Tender For Provision Of B/R And E/M Wks At Various Locations Of Misa Camp Under Ge (S) Tezpur; 1 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft and loose soil complete all as sfd and as directed. 2 Excavation in trenches n.exc 1.5m deep & n.exc1.5m wide on plan in soft/loose soil and getting out. 3 M & L for Plain cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation filling and mass concrete all as specified. 4 M&L for earth filling under floor or in foundations including watering and consolidation complete all as specified and directed. 5 M&L for Hard core of gauge n exc 63 mm of broken boulder bellow plinth protection/hard standing/floor.Complete all as specified and as directed. 6 M & L for Damp proof course 25 mm thk in PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate to horizontal or vertical surface 7 M & L for formwork to sides of concrete foundations, footings, bases of columns, rafts raft beams, sides and soffits ( if any ) of foundation and plinth beams; and similar work; vertical or batter, finished rough surfaces of concrete, complete all as specified and directed. 8 M & L for formwork to chullah hoods, chajjas, trough and similar items including edges finished rough surfaces of concrete complete all as specified. 9 M & L for formwork to sides and soffits of lintels,lintel bend, beams etc finished rough surfaces of concrete complete all as specified. 10 M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular finishes rough surfaces of concrete.etc finished rough surfaces of concrete complete all as specified. 11 M&L for RCC 1:1.5:3 type B1 using 20 mm graded crushed stone aggregate as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, etc; basement slabs, under reamed piles and mass concrete all as specified and directed. 12 M & L for RCC1:1.5:3 type B1 using 20 mm graded crushed stone aggregate as in chajjas and the like all as specified and directed. 13 M&L for RCC1:1.5:3 type B1 using 20 mm graded crushed stone aggregate) as in beams, cantilevers, lintels, over 1.5 m spanall as specified and directed. 14 M&Lfor RCC1:1.5:3 type B1 using 20 mm graded crushed stone aggregate as in columns, pillars, piers, posts and struts all as specified and directed. 15 M&L for RCC1:1.5:3 type B1 using 20 mm graded crushed stone aggregate as in beams, cantilevers, lintels, over 1.5 m span all as specified and directed. 16 M&L for RCC1:1.5:3 type B1 using 20 mm graded crushed stone aggregate as in slab, shelves etc.all as specified and directed. 17 M&L for Form work to soffits of suspended slabs flat surface of concrete finishedrough surfaces of concrete not exceeding 200mm thick, complete all as specified and directed. 18 S&F TMT bars 5mm and over upto and including 10mm dia in stirrups, spacers and binders bent to shape required,including binding with mild steel wire (annealed) not less than .9mm dia complete all as specified and directed. 19 S&F TMT bars 10mm dia and over, cut to length, bent to shape required,including binding with mild steel wire (annealed) not less than 0.9mm dia confirming to Gde Fe 500 D, complete all as specified and directed. 20 Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. 21 S&F pressed steel frames of 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed. 22 Removing excavated material n exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. 23 S&F 35 mm thickfactory made flush shutter, solid core construction with block board core and ply wood face panels, commercial type on both side, complete all as specified & directed. 24 S&F 2nd class hardwood 35mm thick glazed and skeleton shutters open rebated and prepared to receive glass gauge etc.Divided into squares with plain chamfered or rounded, rebated sash bars, sizes of the members of the shutters as specified in SSR Part I, section 8, clause 8.23(a). 25 S&F 200 mm long,aluminium,anodised, barrel tower bolts of extruded section all as described complete all as specified and directed. 26 S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet,cast or extruded sections and fixing boltsand sliding bolts of extruded sections or cast aluminium alloy all as directed. 27 S&F for extruded aluminium alloy handle fabricated type of 150 mm long 28 M & L for cement concrete type D-2, 1:4:8 ( using 40 mm graded crushed stone aggregate ) 75 mm thick as in sub base of floors. 29 S&F 100 mm Butt hinges medium weight cold rolled mild steel and fixed. 30 S&F MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified 31 M&L for 18-20 mm thick machine cut kota stone slab (table rubbed and polished) as in flooring laid over and including 15 mm thick screed bed or bedding layer in CM (1:6), set and jointed with grey cement slurry mixed with pigment to match the shade of slab including cutting, rubbing, grinding and mirror polishing upto desired satisfaction of Engr In Charge complete all as specfied and directed. 32 M&L for machine cut kota stone slab18-20 mm thick as in skirting,risers of steps laid over cement screedand jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing, laid our including rendering 15mm thick on brick wall or concrete surfaces in cement mortar 1:6 for fixing of tiles complete all as sfd and directed. 33 M & L for rendering 15mm thick on brick wall or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified 34 M & L for rendering 15mm thick on brick wall or concrete surface consisting two layers, under layer of 10mm thick in CM (1:4) & top layer of 5mm thick in cement mortar 1:4 mixed with water proofing compound, finished even and smooth without using extra cement complete all as specified and directed. (Note:- Water proofing compound shall be measured and paid saperately.) 35 Supply only water proofing compound @ 1% by the weight at of cement complete all as specified and directed. 36 M&L for 75mm thick PCC 1:3:6 type C2 using 40 mm gradedcrushed stone aggregate as in path/pavings finished rough andlaid in alternate bays to receive chequered tile all as specified and directed. 37 M & L for 15mm thick screed bed or bedding layer in cement mortar1:6 for laying floor finishes, finished even and fair complete all as specified. 38 M & L for 75mm th PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as inplinth protection finished even and smooth without using extra cement complete all as specified. 39 S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars,dovetailed or weldedy complete all as specified and directed by Engineer-in-Charge 40 S&F steel window frame with side hung shutters including boxtype hinges with steel handle and steel pegs stay complete with glazing bars complete all as specified and directed 41 S&F steel ventilators with top hung shutters including hinges, steel peg stay, complete all as specified and directed. 42 M & L for sheet glass ordinary quality 4mm thick and glazing with oil putty in squares n.exc. 0 .5 sqm each pane complete all as specified. 43 M & L for applying two coat of oil bound distemperover a coat of primer over 2 mm thick wall care putty on newly plastered wall surface including preperation of the surface complete all as specified. 44 M&L for brickwork with sub class B bricks stright or curved on plan exc. 6m mean radius built in CM 1:6 complete all as specified and directed. 45 M & L for two coats of exterior emulsion antifungus paint over a coat of primer over a coat of 2 mm thick (minimum) wall care putty to wall including complete including preparation of surface as specified and directed 46 S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in roof covering/clading to wall, fixed with self tapping screws as specified. 47 S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in ridges, roof covering/clading to wall, fixed with self tapping screws as specified. 48 S&F mild steel rolled section conforming to Fe-290 (Gde E-165), as in main and cross beams, hip and jack rafters, purlins where connected to common rafters fixed with angle cleats and other connecting plates etc. complete all as specified and directed. 49 M&L for applying two coats of synthetic enamel paint over a coat of pink primer to new wooden surfaces exc 10 cm width or girth, including preparation of surfaces, complete all as specified and directed. 50 M&L for MS framed work of angle, tee, F.I, conforming to Fe-290 (Gde E-165), as in roof trusses including distance pieces, cleats etc. welding or riveted complete all as specified and directed. 51 S&F mild steel framed work conforming to Fe-290 (Gde E-165), as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete drilled for fixing steel sheeting or other covering to be prepare for hanging including either hooks or hinges etc. 52 S&F anodised aluminium snap grid frame work of 605x605mm size for false ceiling all as specified and directed. 53 M & L for 4mm thick non asbestos fibre cement building board fixed/inserted to Aluminium frame work, as in ceiling complete all as specified and as directed. 54 M & L for applying two coat of distemper on ceilling non asbestos fibre cement building board surfaces , complete all as specified. 55 M&L for preparation of new steelsurfaces and apply 2 coats of syntheticenamelled paint over a coat of red oxide primer over 10cm width or girth 56 M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium dutywith all accessories suitable for metal flush box, modular cover plate with frame of suitable size for mounting switches, sockets,regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fanpoint controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. 57 All as per item No.56 above but One 3 pin 5 Amps socket out let points on independent board 58 All as per item No.56 above but5 Amp socket on same boardwith other switches. 59 M & L for point wiring for socket out let on 16 Amps independent Boards controlled by one, one wayswitch using 2.5 sqmm nominal cross sectional areamultistrandedcopper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, suitable for metal flush box, modular cover plate with frame of suitable size of 3M and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSHPVC insulated unsheathed earth wire and connecting to earth dolly andbrass screws, washers etc. complete all as specified and directed.Note: (i) Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. 60 S&FModular type switch6 Amps 230V AC single module one way complete all as specified and as directed. 61 S&F Modular socket out let 3 pin 10 Amps shuttered type 230V AC 2 module complete all as specified and as directed. 62 S&F Modular socket out let 3 pin 16 Amps shuttered type 230V AC 2 module complete all as specified and as directed. 63 S&FModular type switch16 Amps 230V AC single module one way complete all as specified and as directed. 64 Supply & fixing Ceiling rose, surface bakelite, 65 x 50 mm,three terminals complete all as specified and directed. 65 S&F Modular type fan regulator Step type ,100 Watt, one module, 230V AC complete all as specified and as directed. 66 Supply & fixing lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings complete all as specified. 67 Supply and fixing modular white cover plate with frame 2 modules complete all as specified and as directed. 68 Supply and fixing modular white cover plate with frame 3 modules complete all as specified and as directed. 69 Supply and fixing modular white cover plate with frame 4 modules complete all as specified and as directed. 70 Supply and fixing modular white cover plate with frame 6 modules complete all as specified and as directed. 71 Supply and fixing modular white cover plate with frame 8 modules complete all as specified and as directed. 72 Supply and fixing modular metal flush box 2 modules complete all as specified and as directed. 73 Supply and fixing modular metal flush box 3 modules complete all as specified and as directed. 74 Supply and fixing modular metal flush box 4 modules complete all as specified and as directed. 75 Supply and fixing modular metal flush box 6 modules complete all as specified and as directed. 76 Supply and fixing modular metal flush box 8 modules complete all as specified and as directed. 77 Supplying and fixing two single core ,6 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including nd including suitable size PVC conduit (ISI marked) concealed including6 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earthwirecomplete all as specified. Note : Two run of 6 sqmm wire with one run of 6 sqmm and one run of conduit pipe shall be measured against one unit. 78 Supply and fixed18 W LED light fitting wall mounted batten 4ft ,minimumm lumen output 100 lumen/Wat, extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6500K including necessary connection complete all as specified and directed. 79 Supply and fixed security light fittings 30 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete including 25mm dia light grade GI bracket with nut bolt and clamp complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed. 80 Supply & fix LED bulb 15 watt 6500 k complete all as specified and as directed. 81 Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed. 82 Supply and fixed MCB SP,6 to 32 Amps, C series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed. 83 Supply and fixed MCB SPN 6-32 Amps,C series 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 84 Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased inand including 40 mm dia GI lightgrade pipe from upper end of earth plate upto equipments,20 dia bore GI pipe light grade as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe andPCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SSR Part I completeall as specified and directed and testing on completion. 85 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) all as directed. 86 S & F ventilating exhaust fan300 mm sweep 230 volt AC complete with louver and all accessories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing arrangement to wall connected with twin core twisted flexible copper conductor (23/.0076) of suitable size all as directed. 87 Supply, laying / fixing / connecting, testing and commissioning of 10 sqmm 2 core LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric cable (heavy duty) with multistranded aluminium conductor,1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as directed by the Engr-in-Charge.