Tender For Special Repair To Building No Lt/15Ladies & Gents Bathroom & Ch/1 At Sessa Tst Camp And Drainage System, Rainwater Pipes, Roof Projections At 2 Dograof Age B/R And Age E/M Under Ge Tenga.; 1 Demolition of Brickwork or stone/ boulder masonry,built in cement mortar or cement lime mortar complete as specified. 2 M & L PCC 1:4:8 type D2, (using 40 mm graded stone aggregate) as in foundation , filling and mass concrete. 3 M & L PCC 1:3:6 type C2, (using 40 mm graded stone aggregate) as in surface channels, drains etc all as specified and directed. 4 M&L for PCC 1:3:6 type C-1(20 mm graded stone aggregate) precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in CM 1:6 etc complete all as specified and directed by Engr-in-Charge. 5 M & L for 15mm thick rendering in cement mortar 1:4 on brick or concrete surfaces with cement finishing the surfaces even & fair. 6 M&L for providing PCC (1:3:6) type C1 using (20mm graded crush stone aggregate) as in copings including necessary formwork complete all as specified and directed by Engr-in-Charge. 7 Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tracement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and directed by Engr-in-Charge. 8 Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for 9 M&L for 75 mm thick plain cement concrete type C1, 1:3:6, (40mm graded stone aggregate)as in plinth protection, finishing the top surfaces even and smooth W/O using extra cement. 10 M&L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture. 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and directed by Engr-in-Charge. 11 Taking down eaves gutters and rainwater pipes(any size or pattern), including all fittings,heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)complete all as specified and directed by Engr-in-Charge. 12 S&F Unplasticiscd PVC pipes of 200mm dia for RWP with proper PO finished joints with gaskete rubber ring & support clamps,bends complete all as specified and directed by Engr-in-Charge. 13 S&F PVC bends 200mm dia with access door complete all as specified and directed by Engr-in-Charge. 14 Dismantling Plain or corrugated steel sheeting(Aluminium sheet), any gauge, thickness, including Nainital orsimilarpattern roof coverings complete all as specified and directed by Engr-in-Charge. 15 M&L for Intregal water proofing compound over crumple joint provided with polymeric bituminious membrane with tiling the dried surface of slab laid in slop of 1:15 shall be painted with 1 coat of bituminious primer @ 0.40 ltr/sqm confirming to IS : 3384complete all as specified and directed by Engr-in-Charge. 16 M&L for Bituminious expansion joint filler board shall be PU foam type 25mm thick Rectangular shape complete all as specified and directed by Engr-in-Charge. 17 M&L for Dr Fixit wall Gap & crack filler(white) complete all as specified and directed by Engr-in-Charge. 18 M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm).Polymeric overlaps shall be minium 75mm and the end laps shall be minimum 100mm and sealing all overlap and joints for Parapets,membrane shall be taken to a height of min 60cm and then inserted inside the Parapet in a groove complete all as specified. 19 Refixing Plain, Aluminium sheeting,Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed)complete all as specified and directed by Engr-in-Charge. 20 S&F in repairs Galvanised mildsteelwire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed by Engr-in-Charge. 21 Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engr-in-Charge. 22 S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS-1161-1979 grade St.-240 complete all as specified and directed by Engr-in-Charge. 23 S&F Plate girder or single stanchions, builtup of one beam or channel section with flange plates, caps, bases.splices,angle brackets, cleats and other connectionscomplete all as specified and directed by Engr-in-Charge. 24 S&F Rooftrusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and directed by Engr-in-Charge. 25 M&L for applying two coat of synthetic Enamel paint on steel surfaces of any description, over 10cm in width or girth,not otherwise described over a coat of Red oxide zinc primer including preparation of surfaces complete all as specified and directed by Engr-in-Charge. 26 S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engr-in-Charge. 27 S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engr-in-Charge. 28 Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed by Engr-in-Charge. 29 Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed by Engr-in-Charge. 30 S&F in repairs Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)complete all as specified and directed by Engr-in-Charge. 31 Demolition floor, hearth or tiling including cement mortar bedding (but not backing)), removing serviceable tiles to store and rubbish off the premises all as specified. 32 M&L for 15 mm thick screed bed in CM 1:4 for laying floor tiles . 33 M&L for light shadeVirified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. complete all as specified and directed. 34 M&L for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding .38 sqm, in floorsurfaces etcset and jointed in neat cement slurry and pointed in white/coloured cement to match the shade. 35 M&L for Non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding .38 sqm, in floorsurfaces etcset and jointed in neat cement slurry and pointed in white/coloured cement to match the shade. 36 M & L for Glazed coloured ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match. 37 Demolition of cement concrete (unreinforced) in ground floors and paving’s not exc 15 cm thickness (below or above ground level) 38 M & L 75 mm thick Cement concrete type D2 1:4:8 (40mm graded aggregate) as in sub base, including form work complete all as specified and directed by Engineer-in-Charge 39 M&Lfor 20mm thick screed bed in CM 1:4 for aying floor tiles 40 M&L Chequered cement concrete tiles 20cmx20cmx25mm thick with grey cement and pigment, set jointed and pointed in neat cement slurry in floors completed all as specified and directed by Engr-in-Charge. 41 Demolition of cement concrete (reinforced) in any description not exc 15 cm thickness (below or above ground level) 42 M&L forre-inforced cement concrete 1:2:4 type B-1 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed. 43 M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia orsecuring with clips complete all as specified and directed. 44 S&F Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), rough finished flat surfacecomplete all as specified and directed. 45 Demolition of stone slabs or tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etc 46 M&L20 mm thick granite (of any type) work (table rubbed and polished) in cooking platforms in CM 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite all as specified. 47 S&F posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling,boltingor riveting, etc., and similar work conforming to Fe-290 Gde E-165 all specified and directed. 48 M&L for precast cement concrete solid building blocks (1:3:6), type C-1, 10 cm thick (with plain or interlocking joints as directed) setting in cement mortar (1:4), complete, laying inner side of wall. 49 Taking down cement plaster on brick, concrete stone surfaces etc including raking out joints, hacking for key, scrubbing down with water etc. 50 M & L 10 mm thick rendering in cement mortar 1:6 on brick or concrete surfaces finished even & smooth without using extra cement 51 Material and labour for preparation of newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of chalk whitening primer. 52 Material and labour for preparation of old distempered surface of walls including washing down and stopping of distempered surfaces and applying one coat of distempered oil emulsion all as specified and directed. 53 Material and labour Preparing newlyplastered wall surfaces and applying Two coats of cement base paint on wall surfaces over one coat of alkali resistance primer 54 Material and labour for complete removal of existing treatment and appling two coat of cement base paint over one coat of alkali resistance primer complete all as specified 55 Dismantling of wall and ceiling board or insulation boards/slabs/blanckets/any thickness including cover fillets 56 S&F for providing 4 mm thick E Board in ceiling with galvanised iron snap frame of T section 24 x 38 x0.70 mm wall/ceiling angle 25 x 25 x 0.35mm thick and hanging with 4 mm GI wire all fixed arrangement will be done as per manufacturer instruction incl of oil bound distemper anirected one coat of white wash complete all as specified and directed. 57 Material and labour for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified and directed. 58 Taking down chowkats or frames with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exc 4 Sqm. 59 S&F solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying and fixing in opening as per specification and drawing. 60 S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frameshall be covered with heat moulded plain colour PVC C channelhaving a PVC sheet strip of 20mm width stuckinside with solventcementfor stiles and plain colour PVC sheets for top rail, lock & bottom rail on either side & as gap insert for top rail & bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement supplying & fixing in the frameat siteas per specification & drawing. 61 S & F 100mm size mild steel butt hinges medium weight cold rolled and fixed. 62 S& F Aluminium anodised barrel tower bolts150mm long of extruded section and fixed 63 S & F 150mm size extruded aluminium alloy handles, fabricated type anodised 64 S & F aluminium alloy, anodised, sliding door bolts 300mm size with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed 65 Dismantling of water tanks exc250 ltrs & n. exc 500 ltrs capacity and removing to store. 66 S & F PVC water storage tanks of 500 ltrs capacity rotational moulded (multi layered cylindrical vertical with closed top) hoisted and fixed in position all as specified 67 S&F PVC (SWR) pipes single socketed 110 mm bore in any length with rubber ring joints fixed to walls 68 S&F PVC (SWR) pipes single socketed 75 mm bore in any length with rubber ring joints fixed to walls 69 S&F PVC (SWR) junction single, (single T) equal or unequal with access door110mm bore. 70 S&F PVC (SWR) bends any radius, 110mm bore withaccess door. 71 S&F PVC (SWR) bends any radius,75 mm bore withaccess door. 72 S&F PVC (SWR) junction single, (single T) equal or unequal with access door75mm bore. 73 S&F PVC (SWR) vent cowl 110 mm bore 74 S&F PVC (SWR) couplers 110mm bore. 75 S&F PVC (SWR) floor trap, 75mm dia outlet, plain with grating incl jointing with solvent cement. 76 S & Fball brass valves, high pressure, with polyethene float and flynut complete screwed for iron pipe of40mm dia all as specified 77 Taking up or down 15 mm boresteel water tubingand connections including clfor refixing or removal to store 78 S&F 15mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls/ceilings or laid in trenches. 79 Taking up or down 20 mm boresteel water tubingand connections including clfor refixing or removal to store 80 S&F 20mm bore steel water tubes, medium grade, galvanised with all fittings and fixed complete to walls/ceilings or laid in trenches. 81 S & F in repair looking mirror 600 mm x 450 mm bevelled edge mirror or selected quality glass, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers 82 S&Fvitreous china wash hand basin white flat back of size 550mmx400 mmincluding cutting for and pinning in end of brackets,32 mm waste fittings,brass chromium plated for glazed ware sinks,basins etc.with long screwed shanks and fly nuts flange end bedded in red lead cement and other end fixed.and flush pipe of polytethylene of low or high density or PVC 32 mm dia 83 S&F PVC connections 15 mm size with PTMT nuts of length 450 mm. 84 S & F in repair vitreous china wash down water closet pan (Squatt pattern) white inclPVC (SWR) 110mmP’ trap and WC connector (exclusing fixing bolts, flushing cistern and flush pipe) complete all as specified. 85 S & F vitreous china wash down water closet pan (pedastal pattern) white inclPVC (SWR) 110mmP’ trap and WC connector (exclusing fixing bolts, flushing cistern and flush pipe) 86 S&F in rep Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. 87 S&F10litres PVC,Syphonic action type, Flushing cistern low level ,white with inlet ball valve float chain and pull and brackets complete 88 S&F in repair 20 mm bore gun metal globe or gate valve with ironwheel head screwed both ends for iron pipe 89 S & F in repairs chromium plated fancy type 15mm dia bib tap, cast copper alloy with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule complete all as specifed. 90 S&F 15mm stop valves alloy,screwed down , high pressure,with crutch or butterfly handle,screwed both ends for iron pipe but fancy type,chromium plated 91 Supply and fix in rep 15mm Pillar taps , cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly-nuts, screwed for iron pipe and fixedcomplete all as specified and directed. 92 Demolition and breaking up drain pipes 100mm SWG pipe, set in cement morter complete all as specified and directed. 93 Material and labour for providing PCC (1:3:6) type C-2 as in concrete bed to drain pipes including packing under and haunching against the sides of pipes of bore 100mm on after they are laid and tested complete all as specified and directed.. 94 Material and labour for Salt glased stone ware drain pipe 100 mm dia grade A laid in trenches and jointed in cement mortar 1:1 complete all as specified and directed. 95 M&L for construction of septic tank for 10 users, in hard/ dense soil, foundation in PCC 1:3:6 type C-1, stone masonary wall in CM 1:4, RCC slab cover including RCC precast manhole cover having 6mm plate embedded all around/ fibre reinforced cover with angle iron frame vent shaft and sludge chamber complete all as specified in ED-2007 and as directed. 96 Material & Labour for Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast,Prestoteak), including PVC insulated and unsheathed (FRLSH) single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed. 97 All as per item No. 96 here in before but for one 3 pin socket outlet 5 Amps three pin controlled by one switch on independent board complete all as specifieddirected. 98 S&FSocket outlet 2 in 1, 3 pin, 5amp flush type all as specified and directed . 99 Supply & fixing switch piano flush type (ISI marked), single pole, one way 5 Amp, 240 Volts complete all as specified & directed. 100 Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. 101 S&F LED bulkhead fitting 10 watt (Endura Ruby) with all accessories and including connenting up with twin core twisted with flexible copper conductor cable with suitable size of 230 volts , 50 hz complete all as spicified and directed. 102 Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tub light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed. 103 Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm 104 Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm ,two to three terminals complete all as specified & directed. 105 S&FDB double door MCB DB 8 way sheet phospetised powder painted with 200 Amps rated bus bar 230 Volts neutral link, IP 43 protection double doortype fixed on wall duly grouted in solid block or wooden board complete all as specified and as directed 106 S&F MCB SPN having braking capacity 10KA, 32 Amps, 240 Vcomplete all as specified and directed. 107 S&F MCB SPN having braking capacity 10KA, 6 to 32 Amps, 240 Vcomplete all as specified and directed. 108 Excavationin trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out hard & densile soil complete all as specified and as directed. 109 Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed. 110 Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed. 111 M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particalsin trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shallbe measured 18 cm after punning. 112 Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm,factory madeof specified make , complete all as specified and directed. 113 S&F in replacement of 1100 Volts grade heavy duty ISI marked cable XLPE insulatedmulti stranded aluminium conductor16 Smm 2 core. Complete all as specified and directed by Engr In Charge. 114 Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for liftingmade out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge. 115 Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc) 116 Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC. 117 Making holes of suitable size in the existing wall for fixing of exhaust fan and making good the disturbed surfaces all as directed by Engineer-in-Charge