| 1 | Dismantling post or struts (Wood, steel or RCC) any section and size including taking out embedded portion in natural and making good disturbed, ground, complete all as specified and directed. |
| 2 | All as per item No 1.00 above but but post embedded in concrete, complete all as specified and directed. |
| 3 | Dismantling fencing wire mesh, any type, complete all as specified and directed. |
| 4 | Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 CM, complete all as specified as directed. |
| 5 | S&F of angle iron as in posts and struts for fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc) including all necessary drilling bolting or riveting etc and similar work conforming to Fe-290 gde E-165, complete all as specified and directed, |
| 6 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire, complete all as specified and directed. |
| 7 | Supply only chain link MS galvanised fencing, of size 4mm(8 SWG) 75mmX75mm, complete all as specified and directed. |
| 8 | Dismantling wrought iron or mild steel work of any description not otherwise provided for fencing post, complete all as specified and directed. |
| 9 | M&L for mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips Fe-410W (Gde E-250) quality A or Fe-290 (Gde E-165), complete all as specified and directed. |
| 10 | S&F of Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. complete all as specified and directed. (Each line wire to be measured). |
| 11 | S&F of 12 mm dia Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 cm long & n exc 10 cm, complete all as specified and directed. |
| 12 | M&L for Cement concrete Type B2 1:2:4 (40 mm graded crushed stone aggregate) in foundations, filling and mass-concrete, all asspecified and as directed. |
| 13 | S&F for framed work such asframed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or Fe 310-0, complete all as specified and directed. |
| 14 | M&L for RCC M-25(design mix) as in columns, pillars, piers, posts & strutsusing 20mm grded aggrigate, complete all as specified and directed. |
| 15 | M&L for Use and waste of Formwork to sides of pillars, posts, struts, piers, columns & stanchions incl fair finishes of surfaces, complete all as specified and directed. |
| 16 | M&L for 10mm dia & over TMT bars cut to length bent to shape required, including cranking, bending spirally or hooking for columns and binding with M.S wire annealed not less than 0.9 mm dia or securing with clips quality confirmining, complete all as specified and directed. |
| 17 | All as per Srl Item No 16.00above but 6 to 8 mm dia, complete all as specified and directed. |
| 18 | All as per item No 16.00 above herein before but 5mm diaand overup to 10mm dia bars as in strirupsspacers binders etc., complete all as specified and directed. |
| 19 | M&L for preparation of new untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 20 | M&L for Punched tape concertina coil 610 mm dia, made out of 2.60 mm dia (+ - 0.05 mm) high tensile spring steel wire (1620 MPA) withhaving zinc coating of 120 gms/Sqm as per IS: 228.Each coil having a min 50 turns (Circles), average weight 7.50 to 8 Kg (+ -) 5% including handle and spikes at both ends of coil erect and fixed on top of the \"Y\" Shape fencing, tied to the barbed wire/angle iron with suitable GI binding wires, complete all as specified and directed. Specifications : Diameter : 610 mmNo of Rounds : 50 roundsStretch of each coil : 6-8 meterTotal length of straight wire in each coil : 94.26 Meterbarb Length (mm) : 11.50 mm (+- 2.00 mm)Weight of each coil : 7.50 to 8 Kg |
| 21 | Returning filling in including spreading, levelling watering & well ramming in layers nexc. 25 Cm thick in each layers, complete all as specified and directed. |
| 22 | Removing excavated materialn exc 50m and depositing where directed at a level n exc. 1.50 M above the starting point. (including filling in floor) for any type of soil, complete all as specified and directed. |
| 23 | Demolition of cement concrete(unreinforced) of any description and in any position not other wise, all as specified and as directed by Engr-in-Charge. |
| 24 | M&L for Cement concrete type D2 (1:4:8) (Using 40mm crushed graded stone aggregate) in foundations, filling and mass-concrete, complete all as specified and directed. |
| 25 | M&Lfor Cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less, complete all as specified and directed. |
| 26 | M&L for forming 12mm thick expansion jointsof150mm thick filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, grade \"A\", complete all as specified and directed. |
| 27 | M & L for 20mm thick screed bed or bedding layer in CM 1:6 for laying floor tiles, complete all as specified and directed. |
| 28 | S&F of 35 mm thick precast PCC louvers and jallies in 1:2:4 type B-0 (Using 12.5mm graded crushed stone aggregate) incl suitable reinforcement all moulding etc set in CM 1:4, complete all as specified and directed. |
| 29 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), rubbish off the premises, complete all as specified and directed. |
| 30 | M & L for non skid Heavy duty endura tile 300x300x10-12mm thick joint free in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed in cement mortar 1:4, complete all as specified and as directed. |
| 31 | M & L for Natural stone wall cladding tile 10-12mm thick joint free in walls etcset and jointed in neat cement slurry and pointed in coloured cement to match over and including 15mm thick screed in cement mortar 1:4, complete all as specified and as directed. |
| 32 | M & L for Chequered cement concrete colouredtiles pre polished 30cmx30cmx22-25mm thick, set, jointedand pointed in neat cement slurry with grey cement and pigment in floors, complete all as specifiedand directed. |
| 33 | M&L for M&L 75mm thickPCC (1:4:8 Type D-2) using 40mm graded crushed stone aggregate as in sub baseof floor, complete all as specified and directed. |
| 34 | M&L for Supply and fixingProviding and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 35 | M&L for M&L 100 mm thickPCC (1:4:8 Type D-2) using 40mm graded crushed stoneaggregate as in sub baseof floor,complete all as specified and directed. |
| 36 | M&L for Supply and fixing Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete all as specified and directed. |
| 37 | Demolition of cement concrete(reinforced) n.exc as in man hole cover, all as specified and as directed by Engr-in-Charge. |
| 38 | M&L for PCC(1:3:6) type C-2 using 40mm graded stone aggregateas in foundation of man hole, complete all as specified and directed. |
| 39 | M & L for RCC type B1 1:2:4 (using 20mm graded crushed stone aggregate) as in slab forroofs, landing, balconies , canopies, deck slabs and in shelves and the like, complete all as specified and directed. |
| 40 | Use and waste of form work to soffits of suspended slabs such as roof, floor slabs, landing or similar work, n.exc 200mm thick (horizontal or sloping), flat rough finished, complete all as specified and directed. |
| 41 | Excavation in trenches not exc. 1.50m wide and not exc. 1.50m depth for foundation footingsplinth beams etc in hard/dense soil, complete all as specified and directed. |
| 42 | Demolition of brick or stone masonry, built in cement mortar incl all quoins, pillars, arches etc but excluding ashlar facing, complete all as specified and directed. |
| 43 | M&L for brick work with Sub class \"B\" brick straigth or curved on plan exc. 6m mean radius built in cm 1:6,complete all as specified& as directed by Engr-in-Charge. |
| 44 | M&L for reuses brick work with Sub class \"B\" brick straigth or curved on plan exc. 6m mean radius built in cm 1:6,complete all as specified& as directed byEngr-in-Charge.(Note: bricks obtain from item no 43.00 above). |
| 45 | Taking down Cement plaster on brick or stone walls incl raking out joints hacking for key & scrubbing down with water etc., compplete all as specified and directed. |
| 46 | M&L for rendering 15mm thick in cm (1:6)on other thanfair faces of brick workorconcrete surfacesfinished& even and smooth without usnig extra cement, completeall as specified and directed. |
| 47 | M & L for preperation of new plastered surfaces wall applying two coats of cement base paint over one coat of primer, complete all as specified and directed. |
| 48 | M&L for Prepration of old plastered surfaces of wall and applying one coats of cement base paint incl preparation ofold plastered surfaces, complete all as specified and directed. |
| 49 | M&L for Prepration of old plastered surfaces of wall and applying one coats of Appx exterior emulsion paint (Asian paint)incl preparation ofold plastered surfaces, complete all as specified and directed. |
| 50 | Note :- Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. |