Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #52265808

Tender For Repairs To Lt Distribution System, Ug Cable, Panels, Mccbs And Other Misc Works At Afs Pukpui, Lunglei Under Age (I) (Af) Kumbhirgram

Issued by Statutory Bodies & Commissions/Committees · lunglei, Assam
Tender Value
9.50 Lakhs
Estimated cost
Bid Submission
08 Dec 2025
0 days left
EMD
19000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
lunglei → Assam
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Repairs To Lt Distribution System, Ug Cable, Panels, Mccbs And Other Misc Works At Afs Pukpui, Lunglei Under Age (I) (Af) Kumbhirgram

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-Dec-2025 Corrigendum No 1 Date 08-Dec-2025
2 24-Nov-2025 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-Dec-2025

BOQ

Name of Work: REPAIRS TO LT DISTRIBUTION SYSTEM, UG CABLE, PANELS, MCCBs AND OTHER MISC WORKS AT AFS PUKPUI, LUNGLEI UNDER AGE (I) (AF) KUMBHIRGRAM.
Sl. No. Item Description
1Material & Labour for taking out old unsv cable of any size, GI pipe protection, bricks including separating serviceable brics & set aside for reuse andremoving unsrviceable bricks complete all as specified and as directed.
2Supply and laying or passing through pipe XLPE cable insulated galvanised steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 70 sqmm 3.5core complete all as specified and directed. (Make : KEI/Havells/Gloster/Polycab)
3All as per srl item No 2 butsize 50 Sqmm 3.5 core
4All as per srl item No 2 butsize 35 Sqmm 3.5 core
5All as per srl item No 2 butsize 25 Sqmm 4 core
6All as per srl item No 2 butsize 16 Sqmm 4 core
7All as per srl item No 2 butsize 10 Sqmm 2 core
8Re-laying only LT cable any sizes obtained from item No 01 with all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed.
9Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth and getting out in any type of soil complete all as specified and directed.
10Returning, filling in including, spreading, levilling,watering and well ramming in layers not exe 25 cm thick each complete all as specified and directed.
11Removing excavated material to a distence not exc 50m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
12Material and labour for Sand cushioning to under ground cable providing with a layer 8cm thick before laying the cable and 15 cm thick after laying the cable. Complete all as specified in clause 19.75 of SSR 2009 Part-I (Specifications) complete all as specified and directed.
13Supply and laying for sub class B brick of size 225mm x 115mm x 65mm for protaction of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
14Reifixing of existing bricks/ cable cover any type of good condition after the cleaning complete all as per specified and directed
15Supply and fix GI Tubing (light) grade with all fittings, laid in trenches, or fixed along with walls/poles including brackets, nuts & bolts etc. bore of pipe 80 mm complete all as specified and directed.
16Supply and fix GI Tubing (light) grade with all fittings, laid in trenches, or fixed along with walls/poles including brackets, nuts & bolts etc. bore of pipe 50 mm complete all as specified and directed.
17Material and labour for repair to any type of existing LT Panel board(indoor/ outdoor) with cutting necessary rusted portion of MS Sheet Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment with riveted, bolted or welded attachment providing MS Sheet of 2mm/3/15 mm of existing size and hinges to broken doors etc fixed with welding complete all as directed.
18Material and labour for cleaning debried around of LT panel / feeder piller box. cleaning the internal and external surfaces bus bar, terminal blocks, insulations using dry cloath, vaccum cleaner and blower. Check the tightenes of all electricals cable terminals, bus bar connection and earth connection. Check the serviceability of control switches, indicators, seceloter switches, apply lubricents to hings, locks and moving parts. Check the panel enclosure and gasket are sealed properly and preparation of existing surface of feeder piller box and panel including scraping of old paint and apply two coats of synthetic paint with spray gun of approved shade to ensure a smooth and uniform finish complete all as specified and directed. Note: 1. An electrician is required for checking all the electrical items.
19Supply, installation, commissioning and testingLT outdoor panel cubicle type of minimum size 1.2 Mtr (height) x 1.0 Mtr (breath) x 0.5 Mtr (depth) ,CPRI approved factory made, weather, dust & vermin proof outdoor cubical compartmental type, Doubledoor, front and back side openable, with providing rubber / PVC gasket of suitable size all sides of door, with Aluminium busbar chamber consisting of 4 nos of bus bar of capacity 400 Amps of aluminium bus bar 415 volts wrapped with PVC tape / sleeves with maintained the colour code and Aluminium strip busbar of suitable sizeto MCCB input and MCCB output of suitable length for connection of cable from main busbar, including digital multi function meter and Indicating lamps LED type ( R Y B) including wiring with suitable rated PVC insulated copper conductor wire, made out of 3.15 mm thick mild steel CRCAsheet with 50 x 50 x 6 mm size angle iron supporting frame andMC 75 channel base including applying two coats of Powder coated paint over exposed external & internal surfaces suitable for 3 phase 4 wire system 415 / 440 volts grade including complete connections and embedded in PCC foundation of size as required in cement mortar 1:4:8 and plastering the same in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and as directed.(a) MCCB 4 pole 200 Amps, 50 Hz of breaking capacity 36 KA -01 No(a) Onload changeover 200 Amps four pole - 01 No(b) MCCB 4 pole 100 Amps, 50 Hz of breaking capacity 25 KA -02 No(b) MCCB 4 pole 63 AMps,50Hz of breaking capacity 25 KA - 02 Nos (c) MCB SPN 32 AMps,50Hz- 02 Nos(d) CT operated digital Multi function meter - 01 Nos (e) LED type Indicating lamp (set of 3 ) - 01 set(f) Necessary wiring including material, fixing and connection to existing load.
20Supply and fixing MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 36 KA breaking capacity, rating 200 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian)
21Supply and fixing MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 160 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian)
22Supply and fixing MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 27 KA breaking capacity, rating 100 / 63 Amps including all fixing accessories with both ends spreader terminal connectors as per existing shape and size after taking down old unservicable one complete all as specified and directed.(Make :-Legrand/L&T/Havells/Indoasian)
23Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 10-16 Sqmm, 3.5/4.0 core, complete all as specified and as directed. MAKE: 3M/RAYCHEM/DENSONS
24Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 25-50 sqmm 3.5/4.0 core cable complete all as specified and as directed. Make : 3M/RAYCHEM/DENSONS
25Supply, fixing and testing of heat shrink LT cable straight through jointing kit suitable for 1100 volts grade 70-150 sqmm 3.5/4.0 core cable complete all as specified and as directed. MAKE: 3M/RAYCHEM/DENSONS
26Supply, fixing and testing of heat shrink LT cable indoor/out door jointing kit suitable for 1100 volts grade 10-16 sqmm 3.5/4.0 core cable complete all as specified and as directed. MAKE: 3M/RAYCHEM/DENSONS
27Supply, fixing and testing of heat shrink LT cable indoor/out door jointing kit suitable for 1100 volts grade 25-50sqmm 3.5/4.0 core cable complete all as specified and as directed. MAKE: 3M/RAYCHEM/DENSONS
28Supply, fixing and testing of heat shrink LT cable indoor/out door jointing kit suitable for 1100 volts grade 70-150 sqmm 3.5/4.0 core cable complete all as specified and as directed. MAKE : 3M/RAYCHEM/DENSONS

AI Tender Summary

OUR REF NO 52265808
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 9.50 Lakhs
LAST DATE 08-12-2025
Authority
Authority Name Military Engineer Services
Work Description Tender For Repairs To Lt Distribution System, Ug Cable, Panels, Mccbs And Other Misc Works At Afs Pukpui, Lunglei Under Age (I) (Af) Kumbhirgram
Basic Detail
Tender No 8735/2025-26/E8
Bidding Type Tender
Location
City lunglei
State Assam
Key Dates
Publish Date 01 Dec 2025
Submission Date 08 Dec 2025
Open Date 10 Dec 2025
Finance
Tender Value 9.50 Lakhs
Tender Fee 500
EMD 19000
Exemption Available
Document List
9978e632-c04c-43bd-ac75-6fdcd3550c70.html
BOQ_827483.xls
TenderDoc.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 01, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 08, 2025
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 01, 2025
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 08, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 10, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

9978e632-c04c-43bd-ac75-6fdcd3550c70.html

xls

BOQ_827483.xls

pdf

TenderDoc.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender