| 1 | Supply and errecting in replacement true vertical position steel tubuler poles 9 meter long complete withMSbase plate , MS pole cap, bolts nuts & screw as specified type 410 SP-31 with and including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion 2 coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed. |
| 2 | M & L forPCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of steel tubular pole incl form work complete all as specified and directed. |
| 3 | M & L for PCC (1: 4:8 ) type D-2 using 40mm graded stone aggregate as in bottom of pit for bed concrete of steel tubular pole incl form work complete all as specified and directed. |
| 4 | M & L for PCC ( 1:2:4) type B-1 using 20mm graded stone aggregate as in coping including all form work completeall as specified and directed. |
| 5 | M&L for MS cross arms bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed. |
| 6 | S & F in replacement for stringing, stretching and strengthening of overhead conductor (ACSR) on existing LT steel tubular pole including binding and jointing the conductor with and including 14 SWG binding wire complete all as specified and directed.Note :- Size of ACSR conductor shall be :-(a) 6/1 X 2.59 mm aluminium and 1 X 2.59 mm steel (Weasel)(b) 6/1 X 3.00 mm aluminium and 1 X 3.00 mm steel (Ferret) |
| 7 | S&F in replacement shackle type insulator, porcelain, vitreous, white, brown or green insulator of size 75mm height and 90mm dia for working pressure 1100 volts, LT complete with insulator bolts, washers and nuts complete all as specified and directed. |
| 8 | S & F stay assembly comprising GI stay bow 400 X 14 mm, GI steel stay rod 1800 mm long X 16 mm dia with nut-bolts, washers, GI steel plate 230 X 230 X 6 mm, two Nos. thimble, loop insulator of size 65 X 90 mm clearance of hole 16 mm, stay wire of GI stay strand of size 7 X 3.15 mm fixed to stay assembly and stay clamps including necessary excavation and earth work in hard / dense soil, PCC 1:3:6 type C-2 block complete all as specified and directed. |
| 9 | S& F in replacement for stringing, stretching and strengthening of GI wire 4mm dia on LT electric lines includingbinding, jointing etc all as specified. |
| 10 | M&L for earthing complete with galvanised steel,earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs belowground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handleto cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 11 | M&L for earthing complete with galvanised steel,earth plate electrode 600mm x 600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs belowground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised strip 32mm x 6mm as earth leadby means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handleto cover, GI protection pipe 40mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 40mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost. |
| 12 | Supply, laying, jointing and commissioning in replacement LT XLPE 1100 volts grade heavy duty cable PVC insulated, stranded aluminium conductor served with inner sheathing of PVC tape, armoured with GI steel or tape and over all PVC sheathing laid in trenches, floor through pipes,induct, on poleand roads etc of sizes 300 Sqmm3.5 core. |
| 13 | All as per item No. 12 here in before but 240 Sqmm3.5 core |
| 14 | All as per item No. 12 here in before but 185 Sqmm3.5 core |
| 15 | All as per item No. 12 here in before but 150 Sqmm3.5 core |
| 16 | All as per item No. 12 here in before but 120 Sqmm3.5 core |
| 17 | All as per item No. 12 here in before but 95 Sqmm3.5 core |
| 18 | All as per item No. 12 here in before but 70 Sqmm3.5 core |
| 19 | All as per item No. 12 here in before but 50 Sqmm3.5 core |
| 20 | All as per item No. 12 here in before but 35 Sqmm3.5 core |
| 21 | All as per item No. 12 here in before but 25 Sqmm4 core |
| 22 | All as per item No. 12 here in before but 16 Sqmm4 core |
| 23 | All as per item No. 12 here in before but 16 Sqmm2 core |
| 24 | All as per item No. 12 here in before but 10 Sqmm 2 Core |
| 25 | Taking out unserviceable LT cable of any type and size from pole/ wall/ trenches by disconnecting electric connections for repair/ replacement of cable complete all as specified and directed. |
| 26 | Excavation in trenches in hard/dense soil not exc 1.5 mtrs wide and not exc 1.5 m in depth for laying cables and getting out incl jointing bottom surface to the reqd level/ slope etc complete all as specified and directed. |
| 27 | Returning filling in incl spreading, leveling, watering and well ramming in layers notexc 25 cm in hard/ dense soil complete all as specified and directed. |
| 28 | Removing excavated material to a distance not exc 15 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point. |
| 29 | M&L for laying of fine river sand, free from sharp material for cable cushioning in trenches complete all as specified and directed. |
| 30 | M&L for brick protection covers laid over cables of sub class \"B\" bricks old size(230 x 115 x 75) mm complete all as specified and directed. |
| 31 | S&F plastic (moulded poly propeline) line phase separators for separating 5 Nos of over head line conductors length 1200mm with 25mm with fly nuts and clamps suitable for1100 volts grade LT electric lines of any size fixed with over head electric lines complete all as specified and directed. |
| 32 | Tightening / re-stringing of existing loose / broken ACSR conductor or any other type of conductor of any sizes and strengthening as required at site complete all as specified and directed. |
| 33 | M&L for GI pipe light grade with all fittings fixed to pole and laid to floor/ground for mechanicalprotection of cable of the size 80mm bore complete all as specified and directed. |
| 34 | All as per item No. 21 here in before but 50mm bore |
| 35 | All as per item No. 21 here in before but40mm bore |
| 36 | All as per item No. 21 here in before but25mm bore |
| 37 | Dismantling of existing LT pole any size/ type from foundation in necessary earth work including dismentling of concrete MS clamps nuts, bolts, earth wire, overhead lines conductor, insulators, gaurding cradles and other accessories complete all as specified and directed. |
| 38 | Dismantling of existing stay assembly any type/ size from its stay rod, cutting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete all as specified and directed. |
| 39 | Dismantling/taking out old ACSR/ copper conductor/ GI wire any size fromexisting over head lines incl disconnection complete all as specified and directed. |
| 40 | Dismantling/taking out insulator of any size/ type from existing electric LT lines complete all as specified and directed. |
| 41 | Dismantling/ taking outstreet light fitting any type/ cap complete with bracket all as specified and directed. |
| 42 | M & L for one coat of aluminium shade paint of approved quality including preparation of existing old painted surface of steel tubular poles LT complete including flat iron clamps, bracing , cross arms etc and numbering of poles with white synthetic enamel paint over a circular painted base and strip marking paint up to a height of 5 feet with black & yellow five bands with synthetic paint (strip of 1 feet height each) complete all as specified and directed. |
| 43 | Supply & Fixing LED street light fitting 35W pressure die cast aluminium IP66 roadway luminaire withhigh power LED as light sourceand electronic driverincluding GI bracket light grade 25/32mm and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 3 x 2.5 core completeall as specified and directed. |
| 44 | Supply & Fixing LED street light fitting 45 W pressure die cast aluminium IP66 roadway luminaire with operating range from 80V AC to 230 V AC with high power LED as light sourceand electronic drivermake in Havells with cat part no. ENDURASUNDOWNSL45WLED765PASYBOPCor equivalent make in Bajaj/crompton/philips including GI bracket light grade 25/32/40 mm and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 3 x 2.5 sqmm core complete all as specified and directed. |
| 45 | Supply & Fixing LED Flood light fitting 100 W230 V AC outdoor type pressure die cast aluminium IP66 luminaire with high power LED as light sourceand electronic drivermake in Havells with cat part no. JETALEGANZAFLS100WLED757P60DTOTGor equivalent make in Bajaj/crompton/philips with impact and corrosion resisant including clamp and GI bracket light gradeand provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 2 x 4 sqmm core complete all as specified and directed. |
| 46 | Taking down old U/S junction box and Supply and fixing Junction Box made up of High quality thermoplastic polycarbonate enclosure with IP 65 degree of protection, weather proof, corrosion proof, dust proof, insulted and shock proof, fire retardant non toxic material with internally embedded gasket with 10 Amp MCB and 4 nos terminal of size 200x160x98 mm of make hensel or equivalent make of Sintex/ Universal complete all as specified and directed by Engineer-in-Charge. |
| 47 | Taking out old U/S service connection cable for replacement including S&F service connection cable, 1100 volts grade heavy duty PVC insulated aluminium conductor, 10 Sqmm 2 core size, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mmsuspensionwire, one twin core cable flat or circular, complete all as specified and directed. |
| 48 | Taking out old U/S service connection cable for replacement including S&F service connection cable, 1100 volts grade heavy duty PVC insulated aluminium conductor, 16 Sqmm 2 core size, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mmsuspensionwire, one twin core cable flat or circular, complete all as specified and directed. |
| 49 | S & F in recplacement MCCB 4 Pole, 415 V, Adjustable type, 630 Amps with breaking capacity 36 KA complete all as specified and directed NOTE: Make and model of MCCB shall be as per sample/site requirement before purchasing material contractor shall take approval from Engr-in-Charge and if any necessary alteration work required in panel for fixing of mccb contractor have to carry out in quoted rate. Note : All MCCBsto be fixed within the LT Panels/Feeder pillars shall be ofthermal adjustable and magnetic setting type with Ics=Icu (100%), Quoted rates shall be deemed to be included of this and no claim what so ever on this account shall be admissible |
| 50 | All as per item No 34 here in before but cap 100 Amp,16 KA |
| 51 | All as per item No 34 here in before but cap 250 Amp,16 KA |
| 52 | All as per item No 34 here in before but cap 315 Amp,36 KA |
| 53 | All as per item No 34 here in before but cap 400 Amp,36 KA |
| 54 | S & F on pole / wall Nature switch02 EC with enclosure factory made suitable for 8 KW street light load single phase 240 volts and power contactor rating 40 Ampere with MCB 63 Ampere contactor and terminal block confirming to IEC – 60947 – 4 – 1 / IS – 13947 – 4 – 1 (Sensor alongwith pre-dawn switching off timer, 4 – 8 hours) infrared sensor based switch for intelligent outdoor street light control model No. SWADEEP – 02EC8kW1P, Make – KAKATIYA ENERGY SYSTEMS LTD. Or its equivalent approved make complete with and including mounting bracket, cable glands, openable doors with lock complete all as specified and directed. |
| 55 | M&L for trimming of tree branches including shrub,vegetation & saplings around LT/ HT over head line complete removed upto 3.0 mtr distance from over head line complete all as specified and directed by Engr-in-Charge. |
| 56 | M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping of pole / floor finished fair and even complete all as specified and directed. |
| 57 | S & F guard cradles, make to shape, hexagonal / rectangular or any other shape as required and directed, fabricated out of 4 mm dia GI wire including 14 SWG binding wire complete all as specified and directed. |
| 58 | Supply and Fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed. |
| 59 | M & L for Anti-climbing device,spikes type fabricated out of M.S bars (round, square and flat) including nut, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified |
| 60 | Supply & Fix in replacement for ELECTRIC SHOCK CHART (Electric shock & its management chart,written in both Hindi & English language) of standard size 70x50 cmdrawn on wooden/ cardboard/flex chart frame of approved size complete all as specified and directed. |
| 61 | Supply, fabricating and fixing of sheet metal enclosure made of 16 gauge MS sheet outdoor type of suitable size including fixing of MCCB of cap 200 Amp, 415 Volt, 50Hz, 4 pole, 36 KA, Ics=Icu (100%), AC supply with 300 Amp rated busbar on porcelain insulators for neutral link double door type with locking arrangement completewith MS angle iron frame of size 25 x 25 x 5mm with nut/bolts andPCC plateform work including painting with two coat of synthetic enameelled paint over one coat of red oxide/ primer complete all as specified and directed at site. |
| 62 | M & L for repair of old street light 25-50W capacity by replacing old U/S driver / LED plate or any other items as and when required on site and making it serviceable and fixing it on pole after repair complete all as specified and directed |
| 63 | M & L for repair of old street light/ flood light /High way light 60-150W capacity by replacing old U/S driver / LED plate or any other items as and when required on site and making it serviceable and fixing it on pole after repair complete all as specified and directed |
| 64 | Supply and fixing of LEDPost top 40Wwith IP 65 protection comprises of Spherical/Diamond shape diffuser cover, etc and all accessories including monkey cage of suitable size for protection of light, light grade GI pipe of suitable length and wire required for connectionsetc complete all as directed. |
| 65 | Supply & Fixing LED sensor based street light fitting 45 W pressure die cast aluminium IP66 roadway luminaire with auto dimming feature operating range from 80V AC to 230 V AC with high power LED as light sourceand electronic drivermake in Havells with cat part no. ENDURADUNBEAMSL45WLED757SASYTOPCSENSO or equivalent make in Bajaj/crompton/philips including GI bracket light grade 25/32/40 mm and provn of electric supply to fitting from source by means of PVC Sheathed multi-stranded aluminium conductor cable of 3 x 2.5 core complete all as specified and directed. |