}

Tender For Provision Of Defi Single Jcos Accommodation At Dappar., dappar-Punjab

Tender Notice

52288734
Tender For Provision Of Defi Single Jcos Accommodation At Dappar.
Tender
Indian
Punjab
Dappar
02-12-2025

Tender Details

Tender For Provision Of Defi Single Jcos Accommodation At Dappar.; 1 Total amount of Sch A Sec-I ( BUILDING WORKS ) Lump sum price worked out by the contractor for BUILDING WORKS as listed in schedule A Part-I 2 Total amount of Sch A Sec-II (SITE CLEARANCE, SITE DEVELOPEMENT & MISC. EARTH WORKS) Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPEMENT & MISC. EARTH WORKS as listed in schedule A Part-II 3 Total amount of Sch A Sec-III (INTERNAL WATER SUPPLY WORKS) Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in schedule A Part-III 4 Total amount of Sch A Sec-IV (INTERNAL ELECTRIFICATION WORKS) Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in schedule A Part-IV 5 Total amount of Sch A Sec-V (SEWAGE DISPOSALWORKS ) Lump sum price worked out by the contractor for SEWAGE DISPOSALWORKS as listed in schedule A Part-V 6 Total amount of Sch A Sec-VI (ROAD, HARDSTANDING AND CULVERTWORKS ) Lump sum price worked out by the contractor for ROAD, HARDSTANDING AND CULVERTWORKS as listed in schedule A Part-VI 7 Total amount of Sch A Sec-VII ( AREA DRAINAGE WORKS ) Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in schedule A Part-VII 8 Total amount of Sch A Sec-VIII (RAIN WATER HARVESTING WORKS) Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKS as listed in schedule A Part-VIII 9 Total amount of Sch A Sec-IX (EXTERNAL WATER SUPPLY WORKS) Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in schedule A Part-IX 10 Total amount of Sch A Sec-X (EXTERNAL ELECTRIC SUPPLY WORKS & LIGHTNING PROTECTION) Lump sum price worked out by the contractor for EXTERNAL ELECTRIC SUPPLY WORKS & LIGHTNING PROTECTION as listed in schedule A Part-XI 11 Total amount of Sch A Sec-XI (LIFTS WORKS) Lump sum price worked out by the contractor for LIFT WORKS as listed in schedule A Part-XII 12 Schedule ASection-XII (Misc Items of Works) Note :This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. 6 siginifies this fact only. 13 SUMMER APPLIANCESSupply, installation,testing and commissioning of self standing Water cooler fully stainless steel,puff insulated body, electric driven single phase 230 Volts, 50 Hz havingstorage capacity of 80 Ltrsand nominal cooling capacity of 40 Ltrs per hour with reciprocating compressor, eco friendley R-134A refrigernt, externally mounted thermostat for easy regulating temperature with extra large stainless steel water tray for fast drainage of water complete all as specified and as directed. 14 Supply, installation,testing and commissioning voltage stablizer for automatic operation, single phase naturally air cooled indoor type and designed for input varriation between 170 V to 290 V with output voltage stablized at 230 V with accuracy of + 2.5% and of capacity 2.0 KVA complete all as specified and as directed. 15 Supply, installation,testing and commissioning Desert Air cooler, electric drivensingle phase having having nominal air flow capacity of 4500 Cum per hour factory made out of MS sheet powder coated, electric driven capacity 170 watt, 230V (single phase ), having approx storage capacity of 60 Ltrs with MS fabricated standmade out of 40 x 40 x 5mm angle frame duly grouted in wall, painted with 2 coats of synethetic enamel paint over a coat of red oxide complete all as specified and as directed. 16 HOT WATER SUPPLYWater heaters(Geyser) vertical storage type,electric driven,closed vented type 230 Volts (BEE 5 star rated marked and equivalent latest EER/SEER rating) of capacity 25 Ltrs,2000 Watt ,50HZ with overheat auto cut-off thermostat provision, energy saving high quality PUF insulation, adjustable knob for temperature settings between 25 degree celcius to 75 degree celcius to get the desired temperature. Inner tank made of extra thick superior cold rolled sreel, earth leakage circuit breaker (ECLB) including 2 Nos PVC connections of size 15mm dia and 900 mm long, grouting nuts, bolts, washers, making electric connection, complete all as specified and as directed. 17 LIFTS Design supply, install testing & commissioningpassengers lift, speed 1.0 metre/sec, lift withsingle speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS 14665, suitable to serve G + 03 upper floors with ACVariable Voltage &Variable Frequencydrive(VVVF drive) completewith all standardaccessories, simplex automatic & manual dual controlledoperation with/without attendant, centre openingdoors with door drive(electric motor driven mechanism), slidingstainless steel doors, automatic rescue device(ARD) system, 3D infra red sensor in full height ofdoor & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floorlanding door) completeall as specified and directed.( Refer Particular specification Clause 40 for specifications). 18 Material & Labour for earthing complete with copper earth plate 60 cm X 60 cm X 3.15 mm thick electrode buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to copperearthing lead wire of 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel including excavation and earth work in any type of soil ,and removing surplus soil to a distance not exceeding 50 metres ,GI pipe light grade 40mm bore for protection of earth wire upto 7.5 metre from earth plate electrode and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt in alternate layers (each layer shall be 15 cm thick) , GIfunnel and wire mesh, 20mm dia GI pipe light grade for watering including necessary excavation and earth work, PCC 1:2:4type -B1 and 40 mm thick RCC M-25 (Design Mix) coverwith handle reinforced with 8 mm dia mild steel reinforcement at 15 cm c/c spacing in both ways with handle of 8 mm dia bar for fitting , pit cover, CI frame,all as shown and specified in electrical plate No 3 of SSR Part I complete all as specified and directed. 19 NOTES APPLICABLE TO SRL ITEM NO. 18 ABOVE : (i) The cost of earth strip GI / copper and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate.(ii) The earth chamber shall be constructed 50 cm away from the edge of earth pit and cost of the cost of excavation & earth workis deemed to be included in the quoted rate. (iii) The new earthing so constructed must have resistance value below 2 ohms. If aforesaid resistance value is not achieved, contractor shall make proper addition/alteration to the newly constructed earthing at his own cost. 20 LIGHTNING PROTECTION & DG SET Material & Labour for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized iron earth strip of size 32mmx6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel including excavation and earth work in any type of soil ,and removing surplus soil to a distance not exceeding 50 metres ,GI pipe light grade 40mm bore for protection of earth wire upto 7.5 metre from earth plate electrode and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt in alternate layers (each layer shall be 15 cm thick) , GIfunnel and wire mesh, 20mm dia GI pipe light grade for watering including necessary excavation and earth work, PCC 1:2:4type -B1 and 40 mm thick RCC M-25 (Design Mix) coverwith handle reinforced with 8 mm dia mild steel reinforcement at 15 cm c/c spacing in both ways with handle of 8 mm dia bar for fitting , pit cover, CI frame,all as shown and specified in electrical plate No 3 of SSR Part I complete all as specified and directed. 21 NOTES APPLICABLE TO SRL ITEM NO. 19 ABOVE : (i) The cost of earth lead /stripof GI/copper and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate.(ii) The earth chamber shall be constructed 50 cm away from the edge of earth pit and cost of the cost of excavation & earth workis deemed to be included in the quoted rate. (iii) The new earthing so constructed must have resistance value below 2 ohms. If aforesaid resistance value is not achieved, contractor shall make proper addition/alteration to the newly constructed earthing at his own cost. 22 Supply , installation, commissioning and testing of silent CPCB approved 30 KVA TPDiesel Generating Set having diesel engine Liquid cooled with minimum 42 BHP, Electric start, four stroke, cold starting, TCI Aspirated, compression ignition, totally enclosed diesel engine with electronic governor , direct coupled with 30 KVA Three Phase alternator at 1500 RPM, 0.8 lagging power factor, providing Three Phase 415Volts suitable for 50 Hz, H class insulated winding, Close-direct-coupled, Self-excited and self-regulated type, screen protected, mounted on rigid MS sheet channel base-frame. The alternator shall confirm to IS: 13364, IS: 4722, BS5000, IEC: 34 and suitable for tropical condition. having fitted inside Canopy, fabricated out of 1.6 mm CRCA Sheet, cubical type, totally enclosed, Powder Coated, Control Panel and all accessories in- housed in a acoustic enclosure – sound proof canopy. (A). Alternator :-Standard design alternator rated at 30 KVA net output at site after considering derating as per site conditions for chandigarh area at 0.8 (lag) power factor AC,3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class H and voltage regulation of+ 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000 and shall be inposition to generate supply with frequecy regulation with in + 1% tolerace. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/5000/ IS - 4722. (i) Insualation class - H (ii) Temparature rise Class - H (iii) Excitation : Self Excited 23 DG SET (Contd....)(iv) Regulation performance: The voltage is kept constant with + 1%, manual voltage adjustment within + 5%(v) Frequency regulation + 1% (B) Diesel Engine: - Adquate capacity of Diesel engine as accepted by the accepting officer based on manufacturers technical details water cooled to drive independently above alternator and after considering derating as per site conditonsfor chandigarh area after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection,cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:-(i) Fly wheel with housing (ii) Cooling system :- Moulded radiator with fan & belts.(iii) Cooling Water pump : - Centrifugal type belt driven (iv) Exhaust System :- Exhaust System complete with exhaust piping of MS light grade 150mm dia upto 1 meter away from the enclosure, covered with asbestos rope and aluminium foil complete within the enclosure for safe exhaust without transforming vibration to the wall of the enclosure with Exhaust gas turbo charger type, Exhaust manifold Silencer : Residual type Bellows(v) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governer for 1% speed /frequecy regulation, Fuel filters, Fuel hoses. (vi) Lub oil System :-Lubricating oil filter, Lubricating oil pump (vii) Air Intake System :- Air intake Manifold,Air cleanler dry type 24 DG SET (Contd....)(viii) Governor :- Electronic Governor(ix) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator.(C) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi-stranded leads of suitable length fromself starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified of Make as per OEM.(D) Starter gear ring:- Start and stop push button, Ignition key / Switch, Handling and operation : Salient features of accessories shall be as under.Radiator with blower fan, Corrosion inhibitor coolant, Paper element filters for fuel, lub oil and by pass. Electronic governor controlled direct fuel injection system, Fly wheel housing and fly wheel.(E) Generator Monitoring Control Panel : - Comprising of all standard items as mentioned under this schedule or as per standardpractice ignition key switch and start / stop arrangement, indications for Engine parameters, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display including suitable size MCCBs and multifunctional meter.(i) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine. (ii) Coupling arrangement : - Flexiable coupling, fly wheel to suit flexiable coupling. (iii) Accessories :- AVM Pads built or separtely mounted to manufactrer base frames. 25 DG SET (Contd....)(iv) Base Frame : - Made out of ISMC 250 of sturdy design made of MS channel with necessary reinforcement and predetermined holes. (v) MS pipe line to and from the fuel tank to the DG Set.(F). Civil Works :-All civil works including PCC plat form as per manufactures design also 30 cm above the ground. The depth of the foundation and PCC as recommended by the manufacturer. (G) Rubber Mattingof LV grade 19mm thick of suitable size chequred type ISI marked to be laid in front of control panel should be provided.Note:- The contractor shall arrange for artificial load for testing for final testing of DG Set at site and the cost is deemed to be including in above offer.(H) Accoustic Enclosure:- Manufactured by OEM suitable for 30 KVA DG Set.(i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board. (iii) The generating setbattaries and control panel should be inside the enclosure. (iv) Fuel tank should be inside tothe enclosure body(v) The accoustic should be composite in construction and fully assembled integral unit. (vi) The battaries should be placed inside the enclosure beside the DG Set on a suitable inlsulatedplat form.(vii) The DG Set should be provided with external Emergency stop push button. 26 DG SET (Contd....)(viii) The enclosure should be suitably illuminated by suitable capacity of LEDfittings. (ix) The noise level should be 75 db (A) at 1m under free field conditions. (x) The accoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Genset Green. The base frame should be painted with epoxy based black shade.(xi) Fuel tank as per manufacturer recommendation with inlet and outlet connections and fuel level indicator.(xii)Base frame made out of suitable MS channel duly reinforced and provided with adequate numbers of anti-vibration pads to ensure minimum vibration as recommended by manufacturer.NOTE : -(i) TheGenerator set prime mover shall produce minimum 42 BHP at 0.8 PF with 10% overloading.(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed.(iii) The quoted rate shall be deemed to be inclusive of first filling of lubricant oil. (iv) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of half an hour on 10% overhead in presence of representative detailed by Accepting Officer; including FOL, all arrangements are to be made by the contractor for tests.Note : The consolidated rate for Srl No. 20.00, 20.10 ,20.20, 20.30 & 20.40above shall be quoted against Srl No. 20.00 of BOQ. 27 Galvanised iron strip 32 x 6mm buried in ground, complete all as specified and directed 28 EXTERNAL WATER SUPPLYCuttingexisting CI/DI pipe of 100 /150 mm dia and reducing to required length in position for inserting of new tees branches, collarsbends etc for 150 X 80 X 150 mm sizefor taking branching connection complete all as specified and as directed.Note : Cost of tee with jointing material shall also be including in quoted rates. 29 Construction of brick masonary valve pit of size 900 mm x 900mm x 900 mm (Internal size) thickness of walls shall be 23cm in brick work in cement mortar 1:6 internally plastered in cement mortar (1:6) and externally plastered in cement mortar (1:4) over 15cm thick PCC 1:4:8 type D-2 having 15cm offset around, including 4 cm thick coping in PCC 1:2:4 type B-1 on the top of the brick wall and 3mm thick mild steel sheet cover and angle iron frame of size 40 mm x 40mm x 6mm including provn of suitable hold fasts to hold the frame, locking arrangement and lifting handle, duly painted with two coats of synthetic enamel paint, over a coat of red oxide primer, complete all as specified and as directed. 30 EXTERNAL ELECTRIC SUPPLYSupply/Laying / fixing, jointing, testing and commissioning, LT under ground cable 1100 volts grade XLPE insulated & PVC sheathed cable heavy duty armoured, with multistranded aluminium conductor laid in trenches/ ducts/ pipes/fixed on walls/poles complete all as specified and directed of following sizes:-. 31 3.5 core 120 sqmm 32 3.5 core 35 sqmm 33 Sand Cushioning (dry river sand) to underground cable for cable protection provided with layers 8cm deep before laying and 15 cm after laying the cable complete all as specified and directed . 34 Supply and fixing LED Solar street light fitting20 Watt includinggalvanized steel pole in built, lithium ion battery, solar panel, charge controllerwith dusk down sensor complete all as specified and directed. Note- Excavation and Earthwork shall be measured and paid separately. 35 Supply and fix cable route indicator made up ofRCC M-20 grade of dimension450 X300 x 100 mm with suitable foundation including embossing of letters like LT cable with paint of suitable colour , proper finishing and smoothing of surface complete all as specified and directed . 36 Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, , Outdoor cubical type floor mountedfactory made double doordust and vermin prooffabricatedout of CRCA sheet not less than 3.15mm thickfixed on angle ironframemade out of 60x60x6 mm with cable chamberfor individual feeders for incommingand outgoing connections,including suitable size cable gland,one set of indicator lampRYB with switch and fuse, multifunction intelligent panel meter etc and with the followings. (Main panel) 37 INCOMING:-(a)MCCB 4P, 100Amps, 16 KA, adjustable type thermal release - 1 Nos (Incoming)(b) Suitable size of TPN Alumium bus bar with colour coading- 1 SetOUTGOING:-(a) MCCB 3 POLE, 415V. Adjustable type thermal release,25-100 Amps, 16 KA - 3No (For Lift , Building load and spare )(b)Microprocessor based Multifunctional digital meter with CT to display parameters like voltage,current,frequency,power factor etc. for three phase , consistingtamper proof system - 1 nos.(c) Indicator lamp -03 Nos 38 Material & Labour for earthing complete with galvanized steel earth plate 60 cm X 60 cm X 6 mm thick buried vertically in ground to depth not less than 2.25 metres deep below ground level, with top edge of earth plate not less than 1.5 m below ground level, connected to galvanized iron earth strip of size 25 mmx 4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel including excavation and earth work in any type of soil ,and removing surplus soil to a distance not exceeding 50 metres ,GI pipe light grade 40mm bore for protection of earth wire upto 7.5 metre from earth plate electrode and connected to continous earth lead on pole/test point, supplying and laying charcoal dust common salt in alternate layers (each layer shall be 15 cm thick) , GIfunnel and wire mesh, 20mm dia GI pipe light grade for watering including necessary excavation and earth work, PCC 1:2:4type -B1 and 40 mm thick RCC M-25 (Design Mix) coverwith handle reinforced with 8 mm dia mild steel reinforcement at 15 cm c/c spacing in both ways with handle of 8 mm dia bar for fitting , pit cover, CI frame,all as shown and specified in electrical plate No 3 of SSR Part I complete all as specified and directed . 39 NOTES APPLICABLE TO SRL ITEM NO. 29 ABOVE : (i) The cost of earth lead /stripof GI/copper and GI pipe for protection of earth lead/strip upto 7.5m is included in the quoted rate.(ii) The earth chamber shall be constructed 50 cm away from the edge of earth pit and cost of the cost of excavation & earth workis deemed to be included in the quoted rate. (iii) The new earthing so constructed must have resistance value below 2 ohms. If aforesaid resistance value is not achieved, contractor shall make proper addition/alteration to the newly constructed earthing at his own cost. 40 RAIN WATER HARVESTINGLoose filling with aggregates of broken stone or boulders of gauge 20 to 50 mm in soakage pits, soakage wellcomplete all as specified and directed . 41 All as per item no. 30 above here-in-before, but gauge 5 to 10 mm. 42 Drilling pilot bore hole of 150mm dia by rotary drilling method (Direct/ reverse) through rig machine for injection well in any kind of soil strate or rock including disposal of surplus soil/rock to a distace not exceeding 50 metre complete all as specified including deploying required rig machinery.T&P equipment etc complete including transporting of all materials like rig machine, tool and plants, collection of logsamples (drilling/ cutting) and to maintain drill time log book ,complete all as specified and directed 43 Reaming of 150mm pilot bore hole to 250mm bore with direct circulation rig machine/ reverse rotary circulation method in any kind of strata of soil/ rock from ground level to 100 Metre depth below ground level all as specified and directed .Notes for item No 32 to 33.(a) The following activities are to be carried out and reports as mentioned to be submitted by the contractor which is deemed included in the rates quoted. (i)Taking the sample of strate at every 3.0 interval and every change in strata and preparation of litho logs based on these samples, (Cost of provision of sample strate box size 1200 x 750X100mm of specification as directed by GE/ AGE(I) shall be deemed included in the quoted rates.(ii)Preparation of drill time log and submitting to department .(b)The change upper or lower limit of boring from ground level with a particular diameter of drill not accountedto any deviation and rates quoted against these items is only applicable even if drilling depth varies from Sch `A and nothing extra is admissible on this account. 44 Supply, assembling, jointing lowering and fixing in postion PVC plain casing pipe, heavy duty of size 150mm borewith a thickness 7.5 to 8.5mm conforming toIS-4985 having male threads at spigot end and female threads at socket endscrewed and socket type in all jointing accessories complete all as specified and as directed. 45 Supply assemnling, jointing, lower and fixing in position PVC screen casing pipe, heavy duty of size 150mm, wall thickness 7.5 to 8.5 mm conforming to IS-4985 having male threads at spigot and female threads at socket endscrewed andpocket type in all jointing accessories complete all as specified and as directed. 46 PVC bail plug assembly suitable for 150 mm nominal bore PVC casing pipe internally threaded and jointed with casing pipe complete all as specied and as directed 47 Mild steel hosing clamp, made out of 12mm thick MS flat bend to shape for 150mm bore casing pipe with necessary bolts. Nuts and washers at ground level complete all as specified and as directed 48 PVC well borewell cap 8 mm thick, suitable for 150mm bore having internal threads complete all as specifed and as directed 49 Development of injection bore well by using air compressor of suitable capacity of removing the drilling mud and finer sediments in the surrounding of borewell screens complete all as specifed and as directed (5 hours for each well) 50 Supply and packing pea gravel of size 2 mm to 5 mm all around casing pipe and slotted pipe complete all as specified and as directed 51 INTERNAL ELECTRIFICATIONConcealed point wiring using approved colour coding as per IS, with 1.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H, drawn through and including heavy duty PVC conduit (minimum 20 mm bore size 2mm wall thickness) and conduit accessories ISI marked, PVC junction boxes ,modular GI metal sunken/flush boxes of thickness not less than 1.2 mm of any module from 2 to 18 modules with inner and outer modular cover plates etc,including 1.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H as earth continuity conductor to common earth & connecting to earth dolly for the following :- (Note-(i) Cutting/Chases of wall etc.deemed to be included in the quoted rates of this item (ii) Modular GI metal flush/sunken box along with modular base/front cover plate/blank plates are inclusive in the item rate wuoted (iii) Only switch, socket and fan regulators shall be measured and paid separately) 52 One light/exhaust/Call Bell point controlled by one, 1 way switch /Bell push 53 One fan point controlled by one ,1 way switch through fan regulator 54 One 3-Pin socket outlet point 6A on same board 55 One 3-Pin socket outlet point 6A on independent board 56 One light point controlled by two 2-way switches 57 Concealed point wiring using approved colour coding as per IS, with 2.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H, drawn through and including heavy duty PVC conduit (minimum 20 mm bore size 2mm wall thickness) and conduit accessories ISI marked, PVC junction boxes ,modular GI metal sunken/flush boxes of thickness not less than 1.2 mm of any module from 2 to 18 modules with inner and outer modular cover plates etc,including 2.5 Sqmm (nominal area), single core multistranded copper conductor of 1100 volts grade, ISI 694 marked, PVC insulated and unsheathed FRLS-H as earth continuity conductor to common earth & connecting to earth dolly for the following :- (Note-(i) Cutting/Chases of wall etc.deemed to be included in the quoted rates of this item (ii) Modular GI metal flush/sunken box along with modular base/front cover plate/blank plates are inclusive in the item rate quoted (iii) Only switch, socket and fan regulators shall be measured and paid separately) 58 MCB, SP, 6 to 32 Amp, 240 Volts, 6 KA, B curve, complete all as specified. 59 MCB, SPN, 32 Amp, 240 Volts, 6 KA, B curve, complete all as specified. 60 Vertical loadline DB 8 ways , double door, 415 volts suitable for MCCB 100 Amps, 4 pole as incommer, standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting, drilling holes for incoming and outgoing cables complete with IP-54 , complete all as specified and directed 61 MCCB, Four Pole , 415 Volts with capacity 100 Amps, 16kA, Ics 50% and Icu as per IEC 60947-II fixed type, complete all as specified and directed. 62 S & F LEDLights fittingsmirror type with high output diffuser 2 feet 10 W, 220 V ,AC decorative box type with driver, holder including LED Tubelight connecting up with three core flexible copper conductor cable of suitable size from ceiling rose , complete all as specified and directed. 63 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and all accessories including nuts , bolts, clamps etc , 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) , and neccessary electrical connections, complete all as specified and directed. 64 Supply and fixing exhaust fan made of sturdy Engineering plastic and sweep 300mm complete with louvers shutter, single phase AC voltage 230V, with energy efficient motor, pre-lubricated double ball bearings, minimum1200 RPM, 50 Hz Copper winding , complete all as specified and directed. 65 Supply and fixing new generational energy saving and environmental friendly long lifeLED building security light fitting 1X35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, high power LED as light source and lense embededPC cover having top opening separate driver compartment with IP 65 protection,and impact resistance of IK07, with all accessories, including suitable lamp bracket of 32 mm bore light grade GI pipe bend to shape,with impact and corrosion resistant including thermal management in multiple optics including MS clamp of required size and PVC cable 1.5sqmm twin-core from ceiling rose to light fitting, complete all as specified and directed. 66 M&L for LED bulb 7/9 watt, 230 volts AC, 50 Hz , Retrofit B22 base, complete all as specified and directed. 67 Supply and fixing LED lights fitting 1x 20 Watt 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, complete all as specified and directed. 68 Supply and fixing TV socket, complete all as specified and directed. 69 Supply and fixing RCBO- A Type (SPN- 2M) 32 Amps 30 mA (In accordance with IS 12640-2& IEC 61009-1) 240 Volt /415Volt , 50 Hz, with 10kA short circuit capacity, RCBO is designed for use in domestic , commercial and industrial distribution systems at most downstream circuit for ensuring protection from leakage current, short circuit & over load to the user for a particular circuit. In normal use, it is safe to use and free of threat to user as well as to the environment , complete all as specified and directed. 70 Supply and fixing Arc fault Detection Device (AFDD) 32 Amps, rated voltage 240 Volts, 50 Hz frequency, residual operating current 30mA, short circuit capacity 10kA, Type-A, residual making and breaking capacity 500 Amps, Electrical/Mechanical Endurance 10000 operations (made in india), terminal capacity 25 sqmm protection class IP-20, Protection class with enclosure IP-40, DIN rail mounting method, Vibration resistance 3g, shock resistance 40 mm free fall, complete all as specified and directed. 71 AREA DRAINAGE WORKSMaterial & Labour for filter media/packing material of clean course aggregate of size 20 to 40 mm wrapped with GI wire mesh of 0.56 mm nominal dia and average width of aperture 1.18 mm of size 150 X 150X 150 mm and fixed by suitable arrangement like nailing etc, and placed behind weep hole to prevent soil from entering the pipe and maintain water flow complete all as specified and directed. 72 SEWAGE DISPOSAL WORKSConstruction of conventional typeseptic tank for 20 users to carry sewage and sullage water, (excavation in any type of soil) PCC 1:4:8 below foundation vent shaft, connection etc complete in all respect as specified and directed. 73 Construction of soakage wells of size 2.4 metre X 3 metre depth , in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made ofBrick masonary in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size complete all as specified and directed .

Key Value

Document Fees
INR 2000 /-
EMD
INR 351600.0 /-
Tender Value
INR 2.76 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail