Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | supply and Installation of Astral Lay-in , Steppe edge, having 1.8mm circular perforations - TOA 20%, galvanized mild steel core, ceiling panels, back lined with Soundtexblack acoustical fleece, 595x595x0.5mm having weight 3.5kg/m2, suspended by using 0.3mm thick Skelet TrelisT15 metal grid system. Skelet TrelisT15 ceiling grid system of 600x600mm module includes Skelet WA15W30,sectional thickness 0.4mm, with unequal flanges of 15/19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers.Then suspend the Skelet MT15W36,sectional thickness 0.3mm, with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Extra support to be added near jointing of two MT15 so that end cantilever should not be more than 150mm.Skelet CT15W12,sectional thickness 0.3mm, with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15.Finally Skelet CT15W06,sectional thickness 0.3mm, with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15W12 CrossT in direction parallel to the Main T15 to result in 600x600mm module. Astral Lay-in , steppe edge of size 595x595x0.5mm shall be placed into the grid size of 600x600mm. Technical Parameters Fire (Class) – A Acoustics –NRC upto 0.8 (For E600* Mounting) Climate (°C, RH) – 50, 90 Light reflectance (%) – 75 Green (VOC, RC %) – Low, 25 ,as per drawing and engineer incharge, etc., complete. |
| 2 | AREA |
| 3 | CLEAN ROOM FALSE CEILINGSupplying & Fixing of Progressive type Double skin modular 50 mm thick Ceiling wall panel made of 0.5 mm thick Powder coated sheets on both sides with PUF as infill of density 40 ± 2 kg /m3, GI Profiles for reinforcement along the periphery with bottom Aluminium track, and necessary arrangements, All Joints shall be sealed with clean room compatible Neutral Grade,as per drawing and engineer incharge,etc., complete. Rate to include all cutting necessary for Electrical, HVAC,FPS etc..as required. |
| 4 | AREA |
| 5 | PARTITION WORKSCLEAN ROOM PARTITIONSSupplying & Fixing of Progressive type Double skin modular 75mm thick Solid wall panel made of 0.5 mm thick Powder coated sheets on both sides with PUF as infill of density 40 ― 2 kg /m3, GI Profiles for reinforcement along the periphery with bottom track, and necessary arrangements, All Joints shall be sealed with clean room compatible Neutral Grade SiliconSealant.as per drawing and engineer incharge,etc., complete. Rate to include all cutting necessary for Electrical, HVAC,FPS etc..as required. |
| 6 | PARTLY GLAZED PARTLY SOLID -CLEAN ROOM PARTITIONSSupplying & Fixing of Progressive type Double skin modular 75mm thick Solid wall panel made of 0.5 mm thick Powder coated sheets on both sides with PUF as infill of density 40 ― 2 kg /m3, GI Profiles for reinforcement along the periphery with bottom track, and necessary arrangements, All Joints shall be sealed with clean room compatible Neutral Grade Silicon Sealant. as per drawing and engineer incharge,etc., complete. |
| 7 | CLEAN ROOM WALL PANELLINGSupplying & Fixing of Progressive type Double skin modular 75mm thick Solid wall panel made of 0.5 mm thick Powder coated sheets on both sides with PUF as infill of density 40 ― 2 kg /m3, GI Profiles for reinforcement along the periphery with bottom track, and necessary arrangements,(upto 1200mm ht & from 2400mm ht upto soffit)All Joints shall be sealed with clean room compatible Neutral Grade Silicon Sealant. as per drawing and engineer incharge,etc., complete.Rate to include all cutting necessary for Electrical, HVAC,FPS etc..as required.Supplying & Fixing of Progressive type Double Glazed Clean Room Partition with 5mm thk toughened Glass and Frame in Powder Coated Finish on G.I Sheet and necessary arrangements as per manufacture specifications for clean room applications (from 1200mmupto 2400mm ) Measurement for Billing will be taken from FFL to bottom of False Ceiling Level |
| 8 | FIXED GLASS PARTITIONProviding and fixing of fixed glass partitions with 12mm thick toughened glass using PT Standard fittings like PT 90/PT 92 of approved make at the top and bottom including cutting, making holes in glass and fixing on the granite counter top, the fittings in floors,etc and making the same good with necessary screws, sealants wherever required.as per drawing and engineer incharge,etc., complete. |
| 9 | DOUBLE SKIN PARTITION Providing and fixing of Gypsum Dry wall Double skin partition of 75 mm thick and the partition shall be of one layers of tapered edge 12.5mm thk Gyp board screw fixed with dry wall screw of 25mm at 300mm c/c to either side of 48mm studs. GI steel sections to be placed at 610 mm c/c in 50mm floor and ceiling channel 0.55mm thick having equal flanges of 32mm made of GI steel with jointsstaggered to avoid leakage through joints. Finally square and tapered edges of the boards are to be finished so as to have a flush look which includes filling and finishing with jointing compound, joint paper and 2 coats of Drywall top Coat suitable for Gypsum upto primer level. As per India Gypsum Specs. Note: Angle Bead to be used at external angles to get straight line finish & protection from normal impacts. Rate including materials, labours tools and tackles etc., As per Engineer/Architect/ client direction etc., complete ., |
| 10 | AREA |
| 11 | PATCH FITTING GLASS DOORProviding and fixing of fixed glass door with openable shutters using 12mm thick toughened glass. The fixed glass shall be fixed in position using PT patch fittings like PT 90/ PT 92 of Dorma make. The openable doors shall be fixed using top pivot PT 24, Top patch PT 20, bottom patch PT 10, corner lock US 10 with SS cover plates. The doors shall be fixed on floor spring model BTS 75V with SS cover plate. Pull handle shall be of size 600mm height x 32mm dia TGDI H 600. Necessary holes cutouts. etc to be provided as required. Cost to include drilling, cutting, necessary sealants, transportation etc in complete. The rate to be quoted will be inclusive of all the above including the cost of scaffolding, cost of floor springs and fixing cost for supply and erection of all hardware fittings such as S.S. handle two pairs, Equivalent for each door, all as directed by the Engineer in charge of the work and concreted civil works including chipping the floor, fixing the floor springs, making good the disturbed floor, all leads and lifts transport etc., complete. The glazing will be taped with7725SE-324 Frosted crystal film the details shown in the relevant drawings. The Frosted crystal film is to be supplied to the correct size and shape as indicated in the relevant drawing and the film is to be precut digitally with a plotter, brought to site and pasted over the glass. Any additional details required for shaping the film is to be obtained from the Architects in advance before precut the film.as per drawing and engineer incharge,etc., complete. |
| 12 | Entrance doors |
| 13 | Non-fire rated clean room doorsNon Fire rated Clean Room Doors are made up of 0.8 mm sheet thickness for leaf and frame sheet thickness will be 1.2mm. Leaf thickness will be 40mm. Insulating material will be Honeycomb. Finish will be GI Powder Coated of approved colour. Jamb size will be 50-100 MM. The rate to include SS Hinges,Door Closer STD Arm,Dead Lock,B To B Handle Or Push Plate One Side,Drop Seal,Flush Bolt for Double Door only,Double Glazed Vision of Toughened Glass (5mm) Size (600mmx600 mm) with Black Ceramic Border with all fixing Accessories,Kick Plate - One sided(Made from SS-304, provided with all fixing Accessories) as per Engineer in charge etc., complete., |
| 14 | Clean Room Doors- 7nos |
| 15 | SLIDING DOORProviding and fixing of Sliding door(MDF) of size 2500mmx2100.The shutter faces is finished with 1.0mm thick Decorative laminates as per architetural drawings on out side and 0.75 mm half white laminate on unexposed sides and edges,the shutters of each panel to hose aluminium louvers,screwed on the shutters of approved colour and shade. The rates are inclusive of frames, shutter and door fittings etc., as specified in the drawing and as directed by Engineer in charge. |
| 16 | Entrance left side sliding door |
| 17 | WET LAB TABLEProviding and fixing of Custom Built lab table 600mm width and 760mm Height of varying Length as per the site requirements. Unit to be made of 18mm thick MDF board for all vertical and horizontal members inclusive of the openable shutters except the rear vertical surface which is of 6mm thickness. All exposed MDF board surfaces to be finished in 1.0mm thk Laminate of approved colour and shade. Rear external surfaces of unit to be finished in 1.0mm thk Laminate so as the internal surfaces of the storage unit. All inside faces are to be finished with 0.8mm thk Laminate . All exposed MDF board edges to be finished with PVCedge banding. Unit to have necessary locking arrangements (efficient gadgets or equivalent) handles, hardwares, tower bolt, hinges etc. Sq.mGRANITE TOP FIXING Over MDF Surfaces – Mirror polished, 18 mm Providing and fixing 18 mm thick gang saw cut mirror polished (pre-moulded and pre polished);machine cut for kitchen platforms; vanity counters, window sills, facia sand similar locations of required size of approved shade; colour and texture laid using Suitable Tile Adhesive including moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any color and shade, upto 0.5 sqm. Job to be done as per specifications and directions of site engineer and Architectural drawings etc., complete.. Basic Cost of Granite : Rs .1800/Sqm |
| 18 | Bio Reactor room |
| 19 | Media prep. Room |
| 20 | Clean Room |
| 21 | Utility |
| 22 | FULL HEIGHT STORAGEProviding and fixing Full Height storage to detail of drawing about 1200mm wide and 2100mm high comprising. 18mm thick MDF fixed at top, rear sides and bottom at 75mm and one intermediate with necessary pvc edge banding moulding,along the edges. Minimum 5 nos of 18mm thick MDF internal shelf to be provided. Side hung shutters in 2 leaves with 18mm thick MDF and on top finished with 1mm thick laminate of approved colour and shade,including necessary grooves, box type hinges,locking arrangements,100mm long S.S brush finish handles, Tower bolt, Ball catch etc. Complete. Exposed faces of mdf at top and sides of unit,finished with 1mm laminate of approved colour and shade.All concealed faces of MDF finished with 0.8mm thick laminateas perArchitectural drawing etc., complete., |
| 23 | Over Head storageProviding and fixing LockbleOver HeadPowder coated MSStorage of 900mm x 600mm x 600mm. The Shop drawing to be submitted by Contractor for aprroval by EIC. Rate to include fabrication, fixing, hardware etc. |
| 24 | Over Head storage |
| 25 | EPOXY FLOORING THICKNESS 3MM – OVER EXISTING TILE FLOORING(i) Substrate Requirements :The Concrete or screed substrate should be a minimum of 25N/ mm2, free from laitance, dust and other contamination. The substrate should be surface dry and moisture shall be < 5%, and free from rising damp and ground water pressure. Grinding and remove all the dust foreign materials. No additional payement is payable for surface preparation. |
| 26 | (ii) Primer : Supply and apply of Epoxy primer over the prepared suraface and allow it to dry . |
| 27 | (iii)Epoxy Under lay:- Providing and applying of Apcoflor LSC 3 or equivalent , Providing and Applying 2.0mm thick over the primed substrate usingApcoflor LSC 3 or equivalent, 3 Component, satin finish, self-smoothing, Non-tainting and non-dusting, Hard-wearing, Abrasion resistant, High chemical resistance grade available .Typical uses in dry process areas subject to medium duty traffic include cleanrooms requirements ,Apcoflor LSC 3 or equivalent shall be laid at using notch tools followed by spike roll to release all entraped voids and the fully cured topping shall exhibits the typical properties as mentioned in the technical specification on the performance critiria. and complete strictly following the coverage and methodology. |
| 28 | (iv)Supply mixing and applying a Apco floor SLEpoxy or equivalent, is a self-smoothing epoxy resin floor finish applied at 1 mm thickness over the Epoxy underaly . Notch shall be used to spread the mixed Epoxy followed by the spike rolling to release the entraped air,the cured topping shall attain the following properties . complete as per the manufacturer instruction. |
| 29 | Supplying and laying Floor Marking Tape 50.8mm yellow Rate including materials,labors,transport and tools and tackles etc., complete. as perdirection engineer in charge. |
| 30 | INNER WALL ANTI FUNGAL PAINTINGSupplying and laying low VOC / Odorless Acrylic Emulsion Anti fungal Paintfor inner wall Eco friendly, Surface preparation remove lose paints,dust,oil by wire brushing/ scraping, wash with mild bleach solutions or fungicidal wash to kill fungal spores, allow to dry completely for 4 to 6 hrs. Fill cracks/ holes with cement based two coat putty, smooth-en with sandpapers, and apply onecoats primer and two coats anti-fungal paint water based,washable with matte/ silky finish, Rate including materials,labors,transport and tools and tackles etc., complete. as perdirection engineer in charge. |
| 31 | INNER WALL ANTI FUNGAL PAINTINGAREA |
| 32 | PLUMBING WORKSPARTA:SANITARY FIXTURES AND CP FITTINGS |
| 33 | SS Sink with single bowl Providing and fixing of Stainless steel sink(in weight) i/c waste pipe/bent etc. Complete with all respect. |
| 34 | CP Sink Cock:Supplying and fixing of15mm dia\"J\" type CP sink cock with swinging spout (wall mounted model) for kitchen sink with CP wall flange etc. Notes: Conditions mentioned in item no.1 shall be applicable. |
| 35 | Angle Stop Cock:Supplying and fixing of15mm dia CP angle stop cock with wall flange etc.(for aqua guard point in Kitchen) |
| 36 | PART B: UPVC PIPES AND FITTNGS (INTERNAL WATER SUPPLY): |
| 37 | Providing & fixing of UPVC schdule-40pipes confirming to ASTM standard including all UPVC fittings like tees, elbows, bends, unions, coupling, reducer tees, collars etc. The work shall include cutting jointing with solvent cement pressure testing the joints / pipeline for 10 kg/sq.cm hydraulic pressure, for 2 hourshours etc., fixed on to the wall in vertical shafts / terrace with fabricated MS brackets of suitable size with GI \"U\" clamps, bolts, nuts and GI washers includingMS brackets including making good the walls and floors.Note- Pipe may travel above false ceiling also |
| 38 | 25mm dia |
| 39 | PART – C: PVC SOIL,WASTE,VENT PIPES AND FITTINGS ( INTERNAL ) Providing, fixing,testing and commissioning of PVC soil, waste and vent pipe confirmingto IS 13592 of SWR quality( Type - B ) or 6 kg / sq.cm pressure rated including all fittings, like Bends, Tees, Elbows, Collars, junction, offsets, access pipes, jointing with solvent cement followed by application of leak proof adhesive like FRP paste & laid as ceiling hung system of inside the toilets, kitchen and utility to the required slope including necessary Clamp support & making necessary bores in wallsas applicable, making good the bores with CM 1:3 or cement concrete as applicable, curing etc., complete.-75mm dia( 6kg/sq.cm )Note- Pipe may travel above false ceiling also |
| 40 | Providing, fixing, testing and commissioning of PVC Floor Trap of self cleansing design moulded or fabricated, if not available in size mentioned below, with or without vent armjointing with rubberring/solventcementfollowedbyapplicationofleakproofadhesivelikeFRPpaste including PVC extension pipe forPVC / floor trap for with surface preparation with finishing etc., complete size: 100 mm dia x 400 mm length. Making good the floors.Note: Rate is inclusive of bore hole packing and necessary support for the floor trap. |
| 41 | 110mm dia x 75mm dia |
| 42 | Supply, installation, testing and commissioning of Submersible pump of following duty condition with features such asdry run protection, auto start/ stop, soundless, etc. Cost to include necessary fittings,starters, panel and accessories all complete as requiredDuty Condition:1.5 Cum/hr at 10m headNote: One set consists of 1 working and No standby pump |
| 43 | Supply and Fixing of dual layer PVC Loft tank (of food grade quality PVC) with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labour (including lead and lift charges), transport charges and testing complete as per specifications. (White Colour) |
| 44 | Capacity - 200 Litres (for supply) |
| 45 | Capacity - 300 Litres (For Collection) |
| 46 | ELECTRICAL |
| 47 | Wiring of light, fan, 6A sockets and exhaust fan pointsSupply and wiring for light points with 2 runs of 1.5 Sqmm FRLS, single core, multistrand copper wire ( For phase and neutral ) with one run of 1.5 Sqmm PVC insulated, single core, stranded, copper wire for earthing ( green colour ) in 20mm dia MS conduit, 16 Swg thick ( ISI marked ) with necessary accessories including supplying and fixing 6A single pole modular switch housed in manufacturers zinc passivated MS box with cover plate |
| 48 | 1 light controlled by 1 switch |
| 49 | 2 lights controlled by 1 switch |
| 50 | 3 lights controlled by one switch+external light points |
| 51 | Same item 1.1, but for 6A switched sockets including supply and fixing of switched sockets in independent locations ( Raw power ), excluding the work stations |
| 52 | Same as item no1.4, but socket and switch mounted in light control switch box |
| 53 | Supply and laying of3 R 2.5 Sqmm FRLS strandedcopper wire ( one for earth, green colour ) in 20mm diaMS conduit, 16 Swg thick ( ISI marked ) concealed in wall by chase cutting for circuit mains from LDB to switch boxes |
| 54 | Supply and laying of3 R 2.5 Sqmm FRLS strandedcopper wire ( one for earth, green colour ) in 20mm diaMS conduit, 16 Swg thick ( ISI marked ) concealed in wall by chase cutting for circuit mains from ELDB to Emergencyswitch boxes |
| 55 | Wiring for UPS sockets |
| 56 | Supply and laying of3 R 2.5 Sqmm FRLS strandedcopper wire ( one for earth, green colour ) in 20mm diaMS conduit, 16 Swg thick ( ISI marked ) concealed in wall by chase cutting and laying through partitions for UPS16A power sockets complete with all accessories ( 1 set of 16ASwitched socketsto be connected to one circuit) |
| 57 | Supply and laying of3 R 4 Sqmm FRLS strandedcopper wire ( one for earth, green colour ) in 20mm diaMS conduit, 16 Swg thick ( ISI marked ) concealed in wall by chase cutting and laying through partitions for UPSpower sockets complete with all accessories ( 1 set of 20 A switched socketsto be connected to one circuit ) |
| 58 | Supply and installation of 4 nos 6A switched sockets,modular type housed in a single manufacturers zinc passivated MS box with cover plates. The boxes to be fixed either in wall or partitions/ work stations |
| 59 | Supply and installation of 1 no 20A switched sockets,modular type housed in a single manufacturers zinc passivated MS box with cover plates. The boxes to be fixed either in wall or partitions/ work stations |
| 60 | Supply and installation of 1 no 6/16A switched sockets,modular type housed in a single manufacturers zinc passivated MS box with cover plates. The boxes to be fixed either in wall or partitions/ work stations |
| 61 | Supply and installation of 63A DP mcb control box |
| 62 | Supply and laying of2 R 10 +1R 6 Sqmm FRLS strandedcopper wire ( one for earth, green colour ) in 25mm diaMS conduit, 16 Swg thick ( ISI marked ) concealed in wall by chase cutting and laying through partitions for63A DP MCB enclosure complete with all accessories |
| 63 | Supply and laying of4 R 2.5 +2R 1.5 Sqmm FRLS strandedcopper wire ( one for earth, green colour ) in 25mm diaMS conduit, 16 Swg thick ( ISI marked ) concealed in wall by chase cutting and laying through partitions for 16A FP MCBenclosurecomplete with all accessories |
| 64 | Supply and laying of4 R 4 +2R 2.5 Sqmm FRLS strandedcopper wire ( one for earth, green colour ) in 25mm diaMS conduit, 16 Swg thick ( ISI marked ) concealed in wall by chase cutting and laying through partitions for 20A FP MCBenclosurecomplete with all accessories |
| 65 | Raw power socket wiring |
| 66 | Supply and laying of3 R 2.5 Sqmm FRLS strandedcopper wire ( one for earth, green colour ) in 20mm diaMS conduit, 16 Swg thick ( ISI marked ) concealed in wall by chase cutting and laying through partitions for Rawpower sockets complete with all accessories (1 set of 1 no 6/16A socketto be connected to one circuit ) |
| 67 | Supply and installation of 1 no 6/16A switched socket modular type housed in a single manufacturers zinc passivated MS box with cover plates. The boxes to be fixed either in wall or partitions/ work stations |
| 68 | Supply and laying of2 R 4+1R 2.5 Sqmm FRLS strandedcopper wire ( one for earth, green colour ) in 20mm diaMS conduit, 16 Swg thick ( ISI marked ) concealed in wall by chase cutting and laying through partitions for 20A DP MCBenclosure complete with all accessories |
| 69 | Supply and laying of2 R 6+1R 4 Sqmm FRLS strandedcopper wire ( one for earth, green colour ) in 25mm diaMS conduit, 16 Swg thick ( ISI marked ) concealed in wall by chase cutting and laying through partitions for 40/32A DP MCBenclosure complete with all accessories |
| 70 | Supply and laying of4 R 4 +2R 2.5 Sqmm FRLS strandedcopper wire ( one for earth, green colour ) in 25mm diaMS conduit, 16 Swg thick ( ISI marked ) concealed in wall by chase cutting and laying through partitions for 20A FP MCBenclosurecomplete with all accessories |
| 71 | Supply and installation of 63A 4P mcb 10KA, with M.S enclosure |
| 72 | Supply and installation of 40A 4P mcb 10KA,with M.S enclosure |
| 73 | Telephone / Datacables/ WIFI |
| 74 | Supply and installation of25 mm dia PVC conduit, ISI marked medium grade to be laid on wall, and partitions from main Hub to all work stations as marked in the drawing. |
| 75 | Supply and installation of20 mm dia PVC conduit, ISI marked medium grade to be laid on wall, and partitions from main Hub to all work stations as marked in the drawing. |
| 76 | Supply and installation of25 mm dia PVC conduit, ISI marked medium grade to be laid on wall, and partitions from main tel junction to all work stations as marked in the drawing. |
| 77 | Supply and installation of20 mm dia PVC conduit, ISI marked medium grade to be laid on wall, and partitions from main tel junction to all work stations as marked in the drawing. |
| 78 | Supply and installation of2-pairtelephone tinned copper cable 0.5mm dia copper conductor PVC insulatedthrough the above mentioned conduit and terminations at both ends |
| 79 | Supply and installation ofRJ-11 telephone socket mounted in manufacturers zinc passivated MS box |
| 80 | Supply and installation of2xRJ-11 telephone socket mounted in manufacturers zinc passivated MS box |
| 81 | Supply and installation of 10-pair tel krone block housed in engineering plastic box with hinged and lockable transparent cover |
| 82 | Supply and installation ofRJ-45 data socket mounted in GI anodized enclosure with cover plates |
| 83 | Supply and installation ofEe cat-6 network cable |
| 84 | Supply and installation of6 port hub switch |
| 85 | Supply and installation of6 port jack panel |
| 86 | Supply and installation ofcat -6 1mtr fly lead |
| 87 | Supply and installation ofcat -6 2mtr fly lead |
| 88 | Supply and installation of6U hub rack-Floor mounted |
| 89 | I/O Point with box |
| 90 | Supply and wifi router with two LAN output with antenna type |
| 91 | Supply of 4 port 10/100/1000 gigabit switch with 2 unink output |
| 92 | Light fittings |
| 93 | Supply , Installation including assembling, testing and commissioning of 600x600mm modular recess mounted with 36W LED (RC380 LED 34S6500L60 PSU ODS1)and suspended from ceiling either with 20mm dia 16 Swg thick MS conduit ( ISI marked ) down rods( 0.8mt long approx: ) and heavy duty ball and sockets, sealing plate, check nuts etc or with 8 Swg GI chain and giving connections |
| 94 | Supply,Installation testing and commissioningof 15W LED down lighter(DN192B LED 95-6500PSU ) to be mounted on false ceiling |
| 95 | Supply , Installation including assembling, testing and commissioning of 600x600mm modular recess mounted with 36W LEDclean room light fittingds(CR652B LED36S-6500PSU CA BO W60L60WH)and suspended from ceiling either with 20mm dia 16 Swg thick MS conduit ( ISI marked ) down rods( 0.8mt long approx: ) and heavy duty ball and sockets, sealing plate, check nuts etc or with 8 Swg GI chain and giving connections |
| 96 | M.S Fabrication metrials |
| 97 | Supply and Erection of MS metrials of cable tray supports,panel,etc |
| 98 | Distribution Boards |
| 99 | LDB-1, and ELDB-1 Supply and installation of double door IP:434-way TPN MCB 7 segment type DB with following. The same shall be concealed to the wall1 no mainincomer feeder fitted with 40 A 4-pole MCB,10ka3 nos incomer feeder fitted with 40 A 2-pole RCBO with 30ma sensitivity for phase incomer12 nos of 6 /16/20 A ,10kASP MCBs as outgoing feeders ( 4 nos per phase) |
| 100 | PDB-1 Supply and installation of double door IP:436-way TPN VDB MCB/MCCBtype DB with following. The same shall be concealed to the wall1 no mainincomer feeder fitted with 63 A4-pole MCCB,25 Ka1 nos O/G feeder fitted with 2 nos 20A TP,2 nos 32A SP ,2 nos 40A SP,3 nos 20 A SP ,5 nos 16A SP MCB\"Sas outgoing feedrs |
| 101 | UPS DB-1Supply and installation of double door IP:4312-way TPN VDB MCB/MCCBtype DB with following. The same shall be concealed to the wall1 no mainincomer feeder fitted with 125 A 4-pole MCCB,25 Ka8 nos O/G feeder fitted with 20/16 A TP-pole MCB,1 no 63 A 11 nos 16A SP MCBs as outgoing feedrs |
| 102 | PDB-2Supply and installation of double door IP:436-way TPN MCB 7 segment type DB with following. The same shall be concealed to the wall1 no mainincomer feeder fitted with 63 A 4-pole MCB,10 Ka3 nos incomer feeder fitted with 63 A 2-pole RCBO with 100mA sensitivity for phase incomer18 nos of 16 A ( 6 nos per phase ) SP MCBs as outgoing feedrs |
| 103 | Supply and installation of 63A FP RCBO, 100 MA with M.Senclosure for A/C control |
| 104 | Supply and installation of 63A DP MCB, 10 KA with M.Senclosure |
| 105 | Supply and installation of 40/32A DP MCB,10 KA with M.Senclosure |
| 106 | Supply and installation of20A FP MCB 10 ka with M.Senclosure |
| 107 | Supply and installation of16A FP MCB 10 ka with M.Senclosure |
| 108 | Supply and installation of 20A FP MCB, 10 KA with M.Senclosure |
| 109 | Supply and installation of 160A TPN MCCB,25 KA with M.Senclosure for UPS unit control |
| 110 | Supply and installation of 20A DP MCB, 10 KA and 20A Metal cload socketwith M.Senclosure |
| 111 | Switch boards |
| 112 | MSBSupply, erection, testing and commissioing of cubicle type switch board Floor mounted, fabricted with 16 Swg CRCA sheets with the following Bus bar chamber consisting of 250A electrolytic quality AL busbars supported on SMC for phases and 200A for neutral. The busbars shall have colour coded PVC sleeving.The fault level shall be 36 Ka for 1 second.Metering cubicle consisting of 1 no microprocessor controlled meter for reading all the electrical parameters like voltage, current, Kw,etc ( Socomec EM-VIFP ), LED type RYB indication lamps, 3 nos of resin cast CTs of ratio 250/5A class-1, 15 Va1 no incomer feeder fitted with 1 no 250 A TP+N MCCB, 36ka 1no 160A TP+NMCCB, 25 KA, 6 no 63 ATP+NMCCB25 ka as outgoing feedersPanel will have a ring main earthbus with copper strip of size 25x3mm. All the switch frames and cubicles shall be connected to this earth which will be finally interconnected to external earth grid. .The panel shall be powder coated to siemens grey shade. .All internal wiring shall be carried out with adequate size copper wires.A detachable gland plate shall be fixed on the top of the cable alley for cable terminations. All MCCBs shall be fitted with front operating handle with door interlock |
| 113 | UPS MAIN PANEL-1 |
| 114 | Supply, erection, testing and commissioing of cubicle type switch board Floor mounted, fabricted with 16 Swg CRCA sheets with the following Bus bar chamber consisting of 160A electrolytic quality AL busbars supported on SMC for phases and 100A for neutral. The busbars shall have colour coded PVC sleeving.The fault level shall be 25 Ka for 1 second.Metering cubicle consisting of 1 no microprocessor controlled meter for reading all the electrical parameters like voltage, current, Kw,etc ( Socomec EM-VIFP ), LED type RYB indication lamps, 3 nos of resin cast CTs of ratio 160/5A class-1, 15 Va1 no incomer feeder fitted with 1 no 160 A TP+N MCCB, 25 ka 1nos 125 A ,3 nos 63 ATP+NMCCB25 ka as outgoing feedersPanel will have a ring main earthbus with copper strip of size 25x3mm. All the switch frames and cubicles shall be connected to this earth which will be finally interconnected to external earth grid. .The panel shall be powder coated to siemens grey shade. .All internal wiring shall be carried out with adequate size copper wires.A detachable gland plate shall be fixed on the top of the cable alley for cable terminations. All MCCBs shall be fitted with front operating handle with door interlock |
| 115 | UPS Main wiring |
| 116 | Supply, installation, testing and commissioining of 4R 70 Sqmm FRLS multistrandedcopper wire in 4R 50MM dia 16 swg thick MSconduit ( ISI marked ) from ups , toups interlocking panel |
| 117 | Supply, installation, testing and commissioining of 4R 10 Sqmm FRLS multistrandedcopper wire in 32mm dia 16 swg thick MSconduit ( ISI marked ) from ups , toups interlocking panel |
| 118 | UG cable |
| 119 | Supply and laying of3.5x 150 Sqmm AL AR XLPE cable to be clamped on wall with GI clamps/ laid in excavated trenches etc (Main cable for MSB and ups panel -2 ) |
| 120 | Same as item no 10.1, but 3.5x70 Sqmm AL AR XLPE cable |
| 121 | Same as item no 10.1, but 3.5x50 Sqmm AL AR XLPE cable |
| 122 | Same as item no 10.1, but 4x10 Sqmm CU AR XLPE cable along with 2R 10 SWG copper wire |
| 123 | Same as item no 10.1, but 4x6 Sqmm CU AR XLPE cable along with 2R 10 SWG copper wire |
| 124 | Terminations of following cable with SIBG glands and copper crimping sockets and earthing of glands with copper clip and connecting the same to earth grid with 14 Swg copper wire |
| 125 | 3.5x150 Sqmm |
| 126 | 3.5x70 Sqmm |
| 127 | 3.5x50 Sqmm |
| 128 | 4x10 Sqmm |
| 129 | 4x6 Sqmm |
| 130 | Earthing |
| 131 | Supply, installation, testing and commissioing of CUpipe electrode 40mm dia 3 Mt long, 3MM Thickas per IS-3043 complete with all accessories like watering funnel, clamps etc.The same to be installed in a pit 3 Mt deep and filled with alternate layers of charcoal, salt mixed with river sand. A brick work masonary shall be constructed of size 450x450x150mm and cement plasted at both inside and outside walls. A 3mm thick cast iron plate with frame work shall be placed over the chamber ( 2 nos for ups earthing and2 nos for m/c body) |
| 132 | Supply and installation of 25x3 mm copper strip to interconnect theearth pits with SSB and other equipments |
| 133 | Supply and installation of 10 Sqmm multi strand copper wire FRLS insulated to be drawn in 25mm dia PVC conduit 2mm thick and to be clamped partially on wall with GI clamps and partially burried in ground and terminations at both ends with copper crimping sockets ( For lab earthing ) |
| 134 | Public address system wiring |
| 135 | Supply and installation of 2 core 24/0.2mm dia twin twisted copper conductor PVC insulated cable drawn in 20mm dia medium grade PVC conduit ( ISI marked ) including clamping the same with GI clamps on ceiling, wall, through partitions etc and chase cutting of wall wherever required |
| 136 | Supply and installation of 6W ceiling mounted ring speaker in plastic mould with built in transformer |
| 137 | Supply and installation of volume control housed in GI box |
| 138 | CCTVCables & Camera |
| 139 | Supply and installation of25 mm dia PVC conduit, ISI marked medium grade to be laid on wall, and partitions |
| 140 | Supply and installation of20 mm dia PVC conduit, ISI marked medium grade to be laid on wall, and partitions |
| 141 | Supply and installation of 16 channel DVR TURBO(Hikvision) |
| 142 | Supply and installation of 2 MP Camera Bult TURBO (Hikvision) |
| 143 | Supply and installation of 2 MP Dome TURBO (Hikvision) |
| 144 | Supply and installation of 8 channel Adapter |
| 145 | Supply and installation of 1 TB Hard disk (seagate/wd) |
| 146 | Supply and installation of 1+3 CCTV cable |
| 147 | Supply and installation of 2U Rack |
| 148 | Supply and installation of BNC Enclosure (pvc box) & INC |
| 149 | Supply and installation of 24\" Monitor |
| 150 | Supply and installation of 32\" TV |
| 151 | Cable tray GI perforated tray-jindal / tata. (all accessories is your scope) |
| 152 | Supply, installation, testing and commissioing ofGI perforated tray width-450mm hight-50mm |
| 153 | Supply, installation, testing and commissioing ofGI perforated tray width-300mm hight-50mm |
| 154 | Supply, installation, testing and commissioing ofGI perforated tray width-100mm hight-50mm |
| 155 | HVAC |
| 156 | Supply, Installation, Testing and Commissioning of ceiling suspended AHU as under:Modular AHU panels with GI sheet of 0.60 mm thick for both inner & outer casing with 25 mm insulation sand witched in between. The outer panel shall have pre coating for corrosion resistance as also toprovide a very good finish. Blower section with forward curvedcentrifugal fan with TEFC motor (IP 55 and Class F insulation). Drain section with 1.2mm SS drain pan.Coil section with6 row chilled water coil, Slimseal BF valves at inlet/ outlet, drain and purge connections.a. Flexible connection the outlet.b. AHU sub panel with isolator and starter (Star/ Delta) with lockable OFF pushbutton. c. Fresh air cowl with screen and damper.d. Inlet and outlet isolating valves of 50 mm dia:e. Pressure gauges and thermometers at inlet and outletf. All standard accessories, supports etc.,g. 2 way chilled water flow control valve with sensor and control wiringh. Btu meter for energy consumed measurementALL THE ABOVE WITH CAPACITY AS UNDER:CAPACITY 12.5 TR, 50 mm SP, 5000 CFM |
| 157 | CAPACITY 10 TR, 40 mm SP, 4000 CFM |
| 158 | Supply, Laying, Pressure testing and insulating of chilled water piping, complete with fittings, supports and insulation. Insulation of 50 mm thick TF quality thermocole with 22 G Aluminium cladding. Insulations shall be as under/as per IS 1239, Mild Steel heavy (Class C) class pipe: |
| 159 | a) 100 mm dia: |
| 160 | b) 80 mm dia: |
| 161 | c )65 mm dia: |
| 162 | d) 50 mm dia: |
| 163 | e) Isolating butterfly valve at tapping point - 80 mm size |
| 164 | Drain piping from the AHU with PVC piping and insulated as required: |
| 165 | 50 mm dia: |
| 166 | 32 mm dia: |
| 167 | 25 mm dia: |
| 168 | 25 mm dia drain valve: |
| 169 | 50 mm dia drain valve: |
| 170 | Supply and laying of galvanized sheet steel ducting with class VIII quality of zinc coating, complete with anchor fasteners and MS supports, angle bracings as required, nut, bolt & gasket etc |
| 171 | a) 24 G ducting: |
| 172 | b) 22 G ducting: |
| 173 | c) 20 G ducting |
| 174 | Supply and fixing of volume control dampers |
| 175 | 20G |
| 176 | 22G |
| 177 | Supply and installation of powder coated Al. Supply air grills and return air outlets: |
| 178 | a. Supply air diffuser with damper |
| 179 | b. Return air grille w/o damper. |
| 180 | Fan filter unitfor labs comprising as standard feature with HEPA filter efficiency not less than 99.97% at 0.3 Microns (Factory tested) with supply air inlet collar, preferable size 600x600 but not exceeding 1200x600, mounted on the false ceiling, with capacities as under: |
| 181 | Capacity 750 Cubic feet per minute |
| 182 | Capacity 500 Cubic feet per minute |
| 183 | Supply and installation of fusible link type fire damper |
| 184 | Supply and laying of thermal insulation of ducting with 15 mm thick nitrile rubber, laminated with Aluminium foil |
| 185 | Supplying and installation of acoustic insulation of ducting with 19 mm thick armasound or equivalent material. |
| 186 | Removal and reinstallation of a 8 TR unit adjacent to the present lab, complete with new items as under:a. Flexible connection the outlet.b. AHU sub panel with isolator and starter (Star/ Delta) with lockable OFF pushbutton. c. Fresh air cowl with screen and damper.d. Inlet and outlet isolating valves of 50 mm dia:e. Pressure gauges and thermometers at inlet and outletf. All standard accessories, supports etc.,g. 2 way chilled water flow control valve with sensor and control wiring |
| 187 | h. Btu meter for energy consumed measurement |
| 188 | FIRE FIGHTING & FIRE ALARM SYSTEM |
| 189 | Supply, Installation, Testing and Commissioning (SITC) of a Standalone micro processor based addressable type fire alarm panel, of 2 loops, complete with battery back up for 8 hours of operation of the panel with 30% of the detectors in operation. |
| 190 | SITC of Multicriteria smoke cum heat detectors below the false ceiling |
| 191 | SITC of Multicriteria smoke cum heat detectors above the false ceiling |
| 192 | SITC of manual call point near exits |
| 193 | SITC of dual tone electronic hooter |
| 194 | SITC of response indicators |
| 195 | SITC of Heat Detector for electrical and communication rooms |
| 196 | Supplying and laying of interconnecting copper cabling of 2 x 1.5 sqmm FRLS cable |
| 197 | Other accessories like end of line resistance etc as required |
| 198 | Providing Air conditioning trip module within the panel as required |
| 199 | Portable Fire Extinguishers as under: |
| 200 | 5 Kg CO 2 Extinguishers |
| 201 | 5 Kg Dry Powder Extinguishers |
| 202 | Extension of sprinkler piping with M S heavy piping complete with supports, fittings and painting as under: |
| 203 | 50 mm pipe |
| 204 | Sprinkler heads |
| 205 | Flexible hose from the pipe header about 2 M long |
| 206 | 50MM isolating valve, BF type |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy