Tender For Special Repair To Toilet Bathroom In Bldg No P-70 At Certain Unit Of Misa Camp Under Ge (S) Tezpur; 1 Demolition ofcement concrete in roofs, floors (other than ground floor), beams, staircase, landing, chhajjas and similar suspended work including removing rubbish off the premises complete all as specified and directed. 2 Demolition of cement concrete (reinforced)of any description andin anypositionnot otherwise specifically provided for complete all as directed. 3 Demolition of brick work built in cement mortor including all quoins, arches, pillars etc and all as specified . 4 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 5 Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. 6 Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. 7 Taking down cement or cement lime plaster any description on any walls etc including raking out joints, hacking for key, scrubbing down with water etc 8 Taking down and refixing in same/other opening door shutter of any description exc. 1 sqm but not exc. 2 sqm each complete all as specified and directed. 9 Taking down existing roof tretment of any size comlete all as specified and directed. 10 Taking up or down water pipe tubing and connections, including cleaning for re-fixing or removal to store Outer diameter of pipes : 15 mm 11 Taking up or downwater pipe tubing and connections, including cleaning for re-fixing or removal to store Outer diameter of pipes :20 mm 12 M&L for 25 mm thick Cementconcrete type B-1, 1:2:4 (20mm graded aggregate) with integral water proofing compound as in sunken floor (MAKE : Dr fixit, pedilite, fosroc or equivalent)( Note: WPC shall be paid seprately) 13 M&L for 20mm thick rendering in cement mortar (1:4) mixed with water proofing compound @ 3% and applying water proofing treatment on sunken portion with acrylic based polymer modifed cementitious composit compound as specified and approved & cement slurry two layers, 1st layer @ 0.488 Kg/ Sqm mixed with composit compound @ 0.253 Kg/Sqm, & the second layer slurry @0.242 Kg/Sqm mixed 0.126 Kg of compound complete with minimum 4 hours allowed to air cure between these layers and applying 200 µ polyflim with adhesive.complete all as specified and directed by Engineer-in-Charge. 14 M & L for cement concrete type E2, 1:5:10 (40mm graded aggregate) as in mass concrete in sunken floors complete all as specified and directed. 15 S&F 40mm dia GI pipe, medium grade as in spout pipe in sunken floor complete all as specified and directed. 16 M & L for screed bed or bedding layer of mortar, 15 mm thick, in cement mortar 1:6, for laying floor finishes complete all as specified and directed. 17 M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.18 Sqm but not exc. 0.38 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed. 18 M & L for rendering 10 mm thick in cement mortar 1:4 on fair faces of brick or concrete surfaces finished even and rough for receiving wall tiles/dado/skirting completeall as specified and directed. 19 M & L for glazed ceramic tiles in vertical surface 450X 300X 7-8 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match to match the surface of tile complete all as specified and directed. 20 M & L for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat ,louvers for fixing of glass in ventilators and powder coated (minimum thickness of powder coating 50 micron)etc. complete all as specified and directed 21 M&L for Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots ,necessary fittingsand making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket requiredwith extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-Charge. 22 M&L for4.00 mm thick frosted glass, ordinary quality and glazingfixed in aluminium frames in square/rectanglenot exc 0.5 sq. m in each panecomplete all as specified and directed 23 S & F instainlesssteel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed 24 Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing 25 Factory made solid panel pvc door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded prelam colour PVC `C channel heaving a PVC sheert strip of 20mm width suck inside with solvent cement for stiles and prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling ofboth side Prelam PVC sheet to be fitted in the M.S frame welded/sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. 26 S & F of 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed. 27 S & F of 100 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed. 28 S & F of 150 mm long extruded anodised aluminium alloy handle, fabricated type complete all as specified and directed. 29 M&L for brickwork with subclass‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. 30 M&L for rendering 15 mm thick onfaces of brick work or concrete surface in CM (1:6), finished even and smooth without using extra cementcomplete all as specified and directed. 31 Rendering 5 mm thick on fair faces of brick work or concrete surface in CM (1:3) as in ceiling, finished even and smooth without using extra cement 32 M&L for 20 mm thick rendering with cement mortar (1:4)on fair faces of brick work in two layers (10mm & 10mm)seperately mixed with water proofing compound in top layer as per manufacturers instructions and finishing the surface even and smooth without using extra cement complete all as specified and as directed.Note:- WPC shall be measured and paid seperately under appropiate item. 33 Supply only liquid water proofing compound complete all as specified and directed. 34 M & L for preparation of newly plastered surfaces of wall and applying twocoatsof oil bound distemper over a coat of primer over and including a coat of 1mm thick white putty complete all as specified and directed. 35 M & L for complete removal of existing treatment and applying twocoatsof oil bound distemper over a coat of primer over and including a coat of 1mm thick white putty complete all as specified and directed. 36 M&L for finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coatof exterior primer applied @ 2.20 kg/10 sqm) overa coat of 1 mm thick wall care puttysuitable for exterior emulsion paint Allow 6-8 hrs to dry the surface in both the coats of paint complete all as directed. 37 M&L for finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coatof exterior primer applied @ 2.20 kg/10 sqm) overa coat of 1 mm thick wall care puttysuitable for exterior emulsion paint Allow 6-8 hrs to dry the surface in both the coats of paint including complete removal of existing treatment on wall/ roof projections including facia,cornices etc by scrapping to make surface clean,free from dust,loose paint etc by skilled labour complete all as specified and directed. 38 M&L for applying neat cement slurry over existing roof surface @ 3.0kg of cement per sq. metre complete all as specified and directed. 39 M&L for PCC (1:2:4) type B-0 using 10/12.5 mm graded stone aggregate laid over roof slab after applying cement slurry for filling undulations finsished even and smooth without using extra cement complete all as specified and directed. 40 M&L for 15 mm thick rendering in CM (1:3) mixed with liquid water proofing compound as per manufacturers instructionsover RCC roof slabs for laying water proofing treatment and surfacefinished even and smooth complete all as specified and directed. Note :-(WPC will be measured and paid separately) 41 Supply and fix APP polymeric water proofing membrane,minimum 3mm thick and weighing not less than 3.5 kg/sqm,black finish reinforced with non-woven polyster reinforcement matt with a thermo fusable finish laid over compatible cold emulsion bituminous primer applied at the rate of 0.40 kg/sqm by torching with a propane or a butane gas torce with a overlap of 75 mm on a longitudinal direction and 100 mm on transverse direction including sealing all as per manufacturers instruction complete all as directed. 42 Note : (i) Cover fillets in PCC (1:2:4) type B-0 using 12.5mm graded stone aggregateof radius 75mm shall be provided at the junction of roof and parapet wall/mumty/chimney/other vertical surfaces and thereafter surface painted with hot paving bitumen of grade 30/40 conforming to IS-73,applied @1.2 kg/sqm over a coat of bituminous primer conforming to IS-3384 appled @0.40 kg/sqm(ii) Polymeric membrane shall be taken to a height of 45 cm (minimum) and then inserted inside the groove of parapet wall of brick masonry and shall be finished by a membrane flushing(iii) The water proofing treatment shall be got carried out by the manufacturer or their authorized applicators(iv) In case of stone masonry parapet wall etc a groove of size 25mm x 25mm (minimum) shall be made in cover fillet at the junction of roof and parapet wall / mumpty/ other vertical surfaces and polymeric membrane inserted in groove and sealed with paving bitumen(v) Exposed surfaces of APP membrane shall be applied with one coat of bituminous aluminium paint @ 100gms/sqm 43 Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding10 cm but not exc 20 cm girth 44 Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including cutting through walls together with all tube fittings (such as bends, elbows, tees, short pieces, connectors, backnuts,diminishing pieces, caps, plugs and unions, etc.) and fixing complete with clips, wall hooks, wooden plugs, complete all as specified. 45 (a) Outer diameter of pipes :20mm 46 (b) Outer diameter of pipes :32 mm 47 S&F of male Brass Threaded Adaptor (MTA/ MBTA) for cPVC pipe of outer diameter : 20 mm complete all as specified and directed. 48 S&F of female Brass Threaded Adaptor(FTA/ FBTA) for cPVC pipe of outer diameter : 20 mm complete all as specified and directed. 49 S&F of Tank Adaptor for cPVC pipe of outer diameter : 32 mm complete all as specified and directed. 50 S&F of 500 litre capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part IRotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including dismantling the old one complete all as specified and directed. 51 S & F in repairs 20mm dia ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixedcomplete all as specified and directed 52 M&L for formwork to soffits of suspended slabs such as roof slabs, floorslabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)complete all as specified and directed 53 M&L for RCC (nominal mix) (1:2:4) type B1 using 20mm graged stone agreegateSlabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. 54 M&L 18-20 mm Granite (of any type) thick machine cut, as in table slab for table top basin, for bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including 20mm thick screed bed or bedding layer cement mortar (1:6) and making hole for waste coupling complete all as specified and directed. 55 M&L Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. 56 M&L 18-20 mm Granite (of any type) thick machine cut, as in table slab for table top basin skirting/vertical surface,bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete including 15mm thick screed bed or bedding layer cement mortar (1:4)complete all as specified and directed. 57 S & F coloured vitreous china half stall urinalwith grating and union for discharge pipe including, waste pipe and PVC connection, bedding urinal against wall in cement mortar 1:2 securing urinal to to wall all as per manufacturer instructions complete all as specified and directed by Engineer-in-Charge. 58 S & F of vitreous china squatting pan, orissa pattern size 580 X440 mm white/colour with integral foot rest (excluding flushing cistern and flush pipe) including provison of lime concrete 59 S & F in repairs PVC valveless, syphonic action type, wall hung 10 litres flushing cistern, low level, white with inlet ball valve foat and handle including brackets 60 S & F in repairs15mm bore brass chromium plated fancy typebib cock with wall flange screwed down, screwed for iron pipe or for brass ferrulecomplete all as specified and directed. 61 S&F of vitreous china below counter wash hand basin Geneve N of Parryware of Cat Part No C-0441 or equivalent Make of Cera/Johnson/Prayag of size 515 x 420 x 192mm with and including fixing in counter and 32 mm dia PVC waste pipe and 32mm size waste fittings, brass chromium plated with long screwed shanks and fly nuts, flange end, bedded in red lead cement and other fixed (excluding tap, waste chain and plug) complete all as specified and directed. 62 S&F 15 mm bore fancy and swan neck type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. 63 S&F for 32mm dia waste coupling, brass, chromium plated for glazed ware sinks, table top basins etc with long screwed shanks and fly nuts, flange and bedded in red lead cement and other end fixed complete all as specified and directed. 64 S&F for PVC connection pipe 15mm dia with PTMT nuts of length 600mm complete all as specified and directed. 65 S&F Reflection looking mirror of 6mm thick fixed to wall with chromium plated brass screws and cup washers all asspecified and as directed. 66 S&F in repair CP Towel Ring fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90gms) 67 S&F of 15 mm dia Brass CP, wall mixer 2 in 1 system with provision for both hand and overhead shower complete with 115 mm long bend pipe, connecting legs and wall flange (without Hand and overhead shower) (Concealed type) screwed both ends for iron pipe or for unions complete all as specified and as directed. 68 S & F of Overhead Shower 150mm x 150mm square shape single flow ABS body Chrome plated with gray face plate with rubit cleaning system including provision of 450mm long chromium plated best quality shower arm complete all as specified and as directed. 69 S & Fin repair 125mm dia PTMT grating doom with waste hole for wastepipe ( minimum weight 40 gram) complete all as specified. 70 S&F in repair15 mm dia Fancy type Chromium plated Angle valves, cast copper alloy screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed 71 S & F in repair110 mm dia PVC (SWR) pipes single socketd, in any length with rubber ring joints fixed to wall with stack clamp complete all as specified and directed. 72 S&F in repair of 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors 73 S&F in repair of 110 mm dia PVC (SWR) vent cowl 74 S&F in repair of110 mm dia PVC (SWR) bends any radius 75 S&F PVC (SWR) floor trap 125/110 mm, setting and jointing with solvent cement 76 Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete,including fixture and fittings such as switches,ceiling roses,pendants,regulators,sockets,light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc. 77 M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories including modular GI boxes of suitable sizesincluding 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fanpoint controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (Rate deemed to be inclusive of cutting chases and making good disturbed surface). 78 All as per item No. 74 here-in-before but one 3 pin 5 ampsswitch socket commbination on the independent board with other switch complete all as specified and directed by Engineer-in-charge. 79 All as per item No. 74 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge. 80 M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one wayswitch using 2.5 sqmm nominal cross sectional areamultistrandedcopper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including metal flush box suitable for modular cover plate with frame of suitable size of 3M and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly andbrass screws, washers etc. complete all as specified and directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (Rate deemed to be inclusive of cutting chases and making good disturbed surface). 81 M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one wayswitch using4.0 sqmm nominal cross sectional areamultistrandedcopper conductor, PVC insulated unsheathed FRLSH cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including metal flush box suitable for modular cover plate with frame of suitable size of 3M and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor FRLSHPVC insulated unsheathed earth wire and connecting to earth dolly andbrass screws, washers etc. complete all as specified and directed.(Rate deemed to be inclusive of cutting chases and making good disturbed surface). 82 S&FModular type switch6 Amps 230V AC single module one way complete all as specified and as directed. 83 S&F Modular socket out let 3 pin 10 Amps shuttered type 230V AC 2 module complete all as specified and as directed. 84 S&F Modular socket out let 3 pin 16 Amps shuttered type 230V AC 2 module complete all as specified and as directed. 85 S&FModular type switch16 Amps 230V AC single module one way complete all as specified and as directed. 86 S&FCeiling rose, surface bakelite, 65 x 50 mm,three terminals complete all as specified and directed. 87 Supply & fixing lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings complete all as specified. 88 Supply and fixing modular white cover plate with frame 2 modules complete all as specified and as directed. 89 Supply and fixing modular white cover plate with frame 3 modules complete all as specified and as directed. 90 Supply and fixing modular white cover plate with frame 4 modules complete all as specified and as directed. 91 Supply and fixing modular white cover plate with frame 6 modules complete all as specified and as directed. 92 Supply and fixing modular white cover plate with frame 8 modules complete all as specified and as directed. 93 Supplying and fixing in repairtwo single core ,6 sqmm nominal cross sectional areamultistrandedcopper conductor FR cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including nd including suitable size PVC conduit (ISI marked) concealed including6 sqmm nominal cross sectional areamultistrandedcopper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earthwirecomplete all as specified. Note : Two run of 6 sqmm wire with one run of 6 sqmm and one run of casing capaing / conduit pipe shall be measured against one unit. 94 Supply and fixed in repair 18 W LED light fitting wall mounted batten 4ft ,minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6500K including necessary connection complete all as specified and directed. 95 Supply and fixed in repair 10 W LED light fitting wall mounted batten 2ft ,minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 09 watt,6500K including necessary connection complete all as specified and directed. 96 Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door, Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed. 97 Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel ,neutral link and incoming contact complete all as directed. 98 Supply and fixed in repairsMCB SP,6 to 32 Amps, C series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed. 99 Supply and fixed in repairs MCB SPN 6-32 Amps,C series 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 100 Supply and fixed in repairs MCB TPN 63 Amps,C series 10kA, 415 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 101 Taking down of AC exhaust fan of any sweep & any height and opening the fan and oiling, greasing andreplacementofunserviceable accessories and servicing, complete overhauling and re-assembling and testing complete for efficient functioning and fixing it back in position including provn of 0.5 Sqmm copper flexible twin twisted cable (length not exceeding 0.5 metre) from ceiling rose to fan as directed by the Engr-in-Charge. 102 Taking down existing Geyser of any size and make upto 25 ltrs carefully, by diconnecting electrical and water pipe line connection and deposite at MES Yard/store for refixing. 103 Refixing of existing Geyser 25 ltrs as per above item by connecting electrical and water pipe line connection.