}

Tender For Provision Of Bathroom/Toilets For Ors Single Living Accommodation In Gr Unit Under Ge (W) Pathankot., pathankot-Punjab

Tender Notice

52290346
Tender For Provision Of Bathroom/Toilets For Ors Single Living Accommodation In Gr Unit Under Ge (W) Pathankot.
Tender
Indian
Punjab
Pathankot
02-12-2025

Tender Details

Tender For Provision Of Bathroom/Toilets For Ors Single Living Accommodation In Gr Unit Under Ge (W) Pathankot.; 1 Surface dressing in loose / soft soil n exc 15 cm deep complete all as specified and as directed. 2 Surface excavation in any type of soiln.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out 3 Excavating in any type of soil in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out 4 Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and as directed. 5 Removing excavated materials( soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed. 6 M&L for Plain Cement Concrete Type D-2 1:4:8 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed. 7 M&L for Hardcore broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15cmrammed to a true surface complete all as specified and directe. 8 M&L for 75 mm thick Cement concrete type D-1, 1:4:8 (20mm graded crushed stone aggregate) as in sub floor, Sub bases, floors and pavings etc complete all as specified and as directed. 9 M&L for 100 mm thick Cement concrete type D- 2, 1:4:8 (40mm graded crushed stone aggregate) as in sub floor, Sub bases, floors and pavings etc complete all as specified and as directed. 10 M&L for 25 mm thick Cement concrete type B-1, 1:2:4 (20mm graded crushed stone aggregate) as in sub floor, Sub bases, floors and pavings etc to receive the tile complete all as specified and as directed. 11 M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-40 Grade including 25mm thick compacted bed of coarse sand cushion , compacting and proper embedding/ layingof inter locking paver blocks into the sand bedding layer , filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.all as specified and as directed by Engr-in-Charge. 12 M&L for Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges o, in lintels upto1.5m clear span,cills,steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided water troughs and the like including weathering,slightly rounded or chamfered angles and throating, as directed 13 Formwork to sides of concrete foundations, footings, bases of columns, rafts raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; vertical or batter, finished rough surfaces of concrete, complete all as specified and directed. 14 Formwork to Square, rectangular or polygonal sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed. 15 Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed. 16 Formwork to sides and soffits offloor or roof beams, beam haunch ings, girders, bressummers,lintels, cantilevers, shelvesincluding sup- ports, overhangs, etc. also splays between floors andbeams, etc.complete all as specified and as directed. 17 M&L for TMT bars 6mm to 8 mm cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified and as directed. 18 M&L for TMT bars 10mm dia and over cut to length, bent to shape required including bending, cranking etc and binding with and including MS wire (annealed) not less than 0.9mm dia, complete all as specified & directed by Engineer-in- charge. 19 M&L for Reinforce cement concrete M-25 (Design mix) Foundations, including rafts, footings, basesfor columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. 20 M&L for Reinforce cement concrete M-25(Design mix)as in Slabs supported on walls, beams and columns in floors, roof slab, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. 21 M&L for Reinforce cement concrete M-25(Design mix)as in Beams,Plinth/Roof beam cantilevers, bressummers,lintels over1.5m span complete all as specified and as directed. 22 M&L for Reinforce cement concrete M-25(Design mix)as in Columns,pillars, piers, posts and struts complete all as specified and as directed. 23 M&L for brick work with sub class B Bricks (using old size bricks) straight or curved on plan exc 6m mean radius, built in CM 1:6, complete all as specified and as directed. 24 M&L for Brickwork withsub class B Bricks old size brick, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified and as directed. 25 M&L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces wall in cm 1:6 to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed. 26 M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces of wall in cm 1:4 to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed. 27 M&L for Rendering 5mm thick on fair faces of brick work or concrete surfaces in cm 1:3 to be finished even and smooth (without using extra lime or cement) complete all as specified and as directed. 28 Supply only `Liquid Water Proofing Compound complete all as specified and directed by Engr-in-charge. 29 M&L for preparation of newly plaster surfaces of walls and applying two coats of oil bound distemper over a priming coat of chalk whiting, on plastered surfaces, preparatory to distempringcomplete all as specified. 30 M&L for preparation of newly plaster surfaces of walls and applying two coats of cement base paint over a priming coat of alkalies resistance priming paintcomplete all as specified. 31 M&L for preparation of newly plaster surfaces of walls and applying three coats of white wash over ceiling complete all as specified and as directed. 32 S&F Coloured Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 20 mm thick screed bed in CM 1:6 complete all as specified. 33 S&F Coloures Glazed ceramic tiles in vertical surface 350x 250x 7-8 mm/ 450X 350X 7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including rendring of10mm thick cement plaster in CM 1:3 on fair faces of brick work or concrete surfaces complete 34 S&F 20 mm dia medium grade GI tubing with all fitting and fixed to wall, ceiling or laid in floors etc complete all as specified and as directed. 35 S&F 15mm dia medium grade GI tubing with all fitting and fixed to wall, ceiling or laid in floors etc complete all as specified and as directed. 36 M&L for Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 toends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubing or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete all as specified and directed 37 S&F vitreous china wash down water closet pan (Pedestal Pattern ) white including fixing bolts, plastic water closet seat, white, closed pattern, solid type with flat bottom, and cover and mild steel chromium plated hinging device complete and including making good to floor to match with adjoining surfaces complete all as specified and as directed 38 S&F vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests including provision of lime concrete bedding, making good to floor and all fittings (excluding flushing cistern and flush pipe) complete all as specified and as directed. 39 S&F vitreous china under counter wash basin with fixing accessories, ovalshape snow white of size 560 x 400 x 205 mm, incl 32mm dia brass chromium plated waste coupling and including waste pipe complete all as specified and as directed.Make: Oval Cat no. S2030103 of Jaquaror equivalent in any of the make mentioned in list of product. 40 S&F Viterous China urinal, half stall type, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and waste coupling fit to urinal and including 60mm long brass screws,with urinal waste pipe pointing around urinal back in cementincluding waste / Urinal pipe complete all as specified and as directed. 41 S&FUrinal spreader of CP any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and as directed. 42 S&F Vitreous china urinal partition white of size 310x700 mm complete all as specified and as directed. 43 S&F brass chromium plated tubular towel rail 20mm dia D type 60cm long between flanges complete all as specified and as directed. 44 S&F PVC10 ltrs capacity valveless syphonic action type low level flushing cistern including flush pipe, cantilever brackets incluiding taking down existing cistern etc complete all as specified and as directed. 45 S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and as directed. 46 S&F Pillar taps fancy type cast copper alloy chromium platedwith capstan head without letter Hot or Cold waterscrewed down for 15 mm diairon pipe complete all as specified and as directed. 47 S&F 15mm bore dia of pipe bib taps cast copper alloy, fancy type chromium plated, with capstan head screwed down, high pressure screwed for iron pipe or brass ferrule complete all as specified and as directed. 48 S&F stop valve / angle cockfancy type cast copper alloy chromium plated with long shank and cup(concealed type) capstan head serewed down, high pressure for 15 mm dia iron pipe complete all as specified and as directed. 49 S&Fbrass chromium plated health faucet with 1m long PVC tube & wall hook. screwed for 15mm dia bore iron pipe or2 in one tap complete all as specified and as directed. Make: ALD -563 Jaquar orequivalent in any of the make mentioned in list of product complete all as specified and as directed. 50 S&F brass chromium plated toilet roll holder with flap complete all as specified and as directed. Make : AKP - 35753P of Jaquar orequivalent in any of the make mentioned in list of product. 51 S&F CP Grating with hole /with out hole of dia 125 mm complete all as specified and as directed. 52 S&FGun-metal, globe or gate valves 15mm bore, with iron wheel head, screwed both end for iron pipe 53 S&F looking mirror bevelled edges of selected quality glass mounted on 6mm commerical ply or AC building board with aluminium frame around and fixed to wooden plugs with CP brass screws complete all as specified and as directed. 54 S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails MS frame shall be coucred with heat moulded wood grain printed PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheet for top rail, lock rail & bottom rail on either side as gap insert for top rail bottom rail panelling of wood grain printed PVC sheetto be fited in the MS frame welded/seald to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement suppling & fixed in the framed site as per specification & drawing complete all as specified and as directed. 55 S&F PVC door frame of size 50mmx47mm made out of 5mm wood grain printed PVC sheet reiforced withMS squre tubeas perspecification and drawing complete all as specified and as directed. 56 M&L for Powder coated (of approved color) aluminium sections as in frame & shutter of windows, ventilators as in sliding / openable / louvers / fixed/hangtype with and including necessary rolling for smooth moving & locking arrangement, etc. fixed to wall including, preparation of disturbed portion both sides (internal & external surfaceof wall) match with existing surface treatment and all sides of aluminium frame shall be sealed with silicon sealent (inner/outer face) complete all as specified as directed by Engr-in-charge. 57 S&F 250mm longAluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed 58 S&F aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed. 59 S&F 150mm size,extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed. 60 S&F 100 mm sizeSS butt hinges with galvanised mild steel hinges complete all as specified and as directed. 61 S&F 110 mm bore PVC (SWR) pipes single socketedin any length with rubber ring joints fixed to walls complete all as directed. 62 S&F 110 mm bore PVC (SWR) pipes single socketedin any length with rubber ring joints laid in trenches complete all as directed. 63 S&F 110 mm bore PVC (SWR) bends complete all as specified and as directed.. 64 S&F 75/100mm PVC(SWR) floor trap plain withgrating incl jointing with solventcement complete all as specified and as directed. 65 S&F 110 mm bore PVC (SWR) cowl complete all as specified and as directed.. 66 S&F 110 mm bore PVC (SWR) accessible door bends complete all as specified and as directed.. 67 S&F 5 mm thickplainglass sheet, pin head type or-dinary quality and glazing with oil putty / beading in square n exc 0.5 sq. m in each pane, complete all as specified and as directed. 68 S&F 3 mm thick tinted/frosted sheet glass figured, pin head type or-dinary quality and glazing with rubber neoprene packing for aluminium door/windows in square n exc 0.5 sq. m in each pane, complete all as specified and as directed. 69 S&Fstainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples or using metal nut and bolts complete all as specified and directed. 70 M&L for 16-18mm thick Granite (of any type) work(table rubbed and polished)in steps, jambs, pillars, win dow-cills, cooking plat forms and like in cementmortar (1:4) including point ing in white cement (1:2) using marble dust with admix ture of pigment to matchwith shade of granite complete all as specified and as directed. 71 S&FRotational moulded polyethlene water storage tanks white in colourthree layers of 1000 ltrs capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including 20mmBall valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and including inlet and outlet tank nipple of 20 mm boreand fixed. (Minimum weight 20mm-210 gms complete all as specified and as directed. 72 M&L liquid water proofing treatment to RCC roof slabin following procedure : (a) Prepare the surface by cleanining with concrete surface grinder/ wire brush and a high pressure water jet and ensure that it is free of dust, oil and loose particles. Damaged portions, hollow area must be repaired with epoxy mortar and repair cracks of old concrete by cutting V groove, corners and joints of drain pipes, channels etc. treated with epoxy mortar prepared with epoxy primer (as per manufacturers instructions).(b) Laying 10mm thick rendering in Cement mortar 1:3 with liquid water proofing compound (as per manufacturer’s instructions) on fair faces of concreteroof surfaces, finished even and fair to receive treatment on roof Complete (c ) Applying three coats of polyurea waterproofing coating as per manufacturers instructions for maintaining minimum dry film thickness 1.5mm and elongation at break of free film of approx. 500% ± 50% and tensile strength at 14 days of 5MPa.(d)The materials shall be applied with brush or roller, complete in all respect as per the direction of Engineer-in-charge / Consultant. (Note:- minimum 6 hrs interval between two coat shall be maintained)(d) All auxiliary and accessories involved during application should be supplied by single manufacturer as a part of system.Note:- (i) Work to be carried out by authorized applicator and as per manufacturer’s instructions.(ii) Providing test with filling of water for continuous 48 hours if there is any leakage than entire treatment will be done again by contractor without any additional cost.(iii) The rate includes for filling cracks in existing roof with epoxy cement mortar using suitable bonding agent before laying cement plaster. 73 M&L for 150mm bore Reinforced concrete pipes(ISI marked), class NP3, laid and jointed in cement mortar complete with collars, laid in trenches and testedcomplete all as specified and directed by Engr-in-Charge. 74 M&L for Concrete bed type D-2, 1:4:8 (using 40mm graded crushed stone aggregate) to150 mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested;complete all as specified and as directed. 75 M&L for Providing factory precastce- ment concrete type B1 1:2:4 (20 mm graded aggrgate) as in but in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces 76 Sch A Part-I E/M Portion:-M&L for point wiring for one light/one fan controlled by one switch with 1.5 Sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H 1100 volte grade cable, withand including PVC rigid concealed conduit (ISI marked) with all fittings including sheet steel/CI terminal box of adequate size including 1.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly, complete all as specified and directed.Note:- 1. connection of cable with MCBs/switch sockets shall be done through proper size copper /brass thimbles.2.Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible. 3.Proper colour coud will be used for wiring as per the electrical rule and as directed. 77 All as per Srl item No 76 here-in-before but for 5 pin 5 amps socket outlet on the independent board controlled by one switch SP, one way 5 Amp, 240 Volts. complete all as specified and directed. 78 All as per Srl item No 76 here-in-before but for 5 pin 5 amps socket outlet on the sameboard with other switch complete all as specified and directed. 79 M&L for point wiring with 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with in and including PVC concealed conduit heavy duty with all fittings including anodise pressed steel sunken box with bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 2.5 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface tomatch with the existingsurface complete all as specified and directed. 80 M&L for point wiring with 4 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable with in and including PVC concealed conduit heavy duty with all fittings including anodise pressed steel sunken box with bakelite laminated sheet ISI marked suitable for 5 pin 15 amps socket outlet ,including 4 sqmm PVC insulated unsheathed multistrand copper conductor FRLS-H cable as earth continuity conductor connected to comman earth dolly in and including cutting chiseling for concealed piping and making good disturbed surface finishing the surface tomatch with the existingsurface complete all as specified and directed. 81 S&F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed. 82 S&F switch piano flush type one way 15 amps SP 240 volts complete all as specified and directed. 83 S&F socket outlet 2 in 1, 3 pin 5 amps flush type 240 volts complete all as specified and directed. 84 S&F socket outlet 2 in 1, 5 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed. 85 S&F lamp holder/batton holder/angle holder insulated body with bakelite back plate suitable for fittings complete all as specifiedand directed. 86 S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed. 87 S&F CFLs with LEDLamp, B22type ,12 watt,complete all as specified and directed. 88 S&F energy saving decorative LED boxtype 20 W, 6500K,cool white, Lumen efficiency 110 lumen/watt, light fitting PVC housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver complete with all accessories prewired and making connections with twisted flexible copper cable of suitable size from ceilling rose/PVC connector to light fittings complete all as spd and directed by Engr -in -charge. 89 M&L for providing/ cutting the round/ square hole of required size in wall finishing thedistrubed surfaces as per existing finishes complete all as spd and S&Fing MS ventilating fansSingle phase, 230 volts 300 mm or 12” H.D EX Fan (900 RPM) complete and supply and grouting the ragged bolts in wall, fixing the frame on the exhaust side (outer surface of the wall) and connecting with and including PVC insulated copper cable suitable size from ceiling rose to exhaust fan motor and writting MES No. with black synthetic enamel paint 2.0 cm high complete all as spd and directed by Engr-in-charge. 90 S&F sheet metal enclosure MCB distribution board, double door with IP-43 protection single phase 240 volts 8 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases in wall for fixing DB and making good the distributed wall surfaces to match with existing specification complete all as specified and directed. 91 S&F MCB SP 240 volts any rating from 6 to 40 amps, B cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. 92 S&F MCB SPN 240 volts any rating from 6 to 40 amps,B cruve with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed. 93 S&F energy saving , surface mounted, bulk head luminaire 10 watt with PDC aluminium housing and polycorbonate diffuser with IP 66 protection complete including connecting up with three core twisted flexible suitable size copper conductor cable complete all as specified and directed by Engr-in-Charge. 94 S&F bldg secuirty light fitting energy saving high efficiency LED street light fitting 35 Watts, 5700 K, IP 66, having pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, prismatic polycarbonate cover complete including GI bracket of size 25 mm dia bent to shape having length not less than 0.9 mtr fixing with clamp etc and making connections using suitable size copper cable from ceilling rose/ PVC connector to light fittings or as directed by Engr-in-chrage. 95 S&F sheet metal encloser with MCB DB single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp 240 volt complete with one single pole MCB 20 Amp C curve complete all as specified and directed 96 Supply and installation of the electric water storage heater of ABS body type, 25 ltr capacity with rated power 2KW, 5 star rated, vertical type, thermally insulated mild steel tank with glass line coating inside the tank alongwith glass lined incoloy heating element with anti corrosive magnesium anode, NRV, thermostat, indicators and temperature adjustable knob including steel braided flexible connection for pipe of size 15mm bore with GI hexagonal adopters/nuts on both sides for inlet (cold water supply) & outlet (hot water supply) and including provision of wall mounting arrangements and mounting on wall with suitable size of anchor bolts with complete connection of water including testing after installation complete all as specified and as directed. 97 M&L for earthing complete with galvanised steel earth plate electrode , 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level)withtop edge of the platenot less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point , GI tubing 15 mm bore light grade protection pipe , GI watering pipe 20mm bore light grade with funnel and wire mesh , charcoal ,salt packed around the earth plate and precastPCC 1:2:4 (Nominal mix ) reinforced with XPM having weight not less than 4 kg /sqm including suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover including earth workin any type of soil , removal of surplus soil to a distancen.exc 50m and connecting , testing on completion completeall as shown on electricplate No 05 of SSR -2009 Part I and connecting to existing earth test point complete all as specified and directed or including testing on completion.(Note: Excavation and earth work is deemed to be included in the rates quoted). 98 Supply, laying and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq. mm 2 core complete all as specified 99 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed. 100 Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified. 101 Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. 102 M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified(Note:-Punned thickness shall be measured and paid) 103 M&L for brick covering equal to length of bricks as mechanical protection to cable with well burnet sub class ‘B’ bricks laid as directed by the Engr-in-Charge. 104 S&F GI tubing light grade 50 mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole including fittings /clamp complete all as specified and directed. 105 M&L for galvanised steel tubing medium grade,25 mm bore with all fittings and fixed complete to walls and ceiling or laid in floor all as specified 106 S&F gun metal gate valve with iron wheel head, screwed both ends for iron pipes of 25 mm bore all as specified and as directed. 107 M&L for cutting/drilling of 50/80mm GI pipe for connection of 20mm GI pipe including all required accessories and earth work if required complete allas specified and as directed by Engr-in-Charge.

Key Value

Document Fees
INR 500 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail