| 1 | Demolition of brick tiles or terracing tiles, single layer on roofs all as specified and directed by Engineer - in - Charge. |
| 2 | Demolition of mud in roof, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) all as specified and directed by Engineer - in - Charge. |
| 3 | M & L cement concrete (1:2:4)type B-1 using 20mm graded stone aggregate as in kerbs or mud stops, rounded or chamfered on edges and similar work etc. including cleaning/ removing all dust from existing roof surface all as specified and directed by Engineer - in - Charge . |
| 4 | M&L rendering 10 mm thick on concrete surfaces of slab in CM 1:4 with admixture ofliquid water proofing compound @ 250 ml per bag of cement on green concrete surfaces complete all specified and directed.Note: Water proofing shall be measured & paid separately. |
| 5 | M & L applying one coat of cold bituminious primer @ 0.4 litre per Sqm on plaster surface including cleaning of surfaces all as specified and directed by Engineer – in – Charge |
| 6 | M&L for APP based polymeric membrane minimum weight 3kg per sqm and minimum 3mm thick reinforced with polyster non woven fabric (weight not less than 150 gm per Sqm) laid over primed surface by force application and APP membrane shall be covered with bituminious based aluminium paint @ 0.2 Kg per Sqm in two coats complete all as specified and directed. |
| 7 | Cleaning existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc complete andapplying two coats of alkaline rust converting primer with a coverage of 350gm per sqm on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluable and adhesive protective layer, including cleaning the reinforcement, wire brushing to remove the rust spalls, with time interval of 1 hour between the coats.Product: Sika Rustoff-100 or equivalent makes M/s Fosroc or M/s Pidlite.Note: Measurement per sqm surface area of concrete shall be considered for payment. |
| 8 | Providing and application of zinc rich epoxy anti-corrosive protective coating for existing rebar corrosion protection system in 2 coats of 0.4 kg per sqm. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/mm2 according to ASTM C 882-78.Product: SikaTop Armatec-108 Plus or equivalent makes M/s Fosroc or M/s Pidlite.Note: Measurement will be surface area of concrete shall be considered for payment. |
| 9 | M&L providing and applying 15-20 mm thick layer of single component, fibre reinforced, sulphate resistant, low shrinkage, high performance cementious structural repair mortar conforming to EN 1504-3 Class R4 on exposed concrete surface as per technical specification. Material should have Compressive strength ≥ 55 MPa as per EN:12190, Chloride ion content ≤ 0.05% as per EN:1015-17, Adhesive bond ≥ 2.0 MPa as per EN:1542, Carbonation resistance dk ≤ control concrete [MC(0,45)] as per EN:13295 & Elastic modulus ≥ 20.0 GPa as per EN:13412. (Complete finished item with all leads and lifts) Product: Sika MonoTop-122F or equivalent makes M/s Fosroc or M/s Pidlite.Note: Measurement will be surface area of concrete shall be considered for payment. |
| 10 | Demolition brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removing of debris from the site complete all as specified. |
| 11 | M&L Brick work with sub class \"B\" old size burnt bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge . |
| 12 | Taking down cement plaster/ terrazo finish on brick wall including racking out joints, hacking for keys scrubbing down with water all as specified and directed by Engineer - in - Charge. |
| 13 | M & L rendering 10mm thick on fair facesof brick work or concrete surfacesin CM 1:6 finished even & fair without using extra cement all as specified and directed by Engineer - in - Charge . |
| 14 | M & L two coats of distemper oil emulsion over chalk whiting,preparatory to distempering, on newlyplastered surfaces of walls including preparation of surfaces all as specified and directed by Engineer - in - Charge. |
| 15 | M & L 15mm thick rendering in Cement Mortar 1:4 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge. Note:- The rates do not include for the supply of integral water proofing compound, which shall be paid for in addition at “supplied only rates separately, as applicable. |
| 16 | M & L two coats of cement paint on plastered wall surfaces including preparation of surface after complete removal of existing treatment complete all as specified and directed by Engineer - in - Charge . |
| 17 | M & L applying two coat of cement base paint on new plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer - in – Charge |
| 18 | Supply only liquid waterproofing compound all as specified and directed by Engineer - in - Charge. |
| 19 | M & L two coat of white wash on old decorated plastered or unplastered surfaces of ceiling including preparation of surfaces complete all as specified and directed by Engineer - in - Charge . |
| 20 | M & L two coats of distemper oil emulsion over a coat of wall putty (Asian / JK / Birla), preparatory to distempering on old surfaces after complete removal of existing treatment all as specified and directed by Engineer - in - Charge. |
| 21 | M & L for preparation of old painted wooden surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint all as specified and directed by Engineer - in - Charge . |
| 22 | M & L for preparation of old painted steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint all as specified and directed by Engineer - in - Charge . |
| 23 | Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer - in - Charge . |
| 24 | M & L for 75mm thick cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in sub floors, sub bases etc all as specified and directed by Engineer - in - Charge. |
| 25 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.all as specified and directed by Engineer - in - Charge. |
| 26 | M & L for 75mm thick cement concrete type C-2 (1:3:6) using 40mm graded stone aggregate as in plinth protection etc with joints filled wih sand mix or bituminous at every interval of 3 metre all as specified and directed by Engineer - in - Charge. |
| 27 | Dismantling floor or wall tiles including cement mortar bedding, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer - in – Charge. |
| 28 | M & L for glazed ceramic coloured tiles 7mm thick 450 x 350mm size in vertical surface set and jointed in neat cement slurry and pointed in white cement paste pigmented to the shade over and including 10mm thick cement sand plaster (1:4) complete all as specified and directed by Engineer - in - Charge. |
| 29 | M & L machine cut Kota stone slab flooring 20 – 25mm thick over and including cement screed base 20mm thick in cement mortar 1:3, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed by Engineer - in – Charge. |
| 30 | M & L for non skid ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white cement paste pigmented to tile shade over and including 15mm thick cement and sand screed (1:4)complete all as specified and directed by Engineer - in - Charge. |
| 31 | Taking down chowkhats or frames with shutters without taking off shutters from the frame exceeding 1.5 Sqm but not exceeding 4 Sqm each andall as specified and directed by Engineer - in - Charge. |
| 32 | Taking down chowkhats or frames with shutters without taking off shutters from the frame not exceeding 1.5 Sqm each andall as specified and directed by Engineer - in - Charge. |
| 33 | S & F pressed steel door frames with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, size of frame 105X60mm , complete all as specified and directed by Engineer - in – Charge . |
| 34 | S & F plain framed paneled shutters, any No. of panels with panels of plywood 9mm thick for two or more panel construction and 12mm for single panel construction, BWR conforming to IS fixed to timber frame of 2nd class hard wood, 30mm thick all style & rail are as per SSR Part – Iall as specified and directed by Engineer – in – Charge . |
| 35 | S & F Solid PVC door frame factory made of size 50mmx 47mm made out of 5mm plain colour PVC sheet reinforced with MS Square tubejointed , supplying and fixing in opening complete all as specified and as directed by Engineer-in-Charge |
| 36 | S&F Factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded coloured PVC ’C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed into the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying andfixing in the frame at site as per specification complete all as specified and as directed by Engineer-in-Charge. |
| 37 | Cutting hole in brick wall built in cement mortar not exceeding half brick for fixing holdfasts in jambs and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4, type B – 1 all as specified and directed by Engineer - in - Charge. |
| 38 | S & F aluminium handle cast type anodised, 150mm long all as specified and directed by Engineer - in - Charge. |
| 39 | S&F100 mm size butt hinges, medium weight cold rolled mild steel complete all as specified and as directed by Engineer-in-Charge. |
| 40 | S&F75 mm size butt hinges, medium weight cold rolled mild steel complete all as specified and as directed by Engineer-in-Charge. |
| 41 | S & F aluminium alloy anodized sliding door bolt with hasp and staple (bolt type) and fixing clips of sheets cast or extruded section and fixing bolts of extruded section or cast aluminium alloy 300mm size all as specified and directed by Engineer - in – Charge . |
| 42 | S & F Aluminium anodised barrel tower bolt of extruded section 150mm long all as specified and directed by Engineer - in - Charge |
| 43 | S & F floor door stopper 140mm of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor all as specified and directed by Engineer - in - Charge. |
| 44 | S & F Aluminium anodised barrel tower bolt of extruded section 100mm long all as specified and directed by Engineer - in - Charge |
| 45 | S & F aluminium handle cast type anodised, 100mm long all as specified and directed by Engineer - in - Charge. |
| 46 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified and directed by Engineer - in - Charge . |
| 47 | S & F 4mm thick sheet glass ordinary quality and glazing with aluminium snap beading on aluminium frame for door, windows and ventilators in square not exceeding 0.50 sqm in each pane all as specified and directed by Engineer - in - Charge . |
| 48 | M & L providing two coats of synthetic enamel paint over a coat ofpink primer on new wooden surfaces including preparation of surface of any description over 10 cm width or girth all as specified and directed by Engineer - in - Charge . |
| 49 | Demolition of Reinforced cement concrete (reinforcement cut as required to facilitate demolition) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise specifically provided for all as specified and directed by Engineer - in - Charge . |
| 50 | Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directed by Engineer - in - Charge. |
| 51 | S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engineer - in - Charge. |
| 52 | Dismantling wrought iron or mild steel work of any description all as specified and directed by Engineer - in - Charge . |
| 53 | S & F Rolled sections conforming to Fe-410-W (Gde E-250 Quality), as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates complete all as specified and as directed by Engineer-in-Charge. |
| 54 | S & F framed work such as grills, grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work for water tanks and similar work conforming to Fe-290 Gde E-165 all as specified and directed by Engineer - in - Charge. |
| 55 | Dismantling of fencing wire mesh, any type all as specified and directed by Engineer - in - Charge. |
| 56 | Dismantling posts or struts embedded in concrete / hard core including taking out embedded portion and making good disturbed ground all as specified and directed by Engineer - in - Charge. |
| 57 | M&L Cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate for foundations, fillings and mass concrete all as specified and directed by Engineer – in - Charge. |
| 58 | S & F mild steel work as in posts, struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc, and necessary provision ofnotch including welding and cutting at bottom etc; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 all as specified and directed by Engineer - in - Charge. |
| 59 | Supply only chain link MS galvanised fencing any size or type all as specified and directed by Engineer - in - Charge. |
| 60 | Fixing only of chain link fencing including line wire, any mesh size and type to any type of standard rails straining bolts etc including provision of binding wire all as specified and directed by Engineer - in - Charge. |
| 61 | S & F galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at cross with and provision of galvanised mild steel wire, staples or steel pins etc all as specified and directed by Engineer - in - Charge. (Each line to be measured separately) |
| 62 | M & L 10 mm mild steel round bars Fe-410-W(Gde. E-250) quality-A or Fe 290(Gde-E-165) for securing chain link fencing including forming necessary hook/ bend for tightening with fencing post and the like complete all as specified and shown on drg. |
| 63 | M & L providing two coats of synthetic enamel paintand a coat of red oxide primer onnewsteel surfaces including preparation of surface of any description over 10 cm width or girth all as specified and directed by Engineer - in - Charge . |
| 64 | M & L providing two coats of synthetic enamel paint over new surface and a coat of red oxide primer on steel surfaces including preparation of surface of any description not exceeding 10 cm width or girth all as specified and directed by Engineer - in - Charge . |
| 65 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness, including cover fillets all as specified and directed by Engineer - in - Charge. |
| 66 | Dismantling timber in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section , in any position all as specified and directed by Engineer - in - Charge. |
| 67 | S&F anodized aluminium frame with Powder Coating (minimum thickness of powder coating 50 micron) for doors, windows, ventilators, partitions etc., with one or more rebates including joining cleat for fixing etc complete all as specified and as directed by Engineer-in-Charge. |
| 68 | S & F5.5mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane all as specified and directed by Engineer - in - Charge . |
| 69 | M & L pre-laminated particle board, 12mm thick interior grade, pre-laminated both sides with decorative choice laminations, fixed with screws to timber frame work complete all as specified and directed by Engineer - in - Charge. |
| 70 | S & F as in repairs Steel rolling shutters, having thickness of laths 1.25mm, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated gear operated type with bevel gear box and crank handle complete all as specified and directed by Engineer-in-Charge. |
| 71 | Taking down carefully old and unserviceablealuminium point wiring for light/fan/socket or power point complete including fittings such as switches, ceiling rose, pendents,regulators, sockets, bell, distribution boards andMCB\"s etc and making good disturbed surface of walls, floors etc to match with the existing surface complete all as specified and directed. |
| 72 | M & L point wiring complete with 1.5 Sqmm (nominal area) PVC FRLSinsulated unsheathed copper stranded conductor cable with colour code in and including medium grade rigid PVC conduit with tees, bends, elbows, couplers, MS junction boxes concealed after cutting chases in wall, floor etc and making good to match with existing surface including sunken iron terminal box, 3mm thick bakelite sheet cover, clips, pipe hooks, brass screws, washers and 1.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth and connecting to earth dolly for One light /bell point/ fan point controlled by one, one way switch all as specified and directed at site by Engineer – in – Charge. |
| 73 | All as per Srl item No. 72 here-in-before but one 06 Amp socket outlet point on independent board controlled by one, single pole, one way switch, complete all as specified and directed. |
| 74 | All as per Srl item No. 72 here-in-before but one 06 Amp socket outlet point on same board controlled by one, single pole, one way switch, complete all as specified and directed. |
| 75 | All as per Srl item No. 72 here-in-before but one 16 Amp socket outlet point on independent board controlled by one 16 Amp switch with 2.5 Sqmm wires, complete all as specified and directed. |
| 76 | S&F submain wiring as in repairs with 2 runs of single core 6 sqmm PVC insulated unsheated multistranded 1100 volts grade FRLS copper conductor drawn through and including ISI markes PVC conduit and conduit accessories of medium grade not less than 20mm dia in concealed system including one run of single core 6 sqmm dia FRLS PVC insulated unsheated multistaranded 1100 volts grade copper conductor cable as earth continuty conductor along with the wiring and connected from Submain DB/main board to Metal clad socket complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one runs of 6 sq.mm copper earth continuity conductor shall be measured as one unit length.(ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.(iii) The quoted rate shall deemed to include the cutting chases and making good to match with the existing surfaces. |
| 77 | S&F switch piano flush button single pole one way 6 Amp all as specified and directed by Engineer - in – Charge. |
| 78 | S&F regulator electronic stepped heavy duty flush type 230 volt AC, white colour fixed in switch board after cutting necessary chases to required size complete connections all as specified and directed by Engineer-in-Charge. |
| 79 | S & F socket outlet 2 in 1, 3 pin, 6 Amps, flush type all as specified and directed by Engineer-in –Charge. |
| 80 | M&L ceiling rose 6A, 240V, 50Hz three terminals PVC/ polycorbonate, isolated body all as specified and directed by Engineer - in - Charge . |
| 81 | M&L Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings all as specified and directed by Engineer - in - Charge . |
| 82 | S&F switch piano flush button single pole one way 16 Amp all as specified and directed by Engineer - in – Charge. |
| 83 | S&F socket outlet 2 in 1, 3 pin, 6 and 16 Amps, flush type complete all as specified and as directed by Engineer-in-Charge. |
| 84 | S & F as in repairs MCB distribution board of sheet metal triple pole and neutral 4 way, double door, with 200 Amp rated bus bar 240 volt, neutral link and earth link complete including cutting to wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with existing surface all as specified and directed by Engineer-in- Charge. |
| 85 | S & F as in repairs MCB distribution board of sheet metal single pole and neutral 8 way, double door, with 200 Amp rated bus bar 240 volt, neutral link and earth link complete including cutting to wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with existing surface all as specified and directed by Engineer-in- Charge. |
| 86 | S&F as in repairs MCB Three Pole and Neutral (TPN) 63 Amps, 415 Volt, \"C\" Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge. |
| 87 | S&F as in repairs MCB Single Pole and Neutral (SPN) 40 Amps, 415 Volt, \"C\" Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge. |
| 88 | S&F as in repairs MCB Single Pole and Neutral (SPN) 6-32 Amps, 415 Volt, \"C\" Curve with rupturing capacity not less than 10 KA all as specified and directed by Engineer– in– Charge. |
| 89 | Supply and fix as in replacement LED batten with CRCA sheet steel box type body pre-wired suitable for and including provision of 1x20 Watt (4 feet) retrofit LED tube with PC body, full white and connecting up with twisted three core flexible copper wire of 0.5 Sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge. |
| 90 | Supply and fix as in replacement integrated LED batten 9/10 watt, 2 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed by Engineer-in-Charge. |
| 91 | Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick, burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to and including galvanized earth lead wire 4mm dia by means of GI bolts, nuts, check nuts and washers and connected other end to main board duly protected by GI pipe 15mm bore, medium grade, earth plate surrounded by packed layer of coal dust and common salt 15cm thick all around bottom and top watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate No. 3 of SSR Part – I and connecting to earthing test point, main switch board and testing on completion including CI cover, frame and PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in earthing pit with CI cover and frame including necessary earth works etc, all as specified and directed by Engineer - in – Charge.Note:-1. PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner. |
| 92 | Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades and re-fixing back the same duly cleaned, servicing & oiling and connecting up including provision of three core, flexible cable of size 0.75 sqmm from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-Charge. |
| 93 | Taking down exhaust fan, sealing cable end, dismantling blades and removing fan and blades and re-fixing back the same duly cleaned, servicing & oiling and connecting up including provision of three core, flexible cable of size 0.75 sqmm from ceiling rose or connector to fan complete all as specified and directed by Engineer-in-Charge. |
| 94 | Supply and fix as in replacement of LED street/security light fitting 35 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 50mm bore medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washersand provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting including taking down existing unserviceable light fitting of any description complete all as specified and as directed by Engineer-in-Charge. |