Repair Maintenance Of Electrical And Mechanical Services At The Icmr -Nirdh & Ds Building For The Financial Year 2025-26. SH:-1 (electrical installation & Fans i/c compound light)-1 Operation & routine maintenance of internal & external electrical installation having light point, exhaust fan point, call bell point, power plug, AC outlet, fittings, fans, distribution boards, Floor panel, control panel, i/c street light, compound light installed in NIMS building i/c operation of all drinking water pump sets on all working days excluding sundays & Holidays By providing staff as per terms & conditions etc complete as reqd. RENOVATION/ALTERATION WORK 2 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. 2.1 Group C 3 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required 3.1 Group C 4 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 4.2 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 5 Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 5.1 3 x 1.5 sq. mm 5.2 3 x 4 sq. mm 5.3 3 x 6 sq. mm 6 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6.1 15/16 A switch 6.2 6 pin 15/16 A socket outlet 6.3 Telephone socket outlet 6.4 Data socket outlet 7 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 7.1 1 or 2 Module (75mmX75mm) 7.2 3 Module (100mmX75mm) 7.3 6 Module (200mmX75mm) 7.4 12 Module (200mmX150mm) 8 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 8.1 Single pole 9 Supplying and fixing following rating, four pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 9.1 63 A 10 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V C curve DP MCB complete with connections, testing 11 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 11.1 100 A, 16 KA,TPMCCB 11.2 200 A, 25 KA,TPMCCB 12 SITC of 400mm sweep wall mounted fan in plastic material having three speed settings with oscillation and tilt mechanisam, pull cord, aerodynamically design and balanced blades, rated voltage 220/440 Volts, 50 Hz, 1-ph AC having Class E motor insulation and minimum 1300 RPM i/c wiring complete with 1.5 sqmm FR PVC insulated copper conductor, single core cable etc. complete as reqd. at site. 13 SITC of following types heavy duty propeller tube exhaust fan at following locations having dynamically balanced impellers & vibration free operation, 900/960 RPM, pre lubricated double ball bearing rated voltage 220/240 Volts, 50 Hz, 1- ph AC having Class E motor insulation i/c wiring complete with 1.5 sqmm FR PVC insulated copper conductor, single core cable etc complete as required at site. 13.1 300 mm sweep 14 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374- 2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 14.1 1200mm, service value 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 15 Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 15.1 36 watt 16 Supplying, Installation, Testing & Commissioning LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material PMMA and prismatic diffuser and construction as per 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.0.95, IP20, >80, UGR (Unified Glare Rating) < 19, Flicker (flicker should be below 5%), life time (LED, Driver electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) Maximum power consumption should not more than specified rating and Fixture shall be confirming relevant BIS standards. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required Minimum 5 year OEM warranty. System lumen efficacy 105 and <120 lm/Watt output. LM79 & LM80 report and all testing required for LED fixtures as per shall be submitted. Shape size and CCT shall be approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim 16.1 18 watt 17 Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.0.95, IP- 66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). 17.1 72 watt 18 Supply of following capacity Plug Tops for cable/wire connections etc complete as required. 18.1 3 pin 5/6 Amp 18.2 3 pin 15/20 Amp 19 Less credit for old dismentled materials 19.1 Switch / Socket 19.2 MCBs 19.3 MCCB 19.4 Ceiling Fans 19.5 Wall Fans 19.6 Exhaust Fans 19.7 LED Fittings SH:- 2 (Water Supply) 20 Rewinding of induction motor of following capacity with superior quality insulated submersible copper winding wire i/c dismantling the exiting burnt winding & testing, commissioning etc. complete as reqd. Burnout wire will be retained by agency. 20.1 3 Phase, 415 V, 5 HP 21 Repairing and servicing of motor of following capacity i/c replacement of damage parts i.e. Rotor sleeve, Bearing bush, Thrust counter, Thrust disc i/c testing etc. complete as reqd. 21.1 3 Phase, 415 V, 5 HP 22 Repairing & servicing of monoblock pump following capacity i/c replacements of following damage parts i.e. Pump shaft Re-metalling, Grinding & balancing, impeller repairing balancing, wear ring, mechanical seal, chuck & testing etc. complete as reqd. 22.1 3 Phase, 415 V, 5 HP 23 Supplying and replacement of following accessories in existing starter panel connections, testing, commissioning etc complete as reqd. 23.1 Power contactor MNX 12 23.2 Overload relay type MN 2 (Range - 4.5 to 7.5) 23.3 Star delta timer ST 100 23.4 Digital voltmeter 23.5 Digital Ammeter 23.6 Single phase preventer (VSP 2) 24 Less credit for old dismentled materials 24.1 Power contactor MNX 12 24.2 Overload relay type MN 2 (Range - 4.5 to 7.5) 24.3 Star delta timer ST 100 24.4 Digital voltmeter 24.5 Digital Ammeter 24.6 Single phase preventer (VSP 2) SH:- 3 (Lifts) A OPERATION 25 Providing daily lift monitoring & rescue operation & services in emergency for lift in general shift at NIMS excluding Sunday & Holidays (for 1 Nos. lifts) - 1 Job B COMPREHENSIVE MAINTENANCE 26 Comprehensive maintenance of OTIS make 6 passenger capacity lifts installed at NIMS building i/c controllers working on 415 volt, 3 phase, 50Hz AC supply serving of following floor i/c accessories i.e. ARD as per terms & conditions. 26.1 a) GF to 3rd floor (Lift Machine No. L006048) 27 Supplying and replacement of following materials in existing OTIS make 6 passenger lift complete including testing commisioning etc as required. i) Control box ii) DOOR PROTECTION w/HARN CABLE iii) MOUNTING KIT-DOOR PROTECT[CLD] iv) SIGHT GUARD FOR CAR DOOR SH:- 4 (WTAC/STAC & DUCTABLE UNITS) 28 Operation, Repair, servicing, routing maintenance, Preventing maintenance & breakdown maintenance for the AC Equipments/Units installed in ICMR building by deputing the following qualified & experienced Staff from 9 AM to 5.30 PM (3 Visit Per Week) excluding Sunday & Holidays i/c replacement of defective parts/items (Note:- items will be paid seprately) etc. complete as reqrd. 29 Servicing of STAC/WTAC/Casette unit of 1.5 TR / 2 TR , lubricant with oil in the blower motor and wash the cooling coil, condenser fins and complete body with the water pressure machine and suitable detergent/ vanee clean chemical and Removing the minor fault like fan alignment of the blower motor, water leakage, testing commissioning complete as reqd. 30 Supplying & replacement of following capacity reciprocating / rottery type hermetically sealed compressor complete in the existing WTAC / STAC unit i/c repairing / rejoining of copper pipes, Supplying & charging of R-22 refrigerant gas, replacement of capillary tube & strainer, pressure testing, vaccumising, testing etc. complete as reqd i/c dismentalling and less credit for old dismental material. Emesion Control / LG / Voltas as per existing make & model) 30.1 1.5 TR capacity 30.2 2 TR capacity 31 Supplying & Charging of R-410 A / R-32 refrigerant gas in existing following capacity (1.5 / 2 TR) WTAC / STAC unit i/c replacement of capillary tube & strainer, pressure testing, vaccumising, testing etc. complete as reqd. 32 Supplying & Charging of R-22 refrigerant gas in existing 1.5/2 TR capacity WTAC/STAC unit i/c replacement of capillary tube & strainer, pressure testing, vaccumising, testing etc. complete as reqd. 33 Supply, Installation, testing and commisioning including vaccumiazation and Nitrogen testing testing off following nominal sizes of soft/hard drawn copper refrigerant piping for split AC, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing i/c accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastrometric nitrille rubber tubular sleeves sections of specified thickness as given below for Suction and Liquidlines, all accessories as per specifications etc. as required i/c dismentalling and less credit for old dismental material. 33.1 6.4 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation 33.2 15.86 mm dia (OD) (Softdrawn) with tube thickness 1.2 mm with 19 mm thick insulation 34 Repairing of PCB card of WTAC/split type AC unit having following capacity after dismantaling the defective card from AC unit & refixing the same i/c connections of electrical wires / cables & thimbles connection, testing & commissioning etc. complete as required. 34.1 1.5 TR Non-Inverter 34.2 2 TR Non-Inverter 34.3 1.5/2 TR Inverter 35 Supply and replacement of PCB card of WTAC/split type AC unit having following capacity i/c dismantaling of defective PCB card from unit & fixing of new one, connection, testing & commissioning complete i/c buyback the same etc as required. 35.1 1.5 TR Non-Inverter 35.2 2 TR Non-Inverter 35.3 1.5/2 TR Inverter 36 Supplying and laying of 2.5 sq.mm. X 3 core PVC insulated overall PVC sheated round copper conductor flexible cable (ISI marked) in existing 2 TR. capacity STAC unit etc. as per requirement at site. 37 Replacement of following material for WTAC / split units: and when as reqd. 37.1 Running capacitor 37.1.1 2.5 MFD 37.1.2 6 MFD 37.1.3 50 MFD 38 Comprehensive maintenance of carrier make 7 Nos. Ductable units of total capacity 28 TR installed at NIMS building.