| 1 | Repair, maint and making the continuity of supply after rectifying the defects of the ceiling fan, exhaust fan, wall fan, desert cooler, geyser, water cooler, refrigrator, ACs etc. including providing of small pieces of electrical wire of size 0.75 to 4 Sqmm twin/three core and length not exceding 1 mtrs and all types of screws, nuts, bolts & washers as required at site complete all as specified and directed. (Note :- (i) Any accessories found unserviceable that shall be replaced & paid under respective items of this Sch. (ii) The site of attending complaints are all Married/OTM Accn in Cantt area , Contractor Shall Provide Minimum Two Tradesmen Having minimum ITI/3 year experience for work with Suaitable Toolbag to attend the complaints in all working days. (iii) Contractor/ superviser of contractor will collect complaint slip on daily morning from MES complaint cell and deposit the same after rectify on next day morning. (iv) Contractor shall ensure the security passes for his staff to be obtained from concern authority for attending complaints. (v) The contractor will ensure that the electricians with necessary tools bag shall always remain present at complaint cell to attend the complaints. (vi) A recovery of Rs 500/- for not attending the complaints upto 04 hours& Rs 1000/- shall be recovered from the contractor after 24 hrs. (vii) Complaint slip book, registers & Other Connected Dacuments wiil be provided by contractor without any extra cost. |
| 2 | Disconnecting electrically, taking down existing ceiling Fanany type and capacity with due care, dismantling bladesfor repairing with all accessories complete all as specified and directed. |
| 3 | Assembling the ceiling fan any type with blades at site and hanging on ceiling /wall refixing after getting rapaired with all accessories complete all as specified and directed. |
| 4 | Strip opening of AC ceiling fan 230 volts any make /type/size for carrying out repair/greasing / oiling, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing complete all as specified and directed. Note :- 1. Repairs will be measured and paid separately under respective items. |
| 5 | Rewinding of AC ceiling fan motor 1200/1400 mmsweep any make/size with super enamelled copper winding wire with gauge including cutting of old burnt winding. Sleeve work varnishing with `B\" class insulation varnish, greasing, connection with flexible wire of appropriate size two core copper wire upto connector block complete all as specified and directed. |
| 6 | S&F fan capacitor AC 440 volts 4 mfd 50HZ complete all as specified and directed. |
| 7 | All as per item No 6.00 above but 2.5 mfd complete all as specified and directed. |
| 8 | M&L for repairs, alignment grinding to shaft, remetalling & finishing complete all as specified and directed. |
| 9 | S&F ceiling fan shaft of standard size including taking out old shaft complete all as specified and directed. |
| 10 | Supply and fixing in replacement fan regulator electronic, step type hum free suitable to control speed of fan from 0 to 100% and connecting electrically complete all as specified and directed. |
| 11 | Disconnecting electrically, taking down existing exhaust Fanany type and capacity with due care, dismantling bladesfor repairingwith all accessories complete all as specified and directed. |
| 12 | Assembling the exhaust fan any type with blades at site and hanging on ceiling /wall refixing after getting rapaired complete with all accessories complete all as specified and directed. |
| 13 | Strip opening of exhaust fanany size / make / sweep for carry out repair/greasing, oiling work, re-assembling, replacing rubber reel, fixing clamp, bolts and nuts with lock pins and testing after carrying out the repair, complete all as specified and directed. |
| 14 | Rewinding of exhaust fanmotor any size, from 225 to 450 mm sweep with supper enamelled copper wire as required including necessary cutting of old burnt winding wire, cleaning of slots, greasing and provision of necessary threading/sleeve work and taking out connection in lead with PVC copper wire of appropriate size upto connector block complete all as specified and directed. |
| 15 | M&L in replacement of ball bearing any No suitable forceiling fan upto 1400mm sweep complete all as specified and directed. |
| 16 | Replacement of ball bearing for exhaust fan upto 450mm sweep complete all as specified and directed. |
| 17 | Cleaning thoroughly ceiling fans 48\"/56\" (1200mm / 1400mm) sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified and directed. |
| 18 | Cleaning thoroughly exhaust fan 225 mm to 450 mm sweep with Kerosene Oil and spray painting with spray gun including preparation of surfaces, and writing MES No after painting at site complete all as specified and directed. |
| 19 | S&F in replacement of fan blade set plastic suitable for exhaust fan 225 to 450 mm sweep complete all as specified and directed. |
| 20 | S&F in replacement of fan blade set steel 1200/1400mm sweep suitable for ceiling fan all as required at site complete all as specified and directed. |
| 21 | S&F in replacement ofdown rod for ceiling fans made out of 15 mm diaMS pipe, medium grade duly threaded/pin complete all as specified and directed. |
| 22 | All as per item No 21 above but of size 1 Mtrs long complete all as specified and directed. |
| 23 | All as per item No 21 above but of size 1.5 Mtrs long complete all as specified and directed. |
| 24 | All as per item No 21 above but of size 2 Mtrs long complete all as specified and directed. |
| 25 | All as per item No 21 above but of size 3 Mtrs long complete all as specified and directed. |
| 26 | All as per item No 21 above but of size 4 Mtrs long complete all as specified and directed. |
| 27 | Supply and fixing lower and upper canopy of fans of ceiling fans of suitable size required at site complete all as specified and directed. |
| 28 | Supply and fix exhaust fan made of sturdy Engineering plastic with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200mm complete all as specified and directed. |
| 29 | Supply and fix exhaust fan made of sturdy Engineering plastic with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and directed. |
| 30 | M&L for 40 mm bore galvanised iron tubing medium grade fixed to walls or hanging the fan including making hole and making good the disturbed surface by filling with PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate, plastered the surface and match the periodical such as oil bound distemper, white/colour wash etc with exisiting one complete all as specified and directed. |
| 31 | All as per item No 30 but of GI pipe of size 50mm bore complete all as specified and directed. |
| 32 | M&L for providing PVC rounded 3 core 0.75 sqmm copper cable and making necessary connection complete all as specified & directed. |
| 33 | All as per item No 32 above but copper cable of size 1.5 Sqmm complete all as specified and directed. |
| 34 | All as per item No 32 above but copper cable of size 2.5 Sqmm complete all as specified and directed. |
| 35 | M&L for taking down/out desert cooler from existing place and removing old paint from the body of desert cooler and applying painting on desert cooler external body, fan and pump with a coat of synthetic enamel grey paint , internal body with a coat of synthetic enamel black paint with brush painting at site after proper dusting cleaning and scraping old painted surface and refixing on same/other location after painting complete all as specified and directed. |
| 36 | M&L in replacement of side panels of desert cooler made out of 22 SWG mild steel sheet of size not more than 0.70x0.80 mtr to match with existing cooler with jalli, wood wool pad, fastners painting with two coat of synthetic enamel paint over and including a coat of primer etc complete all as specified and directed. |
| 37 | M&L in replacement of desert cooler water tank made out of 19 SWG mild steel sheet of size not more than 0.80x0.80x0.20 mtr (approx)to match with existing cooler including front side panel opening with louvers, provision for selector switch, indicator lamp etc and top cover plate made of 22 SWG mild steel along with vertical angle support of suitable height and two coat of synthetic enamel paint over and including a coat of primer etc complete all as specified and directed. |
| 38 | Supply and fixing in replacement of water lifting pump submersible type 220 -240 Volts 50 HZ as per sample complete all as specified and directed. |
| 39 | Supply & fixing in replacement of kit fan motor of desert cooler 230 volts with blades, fixing legs, nuts, bolts, washers etc of complete all as specified & directed. |
| 40 | S&F in replacement of ready made wood wool pad size as required at site of 15 mm thickness, made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as specified & directed. |
| 41 | M&L for disconnecting, dismantling, refixing and rewinding of kit fan motor upto450 mm sweep of desert coolers 230 volts AC 50 C/S with super enamelled copper conductor wire of existing gauge as original including replacement of bush -02 Nos shaft -01 No ring-01 No & clamp-04 Nos complete all as specified & directed. |
| 42 | S&F of desert cooler stand using angle iron (40 x 40 x 6 mm) making square type platform of min size 800 x 800mm and fixing through two angle iron piece for horizontal support and two angle iron piece for 45 degree angle vertical support into the walls of any type / height as required on site by means of required nuts, bolts, fastners, welding work etc to form a platform suitable for fixing the desert cooler of any size & type compete all as specified and directed.Note: Angle iron should be painted with a coat of red oxide primer and two coat of synthetic enamel paint.Minimum 20 cm length of the angle iron should be inserted into the wall and fixing the same through required PCC work.Cutting chases in walls required for fixing the angle iron support shall be finished with cement mortar 1:4 and surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor. |
| 43 | Supply and fix desert cooler electric driven (single phase), having nominal air flow capacity of 4000 CuM per hour (or nearest size).Plastic/PVC Body complete all as specified and directed. |
| 44 | M&L for dismantling, taking out old u/s clamp and fixing with new clamp for kit fan motor of desert cooler as per site requirement with nuts & washers complete all as specified and directed. |
| 45 | Disconnecting, dismantling old u/s selector switch and fixing with new selector switch complete all as specified and directed. |
| 46 | Disconnecting, dismantling old u/s indicator lamps and replaced with new complete all as specified and directed. |
| 47 | Dismantling old PVC Water distributor four way and refixing with new complete all as specified and directed. |
| 48 | S&F in replacement of existing UNSV desert cooler blade and fix in the desert cooler and complete all as specified and directed. |
| 49 | Disconnecting, dismantling and taking out old u/s storage type water heater geyser of cap 25/35 Ltrs from wall for repair at site complete all as specified and directed. |
| 50 | Fixing only storage type water heater geyser on wall after reapir and replacement of old unserviceable with gutties/anchor bolts/ or nuts & bolts and fixing the same in existing /other location complete all as specified and directed. |
| 51 | M&L for spray painting of outside surfaces of geyser with two coats of white synthetic enamel paint after preparing surface with and including writing MES No. complete all as specified and directed. |
| 52 | M&L for opening the geyser and replacement of glass wool for insulation of geyser of 25 to 50 ltrs capacity of anymake / type complete all as specified and directed. |
| 53 | S&F in replacement of PVC flexible connection of length 600 mm with two brass adopter as per existing sample suitable for carrying hot / cold water, fixed one end at geyser inlet and other to outlet water supply point complete all as specified and directed. |
| 54 | M&L for disconnecting, dismantling old u/s thermostat switch of geyser 25 to 50 ltrs capacity and replaced with new with temperature range adjustable from 25 to 90 degree centigrade, superior quality 20 Amps rating, 220 Volts AC supply complete all as specified and directed. |
| 55 | M&L for disconnecting, dismantling old u/s heating element of cap 2 KW and replaced with new and testing on completion complete all as specified and directed. |
| 56 | All as per item No 55 above but heating element of capacity 1.5 KW complete all as specified and directed. |
| 57 | M&L for dismantling old u/s syphon assembly of geyser 25 to 50 ltrs ltr capacity and replaced with new stainless steel syphon complete all as specified and directed. |
| 58 | M&L for dismantling old u/s inner tank of geyser and replaced with new stainless steel inner tank suitable for 25 to 50 ltrs ltrs capacity geysers of 22 SWG and hydraulically tested at 22.5 PSI pressure maintained at 90 degree centigrade as approved complete all as specified and directed. |
| 59 | M&Lin replacement of modular single pole and neutral enclousere with a top pin, earth plug and socket copmlete with one SP MCB 20 Amps, 240 Volts with rupturing capacity 10 KA \"C\" curve complete all as specified and directed. |
| 60 | S&F in replacement of pressure release valve with inlet coupling of superior quality as approved complete all as specified and directed. |
| 61 | S&F in replacement of plug top 5 Amps complete all as specified and directed. |
| 62 | S&F in replacement of plug top 15 Amps complete all as specified and directed. |
| 63 | Dismantling and taking down oldunserviceable Geyser and depsited in MESStore yard & Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece complete all as specified and directed. |
| 64 | S&F in replacement of indicator LED bulb square / round type complete with necessary connection wire of red & green colour complete all as specified and directed. |
| 65 | S&F of ceiling fan clamps for fixing with fan rod including nut, bolt, lock pin, rubber real complete all as specified and directed. |
| 66 | S&F D hook for hanging of ceiling fan on ceiling of suitable shape of mild steel flat iron with suitable size nuts, bolts & washers complete all as specified & directed. |
| 67 | Dismantling and taking down oldunserviceable Fan and depsited in MESStore yard & Supply, fixing and testing ceiling fan, white colour Energy saver 1200mm sweep (not exceeding40 watt),230 volts single phase complete Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) alongwith Remote and down rod, adequate size of clamp, making electric connection with PVC rounded 3 core 1 sqmm copper cable from ceiling rose to ceiling fan connector, including writing MES No. in black synthetic enamel paint / engraving with tool complete all as specified and directed. |
| 68 | Disconnecting electrically, taking down, dismantling, opening the cover of AC/Split and taking out and servicing of window/Split type air conditioner cap 1.5/ 2 Ton capacity including cleaning / removing all dust / mud, oiland other foreign particle from grill, filter, condenser fin, evaporator fin including opening cover, peripheries and whole body using detergent solution or chemical solution and refitting all parts and fixing the same in existing/other location complete allas specified and directed. |
| 69 | Disconnecting, dismantling, opening the cover of AC and removing unserviceable / defective parts from the window / Split AC of 1.5 / 2 Ton capacity including necessary welding with existing refrigerant pipe, supply & charging refrigerant gas and testing complete all as specified and directed.Note: (i) All spares such as sealed compressor, fan motor, relay, capacitor, over load relay shall be measured and paid separately if required under respective item of Schedule ‘A’ as supply only and quoted cost for fixing of the same shall be deemed to included in quoted rate in the item.(ii)If any item required to make equipment functional like capillary copper pipe etc is deemed to be included in unit quoted rate.(iii)Old unserviceable hermetic sealed unit and other materials obtained from the window type AC will be accounted under Schedule of credit and same shall become the property of the Contractor. |
| 70 | Supply only cooling coil of window type AC any cap up to 2 ton complete all as specified and directed. |
| 71 | Supply only front grill of window AC suitable for 1.5/2 ton cap complete all as specified and directed. |
| 72 | Supply only rotary type sealed compressor of window AC 1.5/2 Ton cap complete all as specified and directed. |
| 73 | Supply only Air blower motor as per sample suitable for window/split type AC of 1.5/2 Ton capacity single phase complete all as specified and directed. |
| 74 | Supply only starting capacitor suitable for window/split AC of rating 45 - 100 Mfd complete all as specified and directed. |
| 75 | Supply only starting relay suitable for Window/split AC of capacity 1.5 / 2.0 Ton complete all as specified and directed. |
| 76 | Supply only Cooling thermostat switch as per sample for window/split type AC of 1.5 /2.0 Ton capacity complete all as specified and directed. |
| 77 | Supply only condenser fan blade suitable for window/split type AC of any make & capacity complete all as specified and directed. |
| 78 | M&L for minor denting work to window / Split type air conditioners of 1.5 / 2 Ton capacity including applying spray painting with a coat of synthetic enamel paint of required shade complete all as specified and directed. |
| 79 | S&F in replacement of Inlet / outlet control valve for outdoor / indoor unit of suitable size, of any make & any type complete all as specified and directed. |
| 80 | Supply and fixing in replacement of defective remote control hand set with \"AAA\" batteries for window/split type AC\"s, of any model / make complete all as specified and directed. |
| 81 | Supply and fixing in replacement of display indication on LCD screen assembly mounted on indoor unit (cooling unit) for split type AC’s, of any model / make complete all as specified and directed. |
| 82 | Supply and fixing of micron filter suitable for window / split type AC of 1.5 Ton capacity complete all as specified and directed. |
| 83 | Supply and fixing ofcopper tube as per existing and site requirement complete all as specified and directed. |
| 84 | Disconnecting, dismantling and taking out indoor and outdoor unit of split type AC & window AC with cooling tubing and other accessories with carefully and deposited to MES store yard complete with outer/inner unit, copper tubing, drain pipe and remote complete all as specified and directed. |
| 85 | supply and fixing in replacementof deoxidized annealed copper tube including brazing etc. complete all as specified and directed. |
| 86 | supply and fixing in replacement offoamed polythene insulating pipe of 18 mm internal dia and 8 mm wall thickness complete all as specified and directed. |
| 87 | supply and fixing in replacement offoamed polythene insulating pipe of 8 mm internal dia and 7 mm wall thickness complete all as specified and directed. |
| 88 | M&L in repair of Main control circuit (PCB) for window/split type AC\"s, ofInverter/Normal AC\"s any model / make complete all as specified and directed. |
| 89 | S&F in replacement of Main control circuit (PCB) for window/split type AC\"s, ofInverter/Normal AC\"s any model / make complete all as specified and directed. |
| 90 | S&F in replacement ofPVC flexible drain pipe 15mm to 25mm dia complete all as specified and directed. |
| 91 | M&L for flushing, pressurising the system, leakage testing, vacuumization and charging with refrigerant R -22 / R-134a/R-410 (suitable as per requirement) after rectifying leakage in the system vaccumising and dehydration as per standard practice including testing in all respect for window / split type air conditioner 1.5 / 2.0 TR cap at site / contractor\"s workshop including any welding / repair work reqd at site complete all as specified and directed. |
| 92 | Supply and charging refrigerant R-22/R134a/R410 as per type of ACs for any type of gas filling the AC/Refrigeritor/water cooler/deep freezer etc complete one time for topping up or making full qty including plugging the leakage/ welding / repair work reqd at site complete all as specified and directed. |
| 93 | Supply and install hi wall split units indoor with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 Ton complete all as specified and directed. |
| 94 | Supply and install hi wall split units Outdoor complete with all accessorises i.e. in built Rotary Compressor, Condenser & Cooling fan, Single phase 230 volts with minimum 3 star rating and EER 3.2 of capacity 1.5 Ton complete all as specified and directed. |
| 95 | Disconnecting, dismantling old u/s compressor from refrigrator and replaced with new for the refrigerator of capacity 165 to 310 Ltrs including necessary welding with existing refrigerant pipe, supply & charging refrigerant gas including testing complete all as specified and directed. |
| 96 | Supply and fixing in replacement of Starting relay suitable for refrigerator of any make and capacity complete all as specified and directed. |
| 97 | Supply and fixing in replacement of cooling Thermostat suitable for refrigerator of any make and capacity complete all as specified and directed. |
| 98 | Supply and fixing in replacement ofPVC freezer door suitable for any size and capacity of the refrigerator complete all as specified and directed. |
| 99 | Supply and fixing in replacement of Magnetic rubber door gasket suitable for any size and capacity of the refrigerator complete all as specified and directed. |
| 100 | Supply and fixing in replacement of Copper liquid line filter two way / one way of refrigrator any type/capacity complete all as specified and directed. |
| 101 | Supply and fixing in replacement ofOver load protector of size 1/6 HP to 1/8 HP of refrigrator any type as per site requirement complete all as specified and directed. |
| 102 | Supply and fixing in replacement ofCapillary tube as per site requirement of refrigrator/water cooler any type complete all as specified and directed. |
| 103 | Supply and fixing in replacement of Bulb of refrigrator any type as per site requirement of complete all as specified and directed. |
| 104 | Supply and fixing in replacement ofIce tray twist type PVC of refrigrator any type complete all as specified and directed. |
| 105 | Supply and fixing in replacement of Condenser cooling coil suitable for refrigerator capacity min 165 ltr to maximum 310 ltrs complete all as specified and directed. |
| 106 | Supply and fixing in replacement of Vegetable basket suitable for refrigerator as per site requirement complete all as specified and directed. |
| 107 | Supply and fixing in replacement ofPartition jalli /glass shelf suitable for refrigerator as per site requirement complete all as specified and directed. |
| 108 | Disconnecting, dismantling and taking out old u/s voltage stabilizer of cap 1 to 5 KVA and refixing the same in same/other location after repair incl all minor parts i.e wire, nut, bolt and washers etc complete all as specified and directed. Note : Spare parts will be measured and paid seperately under respective items as supply only and cost for fixing of the same shall be deemed to included in quoted rate under this item. |
| 109 | Supply only ofMain relay of voltage stabilizer 1 to 5 KVA complete all as specified and directed. |
| 110 | Supply only ofMain control circuit (PCB) of voltage stabilizer 1 to 5 KVA complete all as specified and directed. |
| 111 | Supply only ofreplacement of sensor transformer of voltage stabilizer 1 to 5 KVA complete all as specified and directed. |
| 112 | Supply only of voltmeter of voltage stabilizer 1 to 5 KVA complete all as specified and directed. |
| 113 | Supply only of Time delay relay, 2-3 minute over / low voltage 180 Volts AC and high voltage 260 Volts AC of voltage stabilizer 1 to 5 KVA complete all as specified and directed. |
| 114 | Taking out old burnt winding of transformer and re-winding the same with super enameled copper winding wire (existing size) for 1 to 5 KVA voltage stabilizers including all necessary insulating material and testing complete all as specified and directed. |
| 115 | M&L for painting of voltage stabilizers with a coat of synthetic enamel paint of existing shade after proper cleaning and scraping out old painted surfaces and writing GE (I) Kanpur on voltage stabilizers in block letters with white synthetic enameled paint complete all as specified and directed. |
| 116 | Supply and fixing in replacement of Automatic voltage stabilizer used up to 1.5 ton AC working range-170 V To 270 Vsingle booster complete all as specified and directed. |
| 117 | Taking out water cooler of any make and type of capacity 40 / 80 / 150 ltrs from position and cleaning/serviceing the condenser coil and storage tank with chemical base solution and soda water including servicing, oiling of air blower motor, checking of electrical & water supply connection incl and re-fixing the same on its existing position after testing complete all as specified and directed. |
| 118 | Disconnecting, dismantling and taking out defective water cooler of any make and type of capacity 40 / 80 / 150 ltrsfor repair complete all as specified and directed. |
| 119 | M&L for fixing/installation of water cooler any type of cap 40/ 80/ 150 ltrs and making all electrical/water connection and testing complete all as specified and directed. |
| 120 | S&F in replacement ofsealed compressor suitable for water cooler of capacity up to 40 / 80/ 150 Ltrsas per sample complete all as specified and directed. |
| 121 | S&F in replacement of Starting capacitor 40-60 Mfd / 60-80 Mfd / 80-100 Mfd for water cooler complete all as specified and directed. |
| 122 | S&F in replacement of Running capacitor 10-30 Mfd for water coller/ window ac/ split ac/refrigerator complete all as specified and directed. |
| 123 | S&F in replacement of Thermostat suitable for water cooler of capacity 40 / 80 / 150 ltrs complete all as specified and directed. |
| 124 | S&F in replacement ofStarting relay of water cooler compressor requirement complete all as specified and directed. |
| 125 | S&F in replacement of Blower motor of water cooler with fan blade of capacity 1/10 to 1/35 HP as per site requirement complete all as specified and directed. |
| 126 | S&F in replacement ofOver load protector of water cooler suitable for water coolers complete all as specified and directed. |
| 127 | S&F in replacement of PVC flexible pipe transparent 15 / 20 mm dia for water cooler complete all as specified and directed. |
| 128 | S&F in replacement ofPush tap long body, cast copper alloy, chromium plated suitable for water cooler of capacity up to 150 ltrs complete all as specified and directed. |
| 129 | S&F in replacement of PVC float valve 15 / 20 mm dia with rod & ball for water cooler complete all as specified and directed. |
| 130 | S&F in replacement of Liquid line filter one way / two way for water cooler complete all as specified and directed. |
| 131 | Supply and fixing in replacement of waste washing tray including PVC pipe connection of existing shape & size for water cooler as required at site complete all as specified and directed. |
| 132 | S&F in replacement of condenser coil with copper tube and aluminium fins for water coolers suitable for up to 40 / 80/ 150 Ltrs capacity of any make and type complete all as specified and directed. |
| 133 | M&L for cutting out worn bottom and sheet base frame including mild steel legs from water coolers of any make and capacity and fixing the same with new plain galvanised iron sheet 16 SWG of existing size and new angle iron base frame and legs of existing size with and including necessary gas welding and providing nuts / bolts etc complete all as specified and directed. |
| 134 | M&L for minor denting work and applying a coat of spray painting to water cooler with synthetic enamel paint after proper scraping of old rusted painted surface complete all as specified and directed. |
| 135 | M&L for replacement of defective sealed compressor unit of 320 / 400 ltr cap deep freezer.The rates quoted by the contractor shall be inclusive of all charges like transportation fitting etc complete with necessary guarantee periodincluding checking and rectification of any leakage in system and make in functional to entire satisfaction of EIC incl oiling, greasing, gas charging and testing complete all as specified and directed. |
| 136 | M&L for finding out leakage with the pressure testing of the condensor / cooling unit / compressor of deep freezer 320 / 400 Ltr cap including dismantling the same for recharging and stop leakage by brizing / soldering including charging the R-134A gas (or reqd type) to required level and testing the deep freezer for the entire satisfaction of EIC complete all as specified and directed. |