Tender For Repair And Maintenance Of Pumpsets, Submersible Pumpsets, Misc Works, Cleaning And Disnfecting Ug Sumps, Oh Reservoirs At 2Wing And 9Brd Afs Pune Under Ge (Af) Lohegaon.; 1 Taking out the submersible pump/Openwell Submersible Pump set forrepairsand lowering down after repairs the submersible pump set of any capacity& of any type from the bore well to a depth of not exc. 70 mtrs including scrapping of the existingpaint of submersible pump set and applying two coats of anti corrosive paint over a coat of primer complete after repair / replacement of spares and commisssioning all as directed by Engr-in-Charge.NOTE: COST OF REPAIR SHALL BE MEASURED AND PAID AGAINST RELEVANT ITEM 2 Repairs to submersible Pump set of electric driven of any type make and capacity upto 5 HP incl rewinding of the motor with same gauge and weightof PVC insulated copper conductor incl renewal of thrust plate,CI bowl,pump shaft,impeller ,Bearing,strainer,bush cable gaurd etc. reassembling, testing and commissioningcomplete all as directed by Engr-in-Charge. 3 Repairs toNon clog ,Open well submersible Pump set of electric driven of any type make and capacity upto 5 HP incl rewinding of the motor with same gauge and weightof PVC insulated copper conductor incl renewal of Mechanical seal, Bearing ,thrust plate,CI bowl,pump shaft,impeller ,strainer,bush cable gaurd etc. reassembling, testing and commissioningcomplete all as directed by Engr-in-Charge. 4 Renewal of column pipe 50 mm dia heavy duty ISI marked ,10 feet lengthboth ends machine threaded with longthread heavy duty socket complete all as directed by Engr-in-Charge. 5 Replacement of unserviceablePVC weather proof cable and replacementwithnewPVC weather proofcopper cable for size3 core2.5 sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge. 6 Replace of non return valve gun metal 50 mm bore complete all as directed by Engr-in-Charge. 7 Replace of non return valve gun metal 150 mm bore complete all as directed by Engr-in-Charge. 8 Taking outold unserviceable MCCB 400/360 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,400 Ampsall as directed. 9 Taking outold unserviceable MCCB 250 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,250 Ampsall as directed. 10 Taking outold unserviceable MCCB 200 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,200 Ampsall as directed. 11 Taking outold unserviceable MCCB 160 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,160 Amps. 12 Taking outold unserviceable MCCB 100 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,100 Amps. 13 Taking outold unserviceable MCCB 63 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,63 Amps. 14 Material and labour for reparing/maintenance of existing electrical panel boards of pump sets by replaing worn out spares as starter/single phase preventor/relay /contactors MCCBs / MCBs / switch gear / cable glands/ lugs pin type,U type etc, cleaning of panel board, tightening of cable connection to avoid sparking, insulating bus bars bracket portion of conductor and to ensuring proper function of the panel board all as directed by Eng-in-Charge.NOTE: ( I ) Cost of spares as starter /single phase preventor/voltmeter/Amp meter/ relay / contactor /MCCBs/ MCBs / Switch gear / cable gland etc shall be measuredand paid against relevant item.(ii) Cost of lugs (pin type / U Type) ,insulation taps shall be included in quoted rate.(iii) Cost of fixing of spares shall deemed to be included in quoted rate. 15 Renewals/replacingthe followingspares to the existing elecrical panels complete all as directed by Engr-in-Charge. 16 S& F Voltmeter/Ammeter ,3 phase for range 0-200A Class-I, suitable as per existing 17 S&F in replacement of old unserviceable contactor ofcapacity upto 45 A,power operating voltage 415 V AC Capacity 3 pole with AC coil etc, suitable for existing contactor 18 S&F in replacement of old unserviceable contactor ofcapacity upto 95 A,power operating voltage 415 V AC Capacity 3 pole with AC coil etc, suitable for existing contactor 19 S&F in replacement of old unserviceable contactor ofcapacity upto 110/120 A,power operating voltage 415 V AC Capacity 3 pole with AC coil etc, suitable for existing contatctor 20 Over load relay 3 phase 415 Volts with range 16 to 45 A suitable for existing 21 Over load 3 phase 415 Volts relay with range 45 to 88 A suitable for existing 22 S& F Single phase preventor including Timer,415 V suitable for 100 HP motor. 23 Dismantling the centrifugal Pump/monoblock pumpset with motor of capacity Upto 3HP including disconnecting suction and delivery, power supply cable etc and reassembling same after replacement of necessary spares including greasing and painting of 2 coats of synthetic enamel paint using spray machine complete and replacing the same and testing all as specified and as directed by Engr in charge.NOTE: 1.In case of Centrifugal pump dismantling of pump and motor will be paid seperatly.2. In case of Monoblock pumpset pump/motor paid as one3. Spares such as bearing, bush, gland packing, coupling, capacitor will be measured & paid seperately 24 All as per item no 16 but for the capacity of 5 HP to 7.5 HP 25 All as per item no 16 but for the capacity of 10 HP to 15 HP 26 All as per item no 16 but for the capacity of 20 HP to 30 HP 27 All as per item no 16 but for the capacity of 40HP to 50HP. 28 All as per item no 16 but for the capacity of 60HP to 75 HP 29 All as per item no 16 but for the capacity of 90HP to 100HP 30 Supply only following worn out spares of Centrifugal/monoblock pump sets. 31 Bearing as per existing Size suitable for up to 3HP motor 32 Bearing as per existing Size suitable for 5HP to 7.5 HP motor 33 Bearing as per existing Size suitable for 10 HP to 12.5 HP motor 34 Bearing as per existing Size suitable for 20 HP to 30HP motor 35 Bearing as per existing Size suitable for 40HP to 50 HP motor 36 Bearing as per existing Size suitable for 60HP motor 37 Bearing as per existing Size suitable for 75 HP motor 38 Bearing as per existing Size suitable for 90 HP motor 39 Bearing as per existing Size suitable for 100 HP motor 40 Rubber bush/star rubber for coupling as per existing size for upto 30 HP motor 41 Rubber bush/star rubberfor coupling as per existing size forupto 50HP motor 42 Rubber bush/star rubber for coupling as per existing size forupto 75 HP motor 43 Rubber bush/star rubber for coupling as per existing size for upto90 HP motor 44 Rubber bush/star rubber for coupling as per existing size for upto 100 HP motor 45 Gland packingupto30 HP pump 46 Gland packing for 40 HP motor 47 Gland packing for 50 HP motor 48 Gland packing for 60 HP motor 49 Gland packing for 75 HP motor 50 Gland packing for 90 HP motor 51 Gland packing for 100 HP motor 52 Supply and replace old worn out couling with new Tyre coupling including machining,suitable to shaft dia of pump and motor of 5HP,12.5HP,20HP 53 Supply and replace old worn out couling with new Tyre coupling including machining,suitable to shaft dia of pump and motor of 30HP,40HP,50HP 54 Supply and replace old worn out couling with new Tyre coupling including machining,suitable to shaft dia of pump and motor of 60HP,75HP,90HP,100HP 55 Overhauling/servicing of Suction sweeper assembly trolley mounted with mud pump motor head 11.5 mtr make; Kirloskar for swimming pool complete all as specified and directer by Engr-in-charge. Notes:- including spares require for making the assembly serviceable deemed to be included in subjected item. 56 M & L for Rewinding ofelectric motor 3 phase, 415 Volt capacity 1/2HP TO 3 HP, incoming disconnection electric connections, dismantling slots, taking out burnt windings and rewinding the motor with super enameled copper wire as per existing size including insulating material and varnishing,greasing, painting with super enameled paint as per colour coad assembling the motor after rewinding and mounting at its ownposition, replacing the old nut,bolts and testing all as directed. 57 All as per item no. 28 but for the capacity of 5HP. 58 All as per item no. 28 but for the capacity of 10HP,12.5HP 59 All as per item no. 28 but for the capacity of 15HP,20HP. 60 All as per item no. 28 but for the capacity of 30HP. 61 All as per item no. 28 but for the capacity of 40HP 62 All as per item no. 28 but for the capacity of 50HP 63 All as per item no. 28 but for the capacity of 60HP. 64 All as per item no. 28 but for the capacity of 75HP. 65 All as per item no. 28 but for the capacity of 90HP. 66 All as per item no. 28 but for the capacity of 100HP. 67 Taking out unserviceable foot valve 80 mm dia from the UG sump and S & F new foot valve 80 mm dia ball typeincl rubbergasket, bolts, buts complete all as directed. 68 Taking out unserviceable foot valve 100 mm dia from the UG sump and S & F new foot valve 100mm dia ball typeincl rubbergasket, bolts, buts complete all as directed. 69 Taking out unserviceable foot valve 150 mm dia from the UG sump and S & F new foot valve 150mm dia ball typeincl rubbergasket, bolts, buts complete all as directed. 70 Supply and fix spares for pumps of DSM 150/45, DSM 100/36, DSM 125/45, DBHS 71 a) Impeller 1st , II nd Stage 72 b) Pump Shaft 73 c) Shaft sleave 74 d) Cartrige bearing DE/NDE 75 e) Through bush 76 f) Split gland coupling 77 g) Wear ring 78 h) Lantern Ring 79 h) Gland coupling 80 Supply and replacing Automatic DOL starter suitable up to5 HP submersible/ centrifugal pump set 81 Supply and replacing Automatic star Delta starter suitable 7.5 HP to 12.5 HP submersible/ centrifugal pump set 82 Replacement of nuts bolts to top & bottom cover of DSM pump 100 HP, 90 HP, 75 HP. 83 Supply & fixing in replacement LT cable 1100 volts grade PVC insulated multistranded copper conductor cable single core of size 35 sqmm. 84 M&L for cleaning and sterilization of inside the RCC/ Steel Underground/semi underground/Over head/Sedmentation/clear water sumpsof capacity.(a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b). Second stage is cleaning all the algae formation inside the tank .(c). Third strage is fresh water cleaning by high speed jet pump.(d). Fourth stage and first bacteria screening is decertification.(e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tnk and kills all suspended bacteria. (g)Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent. NOTE:-(i) COMPANY WILL SUBMIT LABORATORY TEST CERTIFICATE OF CHEMICAL USED BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE. (ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID.ENTERING SCALS AND THE SAME SHELL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE ROVISION . (III) STERILIZATION TEAM WILL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM03 MONTHS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. (IV) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE. NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE TO BE INCLUDED IN QUOTED RATE. NOTE:-THE WORK SHALL BE CARRIED THROUGH SPECILIZED AGENCY. 85 a)All as per Item no. 50 but for UG sump 100000 gallons capacity 86 b) All as per Item no. 50 but for UG sump10,000 gallons capacity 87 c)All as per Item no. 50 but for UG sump50000/30000 gallons capacity 88 d)All as per Item no. 50 but for O H Reservoir 300000 glns capacity 89 e)All as per Item no. 50 but for O H Reservoir 50000 glns capacity 90 f)All as per Item no. 50 but for O H Reservoir 150000 glns capacity 91 g)All as per Item no. 50 but for O H Reservoir 10000 glns capacity 92 h)All as per Item no. 50 but for O H Reservoir 25000 glns capacity 93 Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom ofthe static tank and clean surface by scraping and two coats of white cement washof capacity up to 10000 Glns complete all as specified and directed by Engr-in-charge 94 Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom ofthe static tank and clean surface by scraping and two coats of white cement washof capacity 10001 to 15000 Glns complete all as specified and directed by Engr-in-charge 95 Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom ofthe static tank and clean surface by scraping and two coats of white cement washof capacity 15001 to25000 Glns complete all as specified and directed by Engr-in-charge 96 Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom ofthe static tank and clean surface by scraping and two coats of white cement washof capacity 50000 Glns complete all as specified and directed by Engr-in-charge 97 S&F spare parts of chlorine dozers at various loaction as per directed by Engineer in charge 98 a) Pump head (ferrules 1/4 & duckbill included) 99 b) Pump Tube (pack of 5) 100 c) Injection cheack valve 3/8 101 d) 3/8 white suction/discharge tubing 102 e) Check valve duck bill only (pack of 5) 103 f) Connecting nut 3/8 104 g) Connecting nut 3/8 with adapter(pack of 5) 105 h) Ferrule 1/4 (pack of 24) 106 Supply and fix XLPE insulated, armoured heavy duty electric cable withn aluminium conductor, 1100 volts grade, cross-sectional area 95 sq. mm,3.5 core as per direction of Engineer in charge 107 Supply and fix wall mounted metal enclosure consist of On load change over of capacity 250 Amps 415V, 4 pole to be installed as per the direction of Engineer in charge 108 Supply and fix wall mounted metal enclosure consist of On load change over of capacity 400 Amps 415V, 4 pole to be installed as per the direction of Engineer in charge 109 Supply only drinking water testing Kit having testing water parameter like PPM of chlorine,PH etc . 110 Supply only O tolidine reagent for testing of chlorine content in drinking water as per direction of engineer in charge. 111 Supply only swimming pool water clarifier as per direction of Engineer in charge 112 M & L for installation of sign board made of 3mm ACP sheet pasted on Recto Reflective Sign Board ncluding Frame working, SS Steel, fitting & Concreting work complete all as per direction and approval of Engineer in charge (Notes :- Matter/colour to be printed shall be provided by Deptt) 113 Material & Labour for painting of Pumps inlcuding motor, suction & Discharge Pipes of capacity upto 12.5 HP 114 Material & Labour for painting of Pumps inlcuding motor, suction & Discharge Pipes of capacity upto 50 HP 115 Material & Labour for painting of Pumps inlcuding motor, suction & Discharge Pipes of capacity upto 100 HP