| 1 | Excavation in trenches not exc. 1.5 mtr wide and not exc. 1.5mtr in depth for foundation of pole and laying of CI/ GI/ DI/ PPR pipe and getting out in Hard/ dense of soil, complete all as specified and directed by Engr-in-charge. |
| 2 | Removing surplus soil to a distance not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point, complete all as specified and directed by Engr-in-charge. |
| 3 | Returning filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed by Engr-in-charge. |
| 4 | Supply and fix of 3-layer PP-R Polyproplene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to walls, ceilings with proper clamping system or laid in trenches etc.outer diameter ofpipe 20mm, complete all as specified and directed by Engr-in-charge. |
| 5 | Supply and fix of 3-layer PP-R Polyproplene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polyproplene random fittings fixed complete to walls, ceilings with proper clamping system or laid in trenches etc. outer diameter of pipe 25mm, complete all as specified and directed by Engr-in-charge. |
| 6 | Supply and fix of 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings with proper clamping system outer diameter of pipe 40mm, complete all as specified and directed by Engr-in-charge. |
| 7 | Supply and fix of 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches. outer diameter ofpipe 50mm, complete all as specified and directed by Engr-in-charge. |
| 8 | Supply and fix of 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches. outer diameter of pipe 63mm, complete all as specified and directed by Engr-in-charge. |
| 9 | Supply and fix in replacement of of PP-R Gate valves (brass insert) as per requirement of the site of size 63 mm bore, complete all as specified and directed by Engr-in-charge. |
| 10 | Supply and fix in replacement of PP-R Gate valves (brass insert) as per requirement of the site of size 50 mm bore, complete all as specified and directed by Engr-in-charge. |
| 11 | Supply and fix in replacement of PP-R Gate valves (brass insert) as per requirement of the site of size 40 mm bore, complete all as specified and directed by Engr-in-charge. |
| 12 | Supply and fix in replacement of PP-R Gate valves (brass insert) as per requirement of the site of size 25 mm bore, complete all as specified and directed by Engr-in-charge. |
| 13 | Supply and fix in replacement of PP-R Gate valves (brass insert) as per requirement of the site of size 20 mm bore, complete all as specified and directed by Engr-in-charge. |
| 14 | Material and labour for Drilling and tapping DI/ cast iron water mains (in position) for branch connections of the internal dia 20mm bore complete all as directed. |
| 15 | Taking up old U/S GI/PPR pipe and connections ofsizes 63mm bore . |
| 16 | Taking up old U/S GI/PPR pipe and connections ofsizes 20mm bore . |
| 17 | Taking up old U/S GI/PPR pipe and connections ofsizes 25mm bore . |
| 18 | Taking up old U/S GI/PPR pipe and connections ofsizes 40/50 mm bore .Note: Excavation for takingout and laying out for new pipe is same. |
| 19 | Material and labour for fixing Water proof insulation tape of length 3 Mtr, Width 20 mm for jointing the submersible cables. |
| 20 | Dismantling Altoc dosing motor 0.5 HP and taking Out complete burnt out Winding from the Slots, Cleaning the Slots and Re-winding Electric Motor with PVC Insulated Super Enamel Copper Wire of suitable guage / size and quantity including applying insulating varnish, Drying,two coat painting etc including replacement of unserviceable spares like bearing etc and testing insulating strength all as per dirtected by Engr-in-Charge.Note : Contractor will redo the job for free of cost if winding burnt out within 06 months period. |
| 21 | Supply only MPR300 Motor protection with inbuilt earth fault protection, Relay O/L range 8-22 including Birelay with Single Phase Preventor all as directed |
| 22 | Supply only MPR300 Motor protection with inbuilt earth fault protection, Relay O/L range 16-44 including Birelay with Single Phase Preventor all as directed |
| 23 | S & F single phase preventor with accessories suitable for electric motor 12.5- 20 HP capacity with necessary electrical connection by using proper size of single core copper wire complete incld taking down/ removing old U/S ones with necessary electrical connection complete as directed.by Engr-in-Charge Make : L &T/Siemens or equivallent. |
| 24 | De-coupling removing air compressor 2-3 CFM capacity upto 2.0 HP, 3 phase/single motor, transporting to workshop, dismantling complete, overhauling, replacing of unserviceable parts, metalling/ grinding and polishing of rotary fan, replacing gasket, toping up compressor oil upto the level re-assembling, installing, connecting, commissioning and testing complete all as specified and directed. |
| 25 | All as per Serial item No 24.00 here-in-before but air blower of capacity 5 HP, 1500 RPM 3 phase. |
| 26 | S&F in repairs moulded case circuit breaker 100 Amps 415 Volts (with thermal release), 3 pole 50 KA breaking capacity after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. |
| 27 | S&F in repairs moulded case circuit breaker 125 Amps 415 Volts (with thermal release), 3 pole 50 KA breaking capacity, after disconnecting all electrical connection incl. taking down old unsv one complete all as specified and directed. |
| 28 | S & F 3 Pole Power Contactor with accessories suitable for electric motor 12.5- 20 HP capacity with necessary electrical connection by using proper size of single core copper wire complete incld taking down/ removing old U/S ones with necessary electrical connection complete as directed.by Engr-in-Charge Make : L &T/Siemens or equivallent. |
| 29 | Supply and fixing of following parts of Air compressor/blower:- |
| 30 | Safety valve for air compressor |
| 31 | Ball bearing No 6304 |
| 32 | Air/Oil filter of compressor |
| 33 | Gate valve 1/2 |
| 34 | Pre Nylon Heavy duty pipe 1/2\"\" |
| 35 | Fan belt |
| 36 | Supply and fixing gland packing for sewage pumps, sluice valve etc |
| 37 | Supply and fixing well cap in two parts made out of mild steel plate for covering tube well internal dia 250 x150 mm depth duly welded with locking arrangement making holes for passing 4 to 10 Sqmm flat submersible cable complete all as pecified and as directed |
| 38 | S & F Water pressure gauge 7kg or 10 kg x 100 mm dia Make: RMCO or equivalent. |
| 39 | S& F Spare Parts for RC-11 Dosing Pump Model: rc-11 Capacity 06 LPH/04 KGS pressure. Make : RMCO or equivalent. |
| 40 | Solinoid Coil with body. |
| 41 | Pulsar Circuit |
| 42 | Speed/Stroke Knob |
| 43 | Injection Check Valve (NRV) |
| 44 | Suction/Discharge Tube. |
| 45 | Discharge or Suction valve including Ball & Ring seal |
| 46 | Pressure relief valve including Ball & Washer |
| 47 | Liquid Head(P P) |
| 48 | Diaphragm( Teflon faced) |
| 49 | Foot Valve Assembly |
| 50 | Ball(Ceramic) |
| 51 | NRV spring(Teflon coated) |
| 52 | Ring Seal (Teflon) |
| 53 | Supply and Testing of following water test kit :- |
| 54 | Supply and Testing of Chlorine Test Kit with coloured ample complete with all testing fitments and OT solution in rexene finish Box. |
| 55 | Supply and Testing of pH Test Kit (electronic, digital and pocket type) |
| 56 | Supply and Testing of Hardness Test Kit with necessary fitments and testing solution in rexene finish wooden Box. |
| 57 | Supply and Testing of Iron Test Kit with necessary fitments and testing solution in rexine finish Box. |
| 58 | Supply and Testing of Turbidity meter electronic, Digital type range upto 1000 NTU. |
| 59 | Supply and Testing of TDS meter electronic, Digital and pocket type. |
| 60 | Supply and Testing of following water testing solution :- |
| 61 | Supply and testing of OT solution for chlorine test (500 ml each) |
| 62 | Supply and testing of Iron Test solution (3 btls X 500 ml each) |
| 63 | Supply and testing of Hardness Test solution (3 btls X 500 ml each) |
| 64 | Supply of Calcium Hypochlorite dry free flowing and free from lumps,Toxic& undesirable substance, should not induce substances beyond acceptable limit as given in IS 10500(2012) for treatment and disinfect water of packing capacity 45 KG in each drum having min 55% chlorine content in granular form,calcium Hydroxide Max 4%,sodium chloride max 15% and particle size (passing through 1.70 mm IS sieve) fortified with corrosion inhibitors and anti scalants for drinking water disinfection. Note : Bidder should submit the corrosion inhibitor and Anti scaling agent certificate of particular OEM must be ratified of E-in-C\"s latest policy. |
| 65 | Supply of chlorine tablets contained in plastic cylindrical sealed disposable sanitiser refill (dia 2.5 inches ± 0.5 inches height 10 inches ± 0.5 inches) for disinfection of drinking water with arrangement for controlled release of disinfactant in water, suitable for operation through dosing system. Make : Declibac (Type Stequa 411 AE)/ Equivalent Note : The product media should have heavy metal contaminants below tolerance limits & must pass the acute toxicity test (confirm to non toxicity for mammalian cells) and safe for human health safety point. |
| 66 | S & F First Aid Kit ( With all medical items inside pre fitted Lock/ Mountable Metal Cabinet with size 36 cms L x 26 cmW x 12 cm D. Note: The followings medical items shall be available inside the First Aid box.Contd... |
| 67 | a) Small Size Sterilized Dressing- 12 Nos b) Medium Size Sterilized Dressing- 8 Nos c) Large Size Sterilized Dressing- 8 Nos d) Large Size Burn Dressing- 6 Nos e) Antiseptic Solution 100 ml-1 Nof) Scissor-1g) Adhesive Tape 1/2-2 Nosh) Sterilized Eye Pad- 8 Nosj) Aspirin Tablets- 30 Nosk) Burn Ointment 15 gm- 1 Nosl) Eye wash cup- 1 Nosm) Snakebite lancet-1 Nos |
| 68 | n) Potassium Permaganate Crystal- 1 Noso) Safety Pins- 20 Nosp) Cotton wool 10 mg-2 Nosq) Tourniquet-1 Nosr) Roller Bandage 5 cm-3 Noss) Roller Bandage 10 cm-1 Nost) ORS Powder 21.8 gm- 2 Nosu) Electrolyte Powder 21.8 gm- 2 Nosv) Digital Thermometer- 1 Nosw) Antiseptic Cream-1 Nosx) Band- Aid 19*72 mm-10 Nosy) Dusting Powder-1 Nosz) Crepe Bandage 5 cm* 4 mtr-1 Nosaa) FAK Guidebook- 1 Nosab) FAK Box- 1 Nos |
| 69 | S&F, including fabrication installation of Electrical Shock Treatment Chart in 450 GSM Backlit Printing framed inside top cover glass of size 3\"x2\" fixed with the help of supporting clamps/ nuts& blots fitted to wall with Iron base frame which includes strip lighting along outer periphery all as directed by Engr-in-Charge. (Sample is available with AGE E/M Office). |
| 70 | S&F, including fabrication installation of Electrical/ Water distribution system in 450 GSM Backlit Printing framed inside top cover glass of size 3\"x2\" fixed with the help of supporting clamps/nuts& blots fitted to wall with Iron base frame which includes strip lighting along outer periphery.Name of the installation/Location to be written on Board all as directed by Engr-in-Charge.(Sample is available with AGE E/M Office).Note : Approval of each Distribution System shall be taken by the contractor before fabrication. |
| 71 | Surface dressing not exc. 15cm deep in soft loose soil. |
| 72 | Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft loose soil. |
| 73 | M&L for PCC (1:3:6) type C-2 using 40 mm grade crushed stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 74 | M&L for Brickwork with subclass B bricks straight or curved on plan exc 6m mean radius, built in CM(1:4) complete all as specified and as directed. |
| 75 | Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm in soils all as specified and directed. |
| 76 | Removing excavated material exc. 250mtr but not exc. 500mtr and depositing where directed. |
| 77 | M&L for 15 mm thick rendering in CM (1:6) on other than fair face of brick or concrete surfaces finishing even and smooth without using extra cement. |
| 78 | M & L for preparation of new plaster surface of walls etc and applying three coats of white washing complete all as specified and directed. |
| 79 | M&L for preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paintover a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 80 | M&L for Mild steel angle, flat work as in posts and struts in fencing including cutting tops to shape as directed, drillingholes, notching for wireetc, flat iron fillets (for secruing wiremesh etc) including all necessary drilling, bolting or riveting etc conforming to Fe -290-GdeE-165 complete all as specified & as directed. |
| 81 | S&F 3 mm dia PVC coated galvanised mild steel chain link fencing of mesh size 100 x 100 mm fixed with string bolts including provn of binding wire etc complete all as specified and directed. |
| 82 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings Fe 410-W (Gde-E- 250) quality-B(exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete |
| 83 | Supply and fixed Rubber electrical insulation mat of size 1mtr x 2 mtr x 10 mm ISI marked. |
| 84 | Supply and installation of 1.1 KV single phase in door resin cast CT of ratio 100/5 5A class 5.0, burden 5 VA. |
| 85 | M&L for repair in replacement of Battery of 12V, 150 Ah @ C5 having 04 years Warranty all as directed by Engineer-In-charge. Make : Amaron / Exide |
| 86 | M&L for repair in replacement of Submersible pump set for borwell of Discharge capacity 30 to 65 Cum/hr and Head range from 60-80 mtr, 5 star rated all as directed by Engineer-In-charge.Make : KSB/ Kirloskar/ Crompton |
| 87 | Earthing complete with galvanised steel earth plate electrode 60 cm x 60cmx6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level. connecting to the Galvanised iron earth strip 32x6mm size by means of bolls, nuts, check nuts and washers of galvanised iron and earth strip protected by provision of GI medium grade pipe 40mm bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone agregates with 40mm thick cover of RCC (1:2:4) reinforeed with XPM weight not less than 4 Kg/Sqm) and frame of angle iron 40x40x6mm with lugs 02 Nos and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering , perforated at bottom. 1.75 metre long placed on top edge of earth plate. charcoal and common salt filled 150mm thick all around each plate, test point made out of 40x8mm flat iron galvanised with fixing arraangement, funnel wire mesh and earth work in any type ofsoil returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electical plate -3 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. |
| 88 | Testing of treated/ Raw water at 3 AFSR, Kahikuchi and MES Area pump house, Following parameters is tested on regular basisfrom any recogonised Govt lab or authoeised lab and Testing certificate is submitted to GE AF Borjhar Complete as directed by Engr in charge PH, Turbidity, Odor, Iron, Fluoride, Arsenic, Alkalinity, Calcium, Magnesium, Res. Chlorine,Sulphate, Chlorine, Sodium, Manganese, total hardness, Mercury, Lead, Cadmium, TPC at 22 degree Celcious, Escherichia Coli, Coliform Bacteria, Fecal streptocous, complete all as specified and directed. |
| 89 | Supply and fixing in repair of FRP Solution preparetion cum settling tank Cap-170 Ltrs with Lid, port, inlet /outlet/ drain connection, level gauge, sludge deposition facility etc and fitted with 900 RPM motor & PVC agitator combined with 100 Ltrs Cap. Dosing/storege tank with lid port hole, inlet / outlet/ drain connection, level gauge etc Make : RMCO (Model No-CDMPS-1015) or equivalent as approved. |
| 90 | Supply and fixing in replacment of Cheminject RMPS Series Plunger Type Chemical Dosing Pump reciprocal gear operated splash pump are positive displacment type ,which are designed to pump at practically constant flow retes up to 4000 LPH against a wide range of various discharge pressure (hIgh or low) icluding Stainer, Suction valve, NRV etc and make to functional with all assecceris which are required to be deemed including the quoted rated, of Cap 30 Ltrs/Hrs at 10 Kg Back Pressure Model No -RMPS 11 Make : RMCO |
| 91 | Material & labour for two coat of weather coat/ Cement based paint on RCC Over head tank of approx height of 25 Mtr, befor painting scraping of old paint is to be carried out and painting includes pillor, Doors and written of the capacity of Over Head Tank etc of RCCOver head tank complete all as directed by Engr -in-charge. Note : Rate quoted shall inclussive necessary scuffolding for paint work. |
| 92 | M&L for repair in replacement of GI strip of earthing and making proper earth testing point from pole, panels and transformer of size (32x6mm) and as directed by Engineer-In-charge. |