Tender for Development Of Ramgiri Pahadi Badgaon Udaipur As An Oxygen Hub Tourist Destination At Udaipur Rajasthan. 5401-- 1 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 2 Excavation in Hilly Area in Ordinary Rock by Mechanical Meansnot Requiring Blasting. (Excavation in hilly area in ordinary rocknot requiring ballasting by mechanical means including cutting andtrimming of slopes and disposal of cut material with all lift and leadupto 1000 metres ) 3 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including gettingout the excavated soil anddisposal of surplus excavated soil as directed with a lead in a 50 meter including stacking of useful material if available :Ordinary rock 4 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains not exceeding 1.5 m in width or 10 sqm on plan including dressing of sides and ramming of bottoms lift upto 1.5 m, including gettingout the excavated soil anddisposal of surplus excavated soil as directed with a lead in a 50 meter including stacking of useful material if available : Hard rock (requiring blasting) useful material 30% 5 Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. 6 Random rubble dry stone Kharanja under floor. 7 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 40mm nominal size). 8 Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 9 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcementfor Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M25 grade Design Mix by usingmin 410 kg of cement per Cum . 10 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 11 Providing and laying in position Ready mix concrete manufactured in fullyautomatic Batching Plant andtransported to site intransit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer in charge.All works upto floor V floor. Design Mix by usingM-25 grade concrete by using min 410 kg of cement per Cum 12 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. 13 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 14 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Columns, pillars, posts and struts etc. 15 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.(Original producers who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) 16 Providing and fixing stainless steel railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). Grade 304 17 Providing and fixing steel gate, grating , and grills made ofangles, tees, square bars, flats,or black pipe with holdfast andfittings complete as per design and drawing including cuttingwelding and fabrication with priming coat of red oxide 18 Extra if square,rectangular hollow tubelar sections are used or grill made by flats only 19 Unbranded Modular Tensile Structure, Size 5X5 NA (Moduler cantiliwer Gazebo) Specications :- Governing Standards European Norms,Sizes 5X5, Column Only Febric, Structure Only Febric,Projection Radius Only Febric, Roof & Side Covers 650 Or higher gsm, Water Proof & Fire Retardant of M2/B1 International, Fire Rating Yes, Certications/Approval European Norms 20 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). 21 Random Rubble stone masonry with hard stone in superstructure above plinth level and upto five level above 30cm. thick walls in : Cement Mortar 1:4 ( 1-Cement : 4-Sand). 22 Add extra for facing as per design and detailed specifications including additional cost of stonesCourse rubble facing First sort. 23 Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75 Cement mortar 1 : 3 (1 cement : 3 coarse sand) 24 Add extra providingand placing in position 2 Nos. ,6mm Ø M.S. barat every thirdcourse of half brick masonry . 25 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20mm thick . 26 6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) 27 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 28 Applying priming coat : With ready mix pink or gray primer of approved brand and manufacture on wood work hard and soft wood. 29 Applying one coat of Cement primer of approved brand and manufacture on wall surface including all scaffolding: 30 Finishing with Epoxy paint (two or more coats) at all locationsprepared and applied as per manufacturers specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work 31 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect 32 Painting exterior surface of Wall with 100% acrylic exterior paint of approved brand and manufacture to give an even shade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision New Work 33 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade :Two or more coats on new work 34 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm 35 Extra for Mirror polishing on terrazzo/Kota stone work where ever required to give high gloss finish complete. 36 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm 37 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete. Jhunjhunu/Jalore (Red/Choclate/Black/Pink Colour)Above 3601 Cm2 Slabs 38 Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite/Kota Stone Work Full Edge moulding 39 Extra in marble/other flooring work for upto 50 mm wide strip of Green/White/ Jaisalmer stone in flooring work as per direction of Engineer in Charge 40 Providing non slip grooves to granite/ kota stone flooring, counters, vanities etc. using groove cutter V type including machine polishing to groove to give high gloss finish etc. complete as per design approved by engineer in charge 41 Extra for fixing marble /granite stone over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete 42 P & F 1st qualityHeavy Duty Vitrified Polished Digital tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. Size 600mm x 600mm 43 P & F 1st quality Heavy Duty Vitrified glazed MAT tiles on floor, skirting and steps etc.in different sizes (thickness minimum 10mm) with water absortion less than or equal 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20 mm thick CM 1: 4 including grounting the joints with white cement and matching pigment etc complete. size600 mm X 600 mm 44 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete 45 Providing and fixing 1st quality MAT & GLOSSY finishedceramic tile confirming to IS : 13755 and IS : 15622 coloursuch as white, grey, ivory, fume red brown, light green, lightblue and other light shades in floors, steps, pillars etc. laid on abed of neat cement slurry finished with flush pointing in thewhite cement mixed with pigment to match the shade of thetile complete (including the cost of cement mortar bed 1:4)Size 600mm x 600mm 46 Providing and fixingaluminum workfor doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285,fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and thedirections of Engineer- in – charge .(Glazing and paneling to be paid for separately). For fixed portion Powder coating aluminum( minimum thickness of powder coating 50 micron) 47 For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately).Powder coating aluminum( minimum thickness of powder coating 50 micron) 48 Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basicitem.) 49 With float glass panes of 5.0 mm thickness ( weight not less than 13.50 kg/sqm) 50 With float glass panes of 8 mm thickness 51 Extra for providing toughened glass panes instead of ordinaryfloat glass panes in doors, windows and clerestory windowshutters. (Area of opening for glass panes excluding portioninside rebate shall be measured). 52 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Prelaminated particle board with decorative lamination on both sides. 53 Providing and fixing 12 mm thick prelaminated three layer medium density (exterior grade ) particle board Grade I, Type II conforming to IS : 12823 bonded formaldehyde synthetic resin ,of approved brand and manufacture in paneling fixed in aluminium doors ,windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and direction of engineer-in-charge. Prelaminated particle board with decorative lamination on both sides. 54 Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm andopening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at theends and middle joints respectively complete in all respect as per direction of engineer in charge.Powder coating aluminum ( minimum thickness of powder coating50 micron) 55 S&f fixed wire gauge of stainless steel of 14 mesh x 24 gauge to the aluminium window by Aluminium beading 20x3mm with suitable screws not exceeding 150mm distance at all heights with all lead and lift with scafolding 56 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 35 mm thick . Decorative teak veneer both side 57 Grading roof for water proofing treatment withwater proffing compoundCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 58 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 59 Making khurras 450 x 450mm with average minimum thickness 50mm cement concrete 1 : 2:4 over P.V.C. Sheet 1 Mtr. x 1 Mtr. x 40micron finished with 12mm cement plaster 1 : 3 and one coat of neat cement, rounding edges and making and finishing the out let complete. 60 Providing and laying 25 to 35 mm size glazed tiles thickness 5mm pieces for roof treatment having colour and shade as approved by the engineer in charge over 25 mm thick layer of cement mortar mix 1:4 prepared with 1% solution of water proof compound with application of cement slurry including finishing of joints with white cement and curing etc. complete in all respect. washing with acid. with all lead and lift. 61 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 62 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion). 63 Supplying chemical emulsionin sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% 64 Providing and fixing Stone jali 50mm thick Red/Pink sand stone as per ornamental designto fixed with white cement/epoxy mortar including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade. 65 Supply and Installation of WALL – PREFABRICATED INSULATED CEMENT FACE PANEL: Factory-readymade structural reinforced insulated wall panel of thickness mentioned below. Panel shall be made of 6mm (+/-0.6mm) thick asbestos-free fiber cement sheet/ Cement bonded particle board as per IS:14276:1995 on both sides of rigid PUR insulation. The wall panel shall be vertically joined together with adjacent panel by biscuit joints lengthwise with suitable construction adhesive. Joining member (biscuit) shall be made of approx 12mm thick cement sheet /Cement bonded particle board as per IS:14276:1995. Panels may have optional provision for inbuilt electrical conduit running lengthwise at vertical center of specified panels. Both vertical lengthwise sides of panels must have full length MS tubes of min 1.0mm thickness for better structural strength.The final panel surface must be free from undulations. The Insulating core shall be self-extinguishing DIN 4102,Class B3 fire retardant class rigid PUR with thermal conductivity of 0.025 W/mK and with density of 40kg/m3 (+/-2kg) suitable for temperature range of -30 degree C to +80 degree C. The panel must be made using glue-free high pressure hot pressing self-bonding method and shall be free from major surface undulations.Thickness 75mm (+/- 2mm) 66 Supply and Installation of ROOF – PREFABRICATED INSULATED PPGL FACE PANEL: Roof: Insulated sandwich panels for roof of total thickness mentioned below exclusive of crest height of top corrugation. Panel shall be made of 0.50mm (+/-0.04mm) thick pre coated metal sheet on both sides of rigid polyurethane insulation. The top external facing metal sheet shall have corrugated shape with crest. The trapezoidal shape crowns/crest height should not be less than 30mm. The pre-coated metal sheet shall be PPGL (Pre Painted Galvalume Sheet with AZ coating) sheet having SDP (Super Durable Polyester) colour coat of 18 micron (min). The bottom sheet must have tongue and groove type flange (U shape) of 8mm x 8mm on groove side and 8mm x 12mm on tongue side. Flange must be on lengthwise sides for joining adjacent panels. Panels bottom side PPGL sheet must also be pre-strengthened by full lengthwise stiffening with semi-circular beading of 12mm width & 3 to 4mm depth at 240 (+/-5) mm pitch. The top corrugated sheet must have at-least one open crown/crest for overlapping adjacent panel widthwise. Similarly the top corrugated sheet must have suitable open extension of min 6” on bottom widthwise side of panel for overlapping further panels joined lengthwise also. The insulation core shall be self-extinguishing DIN 4102,Class B3 fire retardant class rigid PUR with thermal conductivity of 0.025 W/mK and with initial density of 40kg/m3 (+/-2kg) suitable for temperature range of -30 degree C to +80 degree C. The panel must be made using glue-free high pressure hot pressing self-bonding method. PPGL sheet on both sides of panel shall have a min15 micron protective plastic guard film to avoid scratches during transportation. Thickness 105mm (+/- 2mm) 67 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1 : 4 (1 cement : 4 coarse sand) 68 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 12mm thick . 69 Providing and fixing pressed steel door frames confirming to IS 4351 manufactured from commercial mild steel sheet of 1.25 mm thickness including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechanical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applyinga coat of approved steel primer after pre-treatment of the surface including filling with CC 1:2:4(M15 grade) complete as directed by Engineer-in-charge :Profile E 70 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of:Ist course of applying cement slurry @ 4.4 Kg/sum mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. IInd course of 20mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water. proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.. IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg per sqm. of area. IVth course of 400 micron thick PVC sheet .(Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen@ 1.7 Kg/sqm.) 71 Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) :Flush / Ruled/ Struck or weathered pointing. 72 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 73 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.M15 grade Nominal Mix1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). 74 Extra in marble/other flooring work for upto 50 mm wide strip of Green/White/ Jaisalmer stone in flooring work as per direction of Engineer in Charge 75 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal of formwork for upto floor five level for :Walls (any thickness) including attached pilasters, buttressesplinthandstring course. 76 Supplying and fixing ashlar sills, jambs, skirting, steps etc. rough dressed: (B) Upto 15 cm thick Red Ashlar 77 Fine grinded Gangsaw cut 30-35 mm thick stone flooring over 20 mm (average) thick base of cement mortar 1:4 (1 cement :4 coarse sand) jointed grey cement slurry mixed with pigment to match the shade of stone complete as per design drawing and instruction of EI. Mandana stone 78 Stone work (machine cut edges) for Wall cladding/ Veneering work up to 10m height with 20 to 30 mm thick Red Sand Stone (Karauli ) and backing filled with a grout of 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade :(To be secured to the backing by means of cramps which shall be paid separately) Exposed face machine cut 79 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand) including making the necessary chases. 80 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand) including making the necessary chases in stone and holes in walls wherever required. 81 Stone work in plain ashlar in super structure upto floor five level incement mortar 1:6 (1 cement : 6 coarse sand) including pointing with cement mortar 1:2 (1 whitecement : 2 stone dust) with an admixture of pigment matching the stone shade : Both face dressed 82 Providing & Fixing Red Sand Stone Bench size (2.40mtr.x0.60mtr. & 0.60mtr Height) & SS hollow Pipe with MS Chain all Complete as per site in-charge. 83 Providing and Laying White & Golden 3 Feet Height Portable Fibrecraft Multicolor Standing Rabbit Dustbin all complete as per site-inchrge 84 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor:Size 580x440mm. 85 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556mark). Of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball, (IS: 1703 mark) complete including cutting and making good the wall: PVC with PVCbend as per IS : 7231 . 86 P & F European type white glazed vitreous china 1st quality Double syphonic W.C (IS :2556 Mark) with P or S trap including cutting and making good the wall and floor 87 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : 88 Size 550 mm x 400 mm 89 Size 610 mm x 510 mm 90 Add extra for using 25mm GI waste pipe instead of PVC waste pipe 91 P & F Bevelled edge Mirror/mirror with teak wood lipping around of special glass of approved make as per direction of Engineer-in-charge complete with 6mm thick commercial ply base fixed to wooden screws & washers.other Sizes 92 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete. Flat Back Large or Half stall size 610 x 400 x 80mm 93 P & F Automatic Flushing Cistern of first quality (IS : 774 mark) of approved make fitting, siphon with copper tube, C.I. brackets complete including cutting and making good the wall. WVC (as per IS : 2556) 10 litres. 94 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:C.P. Brass bib cock,15mm nominal bore. 95 Makrana `Adanga` or Raj Nagar 1St Quality White or Andhi Indo-Italian marble. 96 P&FC.P.brassUrinalFlushPipeset complete with flanged brackets ofapproved make. 97 For 2 Uninal 98 For 1 Urinal 99 P & F 15 mm. Dia Connection Pipe of approved quality/make PVC pipe withC.P. Brass nuts upto length, 450mm 100 P & F C.P. Health Faucet with 1Mtr. Long Tube & Hook of approved make and heavy as per direction of Enginner-inCharge 101 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked) 102 Providing & Fixing Premium quality Bottle trap internal portion 32mm, size 250mm long wall connection pipe & wall flangeas per approved by Engineer in Charge. 103 P & F Liquid Soap Container with brackets complete of approved make: C.P. brass 104 P & F Towel Rail or Ring of approved quality/make: C.P. brass Towel Rail elbow type with concealed screws size 450mm (Heavy duty). 105 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 106 160 mm dia 107 75mm dia 108 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1 metre spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall) 109 25 mm nominal size 110 32mm nominal size 111 40 mm nominal size 112 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes (IS 15778 : 2007 code) having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Concealed work including cutting chases and making good the walls etc.,) 113 15 mm nominal size 114 20mm nominal size 115 25 mm nominal size 116 P & F Grating of approved quality/make: (-do-) Square 150 x 150 x 8mm. (Anti Cockroach) 117 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make 110 mm 118 Providing and Fixing Unplasticized Poly Vinyl Chloride (UPVC) SWR Pipes fittings type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality /make. 119 Coupler 110mm dia 120 Bend 87.5 Dg. 110mm dia 121 Bend 45 Dg. 110mm dia 122 Door Bend 87.5 Dg. 110mm dia 123 Single Y 110mm dia 124 Single Y with Door 110mm dia 125 Pipe Clip 110mm dia 126 P & F Grating of approved quality/make: Stainless Steel Sheet size 125mm dia. 127 P & F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted, 40 mm C.P. waste coupling, C.P. Brass chain with rubber plug, 40 mm G.I. waste pipe up-to floor level complete including cutting and making good the wall & floor : 1.0 mm thick stainless steel AISI -304 & IS 13983-1994kitchen sink of approved make as per Engineer-in-chargewith large waste coupling.24 x 18 x 820x16x8 128 P& F waste Pipe with all fittingP.V.C. with C.P. nut 40 mm dia 129 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:1000litres capacity. 130 Construction of septic Tank in all types of soil with 40 Cm .thick masonry in CM 1:6, 15 Cm thick C.C bed of 1:5:10, M-15 gradeC.C floor &RCC slab covering with M15 grade c.c. floor,50 mm thick stone slab partition walls, 20 mm thick plaster in CM 1:6 finished with neat floating cement, 4 Nos stone foot rests of approved design ,two No. 450 mm dia each Ferro cementcover with frame, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr:- Size 400 x140x150 cm.(for 50 users)with 115 mm thick RCC (M-20) slab with Tor steel reinforcement 10mm ϕ @15 cm c/c bothways including shuttering complete in all respect. 131 Construction of soakage well in all type of soil with 300 mm thick dry masonry, top and bottom 300 mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1 : 3, Ralthal, Kharanja, 40 mm thick M-15 grade C.C flooring , earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr.: Size 300 Cm. dia outside & 300 Cm. depth . 132 Supply and installation of Bio digester toilet system tank. Tank is made of F.R.P. (Fiber Reinforced plastic) with 7 mm thick sheet with in inocolum (bacteria) A spefific high graded bacteria used to convert the facial matter into methane and water of Ph value 6 to 9 only. (Fxcluding earth work & concreter base) Tank capacity (S) user LWH (mass) users price 2125 Ltrs. 2000 * 1500 * 725mm , 50 users 133 Pressure Send Filter FiberGlass Top Mount Sand Filter with clamp lock valve Filter Dia 700 MM ow 10 m3/hr Make: Aquapac , Emaux, Pool buddy 134 Pump Capacity - 5hp, 3 Phase , water proof Standerd , Ring lock Design , S.S.316 Salt &Mechanical Seal Make: Aquapac , Emaux, Pool buddy 135 Filter Media 136 Circle round fountain as per drawing Stone / FRP 137 Pipes and Fittings for fountain & Pump Room Complete Pipe And fitting ( NRV, Ball valve ,fitting , pipe ) in UPVCmake Supreme/Finolex All valves Zoloto/Audco L& T 138 Control Panel All the components used will be of desired quality like L&T , Havells Schnider or Equivilant oure box will be locally fabricated Made in India 139 Under WaterLED Light 18w , 12v 140 Wiring & Conduting 141 Power Controller for Light 142 Drawing Commisioning & Transportation 143 Pressure Send Filter Fiber Glass Top Mount Sand Filter with clamp lock valve Filter Dia 700 MM Flow 10 m3/hr Make: Aquapac , Emaux, Pool buddy 144 Pump Capacity - 5hp, 3 Phase , water proof Standerd , Ring lock Design , S.S.316 Salt &Mechanical Seal Make: Aquapac , Emaux, Pool buddy 145 Filter Media 146 finger Jet Nozzles Floor type in Abs Plasctic Make: Aquapac , Emaux, Pool Buddy 147 Pipes and Fittings for fountain & Pump Room Complete Pipe And fitting (NRV, Ball valve, fitting, pipe ) in UPVC make Supreme/Finolex All valves Zoloto/Audco L& T 148 Control Panel All the components used will be of desired quality like L&T , Havells Schnider or Equivilant oure box will be locally fabricated Made in India 149 Under WaterLED Light 18w , 12v 150 Wiring & Conduting 151 Power Controller for Light 152 Drawing Commisioning & Transportation 153 Fine dressed & machine cut edges (4*4*3) thick Mandana flooring over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) jointed grey cement slurry mixed with pigment to match the shade of stone complete as per design drawing and instruction of EI. 154 Providing & fixing door, window, chowkhats and other frames, including antitermite treatment, M.S. flat, hold fasts of size 250 x 40 x 3mm fixed with M.S. bolt 5mm dia 50mm long duly embedded in cement concrete M-15 grade : Sal wood Grade - I. 155 Providing and fixing wood panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled and glazed shutter 25 mm to 40 mm thick 156 Shesham wood grade I 157 IS 710- 1976 marked 12 mm thick commerical ply 158 SS wire gauge 14 mesh x 24 gauge 159 Providing and Fixing Cushion Vinyl/Fully flexible Vinyl Flooring confirming to I.S.-3462 Flooring of approved make with fibre base using rubber base adhesives including rolling with light wooden roller complete : 2.0 mm thick. 160 Supplying and fixing wood work in frames of wall panelling, false ceiling partition wall etc. as per approved design and drawing including antitermite treatment. Hollock wood Grade - I. 161 Add extra in frames for circular members such as in fan lights, staircase railing etc. 162 Varnishing with varnish of approved brand and manufacture : Two or more coats glue sizing with copal varnish over an under coat of flatting varnish. 163 Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, Laminated (colour) finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of laminated ( colour) having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-E weather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shutter shall be made of 39w x 69h mm Extruded 3 box multi-chamber UPVC Window profile section of laminated ( colour) having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. 164 Providing and fixing of uPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have „O‟ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with „K‟ & „O‟ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. 165 Providing and fixing of openable uPVC Doors with or without fix top: Frame Made of Extruded uPVC Window Profile Section of size 60w x 70h mm having outer wall thickness of 2.75mm (+/- 0.2mm) and 3 box multi-chamber construction, Laminated (colour) finish, duly reinforced with 1.2mm thick GI section. All the corners shall be mitered cut & thermal welded so as to form door frame. Fix Mullion made of 60w x 80h mm uPVC Profile Section with steel reinforcement shall be provided for the top fix portion of the doors or in case of the doors having more than two openable shutters, as per the requirement / drawing. Frame of openable door shall have co-extruded EPDM/TPE-E gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter : The shutters of openable door shall be made of 60w x 95h mm Extruded 3 box multi-chamber uPVC Window Profile Section of laminated( colour) having outer wall thickness of 2.75mm (+/- 0.2mm) provided with reinforcement of 2.0 mm thick GI section duly mitered cut & thermal welded at all corners, provided with center mullion (if specified in drawing) of size 60w x 80h mm uPVC Profile Section and fitted with uPVC glazing bead of size 36 x 20mm with inner and outer co-extruded EPDM/TPE-E weather seal gaskets alongwith 6mm thick ISI make plain float glass. 166 Providing & fixing 12 mm thick tegular edge Glass Fibre Reinforced Gypsum False ceiling tiles of size 595 x 595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm/sqm.) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to formgrids of 600x600mm and wall angle of size 21x21x0.30 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6 mm dia and 50mm long dash fasteners, 4mm GI adjustable rods with galvanised level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all Tsections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-Charge. 167 Add extra for Random Rubble stone masonry with hard stone in Square or Rectangular pillars 168 Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof in Ordinary or hard rock. 169 Providing and laying in position specified grade ofcement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcementfor Beams, suspended floors, roofs, griders having slopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. Design MixM25 grade Design Mix by usingmin 410 kg of cement per cum . 170 P & F M.S. Foot Rests in with C.M.,1:3, standard design in 20mm square M.S. bar 50 mm embedded in wall & 10 cms. projected out complete. 171 Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification 75mm thick. 172 Providing and fixing concertina coil fencing with required dia 610 mm (having 15 nos. round per 6 metre length) up to 3m height of wall with existing angle iron Y shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. stud tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron all complete as per direction of Engineer In Charge with reinforced barbed tape (R.B.T.)/Spring core(2.5 mm thick) wire of high tensile strength of 165 kg/sq.mm with tape (0.52 mm thick) and weight 43.478 gm/metre (Cost of MS angle, CC block shall be paid extra) 173 Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M15 grade Nominal Mix 1: 2: 4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size). 174 Supplying at site prestressed cast boundary wall slab manufactures with machine vibrated automatic plant of M-30 concrete of size 2100 x 300 x 50 mm by providing 4 nos 3 mm dia high tensile steel wire or required length. prestressed cast boundary wall slab shall be fixed in pre stressed cast manufactures with machine vibrated automatic plant of M 30 grade concrete post of size 150 x 150 mm x 2400 mm height by providing groove of size 60 mm wide and 40 mm deep upto 1.80 length and providing 7 nos 3 mm dia high tensile steel wire, concrete post shall be embbeded in cement concrete mix with 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) as per manufactures specification and directed by Engineer-in-charge. 175 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated „J‟ or „L‟ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 3.0mm thick (Wt. 5.0 Kg./Mtr. Sq.) 176 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing upto any pitch including fixing with polymer coated „J‟ or „L‟ hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% Ultra-voilet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall confoim to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2.0mm thick (Wt. 3.3 Kg./Mtr. Sq.) 177 Construction of Tube-well upto 100 Meter depth and above in all type of rocks by DTH system and over burden, to accommodate casing pipe of following sizes in all types of soils and over burden including lowering of casing pipes, but excluding cost of casingpipes as per IS : 2800 (Part I & II) 1979 specifications. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal dia of casing pipe: 150mm-do- 178 Supply of ERW M.S. black casing pipe ISI marked (IS:4270/1992) of grade Fe410 of following sizes at site of work. 150 mm Nominal bore of pipe 179 Supply of strainer pipes made of ERW M.S. black pipe ISI mark of following sizes at the site of work including required size of slotting as per IS:8110-1985. 150 mm Nominal Bore. 180 S & F tube well cover ofM.S.sheet (6mm thick) with nuts and bolts complete for casing size: 150mm dia 181 S & F M.S. clamp, set of 50 ×6mm flat iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set. 182 P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR6.0 Sq.mm 3 core flat / Round 183 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Coppercable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withelectrolytic gradeCopper made of copper rodsconfirming to IS 613-1964, of purity >99.7 %,Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure A attached with this BSR. Armoured 10 Sq. mm4 Core 184 Providing & Fixing of HDPE pipe Confirming to IS:4984:2021for water supply suitable for submersible & jet pump with required fittings ie socket, elbows, tee etc. complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .for vertical installation 185 50 mm OD 6 kg / cm2 186 75 mm OD6 kg / cm2 187 Providing & Fixing of HDPE pipe Confirming to IS:4984:2021for water supply suitable for submersible & jet pump with required fittings ie socket, elbows, tee etc. complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR for Horizontal installation 188 50 mm OD4 kg/ cm2 189 75 mm OD4 kg/ cm2 190 P & F Gun-metal Non-return Valve or Check Valve (IS :Make) of approved make, superior quality: 50mm nominal bore. 191 Horizontal 192 Vertical 193 Supply & Stacking good soil of earth at site complete including loading unloading & Transportation etc. Good soil of earth 194 Supply of dry manure including loading unloading,transportation & stacking at site. Farm yard manure(organic) 195 Spreading of manure , good earth in required thickness (cost of manure and good earth to be separately ) 196 Digging of pits size 60x60x60 cms. Including removal of stones Manuring applicable of insecticides & watering atleast 15 litre per plant after plan ting. 197 Supply of different varieties of palms in poly bags/earthen pot according to height growth and age of plant at site including loading unloading and transportation etc. complete 198 Fox talepalm 5 to 8 feet 199 Fish tale palm 5 to 8 feet 200 Supply of different varieties of indoor plantsin poly bags/earthen pot according to height growth and age of plant at site including loading unloading and transportation etc. complete Different champa 125 cm to 215 cm height 201 Supply of flower Garlands & Flower petal’s including transportation at site.(Complete) Mogra Garland 1.5 feet long 202 Supply of different varieties of bougainvillea in ply bags/earthen pot according to height growth and age of plant at site including loading unloading and transportation etc. completeDifferent varieties of bougainvillea 600mm to 900mm 203 Supply of different varieties of rose plants in poly bag/ earthen pot according to height growth and age of the plant at site including loading unloading and transportation etc. complete 204 Desi rose / root stock plant 205 Ganganagari rose plant in poly beg 206 Different varieties of grafted rose plants in poly bag 207 Different varieties of grafted rose plants in poly pot/earthen pot 208 Supply and planting following in poly bags / earthen pots wellbranched, well established & free from disease of 600 mm min.height shurbs at site in 0.45 m dia holes,0.45 m deep dug inthe ground,mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required.Phonenixsylvertris ( Date Palm) 209 Supply and planting following speciesbest quality container grown healthy trees of 2 mt. min. height, well established & free from disease at site in 0.90 m dia holes,1 m deep dug in the ground,mixing the soil with decayed farm yard/sludge manure,backfilling the hole watering etc as required. 210 Neem(Azadirachta indica) 211 Jacaranda mimosifolia(Neelli Gulmohar) 212 Acacia senegal 213 Bauhinia blakeana (Arckid) 214 Providing and stacking of Terminalia arjuna of height 150-165 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 215 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 216 Providing and stacking of Phyllanthus emblica (Amla) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-in-charge. 217 Providing and stacking of Nyctanthes arbor-tristis (Hasingar) of ht. 90-105 cm in Earthen pots of size 20 cm as per direction of the officer-in-charge. 218 Providing and stacking of Tamarindus indica (Imli) of height 120-150 cm. in big polybags of size 25 cm as per direction of the officer-in-charge. 219 Providing and stacking of Nauclea cadamba (Kadam) of height 150-165 cm. in big poly bag of size 25 cm as per direction of the officer-in-charge. 220 Providing and stacking of Thevetia nerifolia of height 60-75 cm. with 5-6 branches in poly bags of size 25 cm as per direction of the officer-in-charge. 221 Providing and stacking of Ficus religiosa (Peepal) of height 150-165 cm. in big poly bags of size 30 cm as per direction of the officer-in-charge. 222 Providing and stacking of Polyalthia pendula (Ashok Pendula) of height 150-165 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge. 223 Providing and stacking of Cassia javanica of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 224 Providing and stacking of Cassia nodosa of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 225 Providing and stacking of Dalbergia sissoo (Seasam) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 226 Providing and stacking of Eugenia jambolana (Jamun) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 227 Providing and stacking of Albizzia lebbek of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge. 228 Providing and stacking of Bassia latifolia (Mahua) of height 90-105 cm. in big polybag of size 25 cm as per direction of the officer-in-charge. 229 Providing and stacking of Alstonia scholaris of height 150-165 cm. in bag of size 25 cm as per direction of the officer-in-charge. 230 Providing and stacking of Faras of Height: 26-30 in big poly bags of size 25 cm as per direction of the officer-in-charge. 231 Providing and stacking of LAVEDA (Gond) of Height: 5-6 in big poly bags of size 25 cm as per direction of the officer-in-charge. 232 Bamboo plant of Different varieties P.B(14”X14”)- 4‟-5‟ 233 Providing and stacking of SENNA SIAMEA of Height: 26-30 in big poly bags of size 25 cm as per direction of the officer-in-charge. 234 Providing and stacking of Prosopis cineraria of Height: 26-30 in big poly bags of size 25 cm as per direction of the officer-in-charge. 235 Providing and stacking of Capparis decidua of Height: 26-30 in big poly bags of size 25 cm as per direction of the officer-in-charge. 236 Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 600 mm min. height shurbs at site in 0.45 m dia holes,0.45 m deep dug in the ground,mixing the soil with decayed farm yard/sludge manure,backfilling the hole watering etc as required. Furcaria with 10-12 leaves ( cactus) or equivalent (other Cactus) 237 Hedges of various varieties 238 Golden durantain P.B(5”X6”)-6”-1’ 239 TecomaGoudichoudi in P.B(9”X11”)- 2’ 240 Enarmi in P.B(5”X5”)- 1’ 241 Supply of different varities of tree/shrubs/climbers according to height and age of the plant at side including loading/unloading & transportation etc.complete 242 Different flowering plants 900mm to1500mm 243 Different varieties of shrubs 600mm to 900 mm 244 Different varieties of climbers 900mm to 1500 mm 245 Supply of different varieties of blubsincluding loading unloading and transportation etc. complete 246 Supply of different varieties of caladiumblubs 247 Supply of different varieties of amrilis lilly bulb 248 Supplyof tube rose bulbs 249 Supplyof hemaniths bulb 250 Supplyof Asiatic Lilly bulb 251 Supplyof oriental lilly bulb 252 Supplyofdifferent variety of gladioli bulb 253 Planting of trees /shrubs/ hedge and climbers plants at desired distance in row and watering 254 Laying of lawns including ploughing levelingbreaking of clods manuring and removal of stones etc. (cost of manure or extra good earth to be paid separately )maintenance of lawn foe 30 days or more till the grass forms a thick lawns free from weeds and fit for moving in the duration of planting if lawn die some where the contractor will replant it at his own cost. Laying of Selection No.1 grass tiles (2’X2’ size) for development of garden, including levelling of soil and spreading of manure 255 Maintance of lawns or turfing of slopes (rough grassing) for a period of one year including watering etc. (Quantity include for 03 years) 256 Maintenace of Plants by the contractor including of pits/bids watering preparation of Thavala Hoeing weeding etc. & application of insecticides etc. & security if the plant die during maintenance contractor has to replace same height plant at his own cost. 257 Maintenance of shrubbery or hedges cutting including disposal of rubbish with all leads and lifts 258 Supply,Fixing & commissioning of HDPE Pipe conforming to IS:4984,suitable for the respective working pressures 259 HDPE PIPE 100mm PN10 PE100 260 HDPE PIPE 75mm PN10 PE100 261 HDPE PIPE 63mm PN06 PE100 262 HDPE PIPE 50mm PN06 PE100 263 HDPE PIPE 40mm PN08 PE100 264 HDPE Heavy Duty fittings 265 Excavating trenches of required width for pipes cables etc. including excavation for sockets, depth up to 1.5 Mtr. including taking out the excavated materials, refilling the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layers by ramming, watering etc., stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. ORDINARY ROCK 266 Pipes cables etc. not exceeding 80mm dia 267 Pipes cables, etc. exceeding 80mm dia but not exceeding 300mm dia. 268 Supply,Fixing & commissioning of3/4 Size Inlet Pop up Sprinkler. Built to accommodate Lower pressure with radius of throw 25 to 50 ft. & flow of 0.76 to 9.63 USGPM at operative pressure of 1.72 to 4.8 Bar (25-70 PSI), the sprinkler shall be gear driven rotary type full & part circle (40-360 degree) in one,5 pop-up hight,having 20mm(3/4) Female threadedinlet, Check-O-Matic maintains up to 2.8m (8), with 12 nos. Nozzle tree for trajectory 8 nozzle for standard 25 deg. and 4 nozzle for 10 deg.The body of sprinkler is ABS plastic & non - corrodible. 269 Supply,Fixing & commissioning of1/2 Size Inlet Pop up Sprinkler. Built to accommodate Lower pressure with radius of throw 14 to 32 ft. & flow of 0.4 to 6.0 USGPM at operative pressure of 1.72 to 4.8 Bar (25-70 PSI), the sprinkler shall be gear driven rotary type full & part circle (40-360 degree) in one,4 pop-up hight.The body of sprinkler is ABS plastic & non - corrodible. 270 Supply,Fixing & commissioning of Pop up spray head.Available with pre-installed,color-coded Variable Arc Nozzles in five radii.Radius of throw 7 to 18 ft. & flow of 0.30 to 4.5 USGPM at operative pressure of 20 to 70 PSI,adjustable part-circle (40-360 degree) ,having 13mm(1/2) Female threadedinlet.The body of sprinkler is ABS plastic & non - corrodible. 271 Providing & fixing of NPC In-Built Drip Line 16mm/30cm/2Lph with fittings like - Tee, Gurmat, Elbow, Take off and stack every 1.5 meter. 272 Supply,Fixing & commissioning of1/2 or 3/4 Pop up Connecting Swing joint Assembly. The tubing shall be made of polyetylene having wall thickness of 2.3mm ,a working pressure of 5.5 kg/cm2 at 43oC and a surge pressure of 16.6 kg/cm2. The fittings shall be made of UV resistant thermo plastic. 273 Supply,Fixing & commissioning of Imported HDPE service saddle ofvarying size 274 Supply,Fixing & commissioning of PVC Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem non mechanical ,with a base which permits maximum penetration into the valve of size 75mm. 275 Supply,Fixing & commissioning of PVC Ball Valve,security pivot to maintain lever in space,double water tight joint,direct injection stem non mechanical ,with a base which permits maximum penetration into the valve of size 63mm. 276 Supply,Fixing & commissioning ofAir release valve,The Air release valve shall be capable of both releasing and admitting air from and into the line. The working pressure shall be 5 bar. 277 Supply,Fixing & commissioning of 12 Rectangular Valve Box withgreenlid and corrugated structure with unique shovelaccess slot and bolt hole knockout 278 Supply,Fixing & commissioning of 10 Round Valve Box withgreenlid and corrugated structure with unique shovelaccess slot and bolt hole knockout 279 Supply,Fixing & commissioning of 6Roundbox withgreenlid and corrugated structure with unique shovelaccess slot and bolt hole knockout 280 Supply,Fixing & commissioning of Quickcoupling valve made up ofsolidbrass with locking covercorrosion resistant and stainless steel springsize 3/4 281 Supply,Fixing & commissioning of Key threads into top of QCV to provide water access size 3/4 282 Supply,Fixing & commissioning of Automatic Disc Filter having discarge 100 m3/hr with exhaust valve, Inlet/outlet is 4/4 working pressure 2 Bar or 30PSI to 8 Bar or 116 PSI, Maximum flow for flushing at 2 Bar is 15m³/hr, flushing cycle time is 10 second, exhaust valve 1.5 or 40mm, Filtration area 750cm², Construction of material- Epoxy Coated carbon steel 37-2, Filter Lid Epoxy coated carbon steel 37-2 high density polypropylene, cleaning mechanism PVC and Stainless Steel 316L, Exhaust Valve-Brass and SS316L, BUNA-N, Seals-BUNA-N, Control-Aluminium, Brass, SS316, PVC, Acetal. with Pressure Guage. 283 Supply,Fixing & commissioning of hydropneumatic type Pumping Unit having total discharge 7.0 LPS at 70 mtr. Head at Ground level, (1 working+1Standby) Each pump have discharge (7.0 Lps @ 70 Meter Head), with 1 No. of Jockey Pump having discharge 2 Lps @ 68 meter with PLC control panel with VFD , will provide low flow and pressure maintenance. This control panel shouldhave a manually operated switch for the re-prime pump.It should also have an input for the flow meter, and controls to operate the existing auto-flush wye strainer and Filter. pressure transducer point included, sensor leads from suction header, cables from panel to motors . 284 Supply,Fixing & commissioning of 100 Station Decoder Controller and having following features,Maximum stations per standard system: 6400, Maximum stations per Smart Hub system: 9000, Maximum stations per output board: 800, Maximum physical wire paths per output board: 4, Maximum modules per wire path: 250, Maximum modules per output board: 500,Maximum modules per gateway or Smart Hub: 1000, Maximum modules per standard system: 4000, Maximum modules per Smart Hub system: 9000, Maximum simultaneous stations per wire path: 100, Maximum wire path distance with modules evenly spaced along its length (central controller to module):4.2Km (13,622 ft) Maximum allowable voltage drop per physical wire path:6 volts, Maximum wire path distance (module to solenoid):122m (400) feet, Minimum module electrical surge rating:20 KV, Communication cable wire size:2.1 mm² (14 AWG), Communication Interface.The communication interface can control up to 250 modules or 800 stations per wire path.Each interface will support up to 4 wire paths.Each wire path can support 100 stations (200 solenoids) operating simultaneously.The interface will support an input voltage of 100-240 VAC, 50/60Hz, 75VA.The interface output voltage is 40 VAC.The standard interface will be connected to the PC via fiber-optic modems and fiber-optic cable.The maximum distance from the PC to the interface with the standard fiber-optic interface is 500m (1640 ft).Smart Hub interfaces can be connected to the central FIU via shielded twisted-pair communication cable up to 50,000 feet or via UHF radio up to two miles.The interface enclosure is rated IPx3 (outdoor use).The interface will be grounded, earth ground resistance to be 10 ohms or less. Modules. Supply and install Toro modules, model number DEC-ISP-1, DEC-ISP-2 or DEC-ISP-4.Modules will be epoxy potted for direct burial.The module address will be pre-programmed and permanently marked on the module case.The modules will operate 1 or 2 Toro GDC latching solenoids simultaneously per output.All stations on a module can operate simultaneously.The module to solenoid wiring should be sized for a maximum resistance of 2 ohms. 285 Supply,Fixing & commissioning of 2 Solenoid Valve BSP threaded, 24 volt 50 HZ AC Plastic solenoid valve having max. working pressure of 150 PSI, Globe/angle construction, precise pressure control option with compact EZ Reg dial design,tough 33% glass filled Nylon (GFN) and stainless steel construction external manual bleed for system flushing, manual flow control: adjustable to zero flow, self aligning bonnet, easily serviceable without system removal, proven encapsulated, injection moulded solenoid Inrush : 0.30 Amps, 9.6 VA Holding : 0.20Amps, 4.8 VA . 286 Supply,Fixing & commissioning of Single Station Decoder having ISP 2 wire modules are rated at 20 KV Surge Protection 287 Supply,Fixing & commissioning of Line Surge Protection unit for protection of Irrigation System 288 Supply,Fixing & commissioning of5/8 x 8 feet long Copper Clad Grounding Rod & Clamp for Decoder Controller & LSP. 289 Supply,Fixing & commissioning of6 Round valve box with cover .The valve boxes shall be heavy duty plastic with poly vinyle chloride reinforce and a green top. 290 Supply,Fixing & commissioning of 14/2 AWG Copper Conductor Direct Burial Cable, IS:8130 Class 1 & ASTM- B3 with special grade PVC Type B& UL Standard 493 and outer sheated with UV & abrasion resistant PE, Temp. Rating 10 - 75 Degree Celcious, Voltage Grade upto 600. 291 Supply,Fixing & commissioning of DBR/Y Water Proof Wire Connector The 3M™ Direct Bury Splice Kit DBR/Y is used to electrically connect two or more pre–stripped copper wires and moisture seal the connection for direct burial. The kit includes a 3M™ Performance Plus Wire Connector R/Y+ and a high impact, UV-resistant polypropylene tube prefilled with moisture-resistant grease. Maximum Voltage Rating:600 V Application Temperature:32°F to 120°F (0°C to 49°C) Operating Temperature:-40°F to 221°F (-40°C to 105°C), Tube :Impact and UV Resistant Light Blue Polypropylene. 292 Supply,Fixing & commissioning of 4 Size Water Flow Sensor ,Flow sensor shall be the latest “state-of-art” microprocessor based electromagnetic type, having flanged connections with integral sensor, transmitter, processor & indicator suitable for measurement of water flow. Water contains silt and sand particles. Meters shall be lined with Polyurethane (PU) liners. 293 Sweeping / cleaning of gardens roads lawns paths and disposal of all rubbish 294 Security of the garden per gate for 24 hours in 3 shift with the exilitary persons 295 Carriage of Materials including loading and unloading For 5 Km all complete in site-incharge Building Rubbish Stone metal (Grit and ballast etc.) 296 Fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:4 ( 1cement : 4 coarse sand) with joints finished flush. Red Sand stone size not less than 1350 Cm 2 , a) 40mm 297 Providing & FixingEquality Flame Sculupture Work of Overall Sculpture Height: 12 feet, rest Dimension according to proportion all Complete as per Site In-charge. 298 Providing & Fixing of Bird Sculpture (FRP Materials)Total Height: ~9 ft, rest dimension according to drawings all Complete as per Site Incharge. 299 Providing & Fixing of Bird Selfie Point (FRP Materials)Total Height: ~7 ft, rest dimension according to drawings all Complete as per Site Incharge. 300 Providing & Fixing of Music Selfie(FRP Materials)Total Height: ~8 ft, rest dimension according to drawings all Complete as per Site Incharge. 301 Providing & Fixing of Selfie PointsTotal Height: ~6 ft, rest dimension according to drawings all Complete as per Site Incharge. 302 Providing & Fixing of TREE SELFIE POINTS (FRP Materials) Total Height: ~8 ft, rest dimension according to drawings all Complete as per Site Incharge. 303 Providing & Fixing of Flower sculpture (FRP Materials) Total Height: ~8 ft, rest dimension according to drawings all Complete as per Site Incharge. 304 Providing & Fixing of Feather sculpture (FRP Materials) Total Height: ~7 ft, rest dimension according to drawings all Complete as per Site Incharge. 305 Providing & Fixing of Spiral sculpture (FRP Materials) Total Height: ~ 6 - 7 ft, rest dimension according to drawings all Complete as per Site Incharge. 306 Providing & Fixing of Fountain sculpture (FRP Materials) Total Height: ~8 ft, rest dimension accordingto drawings all Complete as per Site Incharge. 307 Providing & Fixing Park Activities all complete as per Site-in-charge. 308 Supply & fixing various item of open Gym as per following details. Item should be fix properly including E/W & C.C. In M- 20 as per requirement LEG PRESS DIMENSIONS:- 1.00 E 1840mm (Length) x 360mm (Width) x 1560mm. (Height) SAFE AREA-2.8 x 1.4Mr.Leg Press equipment made from C Class G.I. pipe of different NB. NB stands for Nominal Bore Sizes ie. Intemal Diameter of pipe in millimeters The center pipe is of 100mm NB made from C Class GI The Sleeve frame is of 100 OD and of M.S. Seamless Pipe with thickness 5mm. This sleeve can be disassembled from main frame. The bottom support of M.S. round plate of 0250 mm & 10mm thick The remaining outer frame is of 32NB made from C class Gl pipe The foundation used for fixing is structure and made from center pipe of G1 of 80mm NB C class welded with M.S. round plate of 0250 mm & 10mm Thick Main pipe supported with 25 mm X 25mm M angle of 3 mm thickness and 20mm x 40mm CRC square pipe of 3mm thickness Seat & Back rest provided are made up of MS deep draw quantity of 2mm Beckness with no joint with uniform cuter edge radius 20 The footrests are made from casted Aluminum material, haveng saxs 130mm A 310mm X Doum thack With the support of 310 X 130mm X 2mack M3plate 309 Supply & fixing various item of open Gym as per following details Item should be fix properly including E/W & C.C. in M- 20 as per requirement POMMELO HORSE DIMENSIONS:-2150mm (Length) x 800mm (Width) x 800mm (Height). SAFE AREA:-5Mtr x 3.5Mr.Pommel horse equipment made from C Class G.I. pipe of different NB. NB stands for Nominal Bore Sizes ie. Internal Diameter of pipe in millimetersThe main frame of 80NB and 50NB made from C Class Gl. pipe The handle frame is of 32NB made from C Class G.I. pipe40mm x 40mm CRC square pipes frame is placed on the 25mm x 25mm x3mm M.S. L Angle with 60 x 10m thickness flat is used for support.Closing Caps are made up of high quality Fiber reinforced Plastic maternal High tensile steel with galvanized nuts and bolts are used for assemblyThe powder coating is done with Pure Polyester powder Ackzonoble or Berger Paints with 60 to 70 micron thickness. 310 Supply & fixing various item of open Gym as per following details. Item should be fix properly including E/W & C.C. in M 20 as per requirement.CHEST CUM SEATED PULLER DIMENSIONS:-2000mm (Length) x 710mm (Width) x 2200mm. (Height).SAFE AREA: -3.0Mtr x 1.7Mtr. Chest press cum seated puller equipment made up of C Class G.1. pipe of different NB NB stands for Nominal Bore Sizes ie. Internal Diameter of pipe in millimeters The center pipe is of 100NB made up of C Class G.I. pipe. The bottom welded with support of M.S. round plate of 0250 mm & 10mm thickness.The connecting pipes are made up from 25NB C class G.I. pipe. The handle frame is made up from 32NB C class G.I. pipe To build structure bushes are used which are made from seamless pipe of 50mm O.D. and as well as 50mm diameter solid bar is used. 6mm thickness The foundation used for fixing is a structure and made from center pipe of G.1 of 80 NB C class welded with M.S. round plate of Ø250 mm & 10mm thick. Main pipe supported with 25mm X 25mm M.S. angles of 3 mm thickness and 20mm x 40mm CRC square pipes of 3mm thickness.The seats and Back rests are fitted on the outer frames are made up of M.S. Sheet of size 330 mm X 300 mmx2mm thickness and deep drawn and pressed in tools and dies to have uniform radius of 20 mm with no sharp edges. Closing Caps are made up of high quality Fiber reinforced Plastic material Pins used of Dhameter 25mm and 17mm are made up from SAL 8620 bright material The bearings used are of 6206zz & 6203zz permanent 311 Supply & foing various item of open Gym as per following details. Rem should be fix properly including E/VV & CCM 20 as per requirement CROSS TRAINER DIMENSIONS 1320mm (Length) x 600mm (Width) x 1750mm. (Height) SAFE AREA: 1.77 x 1.2Mtr. Cross trainer equipment made from C Class G. Pipe of different NB The main frame Pipes are of 80NB C Class G1. Pipe with single bend pipe with 250mm radius. The bottom support of M.S. round plate of B250 mm & 10mm thick The Handie Frame is made up of 25NB C Class G.I. Pipe The foundation used for fuxing is a structure and made from center pipe of G1 of 80 NB C class wolded with M.S. round plate of Ø250 mm & 10mm thick. Main pipe supportedwith 25 mm X 25mm M.S. angles of 3 mm thickness and 20mm x 40mm CRC square pipes of 3mmthicknessTo build structure bushes are used which are made from M.S.seamless pipe of 60mm OD. With 5 mm thickness.The footrests are made from Aluminum casting material of size 130 mm X 310mmX5mm thickness and mounted on MS. Plate of Size 130mmx310mmx3mm thick Closing Caps are made up of high quality Fiber reinforced Plastic material Pins used of Diameter 35mm, 25mm, and 17mm are made up from SAE 8620 bright. The Bearings used are of 6007zz 6206zz and 6203zz permanent lubricated sealed bearing of reputed brand High tensile steel with galvanized nuts and bolts are used for assemblyThe powder coating is done with Pure Polyester powders of Ackzonable or Berger Paints with 60 to 70 Micron 312 Standarad See- Saw Roto Seal Rotation molded seats of thickness 60mm are used in these see-saw, it has been provided with bolts to fix it too see-saw frame which has a plates of 200x150x5 welded on to the frame. Handle has been provided on the frame made up of 20 NB pipe and also conforming to EN standards.Frame Frame of standard see-saw is designed using 15 NB 20NB & 25 NB G1 pipe and it has been given radius by suitable bending techniques Plates has been welded at places were seal has to be installed so that seats can be fixed to the frame with suitable bolting arrangment. Standard see saw clamp is used in FRP see saw so as to provide required motion for the see sawTyre Tyre is used in FRP see saw to avoid breakage of the FRP cover while it is coming down with certain force while in use Foundation Angle 25x25x5 Pipe 50 ND hot dip Galvanized pipe 313 S/F of DOUBLE SWING ar per followingSOND hot dip galvanized swing top pipe of wngth conforming to 15 1230 with Gf teckness of 60 1730 1961 welded at its one ends (to be bolted over MAPS attachment deck pipe) Special swing clamps made up of te parts are joined together with A6 Allen bois along wit Hook & a specially desigried swing pin. The S-Hook is specially designed to house a bearing for smooth & ros swinging. The clamps are made from injection molded Nylon 6 plastic 225mmx103mm junction box made from 3mm thick 314 S/f of Wave Slide 2.1 m as per following Specification Ladder Frame 25NB & 20NB Frame GI Pipe conforming to IS 1239(Part 1): 1979- Hand Grip conforming to EN1176- 1:1998 (4.2.4.6) -Ladder Step-Cold formed 16 Gauge GI Plated Sheet Length 500mm & width 90mm EN1176-1:1998 (4.2.9.1) conforming to-16 SWG GI Plated Platform of size- 500x450x60mm-80NB hot dip galvanized center support pipe of length 2590mm conforming to IS 1239 with GI thickness of 60mFRP Wave Slide Thickness 5mm SS Nut Bolts conforming to ASTM E-1086: 1994 -Medium H-Support 25NB GI Pipe length 1490mmwith 10mm tor rod of length 300mm for support & strong foundation -Small H-Support 25NB GI Pipe length 600mmwith 10mm tor rod of length300mm for support & strong foundation 315 S/F OF FOUR SEATER MGR :- As per following Specification Rec. Age 3-8 yrs. The area 1.5m dia Safe play area 2.5m dia Ther item is having its main frame made up of 25 & 40 NB GI pipes. The stand is made in 80 NB GI pipe. The Whole structure is mounted on heavy duty bearing shaft. The bearing used is of heavy duty bearing permanentały lubricated with water sealant. The seal frame is made in 20 NB GI pipes. The seats attached area made out of molded plastic type in rotational molding process in LLDP the seats have handrails so that the child does not fall it accommodates 4 children at a time 316 Providing & Fixing Manalapene HDPESheets having thickness of 10 mm is used in SeeSawSeats 2.89MM Galvanised pipe are used for frame with Powder Coated3. 28MM Galvanised pipe are used for Handle Pipe. 4.Bearing 2 NOS OF KCI MAKE 6205 IS FIXED FOR SMOOTH FUNCTIONING5.All pipe ends will be covered with NYLON CAPS. all Complete as per Site in-Charge 317 Providing and fixing 1.Kids Can Slide from the height of 5ft. 2.Roto Moulded LLDPE Slides are produced from UV stabilised virgin material. 4.Powder Coatedis done on Platforms which is made of Galvanised Sheet with precision punched hole of 10mm.5.20 , 28 & 33.3 mm Galvanisedpipe are used for Ladder Railing & Platform Railingwith further treatment of powder caoting. 6.89mm Galvanisedpost are used as structure post with further treatment of powder coating. 7. Platform Sizes used in this Slide - 1450 x 750 x 85mm . 8.Powder Coatedis done on Ladder which is made of Galvanised sheet with Triangle steps.9.All nuts & Poles will be covered with NYLON CAPS. 10.89mm Galvanisedpipe are used for Monkey Bar Structure post with further treatment of powder coating. 11.60mmGalvanisedpipe are used for Swing structure post with further treatment of powder coating ,Durable rubber flap with triangular hook & PVC Coated chains for the safety of handsall Complete as per Site in-Charge 318 Providing and fixing 1. Roofis made ofManalapene HDPESheets having thickness of 15 mm . This sheet is made of dual colour sandwich system sheet where in top and bottom will be of one color and middle part will be of different color to make it more attractive and colourful which gives fantastic look.This HDPE Sheet material having the features of Fire/Heat retardant, Waterproof, UV Protected, Weather, Termite, Chemical and Impact Resistant is safe for children to play. TUV Test reports with regard to chemical testing of HDPE sheet as per European and American Safety Standard is available. 2. Roto Moulded LLDPE Slides are produced from UV stabilised virgin material. 3. Decorations are made of HPDE sheets having thikness19mm. 4. Powder Coating is doneon Stairs , Bridge & Platforms which is made of Galvanised Sheet with precision punched hole of 10mm. 5.28mm Galvanised pipe are used for Platform & Ladder Railing with further treatment of powder caoting 6. 89mm Galvanised post are used as structure post with further treatment of powder coating. 7. Plank panels are made of HPDE sheets having thickness 10 mm. 8. Slide Entry Gate Panels are used for children safety so that they dont fall down. 9.Nylon clamps are used for proper installation of all panels. all Complete as per Site in-Charge 319 Providing and fixing1.89 , 42 , 60 & 28MM Galvanisedpipe are used in this circular climber withfurther treatment of powder coatin2.All pipe ends will be covered with NYLON CAPS. 3. Nylon rope 16MM & rope bracket & climbing stone thriller with further treatment of powder coating 4.Climber stone holding frame Galvanised Sheet 2mm thickness with furthetreatment of powder coating all Complete as per Site in-Charge 320 Providing and fixing 1.Dia of this Merry Go Round - 6ft2.33.3MM Galvanised pipe are used for sitting frame with Galvanised sheet of 2MM & 113.5MM Galvanisedcenter pipewith further treatment of powdecaoting 3.Powder Coated is done on Merry Go Round Base which is made of Galvanised Sheet having thickness of 4MM with cheqred sheet of 40MM. 5.Merry Go Round Grouting base is made of MS Square pipe 40x40x2.5MM. 6.Bearing fixing rod is of 50MM Dia. all Complete as per Site in-Charge 321 Providing and fixing 1.Roto Moulded LLDPE Roofs are produced from UV stabilised virgin material. 2.Roto Moulded LLDPE Slides are produced from UV stabilised virgin material. 3.Roto Moulded LLDPE Decorations are produced from UV stabilised virgin material. 4.Powder Coated is done on Stairs , Bridge & Platforms which is made of Galvanised Sheet with precision punched hole of 10mm.5.28mm Galvanisedpipe are used for Platform & Ladder Railing with further treatment of powder caoting. 6.89mm Galvanisedpost are used as structure post with further treatment of powder coating.7.Handrails of stairs are made of Galvanised pipe with further treatment of powder coating . 8.Roto Moulded LLDPE Panels are produced from UV stabilised virgin material. 9.Slide Entry Gate Panels are used for children safety so that they dont fall down. 10.Nylon clamps are used for proper installation of all panels. 11.All nuts will be covered with NYLON CAPS.12.76.8mm Galvanisedpipe are used for Swing structure post with further treatment of powder coating,Durable rubber flap with triangular hook & PVC Coated chains for the safety of hands. 13. Platform Sizes used in this MPS-Square platform 1150 X 1150 X 85MM,Spiral platform920X 745 X 85MM.all Complete as per Site in-Charge 322 Providing and fixing KFE - 22 TAICHI SPINNERS CUM TWISTER MAIN FRAME:100 NB JINDAL GI PIPES HAVING WALL THICKNESS OF 3.65MM.ARM HANDLE : 32/25/20 NB JINDAL GI PIPE HAVING WALL THICKNESS 2.65MM.HANDLE : HANDLE BEARING GRIP. TWISTER DISC: PERFORATED GALVANISED SEAT HAVING WALL THICKNESS 2MM WITH PRECISION PUNCHED HOLE OF 10MM DIA. BOTTOM BASE COVER: PLASTIC INJECTION MOULDED PPCP MATERIAL. BEARING CAP: NYLON INJECTION MOULDED BEARING CAP 47MM & 62MM. PIPE END CAP: USED FOR 100NB. BEARING KIT:BUSH Ø 60MM AND LENGHTH 72MM WITH TWO NO. OF BEARING 2RS ZZ AND 2 RUBBERS SEAL FOR BEARING, CIRCLIP LOCK FOR BEARING PIN Ø25 MM. ALL NUT, BOLTS AND WASHER ARE USED IN GALVANISED. WE DO PURE POLYESTER POWDER COATING (50-60 MICRONS) FOR ATTRACTIVE LOOKS WHICH IS MEANT FOR OUTDOOR USAGE.all Complete as per Site in-Charge 323 Providing and fixingKFE - 36 COMBO -2 MAIN FRAME:100 NB JINDAL GI PIPES HAVING WALL THICKNESS OF 3.65MM. ARM HANDLE & LEG FRAME: 25/32NB JINDAL GI PIPE HAVING WALL THICKNESS 2.65MM. FOOT REST SEAT : PERFORATED GALVANISED SEAT HAVING WALL THICKNESS OF 2MM WITH PRECISION PUNCHED HOLE OF 10MM DIA.HANDLE COVER :TPEE INJECTION MOULDED. BOTTOM BASE COVER: PLASTIC INJECTION MOULDED PPCP MATERIAL.BEARING CAP: NYLON INJECTION MOULDED BEARING CAP 47MM & 62MM. PIPE END CAP: USED FOR 100NB, 32NB AND 25NB.BEARING KIT: BUSH Ø 60MM AND LENGHTH 72MM WITH TWO NO. OF BEARING 2RS ZZ AND 2 RUBBERS SEAL FOR BEARING, CIRCLIP LOCK FOR BEARING PIN Ø25 MM.ALL NUT, BOLTS AND WASHER ARE USED IN GALVANISED.WE DO PURE POLYESTER POWDER COATING (50-60 MICRONS) FOR ATTRACTIVE LOOKS WHICH IS MEANT FOR OUTDOOR USAGE.. all Complete as per Site in-Charge 324 Clearing and Grubbing Road Land. (Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.) By Mechanical Means : In area of light jungle 325 Excavation in Ordinary Rock using Hydraulic Excavator CK-90 and Tippers with disposal upto 1000 metres. (Excavation for roadway in ordinary rock with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, transporting to embankment site within all lifts and lead upto 1000m, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections.) 326 Excavation in Hilly Areas in Hard Rock Requiring Blasting (Excavation in hilly areas in hard rock requiring blasting, by mechanical means including trimming of slopes and disposal of cut material with all lifts and lead upto 1000 metres.) 327 Excavation in Hard Rock (blasting prohibited) (Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal within all lifts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross sections. mechanised 328 Plant Mix Method (Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 ) for grading- IMaterial 329 Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.) 330 PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 mix with crushed stone aggregate 40 mm nominal size mechanically mixedplaced in foundation and compacted by vibration including curingfor 14 days.) 331 Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing ) 332 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line, level andcurvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand)including making joints with without grooves (thickness of jointsexcept at sharp curve shall not to more than 5mm) including makingdrainage opening wherever required complete including painting etc.as per direction of Engineer-in-charge (length of finished kerb edgingshall be measured for payment). (Precast C.C. kerb stone shall beapproved by Engineerin- charge). 333 Providing and fixing of precast concrete interlocking blocks of M 30grade manufactured from fully computerised automatic stationerhydraulic vibro pressed machine and fully computerised automatic batching plant of class A1 / A2 as per BS 6717: 2001 with rubbermould technology including painting with lacker polishing. The CC interlocking paving Blocks be laid on average 50 mm thick bed ofcoarse sand and the joint on is to be filled with fine sand. layingprocedure on compacted subbase as defined. Complete job is to beexecuted as per the instruction of Engineer in charge. The rates tobe inclusive of all lead and lift and taxes.1. Shape : As specified by Engineer-in-charge. 2. Tensile splitting strength and breaking load as per BS : 6717-2001. 3. Colour : Grey cement natural colour. 4. Variation in Dimension : Less than 1.6mm 5. Variation in thickness : Less than 3.2mm 334 P & F –do--100mm thick(M-30 Grade) –do- 335 P & F –do--80mm thick(M-30 Grade) –do-- 336 Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces) 337 Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications stone/Boulder 338 Stone masonry work in cement mortarin foundation complete as drawing and Technical Specification Random Rubble Masonry in cement mortar 1:6 339 Stone masonry work in cement mortar for substructure complete as per drawing and Technical Specifications Random Rubble Masonry cement mortar 1:6 340 Flooring with Cobble stone of approx. Size 100x100x75 mm (thick) laid on 25 mm average thick cement mortar 1:3( 1 cement : 3 Coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the stone, laid in approved pattern complete in all respect as per direction of Engineer-in-charge. 341 Providing and fixing of reinforced Ferro-Cement drain covers designed for A class loading duly marked on cover with adequate steel reinforcement having thickness 75mm to 150mm anti corrosive bitumen painted M.S. plate , Rim and M.S. lifting hooks, Admixtures like plasticizer, bond improving compound, shrinkage, resistance compound, abrasion resistant complete as per approved design etc. Standard Size 1000x800mm (100mm thick) for span 451 to 700mm 342 Providing & Laying C.C. 1:3:6 (Stone Agreegate 20mm nominal size) all around PVC Pipe including 7.5 cm thick bed concerte [Width & Height = Dia of Pipe in CM+15CM] excluding cost of Pipe & Excavation of trenches etc. PVC pipe 160 mm dia 343 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87 .5 (160mm dia) 344 Providing and laying Filter material underneath pitching inslopes complete as per drawing and Technical specification 345 Retro- reflectorised Traffic signs (Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing) 346 60 cm equilateral triangle 347 60 cm circular 348 80 mm x 60 mm rectangular 349 60 cm x 45 cm rectangular 350 60 cm x 60 cm square 351 Direction and Place Identification signs upto 0.9 sqm size board. (Providing and erecting direction and place identification retro-reflectorised sign asper IRC:67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing) 352 Direction and Place Identification signs with size more than 0.9 sqm size board. (Providing and erecting direction and place identification retro- reflectorised sign asper IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area exceeding 0.9 sqm supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm, 2 Nos. firmly fixed to the ground by means of properly designed foundation with M 15 grade cement concrete45 cm x 45 cm x 60cm, 60 cm below ground level as per approved drawing) 353 Clearing and Grubbing Road Land. (Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness.)By Manual Means:-: In area of thorny jungle 354 Construction of Rock fill Embankment (Construction of rock fill embankment with broken hard rock fragments of size not exceeding 300 mm laid in layers not exceeding 500 mm thick including filling of surface voids with stone spalls, blinding top layer with granular material, rolled with vibratory road roller, all complete as per clause 313) 355 Granular Sub-Base with Coarse Graded Material ( Table:- 400- 2) (Construction of granular sub-base by providing coarse graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401) for grading-IIIMaterial 356 Providing and laying in position cement concrete includingcuring, compaction etc. complete in specified grade excluding the cost of centering and shuttering - M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). 357 Stone masonry work in cement mortarin foundation complete as drawing and Technical Specification Random Rubble Masonry in cement mortar 1:4 358 Providing and laying boulders apron on river bed forprotection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification. Boulder laid dry without wire crates. 359 Providing & Fixing of silpaulin 300 GSM for Clean Surface all Complete as per Site Incharge. 360 Providing and laying in position cement concrete includingcuring, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregat40mm nominal size). 361 Supplying and laying of following size Water Line (DWC SN-4 Cass pipewith Integral socket confirming to IS 16098, Size As Per DWG.) marked along with all accessories like socket, bend, couplers etc.complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 362 150mm dia pipe 363 200mm dia Pipe 364 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 approved quality /make including joining the pipe witsolvent cement rubber ring and lubricant. 365 63 mm dia 366 75 mm dia 367 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: 368 Coupler (socket) 369 75 mm dia 370 110 mm dia 371 Plain Tee 372 75 mm dia 373 110 mm dia 374 Double Door Y 375 75 mm dia 376 110 mm dia 377 Bend 87 .5 378 75 mm dia 379 110 mm dia 380 Providing, lowering, laying, aligning, fixing in position in pipe line,manually operated CI D/F Sluice valves of approved make (IS: 14846 amended upto date) PN 1.0 class of following dia complete (including jointing and jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer. 381 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : 382 100mm dia 383 80mm dia 384 65mm dia 385 Providing & Fixing LCR20-10 Product Type: VERTICAL MULTISTAGE PUMP Product Configuration Pump Classification: Standard Pump Pump Construction: Pump With Motor Component Materials Version: Cast Iron & S.S AISI 304 Seal Material: Carbon/SiC/SS316/EPDM Bearing Material: Ceramic/Tungsten Carbide Rubber Parts: NBR (Nitrile) Pipework Connection Suction & Delivery Size: 2” (50 mm) Flange Type: DIN Connection Type: Threaded - BSP Motor Specifications Mounting: IEC Enclosure: TEFC Phase: 3 Voltage: 380-415V Efficiency Class: IE2 Motor Manufacturer: Lubi Note: Component materials specified in this quote are only for major pump component. Kindly refer our Product Catalogue/Brochure for more information. LCR20-10 (Water Transfer Pump 20 M3/h on 100 mtr) 386 Providing & Fixing LHM 032-200L Product Type: SUBMERGED CENTRIFUGAL PUMP Component Materials Casing Material: Cast Iron FG 260 Impeller Material: Cast Iron FG 260 Shaft Material: S.S AISI 410 Seal Material: Carbon/Ceramic/NBR/S.S 304 Counter Flange Material: Cast Iron Motor Enclosure Material: Cast Iron with S.S AISI 202 Stator Body Pipework Connection Casing Connection: With Discharge Flanges Connection Type: Threaded - BSP Motor Specifications Phase: 3 Voltage: 380-415V Note: Component materials specified in this quote are only for major pump component. Kindly refer our Product Catalogue/Brochure for more information. LHM 032-200L (Open well pump for 30 M3/h on 50 mtr) 387 Providing & Fixing LHM 050-125Product Type: SUBMERGED CENTRIFUGAL PUMP Component Materials Casing Material: Cast Iron FG 260 Impeller Material: Cast Iron FG 260 Shaft Material: S.S AISI 410 Seal Material: Carbon/Ceramic/NBR/S.S 304 Counter Flange Material: Cast Iron Motor Enclosure Material: Cast Iron with S.S AISI 202 Stator Body Pipework Connection Casing Connection: With Discharge Flanges Connection Type: Threaded - BSP Motor Specifications Phase: 3 Voltage: 380-415V Note: Component materials specified in this quote are only for major pump component. Kindly refer our Product Catalogue/Brochure for more information. LHM 050-125 (Feed Pump ) 388 Hand Broken Stone Aggregates 63 mm nominal size (Supply of quarried stone, hand breaking into coarse aggregate 63 mm nominal size (passing 80 mm and retained on 50 mm sieve) and stacking as directed) 389 Crushing of stone aggregates 40 mm nominal size (Crushing of stone boulders of 150 mm size in an integrated stone crushing unit of 200 tonnes per hour capacity comprising of primary and secondary crushing units, belt conveyor and vibrating screens to obtain stone aggregates of 40 mm nominal size.) 390 Crushing of stone aggregates 20 mm nominal size (Crushing of stone boulders of 150 mm size in an integrated stone crushing unit of 200 tonnes per hour capacity comprising of primary and secondary crushing units, belt conveyor and vibrating screens to obtain stone aggregates of 20 mm nominal size.) 391 Crushing of stone aggregates 13.2 mm nominal size. (Crushingof stone boulders of 150 mm size in an integrated stone crushingunit of 200 tonnes per hour capacity comprising of primary andsecondary crushing units, belt conveyor and vibrating screens toobtain stone aggregates of 13 mm nominal size.) 392 Sand Filling in Foundation Trenches as per Drawing & Technical Specification 393 Supply and erection ofGalvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Poles with Octagonal Cross Section 9 Mtr. 394 Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap (400 x 88.9 / 114.3 x 3.25 mm) over the existing poles. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Single arm overhang 395 Glowing Coconut Tree with 3m height & metal base material & multicolor lights 396 Supply, Installation, testing & Commissioning of Under Water lights of 30 Watts with IP66 Protection complete in all respect. 397 Supply installation testing & Commissioning ofhigh mast lighting system (as per PLG 07of ILP UKtechinical report no7 of ILE UK /IS:875 Part-1 – 2015//BSEN10025/and IS:2062 )consisting of totally hot dip galvanised by piecewise single dipped method high mast, lantern carriage suitable for up to 12 nos luminaries with welded arm (excluding luminares), mast head frame assembly with full cover, including 1 No. LED 15 Watts aviation obstructionlights, double drum type self sustaining winch, integral power tool accesible from door with padlocking arrangement (winch motor with control circuit) hot dipped galvanised heavy duty pipe lightening finial, Stainless steel 6 mm dia. wire ropes (AISI 316, 7 / 19 costruction 3 no. rope for lantern carrage & 2 no. rope for winch assembly ) foundation bolt, torque limiter,EPR insulated PCP sheathed 5 core x 2.5 Sq.mm trailing cable, including outdoor type control panel for auto on / off, reverse / forward motor operation. The mast is constructed from mild steel plates (as per IS 5986 Gr. 510 ) cut and folded to form a polygonal section, telescopic jointed and welding as per BS 5135.etc. as required on Existing Foundation.(See table P - 03 for specs.) OEM Must haveType test certificate for wind tunnel test .All as per pre approved by Engineer in charge. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .12.5 Mtr HM (in 2 section)suitable for 6 No. Luminaries2 no. rope for lantern carrage & 2 no. rope for winch assembly 398 Providing and Laying RCC Foundation for Octagonal/ Conical Street Light poles, High mast Poles as per Drawing attach at TableP-4with Following Procedure& All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required SizePLB HDPE Pipe& Foundation Bolt with template as per OEM Recommendations.G) Providing and LayingReinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. 399 Providing & Fixing of IK08IP65 protected Top/Bottom mounted LED Post top Luminarie made of single piece constructionpowder coated die cast alluminium housing with UV stabalized Clear / frosted Polycarbonate diffuser andAluminium anodised with sand blast reflector. The System level Luminous efficacy ≥100 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N)and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . Driver current <750mA.Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 3000 lm Post top Luminarie 400 Providing & Fixing ofIK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles,of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R numberhaving efficiency more than 85 % and in compliance to BIS certified and Trade markcertificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10%, driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K±355K.Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 401 High Power LED Flood Light Minimum lumen output 3700 lm 402 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .LED Street Light fixture with Minimum lumen output 11225 lm 403 Providing & Fixing of IK10IP65 protected 600 mm height LED Bollard Luminarie with base platemade of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥90 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N)and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintainedLight output in Cool white or Warm White Colour as per engineers choice. driver current <750mA.Fixture must be in compliance with BIS Standards and Trade mark Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 404 Minimum lumen output 800 lmBollard 405 Providing & Fixing of IK10IP66 / IP67 protected Rectangular shape LED Step Luminarie made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥90 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N)and efficiency > 85%, PF>0.9, THD<10% and input Voltage range of 140-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained . driver current <750mA .Fixture must be in compliance with BIS Standards and Trade mak Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Minimum lumen output 450 lm Step light 406 Providing and fixing of fuse box size 250(H) x 200(W) x 150(D) mmfabricated of 1.6mm MS sheet with hinged cover, dust and vermin proof, rubber gasket, locking arrangement, duly holded with 2 nos pole clamps of 20 mm x 3 mm flat with nut and bolts, complete with anticorrosive treatment, finished with two coat of approved enamel paint. The box shall be provided with 2 / 4 nos copper bus bar 125 x 20 x 3 mm with brass screws suitable supports,earth terminal, inter connection, knock outs for 20 / 25 mm cable gland, 1 no. 6 Amp MCBcomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 407 Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window,PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0sq.mm heavy duty connector, earth terminal,complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .160 mm X 225 mm X 100 mm 408 Supply and erection of PU coated , 6 to 7 mm thick Glass / FibreReinforced Pole (GRP /FRP) made by CNC filament winding machine using thermoset resin polyester/epoxy resin system) having minimum 62% glass content. designed to withstand the maximum wind speed as per IS 875,and Tested for deflection not more than 15% length of pole as per ASTM D 4923, The pole should be in one piece and tapered round in shape, pole shafts shall be providedwith FRP Anchor with suitable MS cated Base with provision for fixing 4 no. foundation bolts( Including cost of Foundation Bolt),ThePole shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension on Existing cement concrete foundation. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 Mtr. Long, Top/ Bottom OD Dia 89/126mm ± 2mm approx. With Base250X250 X 10mm 409 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 410 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Electrolytic grade Aluminium bus bar 6010 grade 411 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Three phase AMP + HZ + PF + KW + KVA + KVAR + KVARH+KWH+DUAL ENERGY+ ENERGY+THD-I, THD-V & RUN HRS 412 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Resin cast wound type CT 413 C T Class 1, Ratio upto 150/5, Burden 5 VA 414 C T Class 1, Ratio 200/5 to 300/5, Burden 10 VA 415 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Red/yellow/Green colour 416 Providing & Fixing offlush head push button actuators IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV,including connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Luminous typeRed , Yellow, Green, Amber 417 Supply and fixing of following accessories for Moulded case circuit breaker (MCCB)compatible to main MCCB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 418 Shunt Trip Release 419 Under Voltage Release 420 Extended Rotary Handle 421 Spreaders upto 125A, 3 Pole MCCB 422 Spreaders for 250A, 4 Pole MCCB 423 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR4 pole MCCB With Thermal Magnetic release 424 up to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 425 250 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 426 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 427 Four pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 428 Double pole MCB(With B/C curve tripping Characteristics) 429 6 A to 32 A rating 430 50/63 A rating 431 Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .One day & week reserve (digital type ) 432 Providing & Fixing of self healing IP20 MPP type shunt capacitor (banks) conforming to IS:13340-41 /IEC :831-1&2 OR IEC : 60831-1& 2 in existing panel or parallel with load terminals , the capacitor shall be fitted with discharge resistors, pressure sensitive disconnector ( PSD ) and shall have dissipation factor less than 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min over current capacity 1.8 times rated current & peak inrush current min. 300 times of rated current, llife expectancy greater than 100000hrs(temp class - 25 D)in 440 V/480 V Capacitor and for 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D)including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Heavy dutyThree phase 480 V, 50 Hzcylindrical type capacitor (Bank) 433 Providing & Fixing of IP54 microprocessor based 3 CT’s for all 3 phasesensing compensationpower factor correction relay Size 139mm x 139 mm, Operating Voltage 415/440 V, IEC / EN 61000-6-(2&4)having 3 CT sensing, sensitivity up to 50 milli amp secondary current , self analysing auto c/k setting according to targeted power factor setting, the relay shall havedigit display unit for display of real power factor, targeted power factor, lag/lead capacitor switching status, alarm output for under current, over current, insufficient compensation, communication interface with RS 485,indication of switching on units, auto/manual status, and shall have over load protection, no volt release , having multi parameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and3 no. Class- 0.5 Cast ResinCT ( refer CT specs in this chapter )for sensing the relay including making coonection with 1.5 Sq.mm copper wire etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .6 to 8 stage 434 Providing & Fixing ofAC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 pole Power contactorswith following AC 3 Rating 435 13 to 25 Amp 436 32 Amp. 437 Providing & Fixing of440 Volt 3 pole capacitor(AC 6 B ) duty contactor with 3 no. early make and post break auxiliary contacts in series with quick discharge damping resistors/ reactors to limit the inrush current as per PWD specification for electrical Works,IS/IEC 60947-4-1 : 2000, insulation voltage 1000V, impulse withstand voltage 8 KV,Din rail mounting type including making connections, testing etc. as required. suitable for following capacity capacitor bank.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 438 up to 6 KVAR 439 10 KVAR 440 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR3 pole MCCB With Thermal Magnetic releaseup to 100 Amp , 10 kA, fixed O/L & fixed S/C setting 441 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRTriple pole MCB(With B/C curve trippingCharacteristics) 6 A to 32 A rating 442 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %,Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure A attached with this BSR4 core 10Sqmm 443 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 444 6.0 Sq. mm4 core 445 16.0 Sq. mm4 core 446 35.0 Sq. mm3.5 core 447 95.0 Sq. mm3.5 core 448 240.0 Sq. mm3.5 core 449 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 450 4 x 6.0 sq.mm 451 3.5 x 35.0 sq.mm 452 3.5 x 95.0 sq.mm 453 3.5 x 240.0 sq.mm 454 Supplying and makingend termination with heavy aluminiumlugs ( Pin / ring type )confirming to IS 8309 -1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 455 6.0 Sq.mm 456 16.0 Sq.mm 457 35.0 Sq.mm 458 50.0 Sq.mm 459 95.0 Sq.mm 460 120.0 Sq.mm 461 240.0 Sq.mm 462 S/F cable route marker with 10cm x 10cm x 5mm thick or 10 cm dia. G.I.plate with inscription thereon, bolted/welded to 35mm x 35mm x 5mm angle iron, 60cm long and fixing the same in ground in C C ( 1:3:6 ) as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 463 P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class750 N,Externally corrugated and having smooth surface insidewith HDPE Coupler, Elbow, Teeat required Depth below the ground for laying cable of followingNominal Outer dia.MFR Test reportfrom NABL accrediated is to be submitted.(Excavation of Earth& Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 464 63mm 465 120 mm 466 160 mm 467 Providing and laying Non Pressure NP-3 classR.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) etc. as required. (Excavation of Earth& Back filling with compaction is to be Paid Extra). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .300 mm dia 468 labour charges for Excavating trenches of required width for pipes dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr.:All kind of Soils 469 Pipe Earthingas per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. B class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 470 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 471 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 25mm x 3mm G.I. ( Hot Dipped) Strip 472 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 6 SWG G.I. ( Hot Dipped) Wire 473 Supply & Laying following size B class ,G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc.for laying earth conductor/ strip / cable in ground/ surface/ recess as required.All as per pre approved by Engineer in charge.(Earth Excavation will be Paid Extra)All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annex ure A attached with this BSR . 15 mm dia. 474 SITC of Radiator Cooled and Turbo charged Silent DG Set (As per latest CPCB emissionnorms) havingspecifications as per A, B, C, D, E, F,G,H & I A) 1500 RPM Diesel Engine conforming to BS:649/5514 of suitable BHP(up to 82.5 kVA 6 cylinder or Below required, 125 kVA & Above ratings 6 cylinder or aboverequired ) capable of taking 10% over loading for one hour after 12 hours of continuous operation.,Dry exhaust mainfold with Hospital grade silencer and catalytic convertor(isolated from main DG chamber),up to 3 M exhaust piping (with LRB insulation & Alum. cladding ) as required .B)AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS/IEC 60034-1. . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled C) CPCB / ARAI approved Standard canopy with Weatherproof, powdercoated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with sidewall fabricated from 1.6 mm CRCA sheet & filled with glasswool (96Kg/m3) / Foam. as per IS8183 the doors of 28/40/50/85mm thick as perrating and fabricated from 1.6mm CRCA sheet packed with accoustic material, All doors/opening are sealed with neoprene /EPDNgaskets. The DG Set has Inbuilt / External in fuel tank to run 6 to 8 Hrs as per OEM standard, with protection and tripping of DG set against temperature of more than 50 degree centigrade.D) Electronic / Mechanical governor, Manual & electric Start ,Batteries with battry charger,Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring like Running Hour, RPM, Low Lube Oil tripping & control system, Panel mounted MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity :E) (i) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA. (ii).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA. (iii)Accoustic glass wool wall thickness should not be less then 100mm forrating above 250 KVA.F) First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department.G) Servicing Contract of DG Set from OEMs Authorised Service Dealer as per OEM guidelines during the DLP period shall be done by contractor including all consumables, actual charges shall be reimbursed to the contractor by End User Department.H) Manufacturer / OEM must have its authorized service dealer in Rajasthan. Which can provide service within 6 Hours of compalint registration. I) DG set will be offered for Inspection and Testing at Manufacturers Works in presence of Departmental Engineers. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 160 KVA at 0.8 pf 415V 50Hz 3-ǿ 475 S I T C of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of Transformer complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 160 KVA 476 Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications A, B, C, D, E. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . A) Double pole structure on 2 no ISMB ( I beam ) of size 150 x 75 mm,10 mtr length using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required.B) Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation.C) 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulatorsD) 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overheadline with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required.E) 3 no 11kv ACSR conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ 477 SITC of Indoor Type Floor mounted metal clad 11 KV, 630 Amps 3 phase, 50 HzVacuum Circuit Breaker (VCB) Panel Fabricated in VCB Manufacturers own Factoryas per IEC 62271-1,100,200 Standard made from Powder painted pre-fabricated, CRCA sheet steel /High quality Aluminium-Zinc (Aluzinc) coated sheet steel. Fabrication shall be done through CNC turret press and CNC bending machine having a rupturing capacity of 500 MVA, 26.3 KA breaking capacity for 3 sec, Internal arc type tested for 26.3KA for 1 sec with AFLR clasificationtotally enclosed with Aluminium bus bar of 630 Amps for each phase, flush front,Horizontal isolation, Horizontal drawouttypewith Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assambly of 3 vaccum interrupters (VCB manufacturers own make) , with each pole individually encapsulated by epoxy insulations to make it dust proofand self - aligning finger type isolating contacts, truck having integral racking with necessary interlocks (for insertion and removing of VCB), manual and automatic motor charged independent closing/ tripping spring , trip free operating mechanism withclosing and tripping push buttons and mechanical breaker. interconnected with HT sleeve bus bar of 630 Amps , Basic Insulation level (BIL) : 28KV (RMS) / 75KV (Peak) and Altiude less than 1000 meters,includingall protection, indication, Operation, monitoring and control and accessories etc. as required. .Factory Tests of VCB panel as per OEMs QAP in its own Manufacturing facility shall be witnessed by department Engineer virtually / Physically. (Cost of RCC Foundation / Steel Structure to be paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Incoming Cum Outgoing Panel comprising of Side cable box & Transformer Auxiliary protection and comprising of following. - VCB 630 Amps . VI of VCB should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT havingRatio : 400-200A/ 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (How ever CT Ratio shall be decided as per load requirement) - VT Ratio: 11KV/1.732/110V/1.732/110V/1.732, -Core 1: 0.5, 20VAshould be floor mounted and to be connected from the back side of the panel. - Numerical relay (should be VCB manufacturers own make) having protections of 50,51, 50N,51N,TCS. The relay shall have programable 4 digital Input , programable 6 Digital Output and programable 4 nos. LED at HMI. - Ammeter with Selectorswitch and Volt meter with Selector switch -Multifunction Meter of Acc Class 0.5, having facility to monitor KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc. - Trip circuit supervision relay (feature of numerical relay) - LR,TNC switch,indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc., Space heaters - Power Pack (230V AC- 110V DC) and 8/12 window Annunciator. 478 SITC of battery bank of min 150 AH capacity comprising SMF/VRLA batteries,FCBC ( Float cum boost charger)suitable for 415V +/-10%, 50 Hz , 1-ǿ / 3 -ǿ Input & 24/ 48 /110 V DC Output Natural Cooled, free standing in Sheet Steel enclosure,SCR controlled , regulation +/-1% , Efficiency > 75% on FLAC/ DC Instruments, Selector Switch ,Built in DC Distribution Board (6 No MCB), indication , control as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 479 SITC of HT metering cubical panel as approved By DISCOMs fabricated out of 18 SWG CRCA sheet steel in two compartment & MS angle of size 60mmX 6mm having provision for Following: (i)Provision for fixing Trivector / Import - Export Meter (To be supplied by DISCOMs) (ii)Provision for fixing of combined CT PT Set with Copper strip for Connection (To be supplied by DISCOMs), (iii)Test terminal Block, (iv) 6mm thick Bakelite sheet on all sides, (V) 3/6 corex 1.5 / 2.5 Sq.mm copper cable for interconnections,etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 480 Providing and fixing welded mesh/expanded metal mesh 25 mmx 25 mm x 3mm in frame work, flat iron beading 20x3mm including top cross laps inside and out sides welding, iron bolts, crews, clips etc. including two coat of red oxide and two coat of enamel paint or more requiredcomplete with frame work with 50 X 50 X 6mm angle iron post 30 cm in ground embeded in cement concrete 1:3:6 (30X30X45cm) at corner and every three mtr including painting with one coat of primer and two coat of enamel paint work will be done as per direction of engineer incharge of sizecomplete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 481 Gravelling of Transformer / RMU Yard with 100 mm Height Gravels of Size 20 to 25 mmincluding leveling, Dressing etc. as Required. 482 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .3 core 120.0 Sq.mm 483 Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kitsuitable for11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streightthrough joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Crosslinking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. includingtesting etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 484 11 KV End Termination Kit Indoor type 3 core 120/150/185 Sq.mm 485 11 KV End Termination Kit Outdoor type 3 core 120 Sq.mm 486 Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthingmounted on Aluminium/GI structure of suitable strength with followincomponents complete as required:a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. SolaPhotovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watcapacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugand other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPinsulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along witsupplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 487 Supply, Installation, Testing and Commissioning of offgrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthingmounted on Aluminium/GI structure of suitable strength with followincomponents complete as required:a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. SolaPhotovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watcapacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugand other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPinsulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along witsupplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. 488 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSRShort point (up to 3 mtr.) 489 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR 490 On board 491 Short point (up to 3 mtr.) 492 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 493 20 mm 494 25 mm 495 32 mm 496 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 497 3x 1.5 sq.mm 498 2 x 2.5 sq.mm 499 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 500 Supplying and drawing coaxial cable 75 ohm impedance with foam PE insulated solid bare copper inner conductor, and Ist outer conductor of bonded alum. tape and second outer conductor ofalum. alloy braidin existingsurface or recessed conduit/casing capping including making connections as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 501 RG - 6 502 RG -11 503 Supplying and drawing PE Insulated & PVC Sheathed unarmoured telephone cable with 0.5 mm dia. Solid Annealed electrolytic grade bare Copper Conductor as per IS: 8130/84 &confirming to TEC specification GR / WIR/06-03 March 2002in existingsurface or recessed conduit/casing capping. including ferruling on each pair for Identification etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR2 pair 504 P/Laying ISI marked P.V.C. insulated submersible cable confirming to(IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen freefor less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,existing pipe / open trench / Cable tray / on surface including making connection etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 4.0 Sq.mm 3 core flat / Round 505 P & F 1.2mm thickM.S. Recessed fan box, hexagonal/ round of size 130 mm dia, depth 75mm,12 mm dia rod fan hook with 100 mmlength extended on each side . All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 506 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics6 A to 32 A rating 507 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRMetal door (single phase) IK-09 and IP-43 with Metal end box8 Way (8+2) 508 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 509 16 A one way switch With LedIndicator 510 16 Amp.2 Moduleswitch With LedIndicator 511 25 Amp.2 Moduleswitch With LedIndicator 512 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 513 6 A3/5 pin shuttered socket 514 6/16 Ashuttered socket 515 25 Amp. 2 Module Socket 516 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR5 step fan regulator 2 Module 360 dgree rotating 517 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 518 RJ-11 telephone jack singleline 519 RJ-11 telephone jack Double line 520 USB Charger 1 A - 1 M with BIS mark 521 RJ-45, Cat 6 computer jack with shutter 522 T.V. coaxial socket 523 Blanking plate 524 25 Amp. 2 Module Motor Starter with on / off Push button 525 LED Skirting /Foot Light 2 Module 526 Electronic Chime/Buzzer 2M 527 Modular MCB 6 A to 32 ASP 528 Modular MCB 6 A to 32 ADP 529 Providing & Fixing offollowing size mounting grid plates with cover plates made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 530 1/2 Module 531 3 Module 532 P & F of Direct on line (DOL) / Star - Delta Starter as per IEC type-2 Co-ordination chart of OEM in Existing Panel withcircuit breaker having inbuilt overload protection or separate thermal Overload relay, Short circuit, phase loss protection, suitable Contactors, including wiring between switchgears, Indicating lamps for R,Y,B,ON,OFF,Push button for ON, OFF, Volt meter, Ammeter, selector switch for local/remote, auto/manual/OFF operation. Cast resin CTs,provision for potential free contacts making connection, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Direct on line (DOL) Starterwith following Motor ratingMotor rating 2.2 KW 533 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %,Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810. For additional technical parameters of product / work refer Annexure A attached with this BSR6.0 Sq. mm4 core 534 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .2 x 6.0 sq.mm 535 Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Up to 457 mm size 536 Installation , testing and Commissioning of ceiling fan (any size) including wiring the down rod up to 30 cm with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .With regulator 537 Providing & Fixing ofof BLDC Technologyventilating fans , single phase with PVC impeller, ABS body, Double Ball bearing, automatic back lower shutterincluding making connection, testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .250 mm sweep with Min. Air delivery 1150 cmh, 1300 RPM 538 Providing & Fixing of energy efficient direct fit (Retrofit)Polycarbonate/ GlasshousingSMD Mid Power LED tube rod(with integral driver & alumn. heat sink ), on existing fixture.system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum35000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 539 600mm , Min. Lumens output 1800 lmLED Tube rod with Polycarbonate Housing 540 1200mm , Min. Lumens output 2000 lmLED Tube rod with Polycarbonate Housing 541 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Recessed Mounting 542 Minimum lumen output 1300 lm 543 Minimum lumen output 1600 lm 544 Labour charges for installation of submersible motor pump set including lowering/ delowering of pipes, cables, accessories etc. in tube-well/ open well complete including T&P, transportation of tripod, chain pulley block & any other material required for this purpose complete in all respect. Delowering and Lowering 545 Supply & fixing of PVC threaded casing pipes for Tube well (IS 12818:1992) of3mtr. Each for depth up to 1200 ft. Plain and strainer Casing CS for Depth upto 400ft. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Up to 400 ft Depth 150 mm dia 546 SITC of Single Stage, water cooled, High Speed (2880 RPM), Horizontal, Centrifugal, Openwell Submersible pumps set pre filled with coolent water and fitted with mechanical seal - T/C Vs T/C, Thrust bearing shall be ofcarbon + S.S.The stator body of single phase pumpshall be of SS and rest of all shall be of cast iron. All casting parts should be cathod electro deposition (CED) coated and other construction material should be confirming to IS : 14220: 2018 . The overall performance of pump shall confirm to BEE energy efficiency level of 3 star. Valid BEE certificate from OEM must be submitted for the same. Motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011, including making connection etc as required complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 547 5.0 HP, 3-Ø, (14 -28) Mtr, (995-500) LPM 548 10.0 HP, 3-Ø, (22 -36) Mtr, (1860 - 1020) LPM 549 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 550 5.0 HP, 3-Ø, (24-44)Mtr, (680-370) LPM 551 10.0 HP, 3-Ø, 32- 48)Mtr, (830-450) LPM 552 SITC of ContactorOEM Fabricated DOL/Star-Delta Starter panel with switchgear selection as per Type-2 Cordinatiom Chart andmade out from 1.6 mm thick powder coated CRCA sheet, enclosure comprising of over load protection relay, short circuit & single phasing protection, Illuminated ON / OFFpush buttons,ammeter, voltmeter, indicating lamps etc.suitable for following rating motors complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 553 3.0 HP to 5.0 HP ( Star / Delta starter ) 554 7.5 HP to 10.0 HP( Star / Delta starter ) 555 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Recessed Mounting.Minimum lumen output 1600 lm 556 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSRSingle pole MCB (With B/C curve tripping Characteristics) 6 A to 32 A rating 557 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 558 6 A3/5 pin shuttered socket 559 6/16 Ashuttered socket 560 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / SqaureSMD Mid Power LED Downlight with power coated die-cast aluminum housingwith UV Stabilized non yellowish Diffuser withBIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80,life time of minimum50000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing.OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Recessed Mounting.Minimum lumen output 1600 lm 561 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with HDPE, U/UTP (Unscreened/Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Outdoor Cable as per latest ammendments of ANSI/TIA/EIA-568 C.2 & ISO/IEC 11801 2nd Ed, The copper conductors should be balanced twisted in pairs, seperated by a cross divider & protected by LSZH PVC outer jacket of UV resistant. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. Should meet IEEE 802.3af & IEEE 802.3at for POE applications. Cable Should support Ethernet 10GBASE-T according to the standards. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 562 1 Run of Cable 563 Supplying, installing, testing and commissioning of 24 port CAT6 jack panel loaded as per the connections required in jack panel. 564 Supplying, installing, testing and commissioning of 16 port CAT6 jack panel loaded as per the connections required in jack panel. 565 Supply and Installation of unsheilded/360 degree sheilded Information outlets made of high impact plastic body with ABS, FR Grade halogen free material with provision for protection against dust in jack, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact termination on reliable copper tin plated Insulation displacement contact, with easy lock mechanism, It supports IEC 60603-7-4 and complied with ANSI/TIA/EIA 568 C.2 standard. jack should be RJ11,RJ12 & RJ45 compatible. Should support Ethernet 1.2 Gb/s ATM,Digital video and broadband/baseband analog video, Voice over internet protocal (VOIP) Specifications in existing modular/MS Boxes along with necessory connections as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .Cat 6, Un-sheilded Information Outlet 566 Supply, Drawing and Testing, of stranded Multi mode (50/125 μm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR .12 Fiber 567 Supply, Installation, Testing and Commissioning of Wall mounted ISO 9001:2015 &14001 or higher level certified company made Communication enclosure (Rack) of Minimum 500 MM Depth with made from CRCA & hot dip powder coated, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 2 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with fastner of suitable capcity etc as required complete in all respect. All as per pre approved by Engineer in charge . 6 U wall mounted Enclosurecharge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 568 Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 569 Supply , Installation, Testing and Comissioning of Hot pluggable Small Form Factor Pluggable (SFP Module), 1000BASE-SX, 1.25/2.125G Fiber Channel, LC Type Duplex Connector, 850nm laser transmitter, Should support distance upto 500m on 50/125um of data rate upto 2.125 Gb/s on bi-directional data links. Should also support industrial temperature, should have metal enclosure for lower EMI. The transceiver should be ROHS Compliant. (For Each MM Fiber) all switches & related Fiber modules should be of same make & category for seamless integration with each other of Enterprise class, complete in all respect.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 570 SITC of 2 MP IR Fixed Dome Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 571 SITC of 2 MP IR Fixed Bullet Network Camera -1/2.7″ Progressive Scan CMOS, 1920 × 1080 at 25fps, 2.8 mm Fixed lens, 0.002Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Video tampering, UL, CE, FCC certified. 572 SITC of16 channel Network Video StoragE NVR suitabe to access data from any remote location including backup drive for 30days. 573 Supply, Installation, Testing & Commissioning of i7 CPU with latest generation windows 10 and above, 1TB SSD and 500GB RAM. 574 Supply, Installation, Testing & Commissioning of CCTV Client Operator Station with 1 No.of 55” LED Display -Complete as per specifications & preferred make. Make: SONY/Samsung/LG 575 Supplying, installing, testing and commissioning of HDMI to HDMI Cable. 576 Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6Apatch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectorsas per ANSI/TIA/EIA 568 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568, minimum requirement for 1G BASE-T/ 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes,Minimum 750 to 1000 mating cycles in plug contacts for long durability complete in all respect. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR. 577 Cat 6, U/UTP (Unscreened/Un-sheilded Twisted Pair) Patch Cord.3Mtr 578 Supply installation testing and commissioning of 1KVA online UPS. 579 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm Dia.FIRE FIGHTING WORK 580 Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipes conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applicationsincluding cutting, screwing, welding etc. & forged steel fittings like elbows, tees, tapers, reducer, gaskets etc. fixing the pipe on the wall/ceiling with suitable clamps, hanger and nuts bolts including cutting hole and chase in brick or RCC walls/ slab and making good the same. complete with painting of one coats of Red Oxide and two or more coats of synthetic enamel paint of requiredshade complete as required. (Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs.). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 581 25 mm dia 582 50mm dia 583 80 mm dia 584 100 mm dia 585 150 mm dia 586 Providing, Fixing, Jointing, Testing & Commissioning of Heavy duty MS C class (Heavy) pipe conforming to IS 3589 / 1239 part-I for hydrant and sprinkler applications in Existing trench with cement concrete block as supportsincluding cutting,welding etc & forged steel fittings like elbows, tees,tapers, reducer with cleaning,wrapping and coating of the pipe with 4 mm thick tar based polymaric corrosion protection tape including applying uniform coat of cold pipekot primer as per IS; 10221 for protection against corrosion complete in all respect. ( Pipe to be tested @ 10Kgf/Sqcm for 2 Hrs. & Excavation of Trench and refilling of trench to be paid extra). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 587 100 mm dia 588 150 mm dia 589 Supplying and Fixing of PN 16 Flanged Y strainer fabricated out of cast iron body, SS 304 strainer with perforated screen with 3 mm. dia holesin existing MS / GI pipe complete with 2 no. Matching Flanges (Minimum 16 mm thick),nuts, bolts, washers, gaskets etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 150 mm dia 590 Supplying and Fixing of PN 16 Cast Iron Dual Plate Wafer Type Check Valve / Non return valve with SS / Bronze flap complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 591 150 mmdia 592 Supplying and Fixing of PN 1.6Butterfly Valve (Wafer Type) with S.G Iron Disc and confirming to IS:13095 complete with 2 no. Matching Flanges (Minimum 16 mm thick), nuts, bolts, washers, gaskets,etc as required of following sizes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 593 80 mm dia 594 150mm dia 595 Supplying and Fixing of PN 16 Brass/GM Ball valves with screwed end, SS Ball including teflon tape etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 596 20 mm dia. 597 25 mm dia. 598 32 mm dia 599 50 mm dia 600 Supplying and Fixing of Brass/GM gate valves with screwed end , Non rising stem and conforming to IS:778 Class-1 including teflon tape etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 601 20 mm dia. 602 25 mm dia. 603 Supplying and fixing of SS 304 Single / Double headed oblique pattern hydrant landing valve (internal/external) with 75 / 100 mm dia flanged inlet & 63 mm dia instantaneous type female outlet coupling with cast iron wheel complete with ABS cap and chain and all accessories as per IS:5290-93 (Type-A) in cluding matching flange (14 mm thick),nuts, bolts, washers, gaskets,etc as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . Single Headed with 75 mm Dia. Flanged Inlet 604 Supplying and fixing of flexible hose made with 100% polyester, black EPDM internal rubber lining with External coat of synthetic elastomer (IS:636, type-A)63 mm dia, 15 mtr. Long RRL hose pipe with instanteneous type 63 mm dia SS-304male and female couplings(IS:903) duly bound and riveted to hose pipes with copper rivets and SS wire etc. as required.Appropriate Test Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. 605 Supplying & fixing SS-304 Short Branch Pipeconforming to IS: 903:93 fitted with 20mm (nominal internal diameter)bore nozzle, for projecting water in form of solid jet. The Branch shall have 63mm Male Instantaneous Inlet, suitable for use with 63 mm size Fire fighting hoses. H.P. tested to 21 kgf/cm² for 2.5 minutes. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 606 Supplying and fixing first -Aid Fire hose reel Drum wall mounted swinging type with MS construction powder painted in post office Red, conforming to IS 884-1985 with upto date amendments, complete with the following as required.(A) Thermoplastic / Rubber Hose(B)20 mmdia UL, FM Bronze / SS nozzle with 5mm orifice (C)Drum and brackets for fixing the equipments on wall.(D) Connections from riser with 20/25 mm dia Brass/GM gate valves with screwed end and conforming to IS:778 Class-1through Forged steel Screwed Union & M.S. pipe. Etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . With 30 m x 20 mm Thermoplastic hose as per IS:12585 Type-2 and Bursting pressure 42 Kg/sqcmWith 30 m x 20 mm Thermoplastic hose as per IS:12585 Type-2 and Bursting pressure 42 Kg/sqcm 607 Supplying and fixing of 750 mm x 600 mm x 250 mm Outdoor application Fire Hose Cabinet made of 1.6 mm thick MS sheetDuly powder coated in red color externally and white internally with 6 mm thick glazeddoors with Expanded Metal 2 mm thick Jali including necessary locking arrangement suitable to accommodate 2 Nos 15 Mtr. Long RRL Hose and 1 No. branch pipe on Existing Wall / Angle Iron Frame as required. (Cost of MS structure for mounting Frame is to be Paid Extra) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 608 Supply & Fixing of Fire Mans Axe with carbon steel head & rubber moulde handel usable upto 20 KV and confirming to IS :926 with length approx 0.4 M & weight 3.0 Kg. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 609 Supplying, Installation, Testing & Commissioning ofElectrical Driven fire fighting duty Jockey pump as per TAC andIS 12469-1988., Factory assembledin Pump make OEMsuitable for automatic operation and consisting of following details given asA, B, C, D, E,F and G.(A) Horizontal End suction Single / Multi Stage Centrifugal Back pull type pump complete for delivery of below mentioned discharge and Head.(B) Material of construction : Pump Casing - Cast Iron, Impellor- Bronze, Shaft - SS 410, Packing - Mechanical Seal.(C) Squirrel cage induction motor (IE-3 Class) suitable for 3 phase, 415 V, 50 HZ, Ac supply , Class -F Insulation, Synchronous speed not Exceeding 2900 RPM, T.E.F.C confirming to IP:55 , of required HP suitable for the above pump ,along with flexible (Love Joy type) coupling , coupling guard complete in all respect .(D)Common bed plate fabricated frommild steel channel for installation of pump and Motor including anti vibration pads.(E) The Hydrostatic tests (2 times of design operating head or 1.5 times the shut off head whichever is higher) and performance tests (to determine developed head, Pump BHP and efficiency v/s Flow) of pumps along with trip test shall be carried out at manufacturer’s works in Virtual / Physical presence of Department’s representatives.(F) Physical & Chemical Test reports of i) Pump casing (ii) Impeller (iii) Shaft (iv) Shaft sleeveand Dynamic Balance certificate is to be submitted by OEM(G)Suitable size Reinforced cementconcrete (M-30) foundation with foundation bolt, Nozing Angle of size 40mm x40mm x5 mm ( Cost of RCC Foundation to be paid Extra ) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 180 LPM suitable for 88 Mtr Multi Stage 610 P & F of Direct on line (DOL) / Star - Delta Starter as per IEC type-2 Co-ordination chart of OEM in Existing Panel withcircuit breaker having inbuilt overload protection or separate thermal Overload relay, Short circuit, phase loss protection, suitable Contactors, including wiring between switchgears, Indicating lamps for R,Y,B,ON,OFF,Push button for ON, OFF, Volt meter, Ammeter, selector switch for local/remote, auto/manual/OFF operation. Cast resin CTs,provision for potential free contacts making connection, testing etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR .Star - Delta Starterwith following Motor rating 22.0 KW 611 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 20mm x 3mm copper strip 612 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 35.0 Sq. mm 3.5 core 613 Electrical Connection Work