230 Volts, 1200 mm sweep,min air delivery 210 CFMfive star rated with BLDC motor, super energy efficient, including provision of flexible cable 3 core of suitable size from ceiling rose to fancomplete all as specified and directed. 26 Supply and fixinglight duty Exhaust fan 300 mm sweep metal body with sturdy steel bird cage,double ball bearing and heavy duty motor copper winding, metal blades and fixing accessories 230 Volt, 28 Watt and including making hole of suitable size in the wall, plastering the surface making good damaged portion with plaster in CM 1:4 incl recolouring complete all as specified and directed. 27 Supply and fixing light duty Exhaust fan 230 mm sweepmade of sturdy engineering plastic complete with louvers shutter, voltage 230 V, 50 Hz, Rpm 1200, copper windingand fixing accessories 230 Volt and including making hole of suitable size in the wall, plastering the surface making good damaged portion with plaster in CM 1:4 incl recolouring complete all as specified and directed. 28 SCHEDULE A PART IV (Site Clearance and Earthwork) for details refer pdf folder 29 SCHEDULE A PART V (Road, Path and Hardatanding) for details refer pdf folder 30 SCHEDULE A PART VI A (Sewage Disposal) for details refer pdf folder 31 SCHEDULE A PART VI B (Sewage Disposal) 32 M & L for construction of septic tank 100 users withclass B brick masonry wall, PCC in foundation floor, M 30 Design Mix RCC over slab including sludge chamber, CI vent pipe, CI cowl, inlet and out let pipe, RCC baffle wall and all necessary excavation and earth work complete all as specified , shown in TD drawing No 217 sheet No 1/7 to 7/7as directed. 33 M & L for Soakage wells comprising of excavation, in any type of soil, foundation in PCC 1:3:6 type C2 , walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80 M dia X 3.00 M effective depthall as specified and shown in drawing TD-309, sheet No 1/4 to 4/4 34 SCHEDULE A PART VII (Area Drainage) for details refer pdf folder 35 SCHEDULE A PART VIII (Fencing / Gate/ Compound wall) for details refer pdf folder 36 SCHEDULE A PART IX A(Rain Water Harvesting) for details refer pdf folder 37 SCHEDULE A PART IX B (Rain Water Harvesting) 38 Supply andfilling of sand of size 1.50 mm to 2.00 mm in rain water harvesting pit complete all as specified & directed. 39 Supply andfilling of pea gravel of size 5.0 mm to 10.0 mm in rain water harvesting pit complete all as specified & directed. 40 Supply andfilling of stone grit of size 40.0 mm in rain water harvesting pit complete all as specified & directed. 41 Supply andfilling of brick ballast (half burnt ) in rain water harvesting pit complete all as specified & directed. 42 Boring for rain water harvesting 150 mm diameter boring from level to first water tablecomplete all as specified & directed. 43 SCHEDULE A PART X A (External Water Supply) for details refer pdf folder 44 SCHEDULE A PART X B (External Water Supply) 45 M&Lfor Ductile iron pipe, centrifugally cast spun with socket and spigot ends, class K7 suitable for push on joint (rubber gasket D-jointing), 100mm dia, conforming to IS-8329 (2000), in standard length with cement mortar lining inside the pipe without side zinc coating, laid in trenches complete all as specified and as directed. 46 M&L for road cutting 0.75m width and 1.2m depth for laying and dismantling of DI/GI pipes and making good the disturbed surfaces including returning fillingwith and including and PCC (1:3:6) upto depth 20cm from road surface and removing of soil upto 50m complete all as specified and directed . 47 M&L for construction of masonry Pit of size 750 mm x 750 mm x 750 mm for valves and meterscomplete with MS sheetcover and locking arrangement including brick work using sub classB bricks and 15mm thick rendering in cement mortar 1:4 (internal / external) including two coats of white washing to exposed surfaces including2 coats painting to MS sheet cover with synthetic enamelledpaint over a coat of red oxide primer including necessary earthwork in any type of soil and PCC 1:4:8 type D2 as in foundation all as specified and directed. 48 M&L for construction of masonry Pit of size 900 mm x 900 mm x 900 mm for valves and meterscomplete with MS sheetcover and locking arrangement including brick work using sub classB bricks and 15mm thick rendering in cement mortar 1:4 (internal / external) including two coats of white washing to exposed surfaces including2 coats painting to MS sheet cover with synthetic enamelledpaint over a coat of red oxide primer including necessary earthwork in any type of soil and PCC 1:4:8 type D2 as in foundation all as specified and directed. 49 Supply and fixing Air realese valve cast iron,double rubber ball type,body fabricated with cast iron,including high & low pressure cover,cowl as per IS 210 FG 200 conforming to ISI marked, including bolts, nuts, washer and rubber packing all as specified and directed for size 100mm bore of pipe line complete all as specified and directed. 50 SCHEDULE A PART XI A (EXTERNAL ELECTRIC SUPPLY)for details refer pdf folder 51 SCHEDULE A PART XI B (EXTERNAL ELECTRIC SUPPLY) 52 Supplying, installing, commissioning and testing of transformer outdoor type step down 11/0.433 KV (at no load) with HT 3 phase and LT 3 phase 4 wire AC, 50 Hz, 160 KVA, copper wound, Energy Efficiency Level-III type, with offload changing arrangement on HT side for a variation of secondary voltage +/- 7.5% in steps of +/- 2.5 % including suitable cable entry boxes on LT side and HT Bushing on primary side complete in all respects with standard accessories and fitments confirming to IS-1180 (Part-I & II):2014 as specified and as directed including the following- 53 (a) Earthing terminal and rating diagram plate(b) Air release device(c) Oil filling inlet pipe with plug(d) Drain outlet pipe with brass gate valve with dummy plug(e) Conservator with level gauge(f) Silica gel with breather(g) First oil fill up to the recommended level by the manufacturer with new oil confirming to IS 335(h) Type of connection - Delta/Star(j) Type cooling- ONAN(k) Vector group - DYN 11 54 (l) Type of connecting arrangement - ACSR conductor connection on HT Side and cable connection box on LT Side(m) Provision of thermometer with pocket(n)(o) Oil and winding alarm and trip relay including marshal box(p) Platform of Size 3.0x 3.0 x 1.2m height from ground level with stairs including excavation, PCC 1:5:10 type E2 in foundation, brick work in CM 1:6, PCC 1:2:4 type B1 in coping, plastering 10mm thick in CM 1:6 on brick/concrete surface and on top covered with GI chain link fencing 1.20m high gate of mesh size 50 x 50mm and GI wire dia 3.15mm incl suitable size of angle Iron, nuts & Bolts etc. and deemed included unit rate quoted by contractor against this item of transformer. 55 Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-55 (11.00 meters long) with cast iron base frame, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection , including writing of pole Number complete all as specified and directed by the Engr-in-Charge. Note:(1) All excavation & earth work as involved shall be measured & paid seprately.(2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items. 56 Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters long) with cast iron base frame, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection , including writing of pole number complete all as specified and directed by the Engr-in-Charge. Note:(1) All excavation & earth work as involved shall be measured & paid seprately.(2) PCC foundation and Coping as involved shall be measured and paid seprately under respective items. 57 M & L including testing and commissioning of NATURE Switch for outdoor lighting automation using space grade sensors and an advances micro controller suitable for outdoor use having features Automatic Switching ON at Sunset, Automatic Switching OFF at dawn, No clock setting and time settings wide operating voltage range, High voltage trip and auto reset having specification 415 Volts, 50 Hz, 04 Nos incomer MCBs of suitable ratign with auto and manual arrangement including 03 Nos contactor and suitable rating outgoing MCBs single pole type complete with all connected accessories of rating 12 KW 3 phase, current range 40 Amps all as specified. Make- KAKTIYA ENERGY SYSTEM Model No- SWADEEP-02EC12KWP3P or eqvt 58 Material and Labour for Design, supply, Fabrication, Installation, testing and Commissioning factory made, LT panel board, (SIZE NOT LESS THAN-1200X1200X500 MM, LXWXD) Outdoor type, totally enclosed, dust and vermin proof suitably ventilated, floor mounted, 415 volts, 3 phase and neutral, 50 hz, AC supply system, fully compartmentalised, both side openable, made out of 3.00mm thick CRCA sheet steel, protection of enclosure IP-54 as per IS : 2147 of 1962 with pre-treatment and powder coated of approved colour including suitable frame work / support made out of suitable size of angle iron / flat iron, front opening type with provision for cable entry, 59 with proper ferrule and cable glands, internal wiring with PVC insulated multi stranded copper conductor FRLS cable of adequate size (minimum 1.5 sqmm), including required civil works/anchoring bolts for fixing, PCC foundation etc with and including following all as specified and directed : -a)Busbarchamber :Electrically grade copper shrouded bus bar of capacity 400 Amps for each phase and 400 amps for Neutral andcurrent density 0.8/Sqmmincluding interconnection of all switch gears, fixed on DMC insulators and provision of extension. 60 Note- The panel shall be free standing on angle iron having size 65x65x6 mm and height 900mm long with 04 Legs with base support of MS flat of size 100x100x6 mm complete with following scope of work-INCOMER :(i) MCCB 250Amps, 415Volts, 4 pole 50 Hz, 36 KA with adjustable , thermal magnetic release in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed. 01 Nos. (ii) Ammeter 0 to 400 Amps digital type with built in selector switch, CTs of suitable ratio 400/5 amp , 5 VA class 1.0 (set of three) = 01 set. 61 (iii) Voltmeter 0 to 500 volts digital type with built in selector switch = 01 No(iv)AC three phase LT/CToperated multifuctional energy meter of accuracy class-0.5, 3x240 volts 50 Hz, with optical, backlit LCD display, measures and display, trivector energy and load survey, TOD temper detection and lodging power on/off events, instataneous parameter of rating - 5 Amps, with display in absence of power complete - 01 No (v) Phase Indication lamps (RYB), LED type - 01 No (set of three).(vi)MCB SP 6Amps 10 KA,for control protection RYB phase (set of 3)-01 set. 62 Outgoing:Outgoing with one compartment each comparment will consist the following :(i) MCCB 160 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 02 Nos(ii)MCCB 63 amps, 415Volts, 4 pole 50 Hz, 16 KA with adjustable thermal magnetic release, in built instantaneous protection, Ics = 100%Icu(1 sec) complete all as specified and directed- 01 Nos (iii) MCB SP 16 - 20 Amps10 KA- 01 Nos 63 Supply and fixing polycarbonate kiosks box suitable for three phase 415 volts AC supply with 04 Nos Aluminium bus bar rating 63 amps with one NoMCB 16 Amps, SP having size 300X200X150 mm complete including making fixing arrangement on 9 mtr long swaged pole with flat iron clamp including connection from light fitting to junction box with 1.0 sq mm, 3 core wire all as specified and directed by Engr-in-charge. 64 Supply fabricated and fixing street light bracket made out of GI pipe 1.2 mtr long 40/50mm dia medium grade bent to shape including clamps made out of 40 x60 mm flat iron for steel tabular pole, nuts, bolts including painting all as specified 65 Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified. Note :- Punned thickness shall be measured and paid. 66 SCHEDULE A PART XII A (LIFTS)for details refer pdf folder 67 SCHEDULE A PART XII B (LIFTS) 68 Design, supply, install, testing & commissioning of lift carry 8 passengers , cap 554 kgs, speed 1.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+06 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door)including one fireman switch which will be activated in case of fire incident including wiring and talk back facility complete including cable etc all as specified 69 Design, supply, install, testing & commissioning of lift carry 13 passengers , cap 884 kgs, speed 1.5 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+06 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) including one fireman switch which will be activated in case of fire incident including wiring and talk back facility complete including cable etc all as specified 70 Supply & Lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 16 sqmm 4 core. 71 Providing manpower & operation of 4 x pessenger lifts at Clement town military station by providing manpower 01 x Un-skilled lift operator per shift in a day for 8 hrs including Sunday & holiday and carrying out minor regular / periodical repairs and regular servicing for upkeep the passenger lift serviceable in all respect, checking of oil levels, thorough checking of lift, make the machinery /equipment dust free, including thorough cleaning up of battery terminals of ARD unit, greasing/oiling of moving parts, leak testing etc all as specified and directed by the Engineer-in-charge. (Note:- (i)The duration of work will be carried out in three shifts from 0600 hrs to 1400 hrs (First Shift), 1400 hrs to 2200 hrs 72 (Second Shift) and 2200 hrs to 0600 hrs ( Third Shift). (ii)The duration of work will be carried out in three shifts of 08 hrs of each shift by deploying the manpower 02 x Un-skilled lift operator in each shift (Total 06 operators in one day) to operate the 04 Nos automatic lift ( 02 x 08 passengers & 02 x 13 Passenger) in high rise towers of G+6 storey). [24 months for DLP & 36 Months after DLP] 73 Comprehensive maintenance of all mechnical & electrical components & conduct a thorough inspection of the fully automatic 04 x passenger lifts ( 02 x 08 passengers & 02 x 13 Passenger) in two high rise tower of G+6 storey) with mechnical & electrical systems, including motor, cables, brakes, control panels & wiring. Identify any signs of wear, drainage or carring out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair / maintenance of unserviceable parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes, door cards, car door sills, landing door sills, 74 door locks, control cards and its contacts, hall push buttons and its spares, connector / links, welding of crack/broken and MS parts,kanding operating panel of any size & capacity, repair / maint of u/s damaged door safety edge & sensor mechnical safety locks, megnatic lock of contact, car position indicator & all connected accessories, necessary wiring of hall push button assembly, repair/ mantenance of broken COP/LOP buttons & 75 display including cover, fire alarm, firemen button glass, intercom, alarm/hooters, maintenance of damged hand rail shaft, light / switches , complete with illuminated push button & direction indicator with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors & safe operation of lifts, fixing of loose rail brackets if any, cabin mirror light & minor repair of cabin fan, ensure safe & smooth functioning of lift & complete maintenance of car top, binding of loose wire at control panel & rust painting at car top and door, dewatering of lift well in case of any emergency arise all as directed by Engineer-in-charge. [ 36 Months after DLP] 76 SCHEDULE A PART XIII A (DG SETS)for details refer pdf folder 77 SCHEDULE A PART XIII (DG SETS) 78 Supply ,installation ,commission and testing totally enclosed type (silent operation with canopy,CPC B-IV approved ),static type Diesel Engine driven,Generating set of 40 KVAcapacity confirming to BS-5514/IS -13018:1990(Engine) & IS-13364/IS-4722 (Alternator), 4 wire 50 HZ415 Volts supply under NTP conditions when running at 1500 RPM complete including Engine Alternator mounted on common base plate of rigid fabricated mild steel base frame all as recommended by manufacturer and having following provisions all as specified and directed . 79 The silent canopy shall be as per the Central Pollution Control Board norms . The silensor canopy shall be manufacturerd by the manufacturer of the engine itself . The make and model of generator set to be installed with engine details ,alternator specifications and specification of silensor canopy shall be got approved from GE before order is placed by the contractor to the manufacturer. 80 (A) Alternator:- Alternator shall be of capacity of 40 KVA net out put at work site after considering derating factor as per MSL height and NTP conditions as applicable at power factor .85,AC , 3 phase , 4 wire, AVR system, screen protected . Ball / roller bearing with damp proof copper windings on each pole to base as per IS-13364/IS-4722 complete all as specified . 81 ( B ) Diesel Engine :- Diesel shall be of adequate capacity suitable for above alternator after derating factor as per MSL hight and temperature for work siteand as per relevant IS code having provision of coupling shaft to drive the above Alternator independtly after considering power losses in all the accessories forming part of the set i.e. couplings any type FIP , water cooler, direct injector ( if provided ), fan etc. Engine should be multistage, vertical multi cylinder water cooled, 4 stroke, direct injection cold starting , RPM1500, industrrial type standard accessories complete in all respect including all provisions as recommended by manufacture and following provisions complete all as specified and directed. (Note: DG set will be conforming to notification of Min of Environment date 17 may 2002):- 82 (i) Fly wheel with housing .(ii) Air cleaner dry type(iii) Corrosion resisiters.(iv) fuel filter, Oil filter (v) FIP system including pump injectors solenoid controls , nozzles, govenors etc(vi) Radiiator including water pump with fan (vii) Cylinder with buffers, tail pieces duly insulated with asbestos/ lagging and sufficiently extended to carry exhaust outside theDG Set building. 83 (a) Lead acid battery 12 volts , 90/100AH = 01Nos. initially chargedMake :- Exide/Prestolite/ AMCO ( Maintenance free type)(b) Self Starter.(c)Alternator12 volts DC complete with holding clamp. (d) Start / Stop push button ,ignition switch with key system.(e) Battery charging system including regulator and generator / alternator 84 (viii) Engine shallbe with turbo charger.(ix) Engine protection device against low lubicating oil pressure, high water temperature ,and high oil temperature ,over speeding of engine etc.(x) Water temperature gauge, oil temperature gauge, oil puessure gauge ammeter for display charging + Amps etc. 85 (C) ACCOUSTIC ENCLOSURE FOR DG SET :- Supply and fixing accustic enclosures suitable of 40 KVA capacity diesel Generator set duly fabricasted of channel and CRCA sheet 16SWG of required size having doors , insulation sides and top by minralrock wool confirming to IS-8183 of adequate thickness accoustic louvers /outlet. ventilation system etc . complete as per manufacturers instructions with wiring and lighting arrangements duly painted of three coats of dulux gloss synthetic enamalled paint over a primer coat or as directed of suitable size all as required at site and comprising of the following :- 86 (i) Base: MS channel fabricate MS channel made out of 5 mm thick MS sheet of ISMC suitable section .(ii) Structure heavy duty rectangular MS box channel .(iii) Doors fabricated from MS CRCA 2 mm thick air tight with neoprene rubber gasket and gun metal heavy duty spring loaded locks .(iv) Out side cover: Made out of CRCA sheet 2 mm thick.(v)Accustic insulation ( side &Top )sound proofing minerla rock wool slab of density 96Kg/m3confirming to IS 0183 thickness 100mm covered by fire Resistant fiber tissue as per manufacturer recommandation .Test report from original manufacturer to be submittedbefore incorporation in the work for authenticity of material .(vi) Inside cover : CRCA perforated sheet 0.6mm thick powder coated .(vii) Inspection port : Aluminium frame with double wwalled glass fixed type sealed with neoprene rubber gasket for viewing instrument panel . 87 (D)AMF CONTROL PANEL:- As per manufacturers design with the following equipments. (a) 2 Nos. , 3 pole, suitable ratingcontactor -L&T,Crompton, C&S,GE.(b) 02 Nos MCCB of sutable type and rating for DG/Mains incoming-L&T/GE/ C&S(LG ).© Frequency meter -Enercon/Caddle/ AE/ C&S(LG).(d) Ammmeter with suitable CT,s with selector switch-Enercon/Caddle/AE.(e)Voltmeter with suitable switch-Enercon/Caddle/AE.(f) Frequency meter -Enercon/Caddle/AE. 88 AMF logic :The AMF panel shall be provided with micro processer based programmable logical control system of Make -C&S (LG) /UTOPIA /SIEMENS. The control system will have the fillowing option:-(a) Start/ stop settings including delay and timing setting duly programmable.(b) programmable timing for idle running .(c) Auto/ manual option for each contractor .(d) Self starting kiks for three times or as per programme .(e) Alarm for any fault with buzzer and indicating lamp .(f) One main supply voltage monitor .(g) One alternator supply voltage monitor .(h) One set of DC control relays and timers.(j) One set of control relays for the automatic control system . 89 (E) RCC FOUNDATION:- RCC FuoundationM 20(as per manufacturer design) ,450 mm overall height, 300mm above floor level and 150 mm below floor level of required size. (Make of Engine :-Cummins/Kirloskar/ Ashok leyland /Ruston/Greaves.(Make of Alternator:-Kirloskar/Jyoti/Stam Ford,Alston, Electric, Jyoti . 90 (F) Acoustic Louvers / Attenuators at Air inlet/outlet :-The acoustic louvers provides excellent sound attenuation and good weather protection. Single blade and chevron blade louvers are manufacturefrom 16 SWG CRCA sheet top section with an acoustic in fill of resin bonded mineral rock wool has a density of 96 Kg/m3 .The under section is formed from 18 SWG CRCA performed sheet after covering with resistance tissues to prevent fire migration or by means of acoustic lined ducts. 91 (G) FUEL TANK :- One No of sheet metal steel tank of suitable capacity of hold diesel sufficient for 12 hours running at full load, mounted on angle iron frame including the following:-(i) Level indicator to indicate level of diesel in tank. (ii) Drain plug with 2.0 mtrs pipe for draain oil.(iii) fuel strainer.(iv) Pipe for fuel.(v) Air vent.(vi) Mannually operated one no. fuel pump. 92 (H) INSPECTION PORT :-Aluminium box frame with double welded glass fix type sealed with neoprene rubber gasket, for viewing instrument panel.(J) VENTILATION :- Forced with suitable fan. 93 (K) WIRING AND LIGHTING :-PVC copper wire concealed in flexible conduit provided with florescent tube light and MCB.(a) Earthing panel (Neutral body).(b) Control Panel .© Cable leads for batteries.(d) Power cable to euipment.(e) Self StarterNOTE :- (a) Generating set will be placed on suitable foundation as recommended by manufacturer .and cost thereof shall be included on the prices quoted .(b)Tools shall be supplied as per manufacturer,s instructions and cost thereof shall be included in the price quoted . 94 SCHEDULE A PART XIV A (Fire Alarm & Fire Fighting) 95 SCHEDULE A PART XIV B (Fire Alarm & Fire Fighting) 96 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,2 core, 1100 Volts grade 97 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,4 core, 1100 Volts grade 98 Supplying installation testing and commissioning of addressable electronic Hooter with audioable range of 25 to 30 mtr with suitable output wattage.These Hooter should be such that they are capable of public announcement as well as used for fault as requried. 99 S & F active repeater ,silence ,mute, reset,accept,evacute and test controls, DX control panels require a 24 V dc supply and an RS485 card required when used with ZX control panel. 100 Fire pump electric driven engine horizontal end suction cetrifugal type as per relevant IS with CI casing bronze impeller and stainless steel shaftmounted on heavy duty bearings suitable continuous operation 0-150% of rated capacity for 415 Volt 3 Phase 50m Hz AC supply for discharge head 900 LPM at 36 m Head complete with automatic start system in case electric supply failure and mannual Start off having battery of appropriate rating, self starter,foundationcomplete all as directed by Engineer-in-Charge. makes: shakti pumps india ltd/Kirloskar/CG 101 Supply, installation, testing and commissioning out door type cubical panel board outer shell made out of3.15 mm thick CRCA sheet and inner shell made out of 3.15 mm thick CRCA sheet and MS angle of suitable size on PCC 1:2:4 type B-1 platform frame factory fabricated with front and back open able double door systemlouvers and air vent gasket for natural flow of air “U” type gasket shall be used to make the outer shell completely vermin proof .suitable for 3 phase 4 wire 415 Volt, 50 Hz, factory fabricated (Factory approved from CPRI)having modern fabrication and followed by powder coat painting comprising of the following:- (Main Elect Panel ) 102 (a) MCCB 415 volts .4P ,200 Amps 16 KA(incoming)-01 No(b) MCCB 415 volts .4P,63Amps 16 KA(O/G)-03 Nos (for Fire pump & lift)(c) MCCB 415 volts .4P,63 Amps 16 KA(O/G)-01 Nos (for Fire alarm Panel)(d) MCCB 415 volts .4P,100Amps 25 KA(O/G)-01 Nos (for bldg)(e) Space for starter - 01 No(f) Bus bar chamber with and including Aluminium strips (set 4 nos) suitable for 300 ampsduly mounted on porcelain insulators-01 Set(g) DigitalAmp meter 3 phprogrammebale type with suitable CTs -01 Set(h) Digitalvolt meter 3 phprogrammebale type suitable for 500 Volt -01 Set (j)LED Phase indicator R, Y & B-01 Set 103 S&F water type extinguisher(IS: 15683) 9kg capacity 104 S& F light weight squeenze grip type CO2 Extinguisher(IS: 15683) 4.5 kg capacity 105 S&F Dry power (ABC) extinguisher(IS: 15683) 9 kg capacity 106 S&F Dry Mechanical foam extinguisher (IS: 15683) 9 ltr capacity 107 S&F Fire buckets(Dry sand) (IS:2546) 108 S&FFire bucket stand post 109 SCHEDULE A PART XV (Heating Appliances) 110 SCHEDULE A PART XVI (Lightening Conductor) 111 SCHEDULE A PART XVII (Dismantling / Demolition)