Tender For Repair/ Replacement Of Electrical Distribution System And Certain E/M Items At Afs Deesa, deesa-Gujarat

Tender Notice

52269350
Tender For Repair/ Replacement Of Electrical Distribution System And Certain E/M Items At Afs Deesa
Tender
Indian
Gujarat
Deesa
28-11-2025

Tender Details

Tender For Repair/ Replacement Of Electrical Distribution System And Certain E/M Items At Afs Deesa; 1 Excavation in trenches not exceeding. 1.5m wideand not exceeding.1.5m in depthand getting out soft/loose soil for laying of cables etc complete all as specified and directed. 2 Returing, filling in excavated soil in trenches including spreading , Leveling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified and directed. 3 Removing surplus excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. 4 M&L for Bricks common burnt clay building bricks, sub-class ‘B’ designation of size 230mm x 115mm x 75 mm for cable protection complete all as specified and directed. 5 M&L for sand cushioning to PVC cable with using clean dry and natural river sand gently punning below/around cable complete all as specified and directed.Note: Thickness of sand shall be measured after punning. 6 S&F in trenches /fixed on walls/poles of passing through pipe, XLPE insulated armoured heavy duty LT U/G electric cable with aluminium conductor 1100 volts grade with suitable cable glands as required of following size complete all as specified and directed:- 7 10 Sqmm x 4 core 8 16 Sqmm x 4 core 9 25 Sqmm X 4.0 core 10 50 Sqmm X 3.5 core 11 95 Sqmm X 3.5 Core 12 M&Lin replacement for cross arms, bracing, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washer, welding, bending cold or hot, drilling of holes for bolts, in any shape or size and inclusive of one primer coat of redoxide, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed. 13 M&L in replacement of pin type insulator, porcelain, vitreous, white, brown, or green insulator including one galvanized mild steel spindle, two GI washers, and one GI nut 100 mm height , 65mm dia, for 1100 volts grade complete all as specified and directed. 14 M&L in replacement of shackle type insulator, including GI straps of size 31x5mm, 14mm dia washers, insulator bolts & nuts,height 100mm ,115mm dia, for 1100 volts grade complete all as specified and directed. 15 M&L for stringing existing OH line LT four wire system properly including replacement of binding wires complete all as specified and directed. 16 M&L for stringing existing OH line HT three wire system properly including replacement of binding wires complete all as specified and directed. 17 S&F in repairs ACSR conductor of any type and size straining properly on insulators and binding with aluminium binding wires, jumpers etc, including fixing to insulators on poles in span and tigtening with permissible sag complete all as specified and directed. 18 S&F in repairs MCCB ,TPN ,100 Amps, thermal magnetic release, breaking capacity 16KA complete all as specified and directed. 19 S&F in repairs MCCB ,TPN ,125 Amps, thermal magnetic release, breaking capacity 16KA complete all as specified and directed. 20 S&F in repairs MCCB ,TPN ,160 Amps, thermal magnetic release, breaking capacity 35KA complete all as specified and directed. 21 Supply and fix in repairs expulsion fuse single pole 11000 volts above 25 Amp to 50 Amps complete all as specified and directed. 22 Supply and fix in repairs stay assembly comprising stay bow 14 mm dia and 40 cm long, stay rod 20 mm dia and 1.8 M long threaded ends with nuts, stay plate and loop insulator complete all as specified and directed and shown on electric plate No. 1 complete all as specified and directed.Note: All excavation, earth work and concrete work shall be measured and paid separately under respective item of BOQ.. 23 S&F Anticlimbing device comprising 2.24 mm dia galvanized steel 2- strand barbed wire with 2 mm dia barbed wrapped spirally round poles, to a length of 0.5 m to 1m clamped and properly secured or as ordered complete all as specified and directed.. 24 Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed one twin core cable flat or circular size 6 sqmm complete all as specified and directed 25 Supply and fix GI tubing light grade for protection of cable at wall/trench of size 40mm dia bore complete all as specified and directed. 26 Dismantling old pipes and Supply and fix GI tubing light grade for protectin of LT cable of size 50 mm dia bore complete all as specified and directed. 27 S&F steel tubular swaged complete including cast iron plate base plate, final plug, bolts, nuts and screws as specified type 410 SP-31 of length 9 mtrincluding taking down old unserviceable existing pole and demolition of concrete etc complete all as specified and directed.Note: All excavation, earth work and concrete work shall be measured and paid separately under respective item of BOQ. 28 Supply and fix repairs danger notice plate of 1.6 mm thickmild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps,bolts, and nuts of approved size for LT 20x 15 cm in size complete all as specified and directed. 29 Supply and fix repairs danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, blts, and nuts of approved size for HT 25x 20 cm in size complete all as specified and directed. 30 M&L for providing cement concrete 1:3:6 Mix, type C2 (using 40 mm graded stone aggregate) for foundation of poles/struts/stay etc complete all as specified and directed. 31 M&L cement concrete 1:3:6 Mix, type C1 (using 20 mm graded stone aggregates) for pedestal of poles, all including necessary form work, fair finishing to the exposed surfaces using extra cement complete all as specified and directed. 32 Demolition of old broken PCC coping on existingpole and M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping of poles including necessary form work complete all as specified and directed. 33 Maintenance and servicing of 40 KVA DG set of any makeDiesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine B check of the enginecheck complete for smooth functioning all as per manufacturers instructions and as directed 34 NOTES:(i) Control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall exclusive of servicing/ maintenance of the above said fittings 35 (ii) B check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. Servicing of DG Set along with connected Alternator and Panel Board including items covered in A Check of the Engine shall also be carried out in that month as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG set for a period of 30 days from the date of service and shall also attend all the maintenance works as and when required in that period except in case of Major repairs (iii) Spare parts, engine oil and radiator coolant oil required for replacement during the maintenance period shall be measured and paid separately . 36 (iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item,contractor to be provided fuel filter, oil filter, water filter,top head gaskets,fuel pipes, battery terminal, battery lead and distilled water.(v) List of checks to be carried out under B check is attached as Appendix B to the Particular specifications. 37 15. SERVICE DONE ‘B’ CHECK As per items in Sch ‘A’15.1. Check Engine Oil Level15.2. Check Oil Bath Cleaner Oil Level15.3. Drain Sediment From Fuel Tanks15.4. Clean Pre Cleaner Dust Pen15.5. Check Air Cleaner Rostnction15.6. Clean/Change Air Cleaner Element15.7. Change Oil Bath Cleaner Oil15.8. Check Coolant Level15.9. Change Engine Oil15.10. Change Engine Fuel Flow Oil Filter15.11. Change By Pass Filter 38 15.12. Record Oil Presure15.13. Check Battery Voltage and Water Level and Apply Jelly on terminates.15.14. Check and Tight all Bilts and Nuts of Engine and Altemator.15.15. Check all AVM Pads15.16. Check Diaphragm Compling15.17. Check Tappet Clearance15.18. Repalce the Valve Door Gasket15.19. Check Throltle Linkage15.20. Change Full Filter15.21. Clean Fuel Tank Breather15.22. Check erehuft for leakage15.23. Check Carbon brush & Commection in Alternator15.24. Record RPM, Voltage, AMPS & H215.25. Record Oil Presure.15.26. Clean / Change Crank Case Breather15.27. Check Air Piping15.28. Clean Oil Both Air Cleaner Tray Screen15.29. Change Water Filter15.30. Check / Adjust Belts15.31. Adjust injectors and Valves15.32. Clean Oil Bath Air Cleaner 39 15.33. Check Fan Hub / Air Blower Hub and Water Pump15.34. Clean and Calibrate Injector Replaca Fuel Pump Filter Screen and Magnet15.35. Check Fuel Pump Calibration15.36. Clean Turbocharger15.37. Check Turbocharger Bearing Clearance15.38. Tighten Manifold Nuts or Copscrews15.39. Rebuild or Replace Water Pump15.40. Replace Hose15.41. Clean Electrical Connections15.42. Check Safety Controls15.43. Clean Cooling System / Rediator Assy.15.44. Clean Engine and Alternator Assy.Note : If any addition requirement for ‘B’ Check as directed by Engineer-in-Charge 40 M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected to and including galvanised MS Strip 32 x 6 mm as earthing lead by means of bolts, nuts check nuts and washers etc made of GI and connected to earthing test point al as shown inelectric pate No 3 of SSR indicated and testing on completion including Excavation and earth work in any rype of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50 mm thick in cement concrete (1;2:4) type B-1 rain forced with welded steel wire fabric (AMP)weight not less than 4 kg/ sqm, funnel with GI watering pipe of 20 mm bore medium grade, wire mess and lugs, GI protection pipe of 40 mm bore lightgrade 7.5 m long test point etc complete all as specified and directed. 41 Supply and fixing following filters of DG Set capacity 20 KVA to 62.5 KVA complete all as specified and directed:- 42 Air filter Primary 43 Lub Oil filter 44 Fuel filter 45 Supply and fixing / filling following items for DG Set complete all as specified and directed:- 46 Battery terminal heavy duty of brass. 47 Distilled water (In 1 ltr bottel) 48 Coolant for radiator. 49 Engine oil SAE 20W-40W. Make : Servo/ Castrol/VOLVOLINE/ IOC/HP 50 S&F in repair of bracket with clamp of 25 mm dia for fixing street light fitting made out of GI pipe light grade including bending to shape of length 1.5 m complete all as specified and directed. 51 S&F Junction box 290x200x130 mm polycarbonate/ ABS hinged enclosure box IP-66/67 for cable in/out of street light LT cable, out door type, testing and commissioning with locking arrangements fixed on poles 4 poles 100 Amp connector/ terminal assembly with nut bolt and washer, including MCB SP 6 A, 240V, 10 KA -01 Nos for connecting suitable size of XLPE UG cable complete all as specified and directed. Make Hansel / IDIS india /Naptune 52 Disconnecting / dismantling and removing unserviceable power contactor of any description from panel and supply, fixing, connecting and testing in existing panel new power contactor type ML3of capacity 40 Amps with AC3 rating on 415 Volts AC supply having2NO+2NC auxiliary contacts complete all as specified and directed. Make : L&T cat part No SS90721 or equivalent of make Legrand / BCH/C & S Electric 53 S&F cylinderical type power factor correction MPPheavy duty capacitor 5 to 30 KVAR complete all as specified and directed. 54 M&L for repair existing size GI/CPVC/PPR pipe line against leakages including repalcement of unserviceable Jointing materials, threading, nipples, etc complete all as specfied and directed. 55 Supply & laying medium grade GI pipe in trenches, wall / plinth medium grade with all GI fitting including taking down old unserviceable pipe from existing complete all as specified of following sizes :- 56 15 mm dia bore. 57 20 mm dia bore. 58 25 mm dia bore. 59 50 mm dia bore. 60 Supply and fix in repair Gun metal gate valve with iron wheel head screwed bothends foriron pipeincluding taking down old unserviceable valve complete all as specfied of folowing sizes :- 61 15 mm dia size. 62 20 mm dia size. 63 25 mm dia size. 64 50 mm dia bore. 65 Supply and fix in repair Ball valve CPVC of outer diameter 25 mm complete all as specfied and directed. 66 Supply and fix in repair fully automatic star delta starter complete with Power contactor , Overload relay, timer single phase preventor etcupto50 HP capacity complete all as specified and directed. 67 Labour only for Disconnecting the existing non functional submersible pump set from electric supply from panel, dismantling existing CI bend from non return valve, removing and lifting out submersible pump set of any description and capacity & in any position, along with existing column pipe 50mm dia and existing submersible cable of any size from the bore well (approximately upto 300 Mtr depth of pump set from GL) and staking the pump and column pipes near by the bore well at MES store complete all as specified and directed. NOTE: - ( i ) Contractor shall take proper precautions while lifting out and removing pump set from bore well so as to avoid any damage to column pipe and submersible cable. All necessary T&P and equipments required for lifting out pump set etc. shall be arranged by the contractor at his own cost. 68 Supply only common salt for water softner installation complete all as specified and directed. 69 Supply & provide Aquafit (Calcium hypo chlorite)65%-70% chlorine content (Calcium based granular desinfectant for water treatment plants much more stable than chlorine gas & stronger than bleaching powder and sodium hypo chlorite packed in 45 Kg drum complete all as specified and directed. Make : Auafit & Equivalent. 70 M & L for carrying out water testing ( Biological& Chemical test) for various locations including collection of the sample from the various site (like pump house, Bore well etc) and testing in authorised NABL lab complete all as specified and directed. 71 Supply installation, testing and commissioning of Chlorine Dozing Pump operating at 230 Volt AC, 50 Hz with PVC suction/ Delivery tubing of not less than 4mm dia, 3m length, suction filter cum foot valve, injection/ back pressure assembly inlcuding complete working sodium hypochloride dose rate minimum level upto 0-10 LPH/ 3mg/lit, NAOCL concentration @10%, NAOCL PPM @ 100000 mg/lit, dosing flow rate minimum level upto 5.625 LPH complete all as specified and directed. Make : M/s Satya Sai Aqua Pura services/ E doze/ Grundfos pumps india/ M/s Optimus Enviropro Pvt Ltd/ SIMA/ SEEPL/ M/s Pristine water. 72 M & L for annual servcing of split AC of capacity 1.5/2.0 TR by disconnecting electric connection from its stabilizer or its electric supply board and removing the front cover of indoor split unit of AC and cleaning it with pressurised water and nylon brush, refixing the front cover of indoor unit. including removing the front cover of outdoor unit with polythene/plastic cover so that water shall not be entered in the motor while cleaning the outdoor unit and cleaning the condensing coilunit with pressurised water then applying one coat of descaling solution and cleaning with nylon brush.Cleaning of condensing coil of outdoor unit shall be properly carried out without damaging other parts, checking for leakages incl bracing and addl copper tubes repalcement as reqired upto 0.5 mtr length and making serviceable electrical connection of DB, stabiliser, wiring of AC and replacing unservicable metal/plastic plug tao as required at site, as per site condition and tightening of loose connection complete all as specified and directed. 73 Material and labour for flushing out system for leak testing of cooling coils attached with indoor and outdoor unit of split air conditioner using CO2/ nitrogen Gas, arrest of leakage with brazing of copper pipe including gas charging with using refrigerant R-22/32, oil charging complete in compressor window type AC/ Split type AC cap.1.5/2 Ton all as directed & with entire satisfaction of Engineer-in-Charge.and retest again for rectification leakage on load complete all as specified and directed. 74 Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA complete all as specified and directed. 75 Checking of refrigirent pressure ofsplit AC system by using pressure gauge and topping up the refrigerant gas to obtain pressure for R22 requires up to 60 to 65 PSI, R32 requires up to 110 to 120 PSI, and R410A requires up to 110 to 120 PSI and obtain desire level of cooling as per user satisfaction complete all as specified and directed:- 76 R-22 77 R-32 78 R-410a 79 S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps complete all as specified and directed.Make: Legrand, Schnider, IndoAsian 80 Taking down carefully old/unserviceable aluminium/ copper point wiring (light, fan , power, socket etc.) complete including removing unserviceable fittings such as switches, ceiling roses pendants, sockets, lamps holder, brackets, fluorescent tube fitting any type, boards fan, regulators etc. and making good to the disturbed surfaces of wall/floor, etc complete all as specified and directed. 81 M & L for point wiring with copper conductor cable multistrand, PVC sheathed 1.5 Sqmm size for one light point or bell point controlled by one switch including one run of 1.5 Sqmm multistrand PVC sheathed copper conductor cable for earth continuity in and including PVC casing and caping of approved size and qualityISI marked,including all other required accessories as specified in Preamble 1(a) to (q) of section 19 of SSR Part-II under heading Point wiring.fixed on walls/ceiling including sunk cast iron or PVC terminal boxes for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover inclding arrangements for modular /regular fittings acessories complete all as specified anddirected. 82 One light point controlled by one, one way switch. 83 One fan point controlledby one, one way switch and regulator. 84 One 3 pin 5 Amps socket outlet on same board with other switch. 85 One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size. 86 All as per item No 51 above but for power point 3 pin switch socket 15 Amp with PVC insulated copper conductor cable multistrand unsheathed 2.5 Sqmm on independent board including one run of2.5 Sqmm multistrand PVCsheathed copper conductor cable for earth continuity in and including PVC casing and caping of appropriate size and best quality ISI marked, including all other required accessories as specified in preamble 1(a) to (q) of Section-19 of SSR Part-II under heading Point wiringfixed on wall including sunk cast iron or PVC terminal boxes for mounting fittings like switch, sockets etc covered with 3.00 mm thick plastic laminated sheet top cover all as specified and as directed. 87 S&F modular switch piano one way 6 Amps(ISI marked ) complete all as specified and directed. 88 S&F switch modular socket combination 5 Amps , 3 pin and 2 pin flush type (ISI marked) complete all as specified and directed. 89 S&Fof switch piano one way 5 Amps flush type (ISI marked ) complete all as specified and directed. 90 S&Fof switch piano one way 15 Amps flush type (ISI marked ) complete all as specified and directed. 91 S&Fof socket outlet 5 Amps , 3 pin and 2 pin flush type (ISI marked) complete all as specified and directed. 92 S&Fof socket 15 Amp, 3 pin and 2 pin flush type (ISI marked) complete all as specified and directed. 93 S&Fof switch socket combination 5 Amps , 3 pin and 2 pin flush type (ISI marked) complete all as specified and directed. 94 S&F in repairs of switch socket combination 5/15 Amp, 3pin and 2 pin flush type ISI marked complete all as specified and directed. 95 S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and directed. 96 Supply and fix ceiling rose 2 or 3 terminals, PVC/ Polycarbonate, ISI Marked complete all as specified and directed. 97 S&F in repairs of switch modular one module 10 Amps flush type (ISI marked ) complete all as specified and directed. 98 S&F in repairs of switch modular one module 15 Amps flush type (ISI marked ) complete all as specified and directed. 99 S&F in repairs of socket outlet modular two module 5 Amps , 3 pin and 2 pin (ISI marked) complete all as specified and directed. 100 S&F in repairs of socket modular two module 15 Amp, 3pin and 2 pin (ISI marked) complete all as specified and directed. 101 S&F stepped type modular fan regulator, 120W-2 MODULE Complete all as specified and directed. 102 Supply and fixing in repair straight/Angle bulb holder PVC body incl 20 W LED lamp complete all as specified and directed. 103 Supply and fixing repair in Stepped/socket type electronic fan regulator heavy duty type A/C 240 V complete all as specified and directed. 104 S&F in repair MCB DB SPN double door, 230 volts ,8 way complete with bus bar 200 amps capacity and neutral links all as specified and directed. 105 S&F in repair MCB SPsingle pole, 5 to 30 Amps, 10 KA, 240 volts ISI Marked complete all as specified and directed. 106 S&F in repair MCB SPN upto63 Amps, 10 KA,240 volts ISI Marked complete all as specified and directed. 107 M & L forsub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping / PVC Conduitincluding accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed including taking down existin submain wiring complete all as specified and directed.Note: Two run of main wire, one run of earth wire and one run of conduit/ casing caping shall be measured as one unit. 108 M & L forsub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping including accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, PVC insulated & unsheathed including taking down existin submain wiring complete all as specified and directed.Note: Two run of main wire, one run of earth wire and one run of conduit/ casing caping shall be measured as one unit. 109 Supply and Fix LED Tubelight fitting , ENERGY Efficient 20 Watt 2000 lumen bright lightcomplete all as specified and directed. 110 Supply and FixLED Tubelight fitting, ENERGY Efficient 10 Watt 2000 lumen bright lightcomplete all as specified and directed. 111 Supply and fixing capacitor of 2.5 MFD of ISI marked complete all as specified and directed.Make: Epcos, Havells. 112 M & L forrewinding of ceiling fans 1200/1400mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc 6 month waranty period shall given by the dealer/contractor after repair, complete as reassembling taking down and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed. Note:- Contractor shall make the suitable arrangement at Darjipura (MES) premises to replacing of accessories, testing upto the satisfactory level in front of concerned E/M in charge without fail. 113 Supply and fix in replacement LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple opticscomplete with IP 65/66 protection complete all as specified and directed. 114 supply and fix in replacement LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple opticscomplete with IP 65/66 protection complete all as specified and directed. 115 supply and fix in replacement LED Gate Light 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple opticscomplete with IP 65/66 protection complete all as specified and directed. 116 Supply and fixing ceiling fans complete with blades, down rods, electronic remote regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. 117 Supply and fixing Exhaust fan complete with accessories, 230 V, 300 mm sweep alongwith louvers complete all as specified and directed. 118 Comprehensive maintenance of street light comprising of 45/70/144 watt HPSV/HPMV/LED fitting of any make, model fitted on the pole at any height with any type of fixing arrangement by replacing the igniter, ballast, holder, lamp, flexible wire, lightening the required connections , clamps etc complete all as specified and directed. 119 M&L for preparation of existing old painted surface of any description such as LT/HT steel tubular/PCC electric pole/struts of any height and painted complete including cross arms bracing clamps etc with one coat of aluminium paint and in white/blue alternative strips of 30 cm width each all around the pole up 1.5 Mheight from ground level/top of PCC copping including writing MES, LT/HT feeder No and pole No (in capital letters) stencil cut decorative manner on pole using fluorescent paint pre and post monson complete all as specified and directed. 120 M&L for site clearance of Electrical installation by removing of shrubs, vegetation cutting of grass, bush, wood trees not exceeding 30 mm dia branches and roots and leveling of area and removal of same outside MD land as per direction of site / Engr-in-charge complete all as specified and directed. 121 S&F Flex sheet Glow sign Board etc of size 1.8 mtr x 1.2 mtr x 20 cm made out of 1 mmGI sheet thick including LED tube light and connecting cable for glow, flex sheet is computirsed printed location of instalation and other details all as specified and as directed by Engineer in Charge. 122 Supply, fixing and fabrication and testing of Timer switch, 110 - 240 VAC 1 Phase - 2W 2 C/O , Base/Din 50 ON/OFF Each, Make L&T Astro or equivalent incl PVC enclosure with fixing materials on street light pole complete all as specified and directed. 123 Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete, with fixing materials complete all as specified and directed. 124 M & L for Framed work as in doors or gates of angle (40X40X5)or other section with gasket plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete with locking arrangement all as specified and directed.(Under ground Sump).Note: Preparation of steel surfaces and application of two coats of synthetic enamelled paint over and including of red oxide primer deemed to be included in quoted rates. 125 S&F Mild steel, plain, black sheet, 2 mm thick as in wall cladding,steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up and welding handle for lifting, mitred angles, etc. as required complete all as specified and directed.Note: Preparation of steel surfaces and application of two coats of synthetic enamelled paint over and including of red oxide primer deemed to be included in quoted rates.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 25 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail