| 1 | Material & Labour for taking out old unsv cable of any size, GI pipe protection, bricks including separating serviceable brics & set aside for reuse andremoving unsrviceable bricks complete all as specified and as directed. |
| 2 | Supply and laying or passing through pipe XLPE cable insulated galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 70 sqmm 3.5core complete all as specified and directed. (Make : KEI/Havells/Gloster/Polycab) |
| 3 | All as per srl item No 2 butsize 50 Sqmm 3.5 core |
| 4 | All as per srl item No 2 butsize 35 Sqmm 3.5 core |
| 5 | All as per srl item No 2 butsize 25 Sqmm 4 core |
| 6 | All as per srl item No 2 butsize 16 Sqmm 4 core |
| 7 | All as per srl item No 2 butsize 10 Sqmm 2 core |
| 8 | Re-laying only LT cable any sizes obtained from item No 01 with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. |
| 9 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type of soil complete all as specified and directed. |
| 10 | Returning, filling in including, spreading, levilling,watering and well ramming in layers not exe 25 cm thick each complete all as specified and directed. |
| 11 | Removing excavated material to a distence not exc 50m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. |
| 12 | Material and labour for Sand cushioning to under ground cable providing with a layer 8cm thick before laying the cable and 15 cm thick after laying the cable. Complete all as specified in clause 19.75 of SSR 2009 Part-I (Specifications) complete all as specified and directed. |
| 13 | Supply and laying for sub class B brick of size 225mm x 115mm x 65mm for protaction of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed. |
| 14 | Reifixing of existing bricks/ cable cover any type of good condition after the cleaning complete all as per specified and directed |
| 15 | Supply and fix GI Tubing (light) grade with all fittings, laid in trenches, or fixed along with walls/poles including brackets, nuts & bolts etc. bore of pipe 80 mm complete all as specified and directed. |
| 16 | Supply and fix GI Tubing (light) grade with all fittings, laid in trenches, or fixed along with walls/poles including brackets, nuts & bolts etc. bore of pipe 50 mm complete all as specified and directed. |
| 17 | Material and labour for repair to any type of existing LT Panel board(indoor/ outdoor) with cutting necessary rusted portion of MS Sheet Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with riveted, bolted or welded attachment providing MS Sheet of 2mm/3/15 mm of existing size and hinges to broken doors etc fixed with welding complete all as directed. |
| 18 | Material and labour for cleaning debried around of LT panel / feeder piller box. cleaning the internal and external surfaces bus bar, terminal blocks, insulations using dry cloath, vaccum cleaner and blower. Check the tightenes of all electricals cable terminals, bus bar connection and earth connection. Check the serviceability of control switches, indicators, seceloter switches, apply lubricents to hings, locks and moving parts. Check the panel enclosure and gasket are sealed properly and preparation of existing surface of feeder piller box and panel including scraping of old paint and apply two coats of synthetic paint with spray gun of approved shade to ensure a smooth and uniform finish complete all as specified and directed. Note: 1. An electrician is required for checking all the electrical items. |
| 19 | Supply, installation, commissioning and testingLT outdoor panel cubicle type of minimum size 1.2 Mtr (height) x 1.0 Mtr (breath) x 0.5 Mtr (depth) ,CPRI approved factory made, weather, dust & vermin proof outdoor cubical compartmental type, Doubledoor, front and back side openable, with providing rubber / PVC gasket of suitable size all sides of door, with Aluminium busbar chamber consisting of 4 nos of bus bar of capacity 400 Amps of aluminium bus bar 415 volts wrapped with PVC tape / sleeves with maintained the colour code and Aluminium strip busbar of suitable sizeto MCCB input and MCCB output of suitable length for connection of cable from main busbar, including digital multi function meter and Indicating lamps LED type ( R Y B) including wiring with suitable rated PVC insulated copper conductor wire, made out of 3.15 mm thick mild steel CRCAsheet with 50 x 50 x 6 mm size angle iron supporting frame andMC 75 channel base including applying two coats of Powder coated paint over exposed external & internal surfaces suitable for 3 phase 4 wire system 415 / 440 volts grade including complete connections and embedded in PCC foundation of size as required in cement mortar 1:4:8 and plastering the same in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.(a) MCCB 4 pole 200 Amps, 50 Hz of breaking capacity 36 KA -01 No(a) Onload changeover 200 Amps four pole - 01 No(b) MCCB 4 pole 100 Amps, 50 Hz of breaking capacity 25 KA -02 No(b) MCCB 4 pole 63 AMps,50Hz of breaking capacity 25 KA - 02 Nos (c) MCB SPN 32 AMps,50Hz- 02 Nos(d) CT operated digital Multi function meter - 01 Nos (e) LED type Indicating lamp (set of 3 ) - 01 set(f) Necessary wiring including material, fixing and connection to existing load. |
| 20 | Supply and fixing MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity, rating 200 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian) |
| 21 | Supply and fixing MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 160 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian) |
| 22 | Supply and fixing MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 27 KA breaking capacity, rating 100 / 63 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian) |
| 23 | Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 10-16 Sqmm, 3.5/4.0 core, complete all as specified and as directed. MAKE: 3M/RAYCHEM/DENSONS |
| 24 | Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 25-50 sqmm 3.5/4.0 core cable complete all as specified and as directed. Make : 3M/RAYCHEM/DENSONS |
| 25 | Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 70-150 sqmm 3.5/4.0 core cable complete all as specified and as directed. MAKE: 3M/RAYCHEM/DENSONS |
| 26 | Supply, fixing and testing of heat shrink LT cable indoor/out door jointing kit suitable for 1100 volts grade 10-16 sqmm 3.5/4.0 core cable complete all as specified and as directed. MAKE: 3M/RAYCHEM/DENSONS |
| 27 | Supply, fixing and testing of heat shrink LT cable indoor/out door jointing kit suitable for 1100 volts grade 25-50sqmm 3.5/4.0 core cable complete all as specified and as directed. MAKE: 3M/RAYCHEM/DENSONS |
| 28 | Supply, fixing and testing of heat shrink LT cable indoor/out door jointing kit suitable for 1100 volts grade 70-150 sqmm 3.5/4.0 core cable complete all as specified and as directed. MAKE : 3M/RAYCHEM/DENSONS |