| 1 | Taking up or down unserviciable / old GI tubing any grade and fittings connections ( including dewatering of trench) and removal from siteall as directed by Engr-in-charge. |
| 2 | 15mm dia bore |
| 3 | 20 mm dia bore |
| 4 | 25mm dia bore |
| 5 | 40mm to 80mm dia bore |
| 6 | Taking up or down unserviciable / old GI tubing any grade and fittings connections including cleaning and re-fixing or removal from siteall as directed by Engr-in-charge. |
| 7 | 15 mm dia bore |
| 8 | 20 mm dia bore |
| 9 | 25mm dia bore |
| 10 | 40mm to 50mm dia bore |
| 11 | Supply & lay and jointing tubing medium grade galvanised iron pipes, ISI marked with all fittings such as bends, tees, elbows, nipple, unions, short pieces, sockets etc and laid in trenches all as specified of following sizes :- |
| 12 | 15mm dia bore |
| 13 | 20 mm dia bore |
| 14 | 25mm dia bore |
| 15 | 40mm dia bore |
| 16 | 50mm dia bore |
| 17 | 80mm dia bore |
| 18 | Taking up cast iron water mains with fittings ( including dewatering of trench) with spigot and socket ends and lead joint including burning out joints and recovering lead. |
| 19 | 100 mm bore |
| 20 | 150 mm bore |
| 21 | 200 mm bore |
| 22 | 250 mm bore |
| 23 | 300 mm bore |
| 24 | M&L for Caulkingexisting leaking lead joint includingjointing materials such as lead, lead wool, spurn yarnfor the following sizes of CI pipe lines complete all as directed. |
| 25 | 80 mm bore |
| 26 | 100 mm bore |
| 27 | 150 mm bore |
| 28 | 200 mm bore |
| 29 | 250 mm bore |
| 30 | 300 mm bore |
| 31 | M&L bends (any type, radius and angle) tapers any type (straight bend,increasing, decreasing or double socked etc) tee pieces , singlebranch, junction, double branch, cross ( all sockets or socket and spigot) collars, caps plugs suitable for the pipe upto 150 mm bore. |
| 32 | M&L bends (any type, radius and angle) tapers any type (straight bend,increasing, decreasing or double socked etc) tee pieces , singlebranch, junction, double branch, cross ( all sockets or socket and spigot) collars, caps plugs suitable for the pipe200 mm to 300 mm bore. |
| 33 | Taking down and S&F PVC Float valves , high pressure ,with polythene float and flynut complete ,screwed for iron pipe of size: |
| 34 | a)15 mm dia |
| 35 | b)20 mm dia |
| 36 | c) 25 mm dia |
| 37 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil for cleaning surface area and cutting shurbes/grass & bushes and remove the material at various installation at site. all as directed by Engr-in-charge. |
| 38 | Taking down unserviceablegun metal gate valves including S & F gun metal gate valves with iron wheel headscrewedbothend for iron pipe and fixed. |
| 39 | a) 20mm dia bore |
| 40 | b)25mm dia bore |
| 41 | c) 40mm dia bore |
| 42 | d) 50mm dia bore |
| 43 | Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth for laying of GI tubing / taking out of GI tubing and gettingout in |
| 44 | a) Soft /loose soil |
| 45 | b) Hard / dense soil |
| 46 | c) Soft disintegrated soil |
| 47 | Returning filling in including spreading levelling, watering and well ramming in layers n. exc 25cm with soil obtained from excavation complete all as specified and directed. |
| 48 | Removing excavated soil / material n. exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above the starting point. |
| 49 | Demolishing or dismantling Concrete in ground floors and pavings n exc 15 cm thickness |
| 50 | M&L for Cement concrete D-2 (1:4:8) using 40mm graded stone aggregates asin foundations, filling and mass concrete complete all as specified and directed. |
| 51 | M&L for replacement of butterfly valve dia including taking out existing existing unservercieable butter fly valve and making good to surface |
| 52 | a) 80mm dia |
| 53 | b) 100 mm dia |
| 54 | c) 125/150 mm dia |
| 55 | d) 200 mm dia |
| 56 | e) 50 mm dia |
| 57 | M&L for Construction of brick masonry valvepit inside measurement 1.2 m x 1.2 m x 90 cmin replacement complete with MS Sheet 3.00 mm thick cover and angle iron frame (40m x 40mmx 40mm)as per existing size including locking arrangement suitable for sluice valve 200 mm to 300mm and sheet cover with one coat of red oxideand two coatof Syntheticenamel paintand complete leveling refilling the unwanted existingtrenches ,as per ground requirement including demolition of existing/old valve chamber all as per direction by Engineer in charge. |
| 58 | M&L for Construction of brick masonry valvepit inside measurement 0.90m x 0.90m x 0.90m in replacement complete with MS Sheet 3.00 mm thick cover and angle iron frame (40m x 40mmx 40mm)as per existing size including locking arrangement suitable for sluice valve 80 mm to 150 mm and sheet cover with one coat of red oxideand two coatof Syntheticenamel paintand complete leveling refilling the unwanted existingtrenches ,as per ground requirementincluding demolition of existing/old valve chamber all as per direction by Engineer in charge. |
| 59 | M&L for MS Mechanical Joint clamp of (minimum thickness of 6mm) type,flap type,GP joint type/any type as per site requirement for CI,DI Pipe of size 80mm along with MS nut bolt washer complete all as specified and directed. |
| 60 | M&L for MS Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint for CI,DI Pipe of size 100mm along with MS nut bolt washer complete all as specified and directed. |
| 61 | M&L for MS Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type/any type as per site requirement for CI,DI Pipe of size 150mm along with MS nut bolt washer complete all as specified and directed. |
| 62 | M&L for MS Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type/any type as per site requirement for CI,DI Pipe of size 200mm along with MS nut bolt washer complete all as specified and directed. |
| 63 | M&L for MS Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type/any type as per site requirement for CI,DI Pipe of size 250mm along with MS nut bolt washer complete all as specified and directed. |
| 64 | M&L for MS Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type/any type as per site requirement for CI,DI Pipe of size 300mm along with MS nut bolt washer complete all as specified and directed. |
| 65 | M&L DI water pipes with spigot and socket ends including rubber gasket joint Class K7, in any length, including all fittings likes bend, elbow,tail piece,tee,reducer etc in trenches. |
| 66 | 100 mm bore |
| 67 | 150 mm bore |
| 68 | 200 mm bore |
| 69 | 250 mm bore |
| 70 | 300 mm bore |
| 71 | Taking out and S&F unserviceable CI sluice valve from exisitingposition by opening the nuts , boltsand breaking of valve chamberincluding necessaryearth work and excvation in any typeof soiland S & F CI sluice valve with PN rating 1:6 conforming to IS 14846 duly ISI markedwith iron wheel head HSS spindle andall other conected accessories such as gland packing, bolts, and nuts rubber gasket etc completeand making good the vlave chamber to match with the adjacent surface including brick/ PCC block works, plastering etc for the following sizes complete all as directed . |
| 72 | 80 mm bore |
| 73 | 100 mm bore |
| 74 | 150 mm bore |
| 75 | 200 mm bore |
| 76 | 250 mm bore |
| 77 | 300 mm bore |
| 78 | Taking out water sample in clean container gettng the same tested from NABL accredited LAB for chemical and bacteriological test complete as per IS 10500: 2012 standard for drinking water and in case of STP water suitable for gardening all as directed by Engr -in-Charge. |
| 79 | Repairing ofleakages/blockage GI pipeline of size 15 mm,20mm,25mmby replacing the Tees, bends, sockets, unions,nipple and providing the other materials required to complete the job including material,excavation and earth work either manually or by JCB complete all as per the direction of engr in charge.Notes:- a).Fitting required to rectify will be included in above item of size mentioned.b).Defect should be rectified within 24 hrs of intimation otherwise recoveryof rupees @ 300 per day will be carried out.c). contractor should be responsible to rectify any defects at any place including restricted area in AF lohegaon. |
| 80 | Repairing ofleakages/blockage GI pipeline of size 40mm,50mmby replacing the Tees, bends, sockets, unions,nipple and providing the other materials required to complete the job including material,excavation and earth work either manually or by JCB complete all as per the direction of engr in charge.Notes:- a).Fitting required to rectify will be included in above item of size mentioned.b).Defect should be rectified within 24 hrs of intimation otherwise recoveryof rupees @ 300 per day will be carried out.c). contractor should be responsible to rectify any defects at any place including restricted area in AF lohegaon. |
| 81 | Repairing ofleakages/blockage CI/DI pipeline of size 80mm to 100mmby replacing the Tees, bends, sockets, unions,nipple and providing the other materials required to complete the job including material,excavation and earth work either manually or by JCB complete all as per the direction of engr in charge.Notes:- a).Fitting required to rectify will be included in above item of size mentioned.b).Defect should be rectified within 24 hrs of intimation otherwise recoveryof rupees @ 300 per day will be carried out.c). contractor should be responsible to rectify any defects at any place including restricted area in AF lohegaon. |
| 82 | S&F Bib taps of size 15mm stainless steel crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed as per sample approvd by Engineer in charge. |
| 83 | Supply only Calcium Hypo Chlorite 65%chlorine content (Calcium based granular) |
| 84 | Servicing and Maintenance of Dry air compressor by OEM or as directed by Engineer in charge . Make:- ELGI22,Model EG22Notes :- servicing includes deep cleaning of equipment checking of electrical connection ,change of Oil and cupling connection,change all the parts as per OEM recommended 4000hrs kit. |
| 85 | Replacement of preFilter having flow rate 125 CFM as directed by Engineer in charge. Make :- ELGI22,Model 125 |
| 86 | Replacement of Fine Filter having flow rate 125 CFM as directed by Engineer in charge. Make :- ELGI22,Model 125 |
| 87 | Replacement of Carbon Filter having flow rate 125 CFM as directed by Engineer in charge. Make :- ELGI22,Model 125 |
| 88 | Servicing and Maintenance ofLaminar Cum Fume hood big size by OEM or as directed by Engineer in charge.Make :- Spire Automation and inovation india Model :- SAH-FH-14-BigNotes :- Testing certificates need to be furnished by the contractor. |
| 89 | Servicing and Maintenance of Horizontal laminar flow cabinet or as directed by Engineer in charge. Make :- Spire Automation and inovation india,Model :- H-11Notes :- Testing certificates need to be furnished by the contractor. |
| 90 | M&L for taking out unserviceable non return valve of size 150mm dia including nuts & bolts suitable flages welding work incl connected works completed all as specified and directed |