| 1 | Supplying with installation testing and commissioning of Hi -- wall 5 STAR rating non ducted split typeair conditioner of the following capacity with cordless remote complete with copper pipeand electrical connection cable,as approved by the Deptt.)up to 5 ftbetween the room unit and outdoor unit as directed by the department with variable compressor which adjust power depending on heat load, Annual energy consumption <=920 kwh, ISEER value>=5.00, 100%Cu condenser coil complete and as directed by department.(Make: Bluestar/LG/Carrier/Samsung/Hitachi) |
| 2 | 2.00 tonn, BEE 5 star rated inverter AC |
| 3 | Supply and installation of AC voltage stabilizer (voltage-130-260V) , with seven segment LED display ,12-10A capacity, thermal and overload protection complete as directed.(Make-Hitech/Vguard/Skyland) |
| 4 | Supply and installation of AC outdoor stand complete as directed. |
| 5 | Wiring for circuit/ submain rewiring wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 6 | 4 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 7 | 4 X 10 sq. mm + 2 X 4 sq. mm earth wire |
| 8 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductorsinglecorecableinsurface/recessedmediumand earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 9 | Group C |
| 10 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required |
| 11 | Single pole |
| 12 | Double pole |
| 13 | Supplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) |
| 14 | 4 way (4 + 12), Double door, 415 V TPN Double door MCB Distribution board. |
| 15 | SITC DOL contact starter for operation of lab equipmentscomplete with required (L&T /Havells/Legrand) enclosure complete as directed. |
| 16 | Supplying with fitting and fixing panel mounting open execution415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure)of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.25 KA 415V 50 Hz 4P MCCB(Schneider, Legrand, Siemens, Indo Asianmake) |
| 17 | 63A ,25 KA, 4P |
| 18 | Copper pipeincluding cable fitting ( 1/4,1/2,5/8) |
| 19 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm diaincluding accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.with charcoal/ coke and salt as required. |
| 20 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm) |
| 21 | Wiring to 2 X 5 A pin 6 Amps modular plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Havells or Equivalent Make as approved by the Deptt.) with flat 19 mmISI marked casing \"n\" capping (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in surface system, including two nos 5 pin 6A Modular type switch board with required face plate complete (Legrand/havellls/L&T/Indo asian Glint)with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm.cable to third pin of the plug socket etc. as required complete, when placed elsewhere. |
| 22 | Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. |
| 23 | 1 x 1.5 sq. mm |
| 24 | 2 x 2.5 sq. mm |
| 25 | 3 x 2.5 sq. mm |
| 26 | SITC of floor cable cover protector 1 channel PVC complete as directed by department. |