Tender For Special Repair To Building No.P-20 (Oht) And Allied Works; 1 Removing the loose particle and funguson the floor areas by using a mechanical grinding machine. Treatments of cracks are cutting on :V: Groove & Filling the surface should be free from oil, Laitance.etc. Water proofing Coating : 1. Providing and applying Asian Paints Apcorep Food Grade Epoxy application, Seal all the cracks, joints etc with Crack seal Mix Apcorep Food Grade Epoxy Base And Curing Agent in equal proportions by volume for 5 minutes. keep it as it is in the container for 10 minutes before applying. 2. Apply minimum two coats of Apcorep Food Grade Epoxy on the surfac keeping minimum 24 hours time interval between them 2 M & L for PU Injection Groutfor leakage, the seepage points to be drilled to a depth of nearly half the thickness of wall, fix a PVC nozzle at 45 degree angle with 18mm Dia holes at all the junctions for every 1.2m c/c for minimum depth of 75mm/ Inject the holes using 120-psi pressure grouting pump with PU injection grout materia Pressure grout with FOSROC Nitofill WS 60 (PU foam ) to arrest the leakages and permanently seal. The rate is Inclusive of all tools,tackles, machinery etc. 3 Taking down cement plaster on brick or stone walls, ceilings, etc including racking out Joints, hacking for key, scrubbing down with water, etc 4 M&L 10 mm thick rendering on fair faces of brick or concrete surface in Cm (1:4) and providing in two layers, with WPC @ 3% of cement and finishing even and smooth without using extra cement. 5 Chipping/removing loose concrete in cloumns/beams/ chajjas/roof slab etc. up to reinforcement bars without damaging the reinforcement, removing all the loose material and to make all the exposedsurface free from dust and all impurities etc complete allspecified and directed. 6 Removing corrosion of steel reinforcement by mechanical means like wire brushing, chipping to remove loose rust and then applying rust removal solution Reebaklens RR of Fosroc / Sika Rust off 100 / equivalent in bostic India Ltd by using brush application, leaving the surface for at least 15 to 30 minutes, then removing loose materials by scrubbing or with brush and applying anti corrosive coating to reinforcement Nitozinc primer of Fosroc/Sika Friazinc R / equivalent in Bostic india Ltd , all as recommended by product manufacturer. 7 Providing and applying one coat of structural grade epoxy coat by brush of approved make . Mixing of two components will be as directed by manufacturer .Application shall be provided not more than 5 hours before application of micro concrete/polymer mortar etc complete all as specified by the manufacturer.Make:- Nitobond EP of FOSROCK/ Sikdur 32LP/ equivalent in Bostic India Ltd 8 Providing and applying n exc 40 mm thick (In layers of each 10mm thick) Shrinkage controlled, polymer modified, fibre reinforced cementitious repair mortar Renderoc SP 40 of Fosroc / Sika plastocrete plus/ equivalent in bostic India ltd, mixed with water in a water & powder ratio 0.18 in ceiling of roof slab/Chajjas/Beams/Parapet walls etc.Note:- Quoted rate is deemed to be inclusive of provideing scaffolding for working in patches upto a height of 25 Mtr complete all as specified and directed. 9 M & L for Providing & fixing double steel scaffolding system (cup lock type) on the exterior side of the building/structure, including additional rows of scaffolding in stepped manner as per requirement at site, made with 40mm dia MS tube, placed 1.5mtr c/c(Maximum), horizantal & vertical MS tubes jointed with cup & lock system in the scaffolding for working platform etc amd maintaining it in a serviceable condition for execution of work and removing it thereafter. the scaffolding system shall be stiffned with bracings, runners, connecting with building etc wherever required to ensure safety of workmen all as directed by Engr-in-charge.Note:- 1.Area derived by multiplying the outer most external perimeter and height of the building /structure shall be measured for payment.2. The payment shall be made only once after completion of all external items of work w.r.t the building/structure. 3. After completion of the work the material of the scaffolding shall be the property of the contractor and required to be removed from the site.4. Proper safety belts and helmets to be provided to the workers at site to follow safety precautions 10 M & L preparation old plasteredof wall surfaces and applyingtwo coats of acrylic smooth exterior paint of required shade (applied @ 1.67ltr/10 Sqm) over and including priming coat of exterior primer @2.20 Kg/10 Sqm) all as specified . 11 Preparation of old treatedof wall surfaces and applyingtwo coats of white wash all as specified and as directed directed by Engr-in-charge.Note:- (i) This item of work shall be executed upto a height of 25 Mtr height buildings/Structures/RCC OHTs.(ii) Scaffolding required to be done for executing the work above the normal heights as specified in SSR Pt-II shall be measured and paid separately under a separate item for the whole building/structure. 12 Demolition of brickwork and portions orderedto be dismantled built in cement mortar or cement lime mortar complete all as specified as directed. 13 M&L Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified as directed. 14 M&L for Rendering in CM 1:6, 10mm thick on fair faces of brick work or concrete surfaces all as specified and directed. 15 M&L for Rendering with WPC in CM 1:4, 15mm thick on othe thanfair faces of brick work or concrete surfaces all as specified and directed. Note : WPC shall be measured and paid separately 16 M & L Preparation of new plastered surfacesof walland applyingthree coats of white wash all as specified and as directed directed by Engr-in-charge. 17 Supply only Intergral waterproofing compound 18 Surface excavation not exc 30 cm and averaging 15 cm deep and getting out in Hard/Dense soil, all as specified. 19 M&L for 100mm thick broken stone or boulder,Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified. 20 M & L for Cement concrete in foundations, filling and mass concrete type D2 (1:4:8) 40 mm graded aggregatecomplete all as specified and directed. 21 Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; 22 Taking down shutters of any description n exc 1 sqm each 23 S & F Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified 24 S& F10047 Stairs (framed) including stringers, treades, landing,balusters, hand rails etc. . in cluding cleats, brackets, etc for Fe-290(Gde E 165).completeall as specified and directed. 25 Dismantling wrought iron or mild steel work of any description not otherwise provided forwindows grill etc. 26 M&L applying two coats of synthetic enamel paints on new steel surfaces over a coat of red oxide primer including surfacepreparation all as specified and directed.