}

Tender For Repair And Maintenance Of Street Lights Looping Fpbs Street Light Timers And Connected Items At Dappar Under Age I Dappar, dappar-Punjab

Tender Notice

52273599
Tender For Repair And Maintenance Of Street Lights Looping Fpbs Street Light Timers And Connected Items At Dappar Under Age I Dappar
Tender
Indian
Punjab
Dappar
01-12-2025

Tender Details

Tender For Repair And Maintenance Of Street Lights Looping Fpbs Street Light Timers And Connected Items At Dappar Under Age I Dappar; 1 Taking out old unsv LT cablecomplete al as specified and as directed by Engineer-in-charge. 2 Supply, laying, connecting and testing or passing through pipe, XLPE 1100 volts grade heavy duty underground cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire 10 sq mm 2 core normal cross sectional area complete all as specified and as directed by Engineer-in-Charge. Note : All minor spares such as cable gland, aluminium lugs etc & minor jobs such as cutting, welding etc is deemed to be included in the quoted rates. 3 All as per item No 2here in before butcable ofsize 4 core 16 sqmm. 4 All as per item No 2 here in before butcable of size 4 core 25 sqmm. 5 All as per item No 2 here in beforebutcable of size3.5 core 35 sqmm. 6 Supply and fixing in replacementstreet/security light bracket made out of 40mm dia light grade 1.5mtr bent to shape for fixing on any type of pole/wall with clamps nuts and bolts complete al as specified and as directed by Engineer-in-charge. Note: Cost of necessary GI items such as reducer, coupler, etc. required to be fitted with GI bracket so as to proper fittment of luminaries with bracket is deemed to be included in the quoted rate. 7 Supply and fixing in replacement electronic driver with power factor correction suitable for 70-90 watt LED street lights, input voltage 70VAC to 300VAC,power factor 0.99(Unity) , overvoltage 300V cuttoff ,short and open circuit protection isolated,surge protection up to10 to 12Kv,maximum output voltage DC 22-38V, maximum current up to1.5amp waterproof level :IP65, shellmaterial :aluminium with IS15885complete al as specified and as directed by Engineer-in-charge. 8 Supply and fixing in replacement electronic driver with power factor correction suitable for 45-60 Watt LED street lights, input AC 85-300V, input frequency 50/60Hz, output voltage DC 22-38V, output current 1500mA(+/-) 5%,waterproof level :IP65, shell material : aluminium with IS15885,complete al as specified and as directed by Engineer-in-charge. 9 Supply and fixing in replacement of weather proof aluminum conductor 4 sqmm 2 core, flat cable for connection complete al as specified and as directed by Engineer-in-charge. 10 Supply and fixing in replacement of weather proof aluminum conductor 6 sqmm 2 core, flat cable for connection complete all as specified and as directed. 11 Supply and fixing in replacement of old unvs box Street light control junction box 280x170x130mm from cable looping box to the connector of the luminarie made out of FRP sheetand arrangement3 phase 4 wire system with R.Y.B.& N studs and control for incoming & outgoing cables with MCB SP 10 Amps 230 volts with neutral link including flat iron 25x3 mm “D” clamps (2 Nos) suitable for mounting of box to pole /Angle of requiredsize & shapeincluding bolts nuts & washers complete all as specified and as directed.. Note: - The quoted rate is deemed to be inclusive of cost of suitable size incoming & outgoing cable glands & lugs. 12 Day to daycomplaints of street lights/ Hight mast light of various type for working height varies from 5m to 16m in the jurisdiction of AGE(I),DAPPAR incl removing carbon from LED light connection by deploying dedicated team having the experience in the same field. Contractor has to provide all required Tool and plants for street light fault rectification. Contractor will make record of all given complaints and rectified complaints updated on daily basis.Street light complaints should be rectified with in 24hrs after intimation via any communication mode. If the complaint is not rectified with in stipulated time contractor will be penality of Rs 100 per day per complaintcomplete all as specified and as directed by Engineer-in-charge.Notes :- (i) Necessary suitable vehicle shall be contractors own arrangement for carrying man power, tools and store. (ii)One repair/replacement of street lights shall be counted as one job. (iii) The complete arrangement ie. veh, manpower tool and plants, adhesive tape roll etc is enclusive in this quoted rate.(vi) any other item required will be measure and paid separately. 13 Excavation in trenches not exc 1.5 m wide and not exc 1.5 mdepth for foundation, laying of cable, GI pipesetcand getting out as in soft/loose soil complete all as specified and as directed by Engr-in-Charge . 14 Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at level not exc 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge. 15 Returning, filling in trenches including , leveling water and all raming in layers not exc 25 cm in soft / loose soil, complete all as specified and directed by Engr-in-Charge . 16 Material and labour for sand cushioning (dry sand) to underground cable for cable protection 23 cm thick in two layers (8 cm thick before laying of cables and 15 cm thick after laying the cable and punning down the sand to 18 cm thickness.) Complete all as specified and as directed by Engineer-in-Charge.Note:- Only punned thickness 18 cm of sand shall be measured for payment purposes. 17 Supplying and laying un-reinforced precast concrete cable cover, class LV,type 1 flat, size 250mm x 150mm x 40mm all as specified and directed by engr -in-charge. 18 Taking down old unsv light fitting and supply and fix LED flood light fitting 180 watts, IP65 class with separate integral driver and with pressure dia-cast aluminium housing complete all as specified and as directed. Note:- The quoted rate is deemed to be inclusive of cost of minor spares and misc jobs to be carried at site for fittment of luminarie. 19 Taking down old unsv fitting and supply and fix LED flood light fitting 120 watts, IP65 class with separate integral driver and with pressure dia-cast aluminium housing complete all as specified and as directed.Note:- The quoted rate is deemed to be inclusive of cost of minor spares and misc jobs to be carried at site for fittment of luminarie. 20 Taking down old unsv fitting and supply and fix LED flood light fitting 50 watts, IP65 class with separate integral driver and with pressure dia-cast aluminium housing complete all as specified and as directed by Engineer-in-charge.Note:- The quoted rate is deemed to be inclusive of cost of minor spares and misc jobs to be carried at site for fittment of luminarie. 21 Taking down old unsv fitting and supply and fix LED flood light fitting 30 watts, IP65 class with separate integral driver and with pressure dia-cast aluminium housingcomplete all as specified and as directed by Engineer-n-charge.Note:-The quoted rate is deemed to be inclusive of cost of minor spares and misc jobs to be carried at site for fittment of luminarie. 22 Taking down old unsv fitting and supply and fix decorative wall light LED fitting 2way/ 3way/ 4way 12 watts, IP65 class with inbuilt driver, worm white/ white/ green/ Saffron colour and with pressure dia-cast aluminium housing complete all as specified and as directed by Engineer-in-charge.Note:-The quoted rate is deemed to be inclusive of cost of minor spares and misc jobs to be carried at site for fittment of luminarie. 23 Supply and fixing in replacement and commissioning of power contactor of rating 40 Amps, 3 pole, AC3 duty, suitable for operation on 230V/415V, 50Hz AC supply, with coil voltage 230V AC, complete with necessary fixing arrangements, connectors, and mounting accessories, and conforming to IS:13947 (Part-4)/IEC 60947 complete all as specified and directed by Engineer-in-charge. 24 Dismantling and disconnecting unservicable timer, Supply and fixingThree-Phase load of 5 KW for automatic Street Light control Switch using Infrared Sensor based NATURAL SWITCH for automatic switching of Street Lights. Nature Switch operation should be based on Natural Light Lux* level, required illuminance Level for Switching ON is ≤ 30 Lux and for Switching OFF ≥ 10 Lux. The Sensor should have part night operation facility of minimum 4 hrs. to max. 12 hrs. The Sensor along with 3 Nos suitable Contactor each 20 to 25 Amp current rating incoming MCBs & Outgoing MCBs of 20-25 Amps (03 Nos) and circuit should also have provision for manual operation (i.e. Sensor Bye-pass option). circuit should be multistrand FRLSH min size ofminmum 10 sq.mm copper cable. Selection operation should be enclosed in a pole/wall mounted enclosure made of rust proof, electric shock proof termite proof and FR grade special mounting compound SMC junction box confirming to IP 54 including taking down old unserviceable timer any type complete all as specified and as directed by Engineer-in-Charge. 25 Material and labour for Painting of steel tubular poles up to 9 meters height with two coats of aluminum paint (ISI marked) over a coat of red oxide zinc chromate primer, after thoroughly cleaning the surface of all rust, dust, grease, and old paint using wire brush/emery paper. The work includes numbering or naming of poles with black enamel paint, letters not less than 75 mm (3 inches) high on a yellow background of size not less than 150 mm × 100 mm, complete all as specified and directed by Engineer-in-Charge 26 Supply and fixing in replacement ofLED LUMINARIE, pressure die cast aluminum housing, 70watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete all as directed and specified by Engr-in-charge. NOTE:- Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 27 S&F in replacement of LED LUMINARIE, pressure die cast aluminum housing, 45 watts capacity, 240V, IP 65 class, with suitable in-built electronic driver complete all as directed and specified by Engr-in-charge. NOTE - Cost of all minor spares and jobs required for fixing of light fixture on wall and for electrical connections are deemed to be included in the quoted rate. 28 Supply and fixing in replacement of classic look metal sheet housing with sealed clear acrylic cover Decorative Street Light LED fitting of 80 watt having dimensions as length not less than 516+- 5mm and width not less th +- 5mm IP 66with integrated constant current electronic driver having operating voltage range 120V -280Vwith APFC (SMPS based constant current supply),lower THD , Open circuit protection,over current protection,surge voltage protection > 4kV having SMD LED array technology having> 50000 burning hours,3000K (warm white),CRI>70 all as specified and directed by Engineer-in-charge. 29 Dismantling and taking out steel poles/struts/PCC poles of any size including demolition of PCC foundation complete all as directed by Engineer-in-charge. 30 Material and labour for erection of internally and externally hot-dip galvanized smart pole of 7.0 meter height, fabricated from 3.0 mm thick steel sheet of grade S355JO, octagonal in cross-section, with integral camouflaged junction box for housing control gear, provided with flush-type lockable door. Pole shall have base plate of size 220 mm × 220 mm × 12 mmand includinggrouting of poleon a suitable shallow foundation using M-15 grade concrete, with 4 Nos. foundation bolts of 20 mm dia and 700 mm length along with 4 mm thick anchor plate. Pole shall be mounted with pole-top hot-dip galvanized spigot-type single-arm street light bracket of 700 mm length, complete all as per OEM’s technical specifications and to the entire satisfaction of the Engineer-in-Charge 31 Material and labour for erection of internally and externally hot-dip galvanized smart pole of 7.0 meter height, fabricated from 3.0 mm thick steel sheet of grade S355JO, octagonal in cross-section, with integral camouflaged junction box for housing control gear, provided with flush-type lockable door. Pole shall have base plate of size 220 mm × 220 mm × 12 mm and includinggrouting of pole on a suitable shallow foundation using M-15 grade concrete, with 4 Nos. foundation bolts of 20 mm dia and 700 mm length along with 4 mm thick anchor plate. Pole shall be mounted with pole-top hot-dip galvanized spigot-type single-arm street light bracket of 700 mm length, complete all as per OEM’s technical specifications and to the entire satisfaction of the Engineer-in-Charge 32 Material and Labour for cement concrete 1:4:8 type D- 2 using 40mm graded crushed stone aggregate in foundations, filling and mass concrete for poles/struts/stays assembly complete all as specified and directed by Engr-in-Charge. 33 Material & Labour for cement concrete 1:2:4 type B - 1 using 20mm graded crushed stone aggregate in coping pedestal to poles including provision of necessary frame work finishing the expossed surface even and smooth complete all as specified and directed by Engineer-in-Charge. 34 Dismantling of unserviceable cross arms of MS Chanel/angle sections etc complete all asdirectedby Engneer-in-charge. 35 Material and labour for MS cross arms, bracing, supports, clamps and back plates fabricated from structual steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicted and inclusive of one primer coat one under coat and two finishing coat of aluminium paint complete all all as directed by Engineer-in-charge. 36 Restringing and fixingACSR Conductor reinforced of any size to proper sag including binding on insulator all as specified and as directed by Engineer-in-Charge 37 Cutting & trimming of tree branches (up to 25 cm dia as one span)any girth and sizearound overhead lines to a clear distance 1.5 mtr both sides of overhead line with in a 25 to 50 mtrs span gap of HT/LT linesincluding clearing the site complete all as specified and directed by the Engineer-in-Charge. 38 Material and labour for replacement of stay assembly complete with accessories as shown in electric plate No.I including loop type insulator, stay clamps etc complete all as specified & directed with diameter of stay 20 mm of stay rod complete all as specified and as directed by Engineer-in-charge.Note: - Loop type insulator, PCC foundation, Exc & earth work & GI stay strand will be measured and paid seperately under relevent items of Sch A 39 M aterial and labourfor earthingwith galvanised iron earth plate of size 600x600x6mm thick buried directly in ground not less than 2.25m below normal ground level,earth plate packed on all sides with charcoal mixed with salt in alternate layers of 15 cm thickness connected by galvanised iron earth strip 32x6mm soldered & riveted toearth plate, galvanised iron earth strip will be provided by using 50mm bore galvanised iron pipe (light grade) earth plate to transformer body and neutralor test point of transformer, including flat iron clamp 25x4mm including bolts, nuts and washers complete including watering galvanised iron pipe 20 mm dia Light grade 2.5mm long the earthing includes PCC pit including necessary earth works and disposal of surplus soil to a distance not less than 50m, chamber of PCC 1:4:8 type D-2 using 40mm graded stone aggregate, coping shall be of PCC 1:3:6 type C-I using 20mm graded stone aggregate, RCC pit cover 50mm thick in1:2:4 type B-I using 20mm graded stone aggregate, rein forced with 8mm dia @ 15cm c/c complete all as shown on sketch No 3 of SSR-I of 2009 and as specified and as directed by Engineer-in-Charge. 40 Supply and fixing in repairs 5-32 A SP MCB, 10 kA C series, 240 V AC, 50 Hzcomplete switch gear/components in various street light poles all as specified and directed by Engineer-in-Charge 41 Supply and fixing in repairs 63A TPN MCB, 10 kA C series, 415 V AC, 50 Hz complete switch gear/components in various APFC panels all as specified and directed by Engineer-in-Charge. 42 Supply and replacethe existing u/s indicating lamp LED type suitable to operate on 230 volts ACR/Y/B colour as per site requirement all as specified and directed by Engineer-in-charge. 43 S&F in replacement Single function 3 phase LED ammeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable all as specified and directed. 44 Supply and fixing in replacement Single function 3 phase LED voltmeter with accuracy Class 1.0, Flush mounting 96 x 96 mm, Input voltage measurement range 50-520 VAC (P-P), CT/PT site programmable complete all as specified and directed by Engineer-in-charge. 45 Supply and replace the existing u/s selector switch 16 A ,R/Y/B marking for voltmeter complete all as specified and directed by Engineer-in-charge. 46 Supply and fixing in replacement u/s selector switch16 A ,R/Y/B marking for Ammeter complete all as specified and directed by Engineer-in-charge. 47 Supply and fixing in replacement unserviceable CT of 100/5 ratio 15VA class -1 ,3-phase complete all as specified and directed by Engineer-in-charge. 48 Material and labour for painting to electric control panel of E/M installations by cleaning the existing old paint with the help of mechanical tools such as wire brush, scraper and sand paper from the surface of panel and painting the prepared surface with two coat of synthatic enamel paint of approved shade over a coat of red oxide primer complete all as specified and as directed by Engineer-in-charge. 49 Supply and fixingcable jointing kit for 1100 V grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Aluminium conductor cable of size upto 16 to 35 sqmm, core outdoor type and taking down fault complete all as specified and directed by Engineer-in-Charge. 50 Materil and labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed by Engineer-in-charge. Notes:- (a). Cost of cutting out of trench for accomodating the machine and making good to the surface after completion of the job are deemed to be inclusive in the quoted rate. (b). Contractor has to rectify any damage to cables, pipes or other govt. property free of cost to the complete satisfaction of Engr-in-Charge. (c). Any extra excavation or the any other connected jobs required other than as mentioned in the scope of work will be measured and paid under the relevant items of this schedule. 51 Material and labour for galvanized iron tubing size 40 mm bore (Light grade) with all necessary fittings laid in trenches under road crossing or fixed on poles / walls / under floors for cable protection complete all as specfied and as directed by Engineer-in-Charge. 52 Supply and fixing in replacement LED All in one solar street light fitting 40 W with in-built Lithium ferro phosphate bettery 12V, 35 AH, IP-65, Monocrystaline silicon panel & 40 (20 x 2) W LED , CRI>80, Lighting efficency upto 120LM/W, CCT-6000 to 6500 Deg K, 12.8V 35 AH lithum (lifePo4) battery, Full power upto 12hrs: Saving mode upto 48 hrs, integral PIR Sensor, MPPT Charge controller with 90 to 96% efficiency, including fixed of 6 mtr height of Pole of 100mm dia medium grade GI with Aluminium paint/ Metal Black Paint, Hybrid (AC-DC) option available, with in-built BMS technology, MPPT Solar charger controlleras fitted complete all as specified and as directed by Engineer-in-charge. 53 Supply and fixing weather proof Copper conductor 1.5 sqmm 2 core, Round cable for connection from looping box to street light fitting in side the existing pole complete all as specified and as directed by Engineer-in-charge.. 54 Taking out existing High mast Pole and re-erect the same pole on another location including dismantling safely & refixing/ reconnecting of any type of fittings by mechanical means complete allas directed by Engineer-in-charge.Note: Excavation / PCC work wil be paid separately. 55 Supply and fixing in replacement of Tri-Colour/ Indian Tiranga rope light/ Strip light with all 3 colours (orange+White+Green) of 18 Mtr length with IP 65 and more than 3KV surge protection, Lumen output - more than 400lm per meter, out door type, with silicon cover, power source AC plug and play with connecting cord on street light pole upto 15 Mtr hight,all as specified and directed by Engineer-in-charge.Note: Takingdown poleand refixing of Pole/Bracket after connection is including in this quoted rate 56 Material and labour for opening and checking of non-functional solar LED lights including removal from pole, checking internal battery, controller, LED, wiring,Cleaning of solar PV panels including removing dust/debris and washing with clean wate etc. and refixing after repair complete allas directed by Engineer-in-charge.. 57 Supply and fixing in replacement LED 2x 20W light fitting suitable for solar application with inbuilt charge controller complete allas directed by Engineer-in-charge. 58 Supply and fixing in replacementLi-ion battery 12V, 35Ah capacity suitable for inbuilt solar street light fitting, including terminal connectionscomplete allas directed by Engineer-in-charge.. 59 Supply and fix in replacement solar charge controller PCB suitable for 35/40W LED street light with dusk-to-dawn automatic function complete allas directed by Engineer-in-charge.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 25 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail