Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Material and labour for taking down Window type air conditioner of any type/make/capacity after dismantling all electric connection from site (either in ground / any floor), transporting to work site if required, cleaning the condenser, brush cleaning the whole unit with electric blower, cleaning with water, decalingwith acid on both side of cooling coil and components, refixing the covers and making electrical connections, installation the machine in same position, testing and commissioning complete all as specified and as directed by Engineer-in-Charge (Note:Repair/Replacement of the component requiredshall be paid under relevant item of schedule here-in-after). |
| 2 | Supply & Fix in repairs air filter elemant pads for windowtype A/C for 1.5 TR/ 2 TRof size and make during the maintenance complete all as specified & as directed by Engineer-In -Charge. |
| 3 | Supply & Fix in repairs louvers swing motor suitable for window type AC of cap 1.5/2.0 ton capas per existing make and compatible model, necessary electrical connection and testing after fixing to entire satisfaction of Engr-in-Charge and user unit. |
| 4 | Repairs to Micro-processor electronic circuit board (PCB) suitable for 1.5/2.0 ton window type AC including dismentling andtaking out unsv PCB and and fixing after repairs, testing complete as per existingmake/model complete all as specified & as directed by Engineer-In -Charge.. |
| 5 | Supply & Fix in repairsCondensor fan motor double shaft 1/6Hp, 1/8Hp, 1/10HpforWindow type ACof 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and directed by Engineer In Charge. |
| 6 | Supply & Fix in repairs blower motor single phase AC 200/230 volts suitable for window type A/C for 1.5 TR/ 2 TR complete all as specified & as directed by Engineer-In -Charge. |
| 7 | Supply & Fix in repairs Air filter suitable for window type AC 1.5 /2.0 tr capacity as per existing make and model. |
| 8 | Supply & Fix in Repairsnew sealed unit compressor of 1.5 TR window type room air conditioner (Make: As Per Exisitingor Equivalant)complete all as specified & as directed by Engineer-In -Charge. Note - Gas charging shall be measured and paid separately under appropriate item of this schedule. |
| 9 | Supply & Fix in repairsCondenser coil unit of window type AC of cap 1.5 / 2.0 ton capacityas per existing make and competable model, connecting necessary copper tubings by brazing after dismentling/taking out existing unserviceable condenser unit & Fixing New Condenser Coil any Make/modeland testing after completion to entire satisfaction of Engr-in-Charge. Note: Gas charging shall be measured and paid separately under appropriate item of this schedule. |
| 10 | M & L Gas Charging and Repairs to window AC of unit1.5/2 TR capacities after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the equipment for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge.(Note- Refrigerant will be issued under respective Item of this Schedule) |
| 11 | Material and labour for shifting of window type AC of any capacity and make after dismantling of all electrical connection and carrying it to the new location and cutting the existing window including additions/alterations to makesuitable opening for fixing including welding/wood work as per site requirement to match with adjoining/existing surfaces and Refixing the window type air conditioner to the new altered location andmaking electrical connections, installation testing, commissioningand making good the disturbed surface to match with the existing surfaces complete all as specified and as directed by Engineer-in-Charge. |
| 12 | Material and labour for taking down split type air conditioner of any type/make/capacity after dismantling all electric connection from site (either in ground / any floor), transporting to work site if required, cleaning the condenser, brush cleaning the whole unit with electric blower, cleaning with water, decalingwith acid on both side of cooling coil and components, refixing the covers and making electrical connections, installation the machine in same position, testing and commissioning complete all as specified and as directed by Engineer-in-Charge (Note:Repair/Replacement of the component requiredshall be paid under relevant item of schedule here-in-after) |
| 13 | Supply and fix in repair condenser coilof copper suitable for 1.5 TR/2TR/3TR split type air conditionerincluding taking down old unserviceable condensor coil from existing position completeall as directed and specified by Engineer-In Charge. |
| 14 | Repairs to micro processor Circuit of existing Printed Circuit Board (PCB) in Split type AC of any make, complete all as specified & as directed by Engineer-In -Charge. |
| 15 | Supply and fix in repairs blower drum suitable for split type AC 1.5 TR/1.5 TR/3.0 TR complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Supply and fix in repairs New Micro-processor Printed Circuit Board (PCB) For split A/C ofas existing sample/make or equivalent,complete all as specified & as directed by Engineer-In -Charge. |
| 17 | Supply and fix in repairs Indoor blower motor single phase AC 200/230 volts suitable for split model A/Cof capacity 1.5 TR/2 TR/3TR(Make - As per Existing Make or equivalent), complete all as specified & as directed by Engineer-In -Charge. |
| 18 | Supply and fix in repairs Heavy duty air conditioner outdoor unit stand/ brackets with complete accessories for window/split AC of capacity of 1.5/2 Ton complete with grouting nut bolts all as specified and as directed by Engr-in-charge . |
| 19 | Supply and fix in repairs contactor switch suitable for (1.5TR/2 TR/3 TR Unit) split type unit complete all as specified & as directedby Engineer-in Charge. |
| 20 | Supply and fix in Repairs Suction valve for split ACof any capacity. |
| 21 | Supply and fix in Repairs Discharge valve for split ACof any capacity. |
| 22 | Supply and fix in repairsCondensor fan motor 1300rpm, 1/6Hp, 1/8Hp, 1/10Hpfor Split type Air Conditioner outdoor unit of 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and directed by Engineer In Charge. |
| 23 | Supply and fix in repaircopper tubes2 mm thickfor additional length required in the process of maitenance of the splitair conditioners unit, with insulationof puff or TF quality of thermocole or poly urithine insulating tubes all as specified for 5/8 inch copper tubing complete all as specified & as directed by Engineer-In -Charge. |
| 24 | All as per item here in above but of size 1/4 inch |
| 25 | All as per item here in above but of size 1/2 inch |
| 26 | All as per item here in above but of sizer 3/8 inch |
| 27 | Supply and fix in repair flexible cord PVC insulated and sheathed 3 core flexible with copper conductor of size 2.5 sq mm complete all as specified & as directed by Engineer-In -Charge. |
| 28 | Supply and fix in repairs 240 volts 32 amps capacity MCB single pole after taking out old unserviceable MCB from existing positionMake - Standard/Havells/MDS complete all as specified & as directed by Engineer-In -Charge. |
| 29 | M&L in replacement of air filter made out of nylon wire mesh moulded in plastic complete suitable for existing old filter\"s size and shape, as directed for 1.5/2/3 TR capacity of split type AC complete all as specified and as directed. |
| 30 | Supply and fix in repairs sheet metal enclosure single pole and neutral 2 Pin and earth metal plug and socket, 240 volts, (Make - Standard/ Havells/MDS), 32 Amps capacity after taking out old unserviceable DBfrom existing position complete all as specified & as directed by Engineer-In -Charge. |
| 31 | Supply and fix in repairs for PVC drain pipe suitable for split AC out let of 1.5T/2/3 TRcapacity. |
| 32 | Supply and Fix in repairs new sealed unit compressor of 1.5 TR split air conditioner (Make - As per Existing Make or equivalent) complete all as specified & as directed by Engineer-In -Charge.Note - Gas charging shall be measured and paid separately under appropriate item of this schedule. |
| 33 | Supply and Fix in Repairs new sealed unit compressorof 2.0 TR for split air cinditioner ( Make - As per Existing make or equivalent) complete all as specified & as directed by Engineer-In -Charge.Note - Gas charging shall be measured and paid separately under appropriate item of this schedule. |
| 34 | Supply and Fix in Repairs new sealed unit compressorof 3.0 TR for split air cinditioner ( Make - As per Existing make or equivalent) complete all as specified & as directed by Engineer-In -Charge.Note - Gas charging shall be measured and paid separately under appropriate item of this schedule. |
| 35 | Supply and fixinginreplacementNew indoor cabinet(unit)along with all Accessories for split AC 1.5 Ton capacity of suitable for existing out door unit fixing at any position, of any make including testing complete all as specified and directed by Engr-in-charge. |
| 36 | Supply and fixinginreplacementNew indoor cabinet(unit) along with all Accessories for split AC 2.0 Ton capacity of suitable for existing out door unit fixing at any position, of any make including testing complete all as specified and directed by Engr-in-charge. |
| 37 | Supply and replace remote control unit complete with 2 Nos Duracell battery of Split type AC1.5 ton /2.Ton including making frequency arrangement of new remote with existing system all as specified and directed by Engineer In Charge. |
| 38 | Supply and fix in repairs full body base suitable for 1.5 to 2 Ton capacity window / split type air conditioner, made out of GI sheet of 14 SWG and other portion with GI sheet of 20 SWG including motor mounting frame fixing with nuts and bolts of suitable size, duly painted with two coats of synthetic enamel paint over one coat of red zinc chrome primer etc complete all as specified and as directed by Engineer-in-Charge. |
| 39 | Supply and fix in repairs outer cover for window / splittype AC of Capacity 1.5 to 2 TR, made out of GI sheet 20 SWG, duly painting with two coats of synthetic enamel paint overone coat of red zinc chrome primer complete all as specified and as directed by Engineer-in-charge |
| 40 | M & L Gas Charging to split AC of 1.5/2 /3 TR capacities after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22/R-32 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling for the following complete all as specified & as directed by Engineer-In -Charge. (Note- Refrigerant will be issued under respective Item of this Schedule) |
| 41 | Taking downexisting split AC of any capacityindoor & outdoor unitwith supporting accessories/brackets& relocating the same Split AC (makingindoor unit and outdoor unit connections) duly mounted on brackets, connecting refrigerant piping , connecting up power supply,recommissioning & testing for smooth running,completeall as specified & directed by Engineer-In-Charge. |
| 42 | Repair to refrigerator of capacity190/220/300litres ,General servicing,dismantling unserviceable part of refrigerator, checking electrical connections & rewiring,cleaning of refrigerator unit ,and makingrefrigerator serviceable complete all as specified & as directed by Engineer-In -Charge.(Note:Repair/Replacement of the component requiredshall be paid under relevant item of scedule here-in-after) |
| 43 | Supply and fix in repairs copper strainer and capillary tube suitable for refrigeratormentioned above as per existing make and sample, in replacement of unserviceablestrainer & capillary complete all as specified & as directed by Engineer-In -Charge. |
| 44 | Supply & Fix in Repairs new sealed unit compressor unit (Make- As Per Exisitng make or equivalent) ,Suitable for 190 litrerefrigerator complete all as specified & as directed by Engineer-In -Charge. |
| 45 | Supply & Fix in Repairs new sealed unit compressor unit (Make- As Per Exisitng make or equivalent) ,Suitable for 220 litre refrigerator complete all as specified & as directed by Engineer-In -Charge. |
| 46 | Supply & Fix in Repairs new sealed unit compressor unit(Make- As Per Exisitng make or equivalent) ,Suitable for 300 litre refrigerator complete all as specified & as directed by Engineer-In -Charge. |
| 47 | Supply and fix in RepairsEvaporative cooling coil for refrigerator of capacity 190 to 300 litres of any model, type, size and capacity including testing etc complete all as specified and directedby Engineer-in-Charge. |
| 48 | Supply and fix in Repairs Condenser coil for refrigerator of capacity 190 to 300 litresof any model, type, size and capacity including testing etc complete all as specified and directedby Engineer-in-Charge. |
| 49 | Supply and fix in repairs NRV suitable forfor 190 /220/300 lit refrigerator,complete all as specified and directed by Engineer in Charge |
| 50 | Supply and fix in repairs vegitable tray in moulded PVC or plastic suitable for 190 /220/300 lit refrigerator ,complete all as specified & as directed by Engineer-In -Charge. |
| 51 | M & L Gas Charging to refrigeratorafter checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired coolingcomplete all as specified & as directed by Engineer-In -Charge. (Note- Refrigerant will be issued under respective Item of this Schedule) |
| 52 | M&L in replacement ofbroken freezer door complete with casing and lock nut as per sample for refrigerator of any capacity complete all as specified and as directed. |
| 53 | M&L in replacement ofvegetable tray complete suitable for existing model of refrigrator of any capacity complete all as specified and as directed. |
| 54 | M&L in replacement of chiller tray complete suitable for existing model of refrigerator of any capacity complete all as specified and as directed. |
| 55 | M&L in replacement ofmetal shelf powder coated suitable for existing model of refrigerator of any capacity complete all as specified and as directed. |
| 56 | M&L in replacement of bulb pin type/thread type suitable for existing model of refrigerator of any capacity complete all as specified and as directed. |
| 57 | M&L in replacement ofbroken door panel gasket complete suitable for existing model of refrigeratior of any capacity complete all as specified and as directed. |
| 58 | Repair to Deep freezer of capacity350 /500 ltrs ,general servicing ,dismantling unserviceable part,checking electrical connections & rewiring,cleaning of deep freezer unit ,reassembling & making deep freezer serviceable complete all as specified & as directed by Engineer-In -Charge. (Note:Repair/Replacement of the component requiredshall be paid under relevant item of scedule here-in-after) |
| 59 | Supply and fix in Repairs capillary tube and silica drier type strainer suitable for Deep Freezer350/500 litre capacity,complete all as specified & as directed by Engineer-In -Charge. |
| 60 | Supply and fix in Repairsnew sealed unit compressor (Make- As Per Exisitng make or Equivalent) for deep freezer of capacity 350litre completeall as specified & as directed by Engineer-In -Charge. |
| 61 | Supply and fix in Repairsnew sealed unit compressor (Make- As Per Exisitng make or Equivalent) for deep freezer of capacity 500 litre completeall as specified & as directed by Engineer-In -Charge. |
| 62 | Supply and fix in Repairs fan motor 1/35 HP suitable for deep freezer of capacity 300/500 litre , fan motor AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge. |
| 63 | M & L Gas Charging to Deep freezer after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressere, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge. (Note- Refrigerant will be issued under respective Item of this Schedule) |
| 64 | General Servicing to storage type water coolerof capacity40/80 & 60/120 ltrs , general servicing ,dismantling unserviceable part, checking electrical connections,cleaning internally and externally ,cleaning of water tank,tray &water outlet scraping with emery paper filling putty wherever required and painting with one coat of red oxide and two coats of synthetic enamel paint of approved colour and reassembling marking of MES/SM No in 25 mm size alphabetes,reassembling, refitting & making water cooler serviceable, complete all as specified & as directed by Engineer-In -Charge. (Note:Repair/Replacement of the component requiredshall be paid under relevant item of scedule here-in-after) |
| 65 | Supply and fix in Repairs fan motor 1/64 HP suitable for water cooler of capacity 40/ 80 ltr AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge. |
| 66 | Supply and fix in Repairs fan motor 1/32 HP suitable for water cooler of capacity 60 / 120 lit , AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge. |
| 67 | Supply and fix in repairs push type spring loaded taps chromium plated brass suitable for 15 mm dia bore of pipe for water cooler complete all as specified & as directed by Engineer-In -Charge. |
| 68 | Supply & fix flexible cold water nylon reinforced PVC c pipe for drain outlet, complete all as specified & as directed by Engineer-In -Charge. |
| 69 | Repair to water cooler stainless steel water tank including soldering existing copper pipe where ever necessary complete all as specified & as directed by Engineer-In -Charge. |
| 70 | Supply and fix in Repairs Brass Chromium plated stop cock both end screwed suitble for 15 mm dia GI Pipe complete all as specified & as directed by Engineer-In -Charge. |
| 71 | S&F in repair Set of Copper Pencil Strainer suitable for Water Cooler mentioned above including taking down old unserviceable copper pencil strainer, complete all as specified and as directed by Engineer-In-Charge. |
| 72 | S&F in repair aluminium fan blade for blower motor for water cooler of Capacity 40/80 ltrs/Hrs, 60/120 ltrs/Hr including taking down old unserviceable fan bladecomplete all as specified & as directed by Engineer-In -Charge. |
| 73 | Supply & fix in repairsRubber gasket for water cooler top cover as per samplecomplete all as specified & as directed by Engineer-In -Charge. |
| 74 | Supply and fix in repairs float valve assembly complete with PVC ball valve suitable for 15 mm bore of pipe for water cooler. Make: Prayag, Water tech complete all as specified & as directed by Engineer-In -Charge. |
| 75 | Supply and fix drain tray made stainless steel with required nuts, bolts or screws suitable for any cap incl dismentling taking out unserviceable one suitable for Water Cooler Make-Usha, Voltas or Blue Star whichever applicable. Note: Make & sizeof item shall be as recommended by the manufacturer ofWater Cooler. |
| 76 | Supply and fix in repair condenser coil unit of water cooler 40/80Ltrs or 80/120Ltrs cap as per existing make and competable model, connecting necessary copper tubings by brazing after dismentling/taking out existing unserviceable condenser unit and testing after completion to entire satisfaction of Engr-in-Charge suitable for WC Make-Usha, Voltas or Blue Star whichever applicable. Note: (i) Gas charging shall be measured and paid separately under appropriate item of this schedule. (ii) Make of item shall be as recommended by the manufacturer of water cooler. |
| 77 | S & F in replacement PVC connection 15mm size with PTMT nuts of following sizes :-600 mm |
| 78 | All as per Item above but of size 900 mm |
| 79 | All as per Item above but of size1200mm |
| 80 | Taking out old broken PVC flexible drain outlet pipe & S & F new drain outlet pipe 32/40mm dia complete for water cooler of any capacity complete all as specified and as directed. |
| 81 | M&L for replacement of old worn out / burnt wiring of water cooler/ deep freezer by using copper conductor wire PVC sheathed of suitable size and length complete all as specified and as directed. |
| 82 | All as per item above but for window/split type A/C of any capacity complete all as specified and as directed. |
| 83 | M&L for repair/replacement of corroded bottom portion of the water cooler of any make & capacity with MS angle iron of suitable size as per existing, including welding/brazing with MS sheet 1.6mm thick at the base of water cooler for mounting of compressor, blower motor, etc complete all as specified and as directed. |
| 84 | Supply and fix in repairs old defective water storing body of water cooler 40/80 ltr capacity by dismantling the outer body of the storage tank after disconnecting its suction and discharge line, taking out glass wool safely placing new stainless steel water storing body of same size including packing with glass wool, connecting suction/discharge line and fixing of body etc complete all as specified and as directed by Engineer-in-Charge. |
| 85 | Supply and fix in Repairs new sealed unit compressor (Make :As per Exisitng Make or Equivalent) Suitable for water coolerof capacity 40/80 litre complete all as specified & as directed by Engineer-In -Charge. |
| 86 | Supply and fix in Repairs new sealed unit compressor (Make :As per Exisitng Make or Equivalent) suitable for water coolerof capacity 60/120 litre complete all as specified & as directed by Engineer-In -Charge. |
| 87 | M & L Gas Charging to water cooler after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge.(Note- Refrigerant will be issued under respective Item of this Schedule) |
| 88 | Supply and Fix in Repairs swing motor for Split AC as per existing Sample |
| 89 | Supply only Refrigerant (R-134a)gas (enclosed in seamless steel cylinder) Note:The empty cylinder available with MES will be exchange) duly testedof complete all as specified and as directed by Engineer-in-Charge. |
| 90 | Supply onlyRefrigerant(R-22) gas (enclosed in seamless steel cylinder)Note:The empty cylinder available with MES will be exchange)duly tested of complete all as specified and directed by Engineer-in-Charge. |
| 91 | Supply onlyRefrigerant(R-32) (enclosed inseamless steel cylinder, Note:The empty cylinder available with MES will be exchange)duly tested complete, all as specified and directed by Engineer-in-Charge. |
| 92 | Supply and Fix in Repairs over load protector of various capacities for split AC, Winodw AC, water cooler, Refrigerator, deep freezer, complete all as specified & as directed by Engineer-In -Charge. |
| 93 | Supply and Fix in Repairsthermostats with control knob of various capacities split AC, Winodw AC, water cooler, Refrigerator, deep freezer, complete all as specified & as directed by Engineer-In -Charge. |
| 94 | Supply and Fix in Repairs blower/condensor fan blades as per existing make & type for Air conditioner/Water cooler/deep freezer/Desert Cooler all as specified and directed. |
| 95 | Supply and Fix in Repairsrelay suitable for split AC, Winodw AC, water cooler, Refrigerator, deep freezer etc,complete all as specified and directed by Engineer in Charge. |
| 96 | Supply and Fix in Repairs starting capacitor for split AC, Winodw AC,, water cooler, Refrigerator, deep freezer etc of capacity 80/100 mfd 440 VAC Make Epcos or Equivalent, complete all as specified and as directed by Engineer -in -Charge. |
| 97 | S&F digital display unit of indoor unit suitable to split AC of capacity 1.5 TR/ 2 TR/ 3 TR as per existing sample and size including making connections, dismantling & taking out old unserviceable one all as directed. |
| 98 | Material and labour for drilling hole 80 mm dia in stone/ bricks masonary wall with the help of core cutting machine for passing of cable or copper pipe of split ACs, including filling of hole with the help of white cement complete all as directed. |
| 99 | S&F wireless temperature and RH data logger for measuring temerature and humidity,make HTC or equivalent,Complete all as specified and directed by Engineer-in-charge. |
| 100 | S&F ruberinsulation superior quality around the copperpipeforsplit AC as per existing type complete and also including dismantling& taking out old unserviceable one all as directed. complete all as specified and directed by Engineer-in-Charge. |
| 101 | S&F openwell submersible pump of capacity 1 hp Single phase 230 Volt Make-Kirloskar(Kosi-135)or Equivalent including cables & starter complete all as specified & as direced by Engineer-in-Charge. |
| 102 | Supply and Fix in Repairs capacitor for split AC, Winodw AC, water cooler, Refrigerator, deep freezer etc of capacity 2.5 to 25 mfd Make -Epcos or Equivalent , complete all as specified & as directed by Engineer -in -Charge. |
| 103 | Supply and Fix in Repairs running capacitor for split AC, Winodw AC, water cooler, Refrigerator, deep freezer etc of capacity 36/45/50/60 mfd , 440 VAC MakeEpcos or Equivalent ,complete all as specified and as directed by Engineer -in -Charge. |
| 104 | S&F in repair Sluice valve with flanged ends cast iron body flanged and drilled forsizes as per IS- 14846 including all joints with rubber for fiber board bolts nuts and washers, also including the necessary pre-drilled flange according to site condition for adjustment in existing pipes to fit the sluice valve tightly with stainless steel wedge nut and gun metal spindle class PN 1.6 with operating wheel complete 150mm dia at / in side valve chamberorany height in a vertical position on main raising pipe line at top of RCC OH Reservoir staging 60 feet heightcomplete including with providing a scaffolding on top at RCC OH tank as prevention to humansafety completeas all directed . |
| 105 | Supply and Fixin repair PVC/CI Foot valve complete ofsize 150 mm dia. |
| 106 | S&F Rubber Gasket Packing for different sizes of Sluice/foot valves of 6 mm thickness . |
| 107 | Material & Labour for carring out repairs to Existing Star delta starter in open execution ,identifying the fault in wiring,rectifying the wiring fault using suitble flexible copper cable,thimblesReplacement of time delay(timer), single phasing preventer & suitable relay with new one(as required as per its specification or as specified by Engineer -In Charge) ,rewiring of complete starter using suitable size flexible copper cable, suitable upto120 HP electric induction motorschecking the motor at site complete for its continuity /any malfunctioning across winding ,replacing its terminal plate and testing of electric motor winding/Pumpset to the complete satisfaction of Eng-In-Charge,complete all as specified and as directed by Engineer-In-Charge.(Note :Spares required other than mentioned above in the process of maintenance will be measured and paid separately under relevant item of this Schedule.) |
| 108 | Dismantling and taking down burnt out electric motor carefully after disconnecting all electric connections. Transportating to the workshop(Workshop will be decided by Engineer-in-Charge)by the contractor own arrangement for re-winding of the motor with approved quality insulated copper wire of suitable gauge same number of turns and same numbers of poles complete with Varnishing of re-wounded coils with insulated and packing materials, and tapping of coils, and heating in oven at desired temperature and refixing the motor with proper alignment with pump for trouble& noise free operation , & reconnect all the connections of starter and testing complete for 25 HP motor all as directed by Engr-in-Charge. |
| 109 | All as per item no 108 above but 20 HP for VT motor. |
| 110 | Taking Out Submersiblepump carefully from Dharna River of capacity 15 HP after disconnecting all electric connections.re-winding of the motor with approved quality insulated water proof copper wire of suitable gauge same number of turns and same numbers of poles complete with Varnishing of re-wounded coils with insulated and packing materials, and tapping of coils, and heating in oven at desired temperature,replacement of existing bearing reconnect all the connections of starter and testing complete and place the motor in dharna river all as directed by Engr-in-Charge. |
| 111 | M&L for dismantling and taking down burnt out electric motor carefully from high lift pump of Capacity 120 HP after disconnecting all electric connections etc and shifting to work shop(Workshop will be decided by Engineer-in-Charge) for the following works and transporting back to site, reassembling and re-installation of motor with proper alignment to match with the pump shaft coupling and testing after commissioning complete :- (a) Complete opening and taking out rotor from armature (stator) (b) Removing all brunt out/damaged windings from stator. (c) Complete cleaning & removal of carbon of stator inside body. (d) Complete re-winding of the motor with approved quality insulated copper wire of same guage,same number of turns and same number of poles complete. (e) Complete varnishing of re-wounded coils insulating materials, and packing materials, and tapping of coils, and heating in oven at desired temperature. (f) Complete cleaning of motorand re-fixing with the re-wounded starter assembling, fixing complete. |
| 112 | M&L for dismantling and taking down brunt out electric motor carefully from high lift pump of Capacity 100 HP after disconnecting all electric connections etc and shifting to work shop(Workshop will bedecided by Engineer-in-Charge) for the following works and transporting back to site, reassembling and re-installation of motor with proper alignment to match with the pump shaft coupling and testing after commissioning complete :- (a) Complete opening and taking out rotor from armature (stator) (b) Removing all burnt out/damaged windings from stator. (c) Complete cleaning & removal of carbon of stator inside body. (d) Complete re-winding of the motor with approved quality insulated copper wire of same guage,same number of turns and same number of poles complete. (e) Complete varnishing of re-wounded coils insulating materials, and packing materials, and tapping of coils, and heating in oven at desired temperature. Note for Item no. 5 to 9:Warranty period of rewinding of motor must be 6 month. |
| 113 | Dismantling and taking up carefully vertical turbine pump set 20 HP installed at jack well of 42 feet depth, half of the column pipe submerged in 10 feet of water under jackwell, after disconnecting the electric connection transporting the pump along with connected accessoriesto the workshop (workshop will be decided by Engineer-In-Charge)and keeping aside the electric motor at safe place for reinstallation and taking up all column pipe 150mm dia ,shaft,pump,strainer etc, for the following repair works andreplacement of parts and reassembling, errection ,installing at existing locationand testing completeall as directed:- (a) Replacement of broken and worn out line shaft complete-8 Nos (b) 4 stage Bowl Assembly & Old Bush Boring -4 Nos (c) Replacement of bowl shaft gun metal bush-1 Nos(d) Impeller boring lathe work completeincluding metal filling & Bearing-4 Nos (e) Line shaft polish, granding ,lathe work complete and painting -10 Nos (f) Cleaning & threading of Line shaft coupling-11 Nos (g)Replacement of Top shaft - 1 Nos (h) Replacement of bowl assembly lock system-01 Nos (i) Replacement of Spider guide with rubber bush - 08 Nos (j) Replacement of gland box lathe-work complete with suitable bush-1 set(k) Repairs to impeller shaft & shaft sleeve by metal filling,turning & finishing & all lathe works- 01 job(l) Repair/over hauling of impeller assembly and replacingimpellerseal ring and necessary welding-04 JOB (m)Replacement of all glands of suitable size-01 job(n) Replacement of top column flange-01 job (o)Replacement of ratchet spring& repair -01 job (p) Replacement of bearing holder -02 Nos (q) Replacement of line shaft bush-08 Nos (r)Painting with epoxy paint to pump body and synthetic enamel paint of existing colour in 2 coat to column pipe after complete cleaning and dusting of old painted surfaces complete-01 Job (s) Foundation Channel replacement as per existing-01 Job (t) Replavement of SS shaft OD 32 mm x length 45\"(u)Replacement of bowl bush & muff coupling-05 nosNote: Unit rate quoted for above item shall be deemed to includefor the following:-(1) Any unfore seen minor spares/parts not specified above but requires to be replaced shall be provided and replaced (2)Replacement of complete nuts,bolts and washers wth high strength GI nuts,bolts and washers of existing type. |
| 114 | M&L for Repairs to centrifugal pump set of capacity 120 HP,Pump type-DSM 125/40, installed at Pump House by dismantaling the pump set carefully from its connected electric motor including disconnecting and taking outelectric motor, transporting pump set to wokshop (workshop will be decided by Eng-In-Charge)repairing /servicing the pump with following repairs as specified and directed by Engineer-in-Charge (a) Replacement of bearings of suitable size Make SKF(bearing no. Drive end-6309,Non drive end-3309) (b) Repairs to shaft sleeve,pump shaft of suitable size (c) Replacement of bush cast alloy of suitable size (d) Replacment of oil set& coupling complete (e) Replacement of impeller key and coupling key of suitable size (f) Replacement of terminal plate of elelctric motor (g) Replacment of \"O\" ring for shaft sleeve of suitable size.(h)Replacement of bolts with nuts for upper and lower half casing.(i)Repairs to impeller shaft by metal filling,turning & finishing & all lathe works.(j)Replacement of all glands of suitable size.(k)Replacement of bearing nut,bearing cover and bearing cap of suitable size.(L)Transporting the pump back to site after repair and refixing & recommissioning on its original position by coupled with motor with proper allignment for trouble & noisefree operationand including scrapping the entire surface and painting it two coats of synthetic enameled paint over a coat of red oxide paintwriting MES No and testing the pump set with complete satisfaction of Enginer-in-Charge. Note: Unit rate quoted for above item shall be deemed to includefor the following:-(1) Any unfore-seen minor spares/parts not specified above but requires to be replaced shall be provided and replaced (2)Replacement of complete nuts,bolts and washers wth high strength GI nuts,bolts and washers of existing type. |
| 115 | M&L for Repairs to centrifugal pump set of capacity 100 HP,Pump type-DSM 125/40, installed at Pump House by dismentaling the pump set carefully from its connected electric motor including disconnecting and taking outelectric motor, transporting pump set to wokshop(workshop will be decided by Engineer -In -Charge) repairing /servicing the pump with following repairs as specified and directed by Engineer-in-Charge (a) Replacement of bearings of suitable size Make SKF(bearing no. Drive end-6309,Non drive end-3309) (b) Repairs to shaft sleeve,pump shaft of suitable size (c) Replacement of bush cast alloy of suitable size (d) Replacment of oil set & coupling complete (e) Replacement of impeller key and coupling key of suitable size (f) Replacement of terminal plate of elelctric motor (g) Replacment of \"O\" ring for shaft sleeve of suitable size.(h)Replacement of bolts with nuts for upper and lower half casing.(i)Repairs to impeller shaft by metal filling,turning & finishing & all lathe works.(j)Replacement of all glands of suitable size.(k)Replacement of bearing nut,bearing cover and bearing cap of suitable size.(L)Transporting the pump back to site after repair and refixing & recommissioning on its original position by coupled with motor with proper allignment for trouble & noise-free operation and including scrapping the entire surface and painting it two coats of synthetic enameled paint over a coat of red oxide paint & writing MES No and testing the pump set with complete satisfaction of Enginer-in-Charge. Note: Unit rate quoted for above item shall be deemed to includefor the following:-(1) Any unfore seen minor spares/parts not specified above but requires to be replaced shall be provided and replaced (2)Replacement of complete nuts,bolts and washers wth high strength GI nuts,bolts and washers of existing type. |
| 116 | M&L for Repairs to centrifugal pump set of capacity 25 HP installed at Pump House by dismentaling the pump set carefully from its connected electric motor including disconnecting and taking outelectric motor, transporting pump set to wokshop repairing /servicing the pump with following repairs as specified and directed by Engineer-in-Charge (a) Replacement of bearings of suitable size Make SKF (b) Repairs to main spindle shaft of suitable size (c) Replacement of bush cast alloy of suitable size (d) Replacment of oil set complete (e) Repairs to key and impeller of suitable size (f) Replacement of MS coupling with tyre coupling of suitable size. (g) Replacement of terminal plate of elelctric motor (h) Transporting the pump back to site after repair and refixing & recommissioning on its original position by coupled with motor with proper allignment with and including scrapping the entire surface and painting it two coats of synthetic enameled paint over a coat of red oxide paint and testing the pump set with complete satisfaction of Enginer-in-Charge.Note: Unit rate quoted for above item shall be deemed to includefor the following:-(1) Any unfore seen minor spares/parts not specified above but requires to be replaced shall be provided and replaced (2)Replacement of complete nuts,bolts and washers wth high strength GI nuts,bolts and washers of existing type. |
| 117 | Supply and Fix Contactor kitcat no. SS95315 for 4 Pole Power contactor ML 10,Make -L&Tor equivalent ,Complete all as specified and directed by Engineer -in-charge. |
| 118 | Supply and Fix 4 Pole Power contactor ML 10,cat no. SS95315,Make-L&T or Equivalent, Complete all as specified and directed by Engineer -in-charge. |
| 119 | Supply,install testing & commissioningof LT Panel INDOOR TYPE made out of 2.00 MM IP43 CRCA Sheet duly powdered coated 8 tanks process copper bus bar 200 A,I/C MCCB 100A 4P 25 KA 01 Set,MFM +LED 01 Set,O/GS MCCB 63 A TP 25 KA-02 Nos,MCCB 25 A TP 25 KA-01 No,Star delta starter -25 HP-02 Nos,DOL 5 HP Starter-01 no,All starter shall have Ammeter,voltmeter,SPP,PB,LED All as specified. MCCBs : Legrand & Starter components :Siemens/ABB/Legrand |
| 120 | M&L for cross arms / plain iron sheet as per site requirment includingbracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paintfor repair of over head tank lader all as specified and directed by Engr-in-Charge.Note : Contractor is responsible for safety of his men while fabricating the work. He is also resposible to provide the safety equipment to the worker without any extra cost to the department. |
| 121 | Supply and fix galvanised iron strip of size 25 X 4 mm as earth continuity conductor for roofand down conductors fixed/run on wall/celing/roof of any type of bulilding/hanger/Wksp/structure with proper clamping or saddling duly supported on porcelain/polycarbonate/wooden block with suitable fixing arrangement of nuts & bolts or psses through wall by making hole orany other indicated situation,complete all as specified & as directed by Engineer -In -Charge. |
| 122 | Material and labour for earthing complete with galvanised earth plate electrode of size 60cm x 60 cm x 3.15 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5 mtr below ground levelconnected to galvanised iron strip of size 25 X 4 mmby means of of galvanized iron nuts & bolts &brazing or as directed at site by Engineer -in-Charge protected by GI Pipe 40 mm dia light grade and connected to test point and further connected to equipment, machinery, electrical panel or any other as directed by Engineer-in-Charge, which to be earthed, all as shown in electrical plate No 3 of SSR Part I including providion of concrete earth pit constructed in PCC 1:3:6 type C-1 as earth pitand PCC 1:2:4 type B-1 for cover slab with necessary reinforcement with handle for lifting also including provision of funnel with wiremesh with 20 mm GI pipe medium gradefor watering, charcoal and salt in alternative layers of 15 cm thick all around the electrode , including necessary excavation and earth work , testing and commissioning ,complete all as specified & as directed by Engineer -In -Charge. |
| 123 | M&L for cutting of grass, vegitation,bushes and small tree branches by manually or machine and depositing where dircted n exc 100 mtr awayand cleaning the area in installation or along the pipe line complete all as directed. |
| 124 | Supply and fix in repairdigital voltmeter 3 phase 430 Volt, 50 Hz and fix to existing panel including making connectios complete. |
| 125 | Supply and fix in repairdigital Ampere meter with suitable ratio of CTs, AC , 3 Phase 430 Volt, 50 Hz and fix to existing panel including making connectios complete. |
| 126 | Supply and fix in repair fully atutomatic star delta starter suitable to pumpset motor, 3 Phase, 415 volt 50 Hz, 25 HP capactiy make-L&T or Equivalent, with single phase prevention protection feature, timer,contactor of suitable capacity, relays for overload protection and short circuit complete, totally enclosed in sheet metal enclouser and to be fix on wall including making connections to the motor complete all as directed. |
| 127 | Supply and fix in repair fully atutomatic star delta starter suitable to pumpset motor, 3 Phase, 415 volt 50 Hz, 20 HP capactiy make-L&T or Equivalent, with single phase prevention protection feature, timer,contactor of suitable capacity, relays for overload protection and short circuit complete, totally enclosed in sheet metal enclouser and to be fix on wall including making connections to the motor complete all as directed. |
| 128 | M&L for cleaning of raw jackwell of size 6.5 mtrs dia and 15 mtr depth by removing sludge and siltcompletely with suitable pumps from the bottom by jackwell,scrapping out deposit,sludge etc form the side wall of jackwell with the help of scrapper,wire brush etccomplete all as specified and directed by Engr-in-charge. |
| 129 | M&L for cleaning of settlement tankby removing sludge and silt completely with suiable pumps from the bottom of settlement tank, scrapping out deposited sludge etc,from the pump house,After washing clearly with clear water drying in open and applying two coats of white wash in container portion and paintingtwo coats of synthetic enameled paint over a coat of red oxide paint on pipes. complete all as specified and directed by Engr in charge. |
| 130 | M & Labour for Washing out Under ground fresh water reservoir of capacity 1,25,000 gallons including ,removing of algae, cleaning the internal portions with mechanical scrappers wire brush, brooms etc cleaning internal portion with high pressure water jet and using pressure jet pumps. Cleaning with clear water and removing the sediments applying suitable bleaching powder solution. After washing clearly with clear water drying in open and applying two coats of white wash in container portion complete including synthetic enamel paint overincomming and outgoing pipes, wash out pipe complete and cleaning vegetation/bushesh around 100 meter radiusetc complete all as directed by Engineer-in-Charge.Note for Ser Item No 128,129, 130: i) The rate quoted by the cotractor is deemed to be included the cost ofbleaching powder, wire brush, mechanical scrapper including synthetic enamel paint overincomming and outgoing pipes, wash out pipe complete and cleaning vegetation/bushesh around 100 meter radius etc complete .ii) Contractor is responsible for safety of his men while cleaning the under ground storagetank,settlement tank,jackwell,and working inside. He is also resposible to provide the safety equipment to the worker without any extra cost to the department.iii) The contractor is fully responsible for any blockage or depositing sludge to the delivery lines. He will rectify all such defects on his own expense.iv) Contractor shall inform in writing 10 days before for cleaning of under ground sump,settlement tank and jackwell .v) Contractor is also responsible to write cleaned date on board with paint. |
| 131 | Material & labourto collect water sample from existing source in empty sterilized bottels/Can for sending it to govt acredittedNABL lab for the testing of water(as per IS 10500:2012)Bacterial (PH Value, temperture, turbidity,NTU,Max,total hardness,Alkalinity, TDS PPT Max , Iron mg/L, Nitrate mg/L , CHLORIDE mg/LResidual chlorine mg /L fluoride mg /L,sulphate mg /L etc.) & Chemical test ,( Coliform orginisms MPN/100/ml , Total COLIFORMS mpn/100/ml,Escherichia COLIFORMS mpn/100/ml,etc) andreportto besubmit toAGE E&M office for further action.(Note : Contractor will take one sample for fresh water , one sample for Raw water and report will submit to Engr in charge , both the report will be considered as one job only. ) |
| 132 | Material & labour for repairof Electromagnetic flow water meter of size 250/150 mm dia pipe and transmitter,electrode,electromagnet,SMPS,PCB ,repair to circuit complete and submission of caliberation report from approved OEM/caliberation agency , making it completeservicebleall as specified and directed by Engr in charge. |
| 133 | Material & labour for replacementof 3 core Shielded Cable for Electromagnetic flow water meter of size 250/150 mm dia pipe ,all as specified and directed by Engr in charge. |
| 134 | Supply only calcium Hypo Chlorite,65% to 70% chlorine content in granular(calsium based granular disinfectant for water treatment for drinking purpose packed in non returnable plastic drum of 45 KG complete brand having pan india availibility accepteability and being maufactured in open market termed as traditional product . The brand /make meeting technical contractor shall render purchases vochers & test certificates aganist each lot of delivery.Make :As approved by CMPT Engineer-in-Chief Branch, New Delhi, requirment as per PS must havecertified by all India Institute & public health. , complete all as specified and directed by Engr-in-Charge. |
| 135 | Supply only Aluminia ferric grade-I, Type- I. Make: Vikram Industries/ Almighty all as specified and directed by Engineer- in-ChargeNOTE for item No 31 & 32:Item will be suppliedby the contractor as per department requirement only . Bulk items or complete contract items will not accepted at one time. |
| 136 | Supply only Orthotolidine solution (O-Todine reagent) 500 ml Chlorine estimator enclosed in glass bottle all as specifed and directed by Engineer-in-Charge. Make: Thermo Fisher Scientific India Pvt Ltd or equivalent as approved by GE. |
| 137 | S&F Cast iron non return valve (Reflux valve) 150 MM with bi-pass arrangement with flanged ends cast body confirming to IS-5318:1984 part I, swingtype with natural rubber flap, flagned drilled class PN 1.6 including all necessary rubber packing, bolts nuts and washers complete all as directed . |
| 138 | S&F Cast iron non return valve (Reflux valve) 125 MM with bi-pass arrangement with flanged ends cast body confirming to IS-5318:1984 part I, swingtype with natural rubber flap, flagned drilled class PN 1.6 including all necessary rubber packing, bolts nuts and washers complete all as directed . |
| 139 | M&L for construction of valve pit chamber of internal size1200x1200x1000mmincluding necessaryexcavation,returning,filling-in, and removal of surplus soil to a distance not lessthan250m,100mmthickPCC(1:4:8) Type-D-2(using40mmgradedstoneaggregate) in foundation, 230 mm thick brick work in cement mortar (1:4), PCC 1:2:4 TypeB1 (using20 mm graded stone aggregate) for coping including necessary form work, 15 mm thickplasteringincementmortar(1:4) including 5 mm thick MS sheet cover fixed on MS angle iron 50x50x6 mm, painting with 2 coats of synthetic enamel paint over a coat of red-oxideprimeronallsteel/iron/surfaces andprovisionofsuitablelocking arrangementcompleteallasspecifiedand directed. |
| 140 | Supply testing & commisioning long reach pole pruner HT 75,HSN Code-8467, having power output:0.95 kw/1.3 hp,displacement-25.4 cm3 ,weight:6.6 kg, Reach from ground -5 m ,Petrol operated ,make -Stihl or equivalent in Husqvarna or Stanley black &Decker. |
| 141 | M&L for refixing of dislocated/ uprooted GI/Copper Strip along with insulator from wall/ celing or any other location as directed from any DG set/ panel/any type of structure any size and shape. Refixing should be done in proper dressing and alignement on existing insulator or replaced with new one if broken/ unserviceable complete all as directed by Engineer-in-Charge.NOTE: i) The quoted rate is deemed to be include the rate of necessary nuts & bolts used to refix the strip on insulator or the clamps along with nuts & bolts required to fix the GI pipe in vertical postion on wall / ceiling/ floor etc complete. |
| 142 | M&L for jointing MS ERW pipe 250 mm bore of pipe,spigot and socket and MS fittings,Nut ,bolts and washer complete all as specified and directed by Engr-in-charge .(Item is to be executed at existing pipeline cutting existing pipeline and inserting MS pipe with complete fabricated work is included in the job) |
| 143 | M &L for Bends (any type, radius and angle) tappers and type, (straight, bend , increasing, decreasing, or double socket etc). Tee pieces, single branch, Y junction double branch, cross (all socket of socket and spigot) collars, caps,and plugs including mechanical joints) also including connecting tail pieces of one flanged other end spigot or one end socket and other end flanged upto 300 mm bore of pipe. |
| 144 | Supplying and laying of CPVC pipes SDR 11,25 mm bore & Plain CPVC SDR 11 fittings in trenches/wall/celing complete all as specified. |
| 145 | Disconnecting the electricaL connection of burnt electrical motors of capacity up to 2 HP, from the existing site / location, transporting to and return back from work shop. Rewinding of electrical motors by dismantling and removing the burntcopper winding wire, cleaning the slots of stator with petrol and brushes, winding polyster based super enamelled copper wire of same gauge of original one with proper class of insulation including varnishing and heating the coil and remove air bubbles complete stator / roter after rewinding reassembling all parts including re-installing connection to original position and testing on full load all as directed by Engineer -in -charge. |
| 146 | S&F Twin LED Aviation light with polycarbonate diffuser & Cast aluminium housing IP 65,Cat no-SZPALMX-2, Make Shakti or Equivallent in Crompton,Bajaj. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail