| 1 | M & L for carefully dismantling steel poles/struts, any size for reusd or taking credit complete all as specified and directed. |
| 2 | Supply and errecting steel tubular pole in replacement ofRCC/steelpoles with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) duly painted internally complete and externally painted with two coat of aluminium paint, Incl writing of MES pole NO complete all as specified and directed.Note: Earth work /excavation / PCC shall be measured and paid separately. |
| 3 | S&F in replacement of mounting bracket single arm forming Cap type having an interior angle of 120 degree made out of GI pipe Med grade suitable dia for fixing to street light fittings on the poles not less than 1.5 meter long duly painted with aluminium paint two coats complete all as specified and directed.. |
| 4 | S&F in replacement of mounting bracket double arm forming Cap type having an interior angle of 120 degree made out of GI pipe Med grade suitable dia for fixing to street light fittings on the poles not less than 1.5 meter long duly painted with aluminium paint two coats complete all as specified and directed.. |
| 5 | S&F in replacement PVC wire 1.5 sqmm 3 Core PVC insulatedcable copper drawn through internally from looping box to street light fitting terminal incl all electrical connection complete all as specified and directed. |
| 6 | S&F in replacement of looping box (enclosures) of size 300 x 250 x 150 mm made of PVC comprising of 01 Nosprocelin type 4 pole connector (size 100 mm) suitable rating fixed on porcelain insulators, earthing terminal and one MCB SP 6 Amp including MS bracket, nut an bolts complete all as specified and directed. |
| 7 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc. and getting out soft/ loose soil complete all as specified and directed. |
| 8 | Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25cm complete all as specified and directed. |
| 9 | Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 10 | Supply and laying/fixing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (H/D) earthed cable aluminium conductor, 1100 volts grade with standed complete all as specified and directed for 16 sq. mm, 4 core nominal cross section in service connections incl taking down old cable complete all as specified and directed |
| 11 | M & L for boring of holes up to 50 mm dia under road pavement, hard standing, etc by trench- less technology using ultra sound technique/manully complete all as directed by Engineer-in- charge. |
| 12 | M & L PCC 1:3:6 type C2 using 40 mm graded stone aggregate in foundation of pole complete all as specified and directed. |
| 13 | M & L PCC 1:3:6 type C1 using 20 mm graded stone aggregate in copingof pole including necessary form work complete all as specified and directed. |
| 14 | S&F in replacement automatic Switch complete pole mounted enclosure consisting of MCBs, Power Contactor and SMC Enclosure conforming to IP 54) for encasing full 1- phase circuit board along with automatic Switch-01,Model No SWADEEP – 02EC 3kW1P or techno commercially equivalent as approved by GE (for 3-5kW load equally distributed over 1-phase) incl all electrical connection complete all as specified and directed by Engr-in-charge. |
| 15 | Supply and laying of DWC HDPE pipe of SN4 category conforming to IS 14930 part I and II including accessories like HDPE snap fit coupler with neaoprene \"O\" rong ofsize 38 mm inner dia complete all as specified and directed. |
| 16 | M&L forearthing complete with galvanized steel earth plate electrode 600x600x6mm thick electrode, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to 4 mm dia galvanized earth wire by means ofbolts, nuts, check-nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 (duly protected with 15 mm dia light grade GI pipe upto 7.5m from the earth plate) and connected to GI steel earth plate including charcoal, dust, common salt, necessary excavation in soft/loose soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m from the starting point, watering pipe 20 mm bore GI tube of light grade treated with 1 No PGI funnel, pit of PCC 1:2:4 type B-1/ RCC1:2:4 type B-1, pit cover 75 mm thick reinforced with 6 mm dia bars @ 75 mm c/c both ways and with MS handle 12 mm diaconnected to earth test point including testing complete all as specified and directed. |
| 17 | Supply and fixing in replacement of 90 watt LED street light fitting230 V, AC outdoor type,CCT 5700K with high pressure die cast hosing,toughened glass and secondery lens optics with IP 66 ingress protectioneffiency 120 lm/watt complete all as specified and directed. |
| 18 | Errecting/fixing only serviceable steel tubular pole against item no 1 (serviceable only)complete and externally painted with two coat of aluminium paint, Incl writing of MES pole NO complete all as specified and directed.Note: Earth work /excavation / PCC /looping box/ etc shall be measured and paid separately. |
| 19 | Demolition of cement Concrete of any description and in any position not otherwise specifically provided (below or above ground level) complete all as specified and directed. |
| 20 | M&L including taking down for point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) through and including 20X12 mm PVC casing and capping and its accessories, cadmium screws and including 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and MS boxes made of 16 gauge MS sheet concealed type on walls cover 3mm thick for housing complete all as specified and directed for the following :-(a) One light/fan point controlled by one onway switch complete all as specified and directed. |
| 21 | All as per item No 20 here in before but One socket outlet 05 Amps on the same board complete all as specified and directed. |
| 22 | All as per item No 20 here in before but One socket outlet 05 Amps on independent board complete all as specified and directed. |
| 23 | All as per item No 20 here in before but 3 pin socket outlet 15 amps sockets on independent board with 2.5 sqmm multistranded copper PVC insulated cable. |
| 24 | S&F in repair Switch piano, single pole one way 5 Amps 240 volt capacity flush type complete all as specified and directed. |
| 25 | S&F in repair3 pin 5 Amps Socket outlet , flush type complete all as specified and directed. |
| 26 | S&F in repair 5 pin, 5 Amps switch & socket combination flush type multipurpose3 pin, 5 Amp flush type universal including PVC mounting box complete all as specified and directed. |
| 27 | Supply and fix in repair Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal including PVC mounting box complete all as specified and directed. |
| 28 | S&F in repair fan regulator electronic step type 230 volts switch /socket type suitable for any type of ceiling fan sweep complete all as specified and directed. |
| 29 | S& F ceiling rose, 5 Amps surface type 240 volts bakelite three terminal complete all as specified and directed. |
| 30 | S&F in replacement 8 way SPN sheet metal enclosures for flush/surface mounting distribution board double door, 240 volts factory made and tested complete, suitable for mounting MCBs with 200 Amps rated bus bar, cable lugs complete all as specified and directed. |
| 31 | S&F in replacement 4 way SPN sheet metal enclosures for flush/surface mounting distribution board double door, 240 volts factory made and tested complete, suitable for mounting MCBs with 200 Amps rated bus bar, cable lugs complete all as specified and directed. |
| 32 | Supply and fixing in replacement SP 5 To 32 AMP rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) complete all as specified and directed. |
| 33 | All as per item No 33 here in before but SPN 40 to 63 AMP complete all as specified and directed. |
| 34 | S & F in replacement of LED batten fitting alongwith removable LED Tube 20W, 230 Volt, 6000K, wall /ceiling mounted ,LED battenfixed by means of bolts,ABS rotor suitable for single side connections. LED rod having glass material complete haivng lumen efficacy minimum 100 lm/w,CCT 6500 K, powered by integral constant current driver suitable for 240 V AC with all accessories internallly prewired including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 35 | Supply and fixing replacement LED light 35 watt 230 VAC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 36 | Supply and fixing in replacement of 90 watt LED street light fitting230 V, AC outdoor type,CCT 5700K with high pressure die cast hosing,toughened glass and secondery lens optics with IP 66 ingress protectioneffiency 120 lm/watt complete all as specified and directed. |
| 37 | All as per item No 37 here in before but 70 watt capacity complete all as specified and directed. |
| 38 | S&F in replacement PVC wire 2.5 sqmm 3 Core PVC insulated rounded industrial cable copper drawn through internally from looping box to street light fitting terminal incl all electrical connection complete all as specified and directed. |
| 39 | S&F in replacement PVC wire 1.5 sqmm 3 Core PVC insulated rounded industrial cable copper drawn through internally from looping box to street light fitting terminal incl all electrical connection complete all as specified and directed. |
| 40 | S&F in replacement for sub main wiring of two run with 04 Sqmm single core PVC insulated, FRLS,flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC casing caping andone run of same sizecopper cable as earth continuity conductor in green color complete all as specified and directed. Note- Two runs of single core cable with one run of earth continuity cable including PVC casing-n-capping and its accessories will be measured and paid as one unit |
| 41 | S&F in replacement of looping box (enclosures) of size 300 x 250 x 150 mm made of PVC comprising of 02 Nosbus bar 100 Amps rating fixed on porcelain insulators, earthing terminal and one MCB SP 6 Amp including MS bracket, nut an bolts complete all as specified and directed. |
| 42 | M&L for earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6 mm burried directly in ground level with top edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanised iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No.3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock,PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforce with welded steel wire babric (APM) weight not less than 4 Kg/Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and directed. |
| 43 | Supply of high power, auto-swivel LED search light, long rang 1000 meter, multi fuctional.2 x300 watt, multicircuit LED Efficacy > 140 Im/w, CCT 5500K LM6 housing with heat sink, round in shape dia >400mm, operating voltage 230 v, 50hz, PF>0 95. THD<10% CCT 550OK. CRI> 70, Optics used- PMMA/PC lens, narrow bean 7 degree, average lux level at 10meter > 9000 with circle of approx 1 meter, toughened clear glass with silicon gasket, over volt / under volt & short circuit protected confirming to LM79, LM80, IK07, IP66, lux report, Type tested as per IS 10322, IS. 15885. and B.I.S. certified. This search light should be installed on rotating disc of horizontal Plane and tiltable upto 45 degree. A separate wall mounted wire control panel (1 to 10rpm), Auto/ manual, reverse / forward, up / down through the various push buttons for operation remotely. The revolving mechanism is fully covered with weather & rust proof die cast fiber box with maintenance window & side doors, provision of foundation holes at bottom for proper installation complete all as specified and directed.Model No: MRSL-LRFLL-25PC302, Make: KALIN or techno commercially equivalent as approved by GE. |