| 1 | S&F mild steel framed work as in doors or gates of angle or other section with gusset plates, rails,braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering,running rails and guides) and hanging; also fastening and fixing complete conforming to Fe.410 W.Gde-E-250 complete all as specified and directed. |
| 2 | Cutting holes exc. half brick but not exc. one brick in brick walls built in cement mortar for inserting mild steel sections/ holdfasts and making good dismantled portion in including cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required complete all as specified and directed. |
| 3 | M&L for applying two coats of syntheticenamal ordinary tint paint inclduingredoxide primer and prepartion extra complete on new steel or iron surfaces of any description, over 10cm in width or grith not otherwise described complete all as specified and directed. |
| 4 | M & L for providing wall care putty not less than two mm thick on old or new plastered surface of wall complete all as specified and directed. |
| 5 | M & L for preparation of new surfacesand applying two coats ofoil bound distemper over a coat of primer complete all as specified and directed. |
| 6 | M&L for preparing new surface and applying two coats of cement based paint over a coat of primer complete all as specified and directed. |
| 7 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft / loose soilcomplete all as specified and directed. |
| 8 | Excavating over areas, not exceeding 1.5 m deep and getting out in soft /loose soilcomplete all as specified and directed. |
| 9 | M & L for Cement concrete 1:3:6 type C-2(40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 10 | M&L reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) in foundations, including rafts,footings, foundation beams;plinth beams; bases for columns, etc.; basement slabs,under-reamed piles and mass concrete complete all as specified and directed. |
| 11 | M&L reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded aggregate) in Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 12 | Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter etc to fair finish surfaces of conc.complete all as specified and directed. |
| 13 | Use and waste of formwork to sides of pillars,posts, struts, piers, columns and stanchions of circular, square ,rectangular or polygonalon plan etc. sufaces finished fair of conc.complete all as specified and directed. |
| 14 | M&L TMT bars 10mm dia & over cut to length bent to shape required, including cranking, benching, spirally for hooking for columns, hooking ends and bending with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 15 | S&F framed work of angle iron or MS circular pipes using in such as grill ,gratings ,water tank stagings and similar works with ends of bars shouldered and/ or rivited,welded or forged into spikes confirming to Fe-290 grade E-165 etc. complete all as specified and directed. |
| 16 | M&L for applying two coats of syntheticenamal ordinary tint paint inclduingredoxide primer and prepartion extra complete on new steel or iron surfaces of any description, over 10cm in width or grith not otherwise described complete all as specified. |
| 17 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. of hard/dense soil complete all as specified and directed. |
| 18 | Removal of surplus spoil upto a distance n. exc 50 M and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed |
| 19 | Dismantling water tanks and removing to store of capacity250 to 500 Ltrcomplete all as specified and directed |
| 20 | S&F rotational moulded polyethylene water storage tanksof 500 Ltrs capacity (cylindrical vertical with closed top) hoisted fixed in position all as specified in SSR Part I complete all as specified and directed |
| 21 | Disconnecting existing tanks of cap. 250 to 500 Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in same or other locations. complete all as specified and directed Note :-Cleaning repairing, etc. measured separately under respective items |
| 22 | Cleaning and removing all scale and dirt, etc, from tanks of cap. 250 to 500 Ltrs, and from mouths of circulating pipes, etc complete all as specified and directed |
| 23 | S&F in repair ball valves brass high pressure with polythelene float and fly nut complete, screwed , iron pipes 20 mm dia complete all as specified and directed. |
| 24 | Taking up or down steel tubing and connections,including cleaning for refixing or removal to store of 15 mm bore of pipe complete all as specified and directed |
| 25 | S&F GI water tubing/pipe 15 mm bore with alll fittings fixed to wall or laid in floors or celings in any positioncompete all as specified and directed |
| 26 | Refixing old 15mm bore steel tubing and connections in new or old position (Walls, ceiling,floors, etc.) complete all as specified and directed |
| 27 | Taking up or down steel tubing and connections,including cleaning for refixing or removal to store of 20 mm bore of pipe complete all as specified and directed |
| 28 | S&F GI water tubing/pipe 20 mm bore with alll fittings fixed to wall or laid in floors or celings in any positioncompete all as specified and directed. |
| 29 | Refixing old 20mm bore steel tubing and connections in new or old position (Walls, ceiling,floors, etc.) complete all as specified and directed. |
| 30 | Taking up or down steel tubing and connections,including cleaning for refixing or removal to store of 25 mm bore of pipe complete all as specified and directed. |
| 31 | S&F GI water tubing/pipe 25 mm bore with alll fittings fixed to wall or laid in floors or celings in any positioncompete all as specified and directed |
| 32 | Refixing old 25mm bore steel tubing and connections in new or old position (Walls, ceiling,floors, etc.)compete all as specified and directed. |
| 33 | S&F in repair 20mm dia of bore gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixedcompete all as specified and directed. |
| 34 | S&F 20mm dia of bore gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixedcompete all as specified and directed. |
| 35 | S&F in repair 15mm dia of bore gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixedcompete all as specified and directed. |
| 36 | S&F 15mm dia of bore gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixedcompete all as specified and directed. |
| 37 | Demolition of brick work built in cement mortar including all quoions, arches pillar etc complete all as specified and directed. |
| 38 | M&L brick work with sub class \"B\" old size bricks, straight or curved on plan exec 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 39 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness complete all as specified and directed. |
| 40 | M & L for 40 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in floor finished even and smooth without using extra cement complete all as specified and directed. |
| 41 | Note:- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri |