| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 2 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 4 | 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 5 | 12 mm cement plaster finished with a floating coat of neat cement of mix : |
| 6 | 1:3 (1 cement: 3 fine sand) |
| 7 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. |
| 8 | Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 9 | Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade(0.10 kg of hardener and 0.20 kg of resin per kg), including filling/grouting and finishing complete as per direction of Engineer-in-charge. |
| 10 | Size of Tile 600x600 mm |
| 11 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required : |
| 12 | W.C. pan with ISI marked white solid plastic seat and lid |
| 13 | Providing & setting PVC floor trap with gratings. 100mm inlet & 75 mm outlet. |
| 14 | Dismantling EWC pan & refixing the same after tilework in floors. |
| 15 | Dismantling half brick parapet over sunshades of windows(1.5x0.70 )m and finishing the edges with CM 1:3 mix complete in all the floors |
| 16 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 17 | 75 mm diameter |
| 18 | 110 mm diameter |
| 19 | Supplying & fixing PVC fittings |
| 20 | Single tee with door 75x75x75 mm |
| 21 | Single tee with door 110x110x110 mm |
| 22 | 75 mm pipe clip |
| 23 | 110 mm pipe clip |
| 24 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 25 | Semi rigid pipe 32 mm dia |
| 26 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall |
| 27 | 20 mm nominal outer dia. Pipes. |
| 28 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 29 | Renewing glass panes, with wooden fillets wherever necessary: |
| 30 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 31 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. |
| 32 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 33 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 34 | 15 mm nominal bore, 122 mm long. Weighing not less than 99 gms. |
| 35 | Providing and fixing PTMT stop cock of approved quality and colour. |
| 36 | 15 mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 37 | Providing and fixing PTMT pillar cock of approved quality and colour . |
| 38 | 15mm nominal bore, 125 mm long foam flow. Weighing not less than 120 gms. |
| 39 | Providing and fixing uplasticised PVC connection pipe with brass unions : |
| 40 | 15 mm nominal bore |
| 41 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 42 | One coat. |
| 43 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 44 | One or more coats on old work. |
| 45 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 46 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). |