| 1 | Dismantling of ACSR or AAC conductors from overhead PCC/steel pole complete all as specified and directed by Engr-in-charge. |
| 2 | M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling complete all as specified and directed by Engineer-in-Charge. |
| 3 | M&L for PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling & mass concrete including necessary from work complete all as specified and directed by Engineer-in-Charge. |
| 4 | Dismantling of old Prestressed concrete pole and Supply & errect in position 11.00 mtr long prestressed cement concrete poles of cross section 152x152mm attop and 152x260mm at bottom, class 09 conforming to IS-1678-1978 complete all as specified and directed by Engr-in-charge. |
| 5 | M & L for Stay assembly complete with accessories as shown in electrical plate No 1 (loop type insulator,stay clamps, excavation and concrete sould be included in the rate and no separately measured) complete all as specified and directed by Engr-In-Charge. |
| 6 | Supplying and laying synthetic rubber insulated mats 2.5 mm thick for voltage upto 11 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed by Engr-in-Charge. |
| 7 | Material & labour for cross arms, bracing, supports, back plate & clamps fabricated from structural steel section including nuts, bolts, washer cutting, welding bending cold or hot, drilling holes for bolts in any shape for bolts in any shape or size inclusive of painting with 2 coats of aluminum paint over a coat of primer complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L forinsulator for HT aerial bunched cablecomplete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for HT Aerial Bunched cable of size 3x95 Sqmm Phase aluminium conductor, complete all as specified and directed by Engr-in-charge. |
| 10 | M&L for Suspension hook of HT Aerial Bunched Cable complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for self tightening anchoring Dead end clamp of HT Aerial Bunched Cable complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for PG Connector of HT Aerial Bunched Cable complete all as specified and directed by Engr-in-Charge. |
| 13 | M&L for Insulation piercing connector of HT Aerial Bunched Cable complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L for Suspension clamp with pole bracket of HT Aerial Bunched Cable complete all as specified and directed by Engr-in-Charge. |
| 15 | M&L for rubber insert of HT Aerial Bunched Cable complete all as specified and directed by Engr-in-Charge. |
| 16 | M&L for heat shrinkable type HT 11 KV Aerial Bunched Cable joint kit 95 x 3complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for spreading, levelling in electrical sub stations n exc. 150 mm thick of broken stone/ boulders (aggregates) of guage 40 to 80 mm complete all as specified and directed by Engr-in-charge. |
| 18 | Excavation in trenches in any type of soil not exc 1.5 mtr wide and not exc 1.5 m in depth in a hardsoil for laying underground cables/ errection of steel tubular poles / stay pit etccomplete all as specified and directed by Engr-in-charge. |
| 19 | M&L for spreading, levelling in layers n exc. 25 cm thick and ramming of sand cushioning to PVC/ XLPE cables with tibba sand and punning to provide required cover to UG cables. complete all as specified and directed by Engr-in-charge. Note :- For the purpose of payment only punned thickness will be measured. |
| 20 | Supplying and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 450mm x 180mm x 40mm complete all as specified and directed by Engr-in-charge. |
| 21 | Returning, filling in incl spreading,levelling watering and well ramming in layer n exc .25 cm in soil each layer complete specified and directed by Engr-in-Charge. |
| 22 | Removing excavated surplus material to a distance n.exc 50 m and depostimg where directed at alevel n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed by Engr-in-Charge. |
| 23 | Supply, layingand testingelectric under ground XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sqmm 3 Core in trenches, ducts, pipe on walls, poles complete all as specified and directed by Engr-in-charge. |
| 24 | Surface dressing n exc 15 cm deep and getting out in any type soil, levelling and removing grass, treemining of tree etc from side complete all as specified and directed by Engr-in-charge. |
| 25 | M&L for HT cable route marker complete all as specified and directed by Engr-in-Charge. |