Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Refurbishment of Civil Work of 25m, 50m, final Range Building:-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingthe excavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingas directed,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 3.00 m.) By Manual MeansSpec. No.:- Bd.A.1 Page Number 259 |
| 2 | Excavation for foundation in hard murum including removing the excavated material upto a distanceof50 metresbeyondthebuildingareaandstackingandspreadingasdirected, dewatering,preparingthebed forthefoundation andnecessary backfilling, ramming, wateringincluding shoring and strutting etc. complete.(Liftfrom 1.5to 3.0m)By Manual MeansSpec. No.:- Bd.A.1 Page No.259 |
| 3 | Removing brickbatcoba including stackingthe spoilsasdirectedwithallleads,liftsetc, complete.Spec. No.:- As directed by Engineer in charge. |
| 4 | Removingdoorsandwindowswithframesandstackingthematerialsasdirectedwithall leads, lifts etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 5 | Dismantling brick masonry in lime orcement mortar and stackingthematerils as directedwithallleads, lifts etc.Spec. No.:- As directed by Engineer in charge. |
| 6 | Removing cement tiles, or marble or polishedshahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. completeSpec. No.:- As directed by Engineer in charge. |
| 7 | Removing urinal pans or wash hand basins with frame including disconnecting the sanitary andwatersupply connections,removingthesamecarefullyandstackingtheserviceable materialsasandwheredirected includingthrowingtheunserviceablematerialsoutsideetc completeSpec. No.:- As directed by Engineer in charge. |
| 8 | RemovingW.C.pansincludingdisconnectingthesanitaryandwatersupplyconnections, removing and breaking flooring and bed con-crete around pan removingthe same carefully and stackingtheserviceable materialsasadn wheredirected includingthrowingthe unserviceablemateriaslsoutsideetc.carefully andthrowingouttherefusaloutsideetc. complete.Spec. No.:- As directed by Engineer in charge. |
| 9 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-I) to the soil along the external face of building by punching holes of 1.2 of 1.5 C.M. diametre about 30 -60 cm deep at15cmc/casclosetothe wallaspossibleandtoinject0.5percentof aldrinor clorophyrifosatthe rate of7.5litresperhole andsealing the same withproper filling and covering 10 years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 10 | Transportation of excavated & debris from site to disposing site inluding loading , unloading & tranportation etc. complete. (lead 3km) |
| 11 | ProvidingAutoclavedAeratedConcreteBlockmasonaryof conforming to IS:2185 (Part 3) - 1984 in extra fine jointing mortar of fixoblock of UltraTech or equivalent in superstructure including striking joints, raking out joints and scaffolding etc. Complete. (The test shall be carried out conforming to IS:6441 (Part I) - 1972)Spec. No.:- As directed by engineer in charge |
| 12 | Providing internal cementplaster 6 mm thickina single coat incement mortar 1:3 withoutneeru finish to concrete surface in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd.L.1 Page Number 367 |
| 13 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.2 Page Number 368 |
| 14 | Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.10, Page Number370 |
| 15 | Providingsandfacedplasterexternallyincementmortarusingapprovedscreenedsand,inallpositions including base coat of 15 mm thick in cement mortar 1:4 using waterproofingcompoundat 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoat roughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurface bytakingoutgrainsandcuringforfourteendays scaffolding etc.complete.Spec. No.:- Bd.L.7 Page Number 369 |
| 16 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622- 2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring Spec.No.:- Bd.M. 12 Page No.385 |
| 17 | Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.b) Skirting /dado, Spec.No.:- Bd.M. 12 Page No.385 |
| 18 | Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring Spec.No.:- Bd.M.12 Page No. 385 |
| 19 | Providing and laying vitrified mattfinish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. b) Skirting /dado, Spec.No.:- Bd.M.12 Page No. 385 |
| 20 | Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / OceanBrown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. Spec.No.:- Bd.M. 3 B/Page No. 380 |
| 21 | Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosingthe sharp edges wherever necessary, curing,etc. complete. Spec.No.:- As directed by Engineer-In- Charge |
| 22 | Providing and fixing machine cut machine polished 18 mm to 20 mm thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaningetc. complete. Spec.No.:- Bd. M.22 B/Page No. 390 |
| 23 | Providingand fixingmachinecut mirror polished 18 mm to 20 mm thick telephoneblack granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with full moulding the edges etc.complete . Both side polishSpec. No.:- Bd.M.35 B/Page Number393 |
| 24 | Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1 Kg per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. Spec.No.:- As directed by Engineer in charge.a) Second floor & terrace |
| 25 | Providing water proofing in W.C. and bath including brick bat coba in all position including providing and laying 12 mm bedding in cement mortor 1:3 on vergin concrete slab with water proofing compound @1 kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with water proofing compound 1 kg/bag of cement grouting and finishing the top layer with 20 mm thick brick bedding in cm mortor 1:3 with water proofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years\" guarantee on requisite stamp paper including curing etc. complete .Spec. No.: As directed by Engineer-in-charge |
| 26 | ProvidingwaterproofplasterinW.C.andbath 12mmthickfordadoincementmortar1:3withneat finishing, floating using waterproofing compoundat the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete.(Excluding Tiles) (As directed by Engineer in Charge)Spec. No.:- As directed by Engineer in charge. |
| 27 | Solid Core Flush door Single leafProvidingandfixingfactorymadesolid coreflushdoorinsingleleaf35mmthick,decorative types,of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face Laminet WP on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessarybeads,moulding andlipping,holdfasts,matfinishstainlesssteelfixturesfastenings,finishing withfrench-polish/waxingcomplete.(withoutdoorframe).(SampletobegotapprovedfromEx.Engineer before use) Commercial Hard Wood shutterSpec. No.:- As directed by Engineer-in-charge |
| 28 | Solid Core Flush door Double leafProviding and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type ofexterior grade, as per detailed drawings,conforming to I.S.: 2202 1966(Revised) including approved face laminet WP onbothsides,withoutglazing andvenetiansincludingmatfinishstainlesssteel fixturesand fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutterSpec. No.:- As directed by Engineer-in-charge |
| 29 | ProvidingandfixingM.S.grilldoor24Kilogram/SquareMetreofvarioussizeasperdetaileddrawings without hot dip coating, iron fixtures and fastenings and 3 coats of oil painting etcSpec. No.:- As directed by Engineer in charge. |
| 30 | Providing andfixing inposition(asper1868/1982)Aluminium sliding windowofthree tracks with rectangularpipe95x38.10x0.90mm atweight0.637Kilogram/Running metre.withwindowframe bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/Running metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Runningmetre.Theshuttershouldbe ofbearingbottom40x18x1.25mmat weight 0.417Kilogram/Running metre.Inter locking section 40x 18x 1.10mm atweight 0.469Kilogram/Runningmetre.andhandleandtopsection40x18x1.25mm atweight o.417Kilogram/Runningmetre.Asperdetaileddrawingsandasdirectedby EngineerinchargewithallnecessaryAluminiumsectionsfixturesandfasteningssuchasrollerbearingin nylon casting and self locking catch fitted in vertical section of shutter including 5 mmthickplainglassand aluminiummosquitonetshutterwithstainlesssteeljailwithall required screws and nuts etc, complete. With powder coating with boxSpec. No.:- As directed by Engineer in charge. |
| 31 | Providing andfixing inposition powder coated aluminium louvered windows/ ventilatorof various sizes withpowdercoatingasperdetaileddrawingandspecificationsincluding aluminiumframes80x38 mmx1.22mmboxtype,5mmthicksheetglasslouvers,of approved quality etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 32 | Providing and fixing false ceiling of 12mm thickas per drawings including powder coated G.I. wall angle of 20mm x 20mm size, G.I. gridrunners of size 20mm x 38mm at 600mm centertocenterbothwaysand suspended using G.I. 3mm wire including fixing usingbutterfly clips and fasteners including transporting,scaffoldingallnecessarylabourand machinery, finishing etc. complete.Spec. No.:- Bd. R. 19 Page Number 462 |
| 33 | Providing and Fixing of GI Lay in Plain metal ceiling consisting of 600x600mm Lay in tiles of pre coated galvanized steel in 0.5 mm thickness in Global white color tile to be laid ongrid systeM.S. Hostel A with 15mm wide T - sectionflangescolorwhitehavingrotarystitchingontheMainRunner,1200 mmand 600mmCross Tees.Providing andFixing of GI Lay in Plainmetal ceilingconsistingof600x600mmLayintilesofpre coated galvanized steel in 0.5 mm thicknessinGlobalwhitecolor tile to be laidongrid systeM.S. Hostel Awith 15mm wide T - section flanges color white having rotary stitching on the MainRunner, 1200 mm and 600 mm Cross Tees.products approved as per GRIHA and BS 476 etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 34 | Providing and applying two coat of pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylic wall putti etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 35 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plasteredsurfaces includingscaffoldingifnecessary,preparing the surface bythoroughlycleaningoil,grease,dirtandother foreign matter and sand papering as required etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 36 | Providingand applyingtwocoatsof exterioracraylicemulsion paintconfirmingto corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces includingcleaning,preparingthe plastersurface,applyingprimercoat,scaffoldingif necessary , and watering the surface for two days etc complete.Spec. No.:- As directed by Engineer in charge. |
| 37 | Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/Square Metreasper drawingincludingfixturesnecessaryweldingandpaintingwithonecoatof anticorrosive paint and two coats of oil painting complete.Spec. No.:- Bd.U.1 Page Number 537 |
| 38 | Providing and fixing white european type wall-hung, of size 360mm x 360mm x 575mm with flushvalveof approvedmake includingsoilpipe, ventpipeuptooutsidefaceofwall,100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge.Spec. No.:- As directed by Engineer in charge |
| 39 | ProvidingandfixingwhiteglazedearthenwareWashHandBasinof55cm.x40cm.size including coldwaterpillartap/coldandhotwaterpillartapbrackets,rubberplugsandbrasschain,stoptapand necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete.Spec. No.:- Bd.V.30 Page Number 565 |
| 40 | providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and ofspecialcolour shadehavingtelephonicblack /coloured graniteof 180mm thickstone blackkadappaframework includingchromiumplatedcouplingbottle-TrapusingCERA companyorequivalentovaltypawash basinmodelno 3448asperdetaileddrawing oras directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m )Spec. No.:- As directed by Engineer in charge |
| 41 | Providing andfixing 450mm x550mm size superiortype Belgium mirrorwith16mmdia. nickel plated towel rod etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 42 | Providing and fixing C.P.Two way BIB cock of approved make continentalincludingnecessary sockets/union nut etc. complete.Spec. No.:- As directed by Engineer in charge |
| 43 | Providingandfixing Handshower(healthfaucet)with8mmdia.1mlongflexibletube having wall hook withapprovedmake including necessary sockets/ unionnut etc. complete as directed by Engineer in charge.Spec. No.:- As directed by Engineer in charge |
| 44 | Providing andconstructing granite kitchenplatform withfixing of stainlesssteelsink 600 mm x 450mm sizeasperdetailed drawingincludingverticalboth sidepolished kadappahstone25to30mmthick supportswithkadappah top35to 40mm thickandpolishedgranite16to20mm topwithside stripsof granite at front and both sides of platform raised with two verticalgranitesupports15cmheightandtop graniteof75x40cmincludingcutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size __ m x 0.60 m and height is 0.75 m)Spec. No.:- As directed by Engineer in charge. |
| 45 | Providingandfixingstainlesssteelsinkofsize600x510x200mm incluidngcoupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete.Spec. No.:- As directed by Engineer in charge |
| 46 | Providing and fixing C.P. sink cock with raised J\" shaped swinging casted spout of approved make including necessary sockets/ union nut etc. complete.\"Spec. No.:- As directed by Engineer in charge |
| 47 | Providing andfixing 10cm C.I.NahaniTrapincludingC.I.gratingbendandpiece ofC.I. pipe upto the outside face of the wall complete.Spec. No.:- Bd.V.32 Page Number567 |
| 48 | Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in charge |
| 49 | Providing andfixing onwalls/ceiling/floor 20mm dia.CPVC pipe withnecessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in charge |
| 50 | Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in charge |
| 51 | Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in charge |
| 52 | Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- BD.V 5 page 551 and as directed by Engineer in charge |
| 53 | Providingandfixingonwalls/ceiling/floors,25mmdia.heavygradehavingembossedasISI Mark galvanised iron pipes weight of 3.01 Kilogram/meter with necessary fittings .remakinggoodthe demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- Bd.V.5 Page Number 551 |
| 54 | Providingandfixingonwalls/ceiling/floors,32mmdia.heavygradehavingembossedasISI Mark galvanised iron pipes weight of 3.89 Kilogram/meter with necessary fittings .remakinggoodthe demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.Spec. No.:- Bd.V.5 Page Number 551 |
| 55 | Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. /soil vent/waste pipe and withnecessary fixtures andfitting such as bends, tees, single junctions, slotted vent, clamps etc. completeSpec. No.:- As directed by Engineer in charge. |
| 56 | Providing and fixing 100 mm dia stabiliser pipe/ P.V.C./ soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec.No.:- As directed by Engineer in charge. |
| 57 | ProvidingandfixingP.V.C.Rainwaterpipesof110mmouterdiameterandhavingwall thicknessof 2.2to2.7mmconfirmingtoI.S.13592-1992 includingproperrainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket withsolventcementand properlyrestingtheshoeofpipesonC.C.or masonryblocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. Allthe P.V.C. fittings andadditional 2piece socket clipsshall be gotapprovedfrom engineerin charge etc. complete.Spec. No.:- As directed by Engineer Incharge |
| 58 | Providing and fixing H.D.P container one piece moulded water tank made out oflowdensitypolythylerand builtcorrugationincludingofdeliveryuptodestination hoisting andfixing of accessories such as inlet, outlet overflow of alltanks capacityabove 1000 to 20,000 litresSpec. No.:- As directed by engineer-in- charge. |
| 59 | Providing and fixing 40mm.dia Ball cockmedium typewithPVCfloat including sockets andnecessary fittings and tested as per municipal requirements etc. complete.Spec. No.:- As directed by Engineer in charge. A. Second Floor |
| 60 | Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. Spec.No.:- Bd.V.9 Page No. 555a)Second Floor |
| 61 | Providingandfixing15cmx10cmsaltglazedstonewaregullytrapincementconcrete1:4:8outsidethe buildingincludingcastirongrating inthe sink,connecting glazedstoneware pipe,brick masonrychamber with cast iron lid and cast iron grating for the gully trap.Spec. No.:- Bd.V.38, Page Number 572 |
| 62 | Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and withframe fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete. Spec.No.:- Bd.V.43, Page No. 574 |
| 63 | ProvidingandconstructingBrickMasonryInspectionChamber90cmx45cmx90cm including1:4:8 cement concrete foundation 1:2:4 cement concrete channels half roundG.S.W.pipes,BrickMasonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.Spec. No.:- Bd.V.43, Page Number 574 |
| 64 | ProvidingandconstructingBrickMasonryinspectiontrapChamber90cmx45cmincluding1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, saltglazed stone-ware interceptingtrapwithroddingpipesetin1:4:8cementconcreteblock, brickmasonryplasteringinside andOutside,fixedincementconcretewithR.C.C.Cover medium duty 140 Kilogram. etc completeSpec. No.:- Bd.V.44, Page Number 575 |
| 65 | Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec.No.:- Bd.V.41, Page No. 573 |
| 66 | Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec.No.:- Bd.V.41, Page No. 573 |
| 67 | Providing andfixingreinforcedcementconcrete coverofsize 60cm x45cm withframe overinspection chamber etc. complete.Medium duty (100 Kilogram)Spec. No.:- As directed by Engineer in charge. |
| 68 | ProvidingandfixingC.P.Angularstopclockwithwallflangeofapprovedmakecontinentalincluding necessary sockets/union nut etc. complete.Spec. No.:- As directed by Engineer in charge |
| 69 | Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete.Spec. No.:- Bd.V. 12 Page Number 556 |
| 70 | Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bendpipeand wallflangeofapprovedmakeincludingnecessarysockets/unionnutetc. complete.Spec. No.:- As directed by Engineer in charge |
| 71 | Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete.Spec. No.:- As directed by Engineer in charge |
| 72 | Removing chockes and leakages from down take G.I/CI/PVC pipe line on walls floor level by using zoola / scaffolding and rectify the same for functioning with all liftsetc. complete.Spec. No.:- As directed by Engineer in charge. |
| 73 | Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 74 | Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 75 | Filling tiles joint portion offlooring and dado filling with white cement by removing existing loose morter/ cement slurry from joint with tools and finish with washing cleaning and curing etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 76 | Open To Sky Area Development-25 meter Building:-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingthe excavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingas directed,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 3.00 m.) By Manual MeansSpec. No.:- Bd.A.1 Page Number 259 |
| 77 | Dismantling brick masonry in lime orcement mortar and stackingthematerils as directedwithallleads, lifts etc.Spec. No.:- As directed by Engineer in charge. |
| 78 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surfaceofplinthfillingattherateof5litresofemulsionconcentrateat1.0percentof clorophyrifosperOne Square Metre of surface area covering ten years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 79 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineerincharge inlayersof15cm to20cmincludingwateringandcompactionetc. complete.Spec. No.:- Bd.A.11 Page One Number 263 |
| 80 | Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete.Spec. No.:- 0 |
| 81 | Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cmthick including hand packing and compacting etc. complete.Spec. No.:- Bd.A. 12 PageOne Number 264 |
| 82 | Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding , Without SCADA |
| 83 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade)Spec. No.:- Bd. E. 1 Page One Number 287 |
| 84 | Providing and fixing Ductile iron man hole cover of light / medium / heavy duty with frame of any size over inspection chamber etc.complete |
| 85 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns,canopies,staircase,newels, chajjas,lintelspardis,copings,fins,archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Spec. No.:- Bd.F.17, Page One Number 306 |
| 86 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.Spec. No.:- As director by engineer in charge and BDG-2 and 5 |
| 87 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. CompleteSpec. No.:- Bd.G.5 Page One Number 315 |
| 88 | Providingsandfacedplasterexternallyincementmortarusingapprovedscreenedsand,inallpositions including base coat of 15 mm thick in cement mortar 1:4 using waterproofingcompoundat 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoat roughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurface bytakingoutgrainsandcuringforfourteendays scaffolding etc.complete.Spec. No.:- Bd.L.7 Page Number 369 |
| 89 | Providing waterproof plaster in W.C. and bath12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete.(Excluding Tiles) (As directed by Engineer in Charge)Spec. No.:- As directed by Engineer in charge. |
| 90 | Providingand applyingtwocoatsof exterioracraylicemulsion paintconfirmingto corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces includingcleaning,preparingtheplastersurface,applyingprimercoat,scaffoldingif necessary , and watering the surface for two days etc complete.Spec. No.:- As directed by Engineer in charge. |
| 91 | Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.Spec. No.:- Bd.V.41, Page One Number 573 |
| 92 | ProvidingandconstructingBrickMasonryInspectionChamber60cmx45cmx90cm including1:4:8cementconcretefoundation1:2:4cementconcretechannelshalfround G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.Spec. No.:- Bd.V.43, Page One Number 574 |
| 93 | ProvidingandconstructingBrickMasonryInspectionChamber90cmx45cmx90cm including1:4:8cementconcretefoundation1:2:4cementconcretechannelshalfround G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.Spec. No.:- Bd.V.43, Page One Number 574 |
| 94 | Providing & Fixing 50 mm ArtificialGrass, thick rubber underside, green grass with yellow strands give realistic look and feel.Spec. No.:- As directed by Engineer in charge. |
| 95 | Interior Work & Acoustical refurbishment of 25 meter Range Building:-Removing cement tiles, or marble or polishedshahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. completeSpec. No.:- As directed by Engineer in charge. |
| 96 | Removing teak wood trellies work with frame including stacking the materials as directed with all leads, lifts etc. complete. |
| 97 | Removingdoorsandwindowswithframesandstackingthematerialsasdirectedwithall leads, lifts etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 98 | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc.complete.Spec. No.:- As directed by Engineer in charge. |
| 99 | Providing antitermite treatment to the wooden frames of doors/windows of the existing building as perI.S.6313(Part-III) bydrilling 6mm dia.holes at four corners on one side and four corners on other side at a down wardangle of about 45 degree at the junction of wood work and masonary and injecting 150ml.of chlorodane 5% W.C.and sealing by filling putty etc. complete covering 2 years guarantee on bond paper. |
| 100 | ProvidingantitermitetreatmenttothesidesofflooringoftheexistingbuildingasperI.S. 6313 (Part-III) by punching holes 6mm dia. drilled at a distance of 30cm. centre to centre and injecting one percentof chlorodane emulsionconcentrate at the rate of50 mlper hole and sealing by filling putty etc. complete covering 2 years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 101 | Providingantitermitetreatmenttothefor interior surfaces of wall surfaces.Scope of Work•Making 3” wide x 9”deep trench along the wall & floor OR Drilling 12 mm diameter holes at the junction of Wall & Floor at 90° angle•Drilling 12 mm diameter holes, 12 inches deep at 1 feet distance C/C•Filling the holes with Termiticide Solution (1lit per hole) OR Applying Termiticide Solution @ 2.25 liter per linear meter in trenches•Filling the holes with cement mortar OR Filling the trenches with soil and treat the top surface with Termiticide Solution @ 1.0 ltr. Per linear meter•Customer is requested to put plinth protectioncomplete covering 2 years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 102 | Transportation of excavated & debris from site to disposing site (lead 3km) |
| 103 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.2 Page Number 368 |
| 104 | Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring. Spec. No.:- BDM 33.28, Page Number 158 |
| 105 | Providing & Fixing in position Acoustical Doors along with 150x150mm teak wood frame, doors made from 50mm Teak wood frame 600x600ctoc filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides,12mm waterproof ply & veneer from both sides, including 150mm heavy duty SShinges (Geze /Dormaoreq.)4no each leaf, with Door-closer (Dorma/ Gezeoreq.) including cost of required Cut-Outs,decorative mouldings/ finishing-items/ melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete |
| 106 | Supply & installation of Anutone Salon Slats Surco made of pinewood E1 grade fiberboard, melamine/veneer laminated finish, groove perforated slats L16-2 - (2mm grooves @16mm pitch with 27% open area) / L32-2 - (2mm grooves @ 32mm centers with 15% open area) surface density 63g/m2,tongue-groove edge for a seamless look, 5-test fire retardant grade, size 128 x2440x16mm, volume density of base board 700Kg/m3, weight 9Kg/m2 (L16), 10.5Kg/m2 (L32), 11Kg/m2 (L64) installed by using Anutone Strut framework system.The Anutone Strut framework system shall include Anutone Strut CC10 thickness 0.55mm, length 3600mm, knurled web 40mm, depth 10mm and equal flanges 15mm is fastened to the wall positioned vertically at every 600mm centres.Anutone Strut CC18,aluminium core cross channel, thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge & center brackets is then fixed perpendicular to the Strut CC10 with the help of fasteners at every 400mm centersAnutone Slats Surco Plus of size 128x 2440x16mm in then fixed perpendicular to Strut CC18 with suitable edge & centre brackets. Contractor to provide expansion joints of 3mm at every 4.88m length wise and 4.992m width wise. Note:-Wooden packing of appropriate thickness to be provided at rear of strut to bring finish inline with Subtex NRC finish.The system is backlined with Anutone SynthPF 10x10 adhered on wall with dab spots of Anutone stick S7 adhesive., including Anti Termite Treatement.Technical Parameters Product Picture• Fire (Class) – 1 & P • Acoustics – NRC 0.75( For L32 C40 Mounting)• Thermal conductivity (W/mk)– na• Climate (°C, RH) – 50, 70• Light reflectance (%) – 75 (Maple Arce)• Green (VOC, RC %) – E1, 25 |
| 107 | Wood Panel for Walls, Back Fire Panel Spectator and Target Area :- Providing & Fixing Imported PineWood 25 mm thick 4\" width, both side chamfering, Front side machine grinding for smooth surface with water based painting (Apex) on both front and rear sides etc. |
| 108 | Providing & Fixing ofhigh grade, glass fibre reinforced acoustical gypsum wall dado of KNAUF DANOLINE DANOLOFT(3.5x3.5mm square perforation with c/c distance of 8.33mm) in 600x600x12.5mm. Its a concealed sysytem with system D+ giving seamless look with end to end perforation on the tile and screw fixed on Knauf Ceiling perimeter channels 31 x 27x 15 X 0.50mm with the help of nylon sleeves and Knauf Hammer fixing 6X 40 mm and suspending Knauf intermediate channels of 45 x 15 X 0.70 mm from the Knauf L angle and Wedge anchors 6 X 40 mm to be fixed at a distance of 1220mm and with the help of Knauf LN screws 3.5 X11 mm . Knauf Ceiling section 49 X79 X0.50 mm thick with flanges 7 mm each are fixed perpendicular to Knauf intermediate channelusing in line on both horizontal and vertical levels . Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment.The tiles are painted , have Humidity Resistance (RH) of 90%, NRC 0.8 , Light Reflection: 82.6% according to DIN Norm 5036, Fire Performance Class A2-s1,d0 suitable for Green Building application, with Recycled content of 81% and weight 8 kg/m2. • Manufactured from high grade non-combustible glass fibre reinforced gypsum board produced according to EN 520.Including Anti Termite Treatement.Suspension: Concealed screw fixed system with Danoloft Screws• Distance between load-bearing sections c/c 300 mm. Sections width of 60mm.• Distance between hangers and spacers ≤ 900 mm.• Distance from wall to first hanger and spacer ≤ 100 mm.• Location of edge section: Lower edge of edge section = lower edge of finished ceiling.Price is including removal of wall panelling. |
| 109 | Providing & Fixing ofhigh grade, glass fibre reinforced acoustical gypsum ceiling of KNAUF DANOLINE CONTUR UNITY 3(3.5x3.5mm square perforation with c/c distance of 8.33mm) in 600x600x12.5mm. Its a concealed sysytem with system D+ giving seamless look with end to end perforation on the tile & point demountability.The tiles are pre painted with RAL 9003, have Humidity Resistance (RH) of 90%, NRC 0.8 , Light Reflection: 82.6% according to DIN Norm 5036, Fire Performance Class A2-s1,d0 suitable for Green Building application, with Recycled content of 81% and weight 8 kg/m2. • Manufactured from high grade non-combustible glass fibre reinforced gypsum board produced according to EN 520, including Anti Termite Treatement.Suspension: Concealed grid system• Distance between load-bearing sections c/c 600 mm.• Distance between hangers and spacers ≤ 1500 mm.• Distance from wall to first hanger and spacer ≤ 100 mm.• Location of edge section: Lower edge of edge section = lower edge of finished ceiling.Price is including removal of ceiling. |
| 110 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plasteredsurfaces includingscaffoldingifnecessary,preparing the surface bythoroughlycleaningoil,grease,dirtandother foreign matter and sand papering as required etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 111 | Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylicwall putti etc. complete. Spec.No.:- As directed by Engineer in charge. |
| 112 | Supply & Installation of 3.45 mm thick hetrogeneous PVC Vinyl flooring of certified by EN( Europian Standard) 14904, in rolls form of 2m wide and 23m long, total weight 3295 g/m2, Shock Absorption as per EN 14808 - 6%, Friction as per EN 13036-4 - 80 to 110, Vertical deformation as per EN 14809 - 0.4mm, Vertical Ball Behaviour as per EN 12235 - 98%, 100% recyclable, VOC emission after 28days lower than ≤10μg/m3, Phthalate Free. The laid flooring shall comply the fire rating CFL S1 as per EN 13501-The joints should be thermo welded with matching welding rods provided by the manufacturer. After welding the flooring will be seamless.The sub-surface should be absolutely at one level (Zero) for installing vinyl flooring. |
| 113 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical MeansSpec. No.:- Bd.A.1 Page One Number 259 |
| 114 | ProvidingpreconstructionalantitermitetreatmentasperI.S.6313(Part-II)bytreatingthe bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percentofchlorophyrifospersquaremeterofsurfaceareacovering10yearsguaranteeon bond paper.Spec. No.:- As directed by Engineer in charge. |
| 115 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surfaceofplinthfillingattherateof5litresofemulsionconcentrateat1.0percentof clorophyrifosperOne Square Metre of surface area covering ten years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 116 | Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cmthick including hand packing and compacting etc. complete.Spec. No.:- Bd.A. 12 PageOne Number 264 |
| 117 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.Spec. No.:- As director by engineer in charge and BDG-2 and 5 |
| 118 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade)Spec. No.:- Bd. E. 1 Page One Number 287 |
| 119 | Supplying soft murum at the road site, including conveying and stacking complete. |
| 120 | Spreading hard murum/ soft murrum/ gravel or kankar for side width complete |
| 121 | Providing and Fixing in Position UV stabilised 2 mm thick corrugated Polycarbonate sheet including removing and stacking of existing sheets as directed by Engineer incharge. |
| 122 | Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceableandunserviceablematerials,stackingthesameasandwheredirectedinthe compound including scaffolding etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 123 | Electrical Work of 25m Meter Range building:-Supplying & laying HMS PVC conduit 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 124 | Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 125 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG MA/BW |
| 126 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 127 | Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit/ casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW |
| 128 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 129 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 130 | Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light with polycarbonate body, heat sink, integrated HF electronic driver complete & compatible to T8 / T12 LED luminaire by disconnecting starter & ballast if necessary. |
| 131 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 132 | Sports Lighting SITC ofRecessed monted 2\"x2\", 36W Recessed 2\"X2\"LED ceiling fixture with system outut≥4200lm. System efficacy is ≥120lm/W.product is with IP20 CRCA powder coated housing. Luminaire shall have satin finished translucence (HET) PC diffuser for Uniform illumination and wider light distribution.LM 80-08 compliant LEDs from reputed makes such as APT Electronics / Cree, / Bridgelux / Lumiled should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current. Proposed CCT s 6500K with CRI>80 & SDCM<5. Driver shuld be DALI comptible.Driver is having efficiency of minimum 85%. p.f. ≥0.95 & THD≤10%.Driver should have 4KV inbuit surge protection is given. Driver should be able to operate at 140 V to 240 V AC supply. |
| 133 | Sports LightingSITC ofIP65Syemmetric medium beam, 100W LED Floodlight luminaire with system efficacy of 110lm/W.system output should not be more than 11000lm for 100W. Power consumption of luminaire should not exceed 100W. CCT should be 5700K with CRI≥ 70. The housing should be made of non-corrosive high-pressure die-cast aluminum to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate.. The Luminaire should have a 4KVSPD duly bolted in the Luminaire .The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be with 0-10V dimable diver. Driver should have short circuit and open circuit protection. Luminaire and Driver both should be BIS approved andCRS no ( individual R no ) should be shared along with LM79 & LM80 during bid submission. Product should have Lifeclass of 50K hours @L70 with PF > 0.95 & THD ≤ 10%..product is designed to operate at (-10) Deg to45deg operating temp. 50,000 Hrs burning life is provided as per L70B50. |
| 134 | Sports LightingSITC of 35W , Suspended / pendent mounted LED 1130mm Linar LED light. System output should not be more than 4000lm .System efficacy is 120lm/W. width of the product should be 50mm. Housing should be of CRCA powder coatedwith high Translucent Polystyrine Diffuser. Proposed CCT is 6500K along with CRI≥80.LM 80-08 compliant LEDs from reputed makes such asAPT Electronics / Cree, / Bridgelux / Lumiled should be provided. Product should have IP20 protection.LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided.Driver shuld be DALI comptible.Driver is having p.f. ≥0.95 with iTHD≤10% Efficiency of driver shuld be minimum 90% with 4KV internal surge protection. Product is suitable to operate in 140 - 270V Ac range. Product should have inbuilt 4KV surge protection.. service life is 5000K as per L70B50. |
| 135 | SITC of Smart Panel with 63Amp 3 phase incomer and 2 outgoings of 32A 3Phase. Panel should have digital energy meter, control unit for monitoring and control, battery for control unit, SPD for control unit, CT, PT and current leak coil. Control unit should be compatible with 3phase and single phase power supply. It should be compatible for exchange of data through CAT6 cable or data sim card. |
| 136 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 137 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 138 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 139 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 140 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 141 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 142 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 143 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 144 | Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 145 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 146 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 147 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 148 | Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WGPW/ SW. |
| 149 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 150 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 151 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 152 | Supplying, erecting & marking SPMCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 153 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 154 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 155 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 156 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 157 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 158 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron /GI frame as per specification no. SW-SWR/MCBDB |
| 159 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 160 | Supplying and erecting electronic type step regulator for ceiling fan 600 / 900 / 1200/ 1400 mm. sweep, complete erected on provided switch board. |
| 161 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 162 | Providing & erecting hot dipped galvanised Perforatedtype cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 163 | Providing & erecting hot dipped galvanised Perforated type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 164 | Supplying and erecting PVC box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX. |
| 165 | Supplying and erecting PVC box trunking of size 75x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX. |
| 166 | Supplying and erecting PVC box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX. |
| 167 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 168 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 169 | Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 170 | Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 171 | Supplying, erecting & marking DPMCB 40A to 63A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 172 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 173 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 174 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 10A, 2 pin plug & earth socket and 10A, 3 pin plug top with 10A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame. |
| 175 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame. |
| 176 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 30 A, 3 pin plug & earth socket and 30A, 3 pin plug top with 30A triple pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame. |
| 177 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With PVC accessories on wall / ceiling as per specification No: WG-MA/CON. |
| 178 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 179 | Supplying and erecting electronic type step regulator for ceiling fan 600 /900 / 1200/ 1400 mm. sweep, complete erected on provided switch board. |
| 180 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 Kv |
| 181 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 182 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 183 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 184 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 185 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 186 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 187 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 188 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 189 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU8) For use of FRLS-XLPE insulation instead of FR-XLPE insulatedarmoured cable increase rates by 5 % |
| 190 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 191 | Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 192 | Supplying and erecting terminal spreaders suitable for 3 pole, up to 250A MCCB (set of 6) |
| 193 | Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave with backup time of 0.30 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 1 phase output complete with all protections as per specification no. AP-UPS |
| 194 | DATA networkingSupplying and installing cat-6 LSZH cable suitable for networking as peR specification no. WG-COC/NC |
| 195 | Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 196 | Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 197 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 198 | Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. |
| 199 | Supplying and fixing tool-less shutter keystone jack (RJ-45) in provided patch panel complete as per specification no. WG-NAS/KJ |
| 200 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 201 | Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-D in position as per specification No. WG-COC/PC |
| 202 | Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 203 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 204 | VOICE networkingSupplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 205 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 206 | Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 207 | Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 208 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW |
| 209 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW |
| 210 | Supplying and erecting modular type T.V. socket single outlet, duly erected onprovided plate and box with wiring connections complete. |
| 211 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 212 | FIRE ALARM SYSTEM EQUIPMENTSupplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300μA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/ SD. |
| 213 | Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI |
| 214 | Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area\"s etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD. |
| 215 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \"Break Glass\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. |
| 216 | Supplying, installing, testing and commissioning of addressable fire control/ relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM. |
| 217 | Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM. |
| 218 | Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM. |
| 219 | Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. |
| 220 | Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. |
| 221 | Supplying, installation, testing & commissioning of fire fighter phone. jack complete as required. |
| 222 | Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU |
| 223 | Voice Evacuation System (Public Address System)Supply, Installation, testing & Commissioning of 6W Ceiling Recessed Speaker with max SPL @1M/1W 88dB . Frequency response of 125Hz-16KHz. The speaker must have a metal grill & tappings at 6W/3W/1.5W. White color speaker with good aesthetics. |
| 224 | Supply, Installation, testing & Commissioning of 6W Ceiling Surface Speaker (Ceiling Speaker + Back Box) with max SPL @1M/1W 88dB . Frequency response of 125Hz-16KHz. The speaker must have a metal grill & tappings at 6W/3W/1.5W. White color speaker with good aesthetics. |
| 225 | Supply, Installation, testing & Commissioning of 6W Wall Mount Speaker with max SPL @1M/1W 90dB . Frequency response of 200Hz-16KHz. The speaker must have a high impact ABS cabinet & tappings at 6W/3W. White color speaker with good aesthetics. |
| 226 | Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU |
| 227 | S u p p l y i n g& erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wallcomplete. |
| 228 | SITC of 12 Channel Multi-Protocol Dimmer Controller which can support for 0-10V/DALI Broadcast/DSI drivers with Instant visual feedback on channel status for all 12 channels.Device should be capable of connecting 80 DALI drivers per Channel (Total 300 No\"s per device), 100 DSI drivers per Channel (total 375 No\"s Per device) & for 0-10V 50 mA source current & 50mA of sink current Approx. 22 Drivers per channel.Device should have override option on the control itself.Supply Voltage: 100-240AC, system Output DC current 200mA which can support 10 button panels without any additional power supply. Device should also have dry contact Aux input |
| 229 | SITC ofAntumbra Display keypad with Central Display to present multiple pages of functions & system Information User Interface white with white Rim for different zones etc with Fully programmable optionsfor Indivuidual control/ group control/ Scene control/ Tasks etc. Wall mountedon 2M (3.5\"\" X 3.5\"\" size) modularbox. Front cover with Backlight, built in proximity sensor and Loadedicons like presentation scenario, meeting scenario, masterOn/ Off, Powersaving mode etc along with a LED indicator for each operations. Central LCD — Allows for system information to be shown such as temperature, time, channel level and current scene. Button function can change when navigating between the up to 16 pages.Operating on 12V DC @ 35-60mAfrom network.Compliance certifcation : E, RCM, FCC, ICES, EN50491-3, UKCA, RoHSEquivalent to Philips Dynalite item Code: PADPE-WW-X + DACM-DYNET (LSP6) |
| 230 | SITC ofNetwork Power Supply. Power: 15V DC 1.5 Amps regulatedpower supply, designedto supplement the networkDC supply. Supply of 110-240V±14% 50/60Hz . The switchmode design allows the device to be used with a wide range of supply voltageswithout the need for a manual selectorsetting. Size of six-unit DIN-railmount enclosurethat has a circuit breakerprofile. This enablesthe device to be installedin all types of electricalequipment enclosures, includingthose with cover aperturesspecifically designedfor circuit breakers.Certifications: CE, RCM, UKCA, RoHSSimilar to Philips Dynalite DDNP1501 |
| 231 | SITC ofNetworkGatewayto provide integration betweenthe control systemsand Ethernet networks.It is designedto provideremote control of sites and link multiplesites together,using the Internetor a corporate LAN as a backbone. The device supportsthe TCP/IP protocol,with static or DHCP assignedIP addressing. An integralwebserver allows Browserbased control scenarios and full control with iOS/Android Mobile and Tab devices. The interfaceincorporates a Programmable Logic Controller that can processcomprehensive conditional and sequential logic and arithmetic functions and time based events and schedulings. Power: 12-24V DC suppliedby the control system network at 200mA.Certification: CE, RCM, UL/cUL, FCC, ICES, UKCA, RoHSSimilar to Philips Dynalite PDEG |
| 232 | Open To Sky Area Development-50 meter Range Building:-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingthe excavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingas directed,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 3.00 m.) By Manual MeansSpec. No.:- Bd.A.1 Page Number 259 |
| 233 | Dismantling brick masonry in lime orcement mortar and stackingthematerils as directedwithallleads, lifts etc.Spec. No.:- As directed by Engineer in charge. |
| 234 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surfaceofplinthfillingattherateof5litresofemulsionconcentrateat1.0percentof clorophyrifosperOne Square Metre of surface area covering ten years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 235 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineerincharge inlayersof15cm to20cmincludingwateringandcompactionetc. complete.Spec. No.:- Bd.A.11 Page One Number 263 |
| 236 | Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete.Spec. No.:- 0 |
| 237 | Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cmthick including hand packing and compacting etc. complete.Spec. No.:- Bd.A. 12 PageOne Number 264 |
| 238 | Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding , Without SCADA |
| 239 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade)Spec. No.:- Bd. E. 1 Page One Number 287 |
| 240 | Providing and fixing Ductile iron man hole cover of light / medium / heavy duty with frame of any size over inspection chamber etc.complete |
| 241 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns,canopies,staircase,newels, chajjas,lintelspardis,copings,fins,archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Spec. No.:- Bd.F.17, Page One Number 306 |
| 242 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.Spec. No.:- As director by engineer in charge and BDG-2 and 5 |
| 243 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. CompleteSpec. No.:- Bd.G.5 Page One Number 315 |
| 244 | Providingsandfacedplasterexternallyincementmortarusingapprovedscreenedsand,inallpositions including base coat of 15 mm thick in cement mortar 1:4 using waterproofingcompoundat 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoat roughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurface bytakingoutgrainsandcuringforfourteendays scaffolding etc.complete.Spec. No.:- Bd.L.7 Page Number 369 |
| 245 | Providing waterproof plaster in W.C. and bath12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete.(Excluding Tiles) (As directed by Engineer in Charge)Spec. No.:- As directed by Engineer in charge. |
| 246 | Providingand applyingtwocoatsof exterioracraylicemulsion paintconfirmingto corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces includingcleaning,preparingtheplastersurface,applyingprimercoat,scaffoldingif necessary , and watering the surface for two days etc complete.Spec. No.:- As directed by Engineer in charge. |
| 247 | Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.Spec. No.:- Bd.V.41, Page One Number 573 |
| 248 | ProvidingandconstructingBrickMasonryInspectionChamber60cmx45cmx90cm including1:4:8cementconcretefoundation1:2:4cementconcretechannelshalfround G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.Spec. No.:- Bd.V.43, Page One Number 574 |
| 249 | ProvidingandconstructingBrickMasonryInspectionChamber90cmx45cmx90cm including1:4:8cementconcretefoundation1:2:4cementconcretechannelshalfround G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.Spec. No.:- Bd.V.43, Page One Number 574 |
| 250 | Providing & Fixing 50 mm ArtificialGrass, thick rubber underside, green grass with yellow strands give realistic look and feel.Spec. No.:- As directed by Engineer in charge. |
| 251 | Interior Work & Acoustical refurbishment of 50 meter Range Building:-Removing cement tiles, or marble or polishedshahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. completeSpec. No.:- As directed by Engineer in charge. |
| 252 | Removing teak wood trellies work with frame including stacking the materials as directed with all leads, lifts etc. complete. |
| 253 | Removingdoorsandwindowswithframesandstackingthematerialsasdirectedwithall leads, lifts etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 254 | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc.complete.Spec. No.:- As directed by Engineer in charge. |
| 255 | Providing antitermite treatment to the wooden frames of doors/windows of the existing building as perI.S.6313(Part-III) bydrilling 6mm dia.holes at four corners on one side and four corners on other side at a down wardangle of about 45 degree at the junction of wood work and masonary and injecting 150ml.of chlorodane 5% W.C.and sealing by filling putty etc. complete covering 2 years guarantee on bond paper. |
| 256 | ProvidingantitermitetreatmenttothesidesofflooringoftheexistingbuildingasperI.S. 6313 (Part-III) by punching holes 6mm dia. drilled at a distance of 30cm. centre to centre and injecting one percentof chlorodane emulsionconcentrate at the rate of50 mlper hole and sealing by filling putty etc. complete covering 2 years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 257 | Providingantitermitetreatmenttothefor interior surfaces of floor, wall.Scope of Work•Making 3” wide x 9”deep trench along the wall & floor OR Drilling 12 mm diameter holes at the junction of Wall & Floor at 90° angle•Drilling 12 mm diameter holes, 12 inches deep at 1 feet distance C/C•Filling the holes with Termiticide Solution (1lit per hole) OR Applying Termiticide Solution @ 2.25 liter per linear meter in trenches•Filling the holes with cement mortar OR Filling the trenches with soil and treat the top surface with Termiticide Solution @ 1.0 ltr. Per linear meter•Customer is requested to put plinth protectioncomplete covering 2 years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 258 | Transportation of excavated & debris from site to disposing site (lead 3km) |
| 259 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.2 Page Number 368 |
| 260 | Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring. Spec. No.:- BDM 33.28, Page Number 158 |
| 261 | Providing & Fixing in position Acoustical Doors along with 150x150mm teak wood frame, doors made from 50mm Teak wood frame 600x600ctoc filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides,12mm waterproof ply & veneer from both sides, including 150mm heavy duty SShinges(Geze/Dormaoreq.)4no each leaf,withDoor-closer(Dorma/Gezeoreq.)including cost of required Cut-Outs,decorative mouldings/finishing-items/melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete |
| 262 | Supply & installation of Anutone Salon Slats Surco made of pinewood E1 grade fiberboard, melamine/veneer laminated finish, groove perforated slats L16-2 - (2mm grooves @16mm pitch with 27% open area) / L32-2 - (2mm grooves @ 32mm centers with 15% open area) surface density 63g/m2,tongue-groove edge for a seamless look, 5-test fire retardant grade, size 128 x2440x16mm, volume density of base board 700Kg/m3, weight 9Kg/m2 (L16), 10.5Kg/m2 (L32), 11Kg/m2 (L64) installed by using Anutone Strut framework system.The Anutone Strut framework system shall include Anutone Strut CC10 thickness 0.55mm, length 3600mm, knurled web 40mm, depth 10mm and equal flanges 15mm is fastened to the wall positioned vertically at every 600mm centres.Anutone Strut CC18,aluminium core cross channel, thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge & center brackets is then fixed perpendicular to the Strut CC10 with the help of fasteners at every 400mm centersAnutone Slats Surco Plus of size 128x 2440x16mm in then fixed perpendicular to Strut CC18 with suitable edge & centre brackets. Contractor to provide expansion joints of 3mm at every 4.88m length wise and 4.992m width wise. Note:-Wooden packing of appropriate thickness to be provided at rear of strut to bring finish inline with Subtex NRC finish.The system is backlined with Anutone SynthPF 10x10 adhered on wall with dab spots of Anutone stick S7 adhesive., including Anti Termite Treatement.Technical Parameters Product Picture• Fire (Class) – 1 & P • Acoustics – NRC 0.75( For L32 C40 Mounting)• Thermal conductivity (W/mk)– na• Climate (°C, RH) – 50, 70• Light reflectance (%) – 75 (Maple Arce)• Green (VOC, RC %) – E1, 25 |
| 263 | Wood Panel for Walls, Back Fire Panel Spectator and Target Area Providing & Fixing Imported PineWood 25 mm thick 4\" width, both side chamfering, Front side machine grinding for smooth surface with water based painting (Apex) on both front and rear sides etc. |
| 264 | Providing & Fixing ofhigh grade, glass fibre reinforced acoustical gypsum wall dado of KNAUF DANOLINE DANOLOFT(3.5x3.5mm square perforation with c/c distance of 8.33mm) in 600x600x12.5mm. Its a concealed sysytem with system D+ giving seamless look with end to end perforation on the tile and screw fixed on Knauf Ceiling perimeter channels 31 x 27x 15 X 0.50mm with the help of nylon sleeves and Knauf Hammer fixing 6X 40 mm and suspending Knauf intermediate channels of 45 x 15 X 0.70 mm from the Knauf L angle and Wedge anchors 6 X 40 mm to be fixed at a distance of 1220mm and with the help of Knauf LN screws 3.5 X11 mm . Knauf Ceiling section 49 X79 X0.50 mm thick with flanges 7 mm each are fixed perpendicular to Knauf intermediate channelusing in line on both horizontal and vertical levels . Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment.The tiles are painted , have Humidity Resistance (RH) of 90%, NRC 0.8 , Light Reflection: 82.6% according to DIN Norm 5036, Fire Performance Class A2-s1,d0 suitable for Green Building application, with Recycled content of 81% and weight 8 kg/m2. • Manufactured from high grade non-combustible glass fibre reinforced gypsum board produced according to EN 520.Including Anti Termite Treatement.Suspension: Concealed screw fixed system with Danoloft Screws• Distance between load-bearing sections c/c 300 mm. Sections width of 60mm.• Distance between hangers and spacers ≤ 900 mm.• Distance from wall to first hanger and spacer ≤ 100 mm.• Location of edge section: Lower edge of edge section = lower edge of finished ceiling.Price is including removal of wall panelling. |
| 265 | Providing & Fixing ofhigh grade, glass fibre reinforced acoustical gypsum ceiling of KNAUF DANOLINE CONTUR UNITY 3(3.5x3.5mm square perforation with c/c distance of 8.33mm) in 600x600x12.5mm. Its a concealed sysytem with system D+ giving seamless look with end to end perforation on the tile & point demountability.The tiles are pre painted with RAL 9003, have Humidity Resistance (RH) of 90%, NRC 0.8 , Light Reflection: 82.6% according to DIN Norm 5036, Fire Performance Class A2-s1,d0 suitable for Green Building application, with Recycled content of 81% and weight 8 kg/m2. • Manufactured from high grade non-combustible glass fibre reinforced gypsum board produced according to EN 520, including Anti Termite Treatement.Suspension: Concealed grid system• Distance between load-bearing sections c/c 600 mm.• Distance between hangers and spacers ≤ 1500 mm.• Distance from wall to first hanger and spacer ≤ 100 mm.• Location of edge section: Lower edge of edge section = lower edge of finished ceiling.Price is including removal of ceiling. |
| 266 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plasteredsurfaces includingscaffoldingifnecessary,preparing the surface bythoroughlycleaningoil,grease,dirtandother foreign matter and sand papering as required etc. complete. |
| 267 | Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylicwall putti etc. complete. Spec.No.:- As directed by Engineer in charge. |
| 268 | Supply & Installation of 3.45 mm thick hetrogeneous PVC Vinyl flooring of certified by EN( Europian Standard) 14904, in rolls form of 2m wide and 23m long, total weight 3295 g/m2, Shock Absorption as per EN 14808 - 6%, Friction as per EN 13036-4 - 80 to 110, Vertical deformation as per EN 14809 - 0.4mm, Vertical Ball Behaviour as per EN 12235 - 98%, 100% recyclable, VOC emission after 28days lower than ≤10μg/m3, Phthalate Free. The laid flooring shall comply the fire rating CFL S1 as per EN 13501-The joints should be thermo welded with matching welding rods provided by the manufacturer. After welding the flooring will be seamless.The sub-surface should be absolutely at one level (Zero) for installing vinyl flooring. |
| 269 | Supplying & laying HMS PVC conduit 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 270 | Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 271 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG MA/BW |
| 272 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 273 | Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit/ casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modulartype switch, earthing and required accessories as per specification No: WGPW/HW |
| 274 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 275 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 276 | Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light withpolycarbonate body, heat sink, integrated HF electronic driver complete &compatible to T8 / T12 LED luminaire by disconnecting starter & ballast ifnecessary. |
| 277 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 278 | Sports Lighting SITC ofRecessed monted 2\"x2\", 36W Recessed 2\"X2\"LED ceiling fixture with system outut≥4200lm. System efficacy is ≥120lm/W.product is with IP20 CRCA powder coated housing. Luminaire shall have satin finished translucence (HET) PC diffuser for Uniform illumination and wider light distribution.LM 80-08 compliant LEDs from reputed makes such as APT Electronics / Cree, / Bridgelux / Lumiled should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current. Proposed CCT s 6500K with CRI>80 & SDCM<5. Driver shuld be DALI comptible.Driver is having efficiency of minimum 85%. p.f. ≥0.95 & THD≤10%.Driver should have 4KV inbuit surge protection is given. Driver should be able to operate at 140 V to 240 V AC supply. |
| 279 | Sports LightingSITC ofIP65Syemmetric medium beam, 100W LED Floodlight luminaire with system efficacy of 110lm/W.system output should not be more than 11000lm for 100W. Power consumption of luminaire should not exceed 100W. CCT should be 5700K with CRI≥ 70. The housing should be made of non-corrosive high-pressure die-cast aluminum to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate.. The Luminaire should have a 4KVSPD duly bolted in the Luminaire .The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be with 0-10V dimable diver. Driver should have short circuit and open circuit protection. Luminaire and Driver both should be BIS approved andCRS no ( individual R no ) should be shared along with LM79 & LM80 during bid submission. Product should have Lifeclass of 50K hours @L70 with PF > 0.95 & THD ≤ 10%..product is designed to operate at (-10) Deg to45deg operating temp. 50,000 Hrs burning life is provided as per L70B50. |
| 280 | Sports LightingSITC of 35W , Suspended / pendent mounted LED 1130mm Linar LED light. System output should not be more than 4000lm .System efficacy is 120lm/W. width of the product should be 50mm. Housing should be of CRCA powder coatedwith high Translucent Polystyrine Diffuser. Proposed CCT is 6500K along with CRI≥80.LM 80-08 compliant LEDs from reputed makes such asAPT Electronics / Cree, / Bridgelux / Lumiled should be provided. Product should have IP20 protection.LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided.Driver shuld be DALI comptible.Driver is having p.f. ≥0.95 with iTHD≤10% Efficiency of driver shuld be minimum 90% with 4KV internal surge protection. Product is suitable to operate in 140 - 270V Ac range. Product should have inbuilt 4KV surge protection.. service life is 5000K as per L70B50. |
| 281 | SITC of Smart Panel with 63Amp 3 phase incomer and 2 outgoings of 32A 3Phase. Panel should have digital energy meter, control unit for monitoring and control, battery for control unit, SPD for control unit, CT, PT and current leak coil. Control unit should be compatible with 3phase and single phase power supply. It should be compatible for exchange of data through CAT6 cable or data sim card. |
| 282 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 283 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 284 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 285 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 286 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 287 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 288 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 289 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 290 | Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 291 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 292 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 293 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 294 | Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WGPW/ SW. |
| 295 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 296 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 297 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 298 | Supplying, erecting & marking SPMCB 40A to 63A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 299 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 300 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 301 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 302 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 303 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 304 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron /GI frame as per specification no. SW-SWR/MCBDB |
| 305 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 306 | Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/1200/ 1400 mm. sweep, complete erected on provided switch board. |
| 307 | Providing & erecting hot dipped galvanised Perforatedtype cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 308 | Providing & erecting hot dipped galvanised Perforated type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 309 | Supplying and erecting PVC box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX. |
| 310 | Supplying and erecting PVC box trunking of size 75x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX. |
| 311 | Supplying and erecting PVC box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX. |
| 312 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic typewith 30/100/300 mA sensitivity with earth leakage trip indication complete asper specification no. SW-RCCB/RCCB |
| 313 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic typewith 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 314 | Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic typewith 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 315 | Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 316 | Supplying, erecting & marking DPMCB 40A to 63A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 317 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 318 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 319 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 10A, 2 pin plug & earth socket and 10A, 3 pin plug top with 10A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame. |
| 320 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame. |
| 321 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 30 A, 3 pin plug & earth socket and 30A, 3 pin plug top with 30A triple pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame. |
| 322 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With PVC accessories on wall / ceiling as per specification No: WG-MA/CON. |
| 323 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 324 | Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/1200/ 1400 mm. sweep, complete erected on provided switch board. |
| 325 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltagegrade up to 1.1 Kv |
| 326 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 327 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 328 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 329 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 330 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 331 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 332 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 333 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 334 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU8) For use of FRLS-XLPE insulation instead of FR-XLPE insulatedarmoured cable increase rates by 5 % |
| 335 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 336 | Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 337 | Supplying and erecting terminal spreaders suitable for 3 pole, up to 250A MCCB (set of 6) |
| 338 | DATA networkingSupplying and installing cat-6 LSZH cable suitable for networking as peR specification no. WG-COC/NC |
| 339 | Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 340 | Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 341 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 342 | Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. |
| 343 | Supplying and fixing tool-less shutter keystone jack (RJ-45) in provided patch panel complete as per specification no. WG-NAS/KJ |
| 344 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 345 | Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-D in position as per specification No. WG-COC/PC |
| 346 | Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 347 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 348 | VOICE networkingSupplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 349 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 350 | Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 351 | Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 352 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW |
| 353 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW |
| 354 | Supplying and erecting modular type T.V. socket single outlet, duly erected onprovided plate and box with wiring connections complete. |
| 355 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 356 | S u p p l y i n g& erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wallcomplete. |
| 357 | SITC of 12 Channel Multi-Protocol Dimmer Controller which can support for 0-10V/DALI Broadcast/DSI drivers with Instant visual feedback on channel status for all 12 channels.Device should be capable of connecting 80 DALI drivers per Channel (Total 300 No\"s per device), 100 DSI drivers per Channel (total 375 No\"s Per device) & for 0-10V 50 mA source current & 50mA of sink current Approx. 22 Drivers per channel.Device should have override option on the control itself.Supply Voltage: 100-240AC, system Output DC current 200mA which can support 10 button panels without any additional power supply. Device should also have dry contact Aux input |
| 358 | SITC ofAntumbra Display keypad with Central Display to present multiple pages of functions & system Information User Interface white with white Rim for different zones etc with Fully programmable optionsfor Indivuidual control/ group control/ Scene control/ Tasks etc. Wall mountedon 2M (3.5\"\" X 3.5\"\" size) modularbox. Front cover with Backlight, built in proximity sensor and Loadedicons like presentation scenario, meeting scenario, masterOn/ Off, Powersaving mode etc along with a LED indicator for each operations. Central LCD — Allows for system information to be shown such as temperature, time, channel level and current scene. Button function can change when navigating between the up to 16 pages.Operating on 12V DC @ 35-60mAfrom network.Compliance certifcation : E, RCM, FCC, ICES, EN50491-3, UKCA, RoHSEquivalent to Philips Dynalite item Code: PADPE-WW-X + DACM-DYNET (LSP6) |
| 359 | SITC ofNetwork Power Supply. Power: 15V DC 1.5 Amps regulatedpower supply, designedto supplement the networkDC supply. Supply of 110-240V±14% 50/60Hz . The switchmode design allows the device to be used with a wide range of supply voltageswithout the need for a manual selectorsetting. Size of six-unit DIN-railmount enclosurethat has a circuit breakerprofile. This enablesthe device to be installedin all types of electricalequipment enclosures, includingthose with cover aperturesspecifically designedfor circuit breakers.Certifications: CE, RCM, UKCA, RoHSSimilar to Philips Dynalite DDNP1501 |
| 360 | SITC ofNetworkGatewayto provide integration betweenthe control systemsand Ethernet networks.It is designedto provideremote control of sites and link multiplesites together,using the Internetor a corporate LAN as a backbone. The device supportsthe TCP/IP protocol,with static or DHCP assignedIP addressing. An integralwebserver allows Browserbased control scenarios and full control with iOS/Android Mobile and Tab devices. The interfaceincorporates a Programmable Logic Controller that can processcomprehensive conditional and sequential logic and arithmetic functions and time based events and schedulings. Power: 12-24V DC suppliedby the control system network at 200mA.Certification: CE, RCM, UL/cUL, FCC, ICES, UKCA, RoHSSimilar to Philips Dynalite PDEG |
| 361 | Open To Sky Area Development-Final Range Building:-Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingthe excavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingas directed,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 3.00 m.) By Manual MeansSpec. No.:- Bd.A.1 Page Number 259 |
| 362 | Dismantling brick masonry in lime orcement mortar and stackingthematerils as directedwithallleads, lifts etc.Spec. No.:- As directed by Engineer in charge. |
| 363 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surfaceofplinthfillingattherateof5litresofemulsionconcentrateat1.0percentof clorophyrifosperOne Square Metre of surface area covering ten years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 364 | Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineerincharge inlayersof15cm to20cmincludingwateringandcompactionetc. complete.Spec. No.:- Bd.A.11 Page One Number 263 |
| 365 | Compacting the hard murum side widths including laying in layers on each side with vibratory roller including artificial watering etc. complete.Spec. No.:- 0 |
| 366 | Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cmthick including hand packing and compacting etc. complete.Spec. No.:- Bd.A. 12 PageOne Number 264 |
| 367 | Providing and laying Cast in situ/Ready Mixcement concrete in M15 of trap/ granite/quartzite/gneiss metal for foundation and bedding , Without SCADA |
| 368 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade)Spec. No.:- Bd. E. 1 Page One Number 287 |
| 369 | Providing and fixing Ductile iron man hole cover of light / medium / heavy duty with frame of any size over inspection chamber etc.complete |
| 370 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C.pilecaps,footings,foundations,slabs,beamscolumns,canopies,staircase,newels, chajjas,lintelspardis,copings,fins,archesetc.asperdetaileddesigns,drawingsand schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete.Spec. No.:- Bd.F.17, Page One Number 306 |
| 371 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.Spec. No.:- As director by engineer in charge and BDG-2 and 5 |
| 372 | Providing secondclassBurntBrickmasonrywithconventional/I.S.typebricksincement mortar1:6insuperstructureincludingstrikingjoints,rakingoutjoints,wateringand scaffolding etc. CompleteSpec. No.:- Bd.G.5 Page One Number 315 |
| 373 | Providingsandfacedplasterexternallyincementmortarusingapprovedscreenedsand,inallpositions including base coat of 15 mm thick in cement mortar 1:4 using waterproofingcompoundat 1Kilogramper cement bag curing the same for not less than 2 days and keeping thesurfaceofthebasecoat roughtoreceivethesandfacedtreatment6to8mm thickin cementmortar1:4finishingthesurface bytakingoutgrainsandcuringforfourteendays scaffolding etc.complete.Spec. No.:- Bd.L.7 Page Number 369 |
| 374 | Providing waterproof plaster in W.C. and bath12 mm thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 Kilogram. per bag of cement of approved make and manufacturer and curing etc. complete.(Excluding Tiles) (As directed by Engineer in Charge)Spec. No.:- As directed by Engineer in charge. |
| 375 | Providingand applyingtwocoatsof exterioracraylicemulsion paintconfirmingto corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces includingcleaning,preparingtheplastersurface,applyingprimercoat,scaffoldingif necessary , and watering the surface for two days etc complete.Spec. No.:- As directed by Engineer in charge. |
| 376 | Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.Spec. No.:- Bd.V.41, Page One Number 573 |
| 377 | ProvidingandconstructingBrickMasonryInspectionChamber60cmx45cmx90cm including1:4:8cementconcretefoundation1:2:4cementconcretechannelshalfround G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.Spec. No.:- Bd.V.43, Page One Number 574 |
| 378 | ProvidingandconstructingBrickMasonryInspectionChamber90cmx45cmx90cm including1:4:8cementconcretefoundation1:2:4cementconcretechannelshalfround G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete.Spec. No.:- Bd.V.43, Page One Number 574 |
| 379 | Providing & Fixing 50 mm ArtificialGrass, thick rubber underside, green grass with yellow strands give realistic look and feel.Spec. No.:- As directed by Engineer in charge. |
| 380 | Interior Work & Acoustical refurbishment of Final Range Building:-Removing cement tiles, or marble or polishedshahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. completeSpec. No.:- As directed by Engineer in charge. |
| 381 | Removing teak wood trellies work with frame including stacking the materials as directed with all leads, lifts etc. complete. |
| 382 | Removingdoorsandwindowswithframesandstackingthematerialsasdirectedwithall leads, lifts etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 383 | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc.complete.Spec. No.:- As directed by Engineer in charge. |
| 384 | Providing antitermite treatment to the wooden frames of doors/windows of the existing building as perI.S.6313(Part-III) bydrilling 6mm dia.holes at four corners on one side and four corners on other side at a down wardangle of about 45 degree at the junction of wood work and masonary and injecting 150ml.of chlorodane 5% W.C.and sealing by filling putty etc. complete covering 2 years guarantee on bond paper. |
| 385 | ProvidingantitermitetreatmenttothesidesofflooringoftheexistingbuildingasperI.S. 6313 (Part-III) by punching holes 6mm dia. drilled at a distance of 30cm. centre to centre and injecting one percentof chlorodane emulsionconcentrate at the rate of50 mlper hole and sealing by filling putty etc. complete covering 2 years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 386 | Providingantitermitetreatmenttothefor interior surfaces of floor, wall.Scope of Work•Making 3” wide x 9”deep trench along the wall & floor ORDrilling 12 mm diameter holes at the junction of Wall & Floor at 90° angle•Drilling 12 mm diameter holes, 12 inches deep at 1 feet distance C/C•Filling the holes with Termiticide Solution (1lit per hole) ORApplying Termiticide Solution @ 2.25 liter per linear meter in trenches•Filling the holes with cement mortar ORFilling the trenches with soil and treat the top surface with TermiticideSolution @ 1.0 ltr. Per linear meter•Customer is requested to put plinth protectioncomplete covering 2 years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 387 | Transportation of excavated & debris from site to disposing site (lead 3km) |
| 388 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.2 Page Number 368 |
| 389 | Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring. Spec. No.:- BDM 33.28, Page Number 158 |
| 390 | Providing & Fixing in position Acoustical Doors along with 150x150mm teak wood frame, doors made from 50mm Teak wood frame 600x600ctoc filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides,12mm waterproof ply & veneer from both sides, including 150mm heavy duty SShinges(Geze/Dormaoreq.)4no each leaf,withDoor-closer(Dorma/Gezeoreq.)including cost of required Cut-Outs,decorative mouldings/finishing-items/melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete |
| 391 | Supply & installation of Anutone Salon Slats Surco made of pinewood E1 grade fiberboard, melamine/veneer laminated finish, groove perforated slats L16-2 - (2mm grooves @16mm pitch with 27% open area) / L32-2 - (2mm grooves @ 32mm centers with 15% open area) surface density 63g/m2,tongue-groove edge for a seamless look, 5-test fire retardant grade, size 128 x2440x16mm, volume density of base board 700Kg/m3, weight 9Kg/m2 (L16), 10.5Kg/m2 (L32), 11Kg/m2 (L64) installed by using Anutone Strut framework system.The Anutone Strut framework system shall include Anutone Strut CC10 thickness 0.55mm, length 3600mm, knurled web 40mm, depth 10mm and equal flanges 15mm is fastened to the wall positioned vertically at every 600mm centres.Anutone Strut CC18,aluminium core cross channel, thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge & center brackets is then fixed perpendicular to the Strut CC10 with the help of fasteners at every 400mm centersAnutone Slats Surco Plus of size 128x 2440x16mm in then fixed perpendicular to Strut CC18 with suitable edge & centre brackets. Contractor to provide expansion joints of 3mm at every 4.88m length wise and 4.992m width wise. Note:-Wooden packing of appropriate thickness to be provided at rear of strut to bring finish inline with Subtex NRC finish.The system is backlined with Anutone SynthPF 10x10 adhered on wall with dab spots of Anutone stick S7 adhesive., including Anti Termite Treatement.Technical Parameters Product Picture• Fire (Class) – 1 & P • Acoustics – NRC 0.75( For L32 C40 Mounting)• Thermal conductivity (W/mk)– na• Climate (°C, RH) – 50, 70• Light reflectance (%) – 75 (Maple Arce)• Green (VOC, RC %) – E1, 25 |
| 392 | Wood Panel for Walls, Back Fire Panel Spectator and Target Area Providing & Fixing Imported PineWood 25 mm thick 4\" width, both side chamfering, Front side machine grinding for smooth surface with water based painting (Apex) on both front and rear sides etc. |
| 393 | Providing & Fixing ofhigh grade, glass fibre reinforced acoustical gypsum wall dado of KNAUF DANOLINE DANOLOFT(3.5x3.5mm square perforation with c/c distance of 8.33mm) in 600x600x12.5mm. Its a concealed sysytem with system D+ giving seamless look with end to end perforation on the tile and screw fixed on Knauf Ceiling perimeter channels 31 x 27x 15 X 0.50mm with the help of nylon sleeves and Knauf Hammer fixing 6X 40 mm and suspending Knauf intermediate channels of 45 x 15 X 0.70 mm from the Knauf L angle and Wedge anchors 6 X 40 mm to be fixed at a distance of 1220mm and with the help of Knauf LN screws 3.5 X11 mm . Knauf Ceiling section 49 X79 X0.50 mm thick with flanges 7 mm each are fixed perpendicular to Knauf intermediate channelusing in line on both horizontal and vertical levels . Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment.The tiles are painted , have Humidity Resistance (RH) of 90%, NRC 0.8 , Light Reflection: 82.6% according to DIN Norm 5036, Fire Performance Class A2-s1,d0 suitable for Green Building application, with Recycled content of 81% and weight 8 kg/m2. • Manufactured from high grade non-combustible glass fibre reinforced gypsum board produced according to EN 520.Including Anti Termite Treatement.Suspension: Concealed screw fixed system with Danoloft Screws• Distance between load-bearing sections c/c 300 mm. Sections width of 60mm.• Distance between hangers and spacers ≤ 900 mm.• Distance from wall to first hanger and spacer ≤ 100 mm.• Location of edge section: Lower edge of edge section = lower edge of finished ceiling.Price is including removal of wall panelling. |
| 394 | Providing & Fixing ofhigh grade, glass fibre reinforced acoustical gypsum ceiling of KNAUF DANOLINE CONTUR UNITY 3(3.5x3.5mm square perforation with c/c distance of 8.33mm) in 600x600x12.5mm. Its a concealed sysytem with system D+ giving seamless look with end to end perforation on the tile & point demountability.The tiles are pre painted with RAL 9003, have Humidity Resistance (RH) of 90%, NRC 0.8 , Light Reflection: 82.6% according to DIN Norm 5036, Fire Performance Class A2-s1,d0 suitable for Green Building application, with Recycled content of 81% and weight 8 kg/m2. • Manufactured from high grade non-combustible glass fibre reinforced gypsum board produced according to EN 520, including Anti Termite Treatement.Suspension: Concealed grid system• Distance between load-bearing sections c/c 600 mm.• Distance between hangers and spacers ≤ 1500 mm.• Distance from wall to first hanger and spacer ≤ 100 mm.• Location of edge section: Lower edge of edge section = lower edge of finished ceiling.Price is including removal of ceiling. |
| 395 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plasteredsurfaces includingscaffoldingifnecessary,preparing the surface bythoroughlycleaningoil,grease,dirtandother foreign matter and sand papering as required etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 396 | Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylicwall putti etc. complete. Spec.No.:- As directed by Engineer in charge. |
| 397 | Supply & Installation of 3.45 mm thick hetrogeneous PVC Vinyl flooringof certified by EN( Europian Standard) 14904, in rolls form of 2m wideand 23m long, total weight 3295 g/m2, Shock Absorption as per EN14808 - 6%, Friction as per EN 13036-4 - 80 to 110, Verticaldeformation as per EN 14809 - 0.4mm, Vertical Ball Behaviour as perEN 12235 - 98%, 100% recyclable, VOC emission after 28days lowerthan ≤10μg/m3, Phthalate Free. The laid flooring shall comply the firerating CFL S1 as per EN 13501-The joints should be thermo weldedwith matching welding rods provided by the manufacturer. After weldingthe flooring will be seamless.The sub-surface should be absolutely atone level (Zero) for installing vinyl flooring. |
| 398 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removingtheexcavatedmaterialuptoadistanceof50m.beyondthebuildingareaand stackingandspreadingasdirected,dewatering,preparingthebedforthefoundationand necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical MeansSpec. No.:- Bd.A.1 Page One Number 259 |
| 399 | ProvidingpreconstructionalantitermitetreatmentasperI.S.6313(Part-II)bytreatingthe bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percentofchlorophyrifospersquaremeterofsurfaceareacovering10yearsguaranteeon bond paper.Spec. No.:- As directed by Engineer in charge. |
| 400 | Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surfaceofplinthfillingattherateof5litresofemulsionconcentrateat1.0percentof clorophyrifosperOne Square Metre of surface area covering ten years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 401 | Providingdry/trap/granite/quartzite/gneissrubblestonesoling15cmto20cmthick including hand packing and compacting etc. complete.Spec. No.:- Bd.A. 12 PageOne Number 264 |
| 402 | Providing fly ash brick masonry with conventional / I.S. type fly ash bricksin C.M. 1:6 in foundation and plinth includingbailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.Spec. No.:- As director by engineer in charge and BDG-2 and 5 |
| 403 | ProvidingandlayingCastinsitu/ReadyMixcementconcreteinM-10oftrap/granite/ quartzite/gneissmetalforfoundationandbeddingincludingbailingoutwater,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided,finishingifrequiredandcuringcomplete,withfullyautomaticmicroprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Crushed sand VSI Grade)Spec. No.:- Bd. E. 1 Page One Number 287 |
| 404 | Supplying soft murum at the road site, including conveying and stacking complete. |
| 405 | Spreading hard murum/ soft murrum/ gravel or kankar for side width complete |
| 406 | Providing and Fixing in Position UV stabilised 2 mm thick corrugated Polycarbonate sheet including removing and stacking of existing sheets as directed by Engineer incharge. |
| 407 | Removing G.I. or A.C. sheet roofing including purlins, principal rafters etc. including sorting serviceableandunserviceablematerials,stackingthesameasandwheredirectedinthe compound including scaffolding etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 408 | Electrical Work of Final Range building:-Supplying & laying HMS PVC conduit 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 409 | Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 410 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG MA/BW |
| 411 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 412 | Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit/ casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modulartype switch, earthing and required accessories as per specification No: WGPW/HW |
| 413 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 414 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 415 | Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light withpolycarbonate body, heat sink, integrated HF electronic driver complete &compatible to T8 / T12 LED luminaire by disconnecting starter & ballast ifnecessary. |
| 416 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 417 | Sports Lighting SITC ofRecessed monted 2\"x2\", 36W Recessed 2\"X2\"LED ceiling fixture with system outut≥4200lm. System efficacy is ≥120lm/W.product is with IP20 CRCA powder coated housing. Luminaire shall have satin finished translucence (HET) PC diffuser for Uniform illumination and wider light distribution.LM 80-08 compliant LEDs from reputed makes such as APT Electronics / Cree, / Bridgelux / Lumiled should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current. Proposed CCT s 6500K with CRI>80 & SDCM<5. Driver shuld be DALI comptible.Driver is having efficiency of minimum 85%. p.f. ≥0.95 & THD≤10%.Driver should have 4KV inbuit surge protection is given. Driver should be able to operate at 140 V to 240 V AC supply. |
| 418 | Sports LightingSITC ofIP65Syemmetric medium beam, 100W LED Floodlight luminaire with system efficacy of 110lm/W.system output should not be more than 11000lm for 100W. Power consumption of luminaire should not exceed 100W. CCT should be 5700K with CRI≥ 70. The housing should be made of non-corrosive high-pressure die-cast aluminum to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate.. The Luminaire should have a 4KVSPD duly bolted in the Luminaire .The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be with 0-10V dimable diver. Driver should have short circuit and open circuit protection. Luminaire and Driver both should be BIS approved andCRS no ( individual R no ) should be shared along with LM79 & LM80 during bid submission. Product should have Lifeclass of 50K hours @L70 with PF > 0.95 & THD ≤ 10%..product is designed to operate at (-10) Deg to45deg operating temp. 50,000 Hrs burning life is provided as per L70B50. |
| 419 | Sports LightingSITC of 35W , Suspended / pendent mounted LED 1130mm Linar LED light. System output should not be more than 4000lm .System efficacy is 120lm/W. width of the product should be 50mm. Housing should be of CRCA powder coatedwith high Translucent Polystyrine Diffuser. Proposed CCT is 6500K along with CRI≥80.LM 80-08 compliant LEDs from reputed makes such asAPT Electronics / Cree, / Bridgelux / Lumiled should be provided. Product should have IP20 protection.LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided.Driver shuld be DALI comptible.Driver is having p.f. ≥0.95 with iTHD≤10% Efficiency of driver shuld be minimum 90% with 4KV internal surge protection. Product is suitable to operate in 140 - 270V Ac range. Product should have inbuilt 4KV surge protection.. service life is 5000K as per L70B50. |
| 420 | SITC of Smart Panel with 63Amp 3 phase incomer and 2 outgoings of 32A 3Phase. Panel should have digital energy meter, control unit for monitoring and control, battery for control unit, SPD for control unit, CT, PT and current leak coil. Control unit should be compatible with 3phase and single phase power supply. It should be compatible for exchange of data through CAT6 cable or data sim card. |
| 421 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 422 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 423 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 424 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 425 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 426 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 427 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 428 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 429 | Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 430 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 431 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 432 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 433 | Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WGPW/ SW. |
| 434 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 435 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 436 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 437 | Supplying, erecting & marking SPMCB 40A to 63A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 438 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 439 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 440 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 441 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 442 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 443 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron /GI frame as per specification no. SW-SWR/MCBDB |
| 444 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 445 | Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/1200/ 1400 mm. sweep, complete erected on provided switch board. |
| 446 | Providing & erecting hot dipped galvanised Perforatedtype cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 447 | Providing & erecting hot dipped galvanised Perforated type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 448 | Supplying and erecting PVC box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX. |
| 449 | Supplying and erecting PVC box trunking of size 75x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX. |
| 450 | Supplying and erecting PVC box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX. |
| 451 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic typewith 30/100/300 mA sensitivity with earth leakage trip indication complete asper specification no. SW-RCCB/RCCB |
| 452 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic typewith 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 453 | Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic typewith 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 454 | Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 455 | Supplying, erecting & marking DPMCB 40A to 63A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 456 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 457 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 458 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 10A, 2 pin plug & earth socket and 10A, 3 pin plug top with 10A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame. |
| 459 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame. |
| 460 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 30 A, 3 pin plug & earth socket and 30A, 3 pin plug top with 30A triple pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame. |
| 461 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With PVC accessories on wall / ceiling as per specification No: WG-MA/CON. |
| 462 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 463 | Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/1200/ 1400 mm. sweep, complete erected on provided switch board. |
| 464 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltagegrade up to 1.1 Kv |
| 465 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 466 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 467 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 468 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 469 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 470 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 471 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 472 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 473 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU8) For use of FRLS-XLPE insulation instead of FR-XLPE insulatedarmoured cable increase rates by 5 % |
| 474 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 475 | Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 476 | Supplying and erecting terminal spreaders suitable for 3 pole, up to 250A MCCB (set of 6) |
| 477 | DATA networkingSupplying and installing cat-6 LSZH cable suitable for networking as peR specification no. WG-COC/NC |
| 478 | Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 479 | Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 480 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 481 | Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. |
| 482 | Supplying and fixing tool-less shutter keystone jack (RJ-45) in provided patch panel complete as per specification no. WG-NAS/KJ |
| 483 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 484 | Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-D in position as per specification No. WG-COC/PC |
| 485 | Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 486 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 487 | VOICE networkingSupplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 488 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 489 | Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 490 | Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 491 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW |
| 492 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW |
| 493 | Supplying and erecting modular type T.V. socket single outlet, duly erected onprovided plate and box with wiring connections complete. |
| 494 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 495 | S u p p l y i n g& erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wallcomplete. |
| 496 | FIRE ALARM SYSTEM EQUIPMENTSupplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. |
| 497 | Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP. |
| 498 | Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300μA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/ SD. |
| 499 | Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI |
| 500 | Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area\"s etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD. |
| 501 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \"Break Glass\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. |
| 502 | Supplying, installing, testing and commissioning of addressable fire control/ relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM. |
| 503 | Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM. |
| 504 | Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM. |
| 505 | Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. |
| 506 | Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. |
| 507 | Supplying, installation, testing & commissioning of fire fighter phone. jack complete as required. |
| 508 | Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CUNote 1)For item no.13-9-10 to 13-9-13 increase rate by 2% for FRLS |
| 509 | Voice Evacuation System (Public Address System)Supplying, installation, testing & commissioning of 2 zone, voice alarm controller with USB, MP3 player (including 2 zone button paging station) with seamless integration facility with main fire arm panel for voice evacuation complete as required. |
| 510 | Supply, Installation, testing & Commissioning of Single Channel 500W (1X500W)Class-D Amplifier and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection. |
| 511 | Supply, Installation, testing & Commissioning of IP based multi zone touch screen call station for selection of zones, supervision of system status, setting of scheduled broadcasts. The call station shall be truly IP based & do not require any server interface for system operation with the following functions:. Built-in monitoring loudspeaker. Detachable goose-neck microphone. 5\" LCD touch screen display. Audio input |
| 512 | Supply, Installation, testing & Commissioning of 6W Ceiling Recessed Speaker with max SPL @1M/1W 88dB . Frequency response of 125Hz-16KHz. The speaker must have a metal grill & tappings at 6W/3W/1.5W. White color speaker with good aesthetics. |
| 513 | Supply, Installation, testing & Commissioning of 6W Ceiling Surface Speaker (Ceiling Speaker + Back Box) with max SPL @1M/1W 88dB . Frequency response of 125Hz-16KHz. The speaker must have a metal grill & tappings at 6W/3W/1.5W. White color speaker with good aesthetics. |
| 514 | Supply, Installation, testing & Commissioning of 6W Wall Mount Speaker with max SPL @1M/1W 90dB . Frequency response of 200Hz-16KHz. The speaker must have a high impact ABS cabinet & tappings at 6W/3W. White color speaker with good aesthetics. |
| 515 | Supplying and fixing 32 U floor mount server Rack (Dimension-DxWxH - 800X1000x1620 mm) as per specification No. WG-NAS/RAK |
| 516 | Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CUNote 1)For item no.13-9-10 to 13-9-13 increase rate by 2% for FRLS |
| 517 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 518 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware. |
| 519 | S/I/T/Cof Emergency Manual Override 25 Watt Volume Control with conesealed Backbox and accessories etc. |
| 520 | S u p p l y i n g& erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wallcomplete. |
| 521 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 522 | Providing and back filling ground enhancing compound 25 kg bag complete. |
| 523 | Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP. |
| 524 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 525 | Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. |
| 526 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 527 | HVAC Workof Final Range buildingAIR-COOLED FLOOR MOUNTED PACKAGE UNITS :-S/I/T/C of Air-cooled type complete with the following components - Indoor evaporating unit comprising of cooling coils, insulated sand-witched drain tray, 10/20 Micron HDPEwashable filters, blower, inverter type hermetic/ semi-hermatic scroll compressors, electrical junction box etc. Outdoor condensing unit comprising of condenser coils, propeller / axial fans pressure switches / cutouts etc. Necessary Refrigerant Gas and oil charge. Inter-connected 30 RMT each module refrigerating piping of copper duly insulated with EPDM Rubber With Factory fabricated black colour glass cloth. Complete electrical power wiring of Alluminium & control wiring of copper required from indoor and outdoor units. Earthing of the complete system with suitable G.I. wire. Electrical Panel will be complete with necessary starters, fuses, switches, timers, over-load relays, contactors, push button, and indicating lamps, single phasing PREVENTOR etc and ALSO WITH REMOTE CONTROL WITH CORDING. The panel should have 1 No. potential free contactor to connect with central fire detection system. The panel should also have voltage scanner to ensure stabilized power input to the machine. All outdoors units shall be mounted on MS angle base frame structure duly black painted with synthetic epoxy paint.The frame structure shall be mounted on MS plate & serrated rubber pads. Complete clamping and saddling of cabling work covered with P V C conduiting. 21.00TR/8,400 CFM |
| 528 | EXTRA REFREGRENT PIPE (IF REQUIRED)Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 12 mm complete. |
| 529 | Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 16 mm complete. |
| 530 | Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 32 mm complete. |
| 531 | Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 42 mm Complete. |
| 532 | Rigid PVC Drain Piping with InsulationSupplying & erecting HMS PVC conduit 25 mm. dia. With necessary accessories in wall/floor with chiseling appropriately as per specification No: WG-MA/CC. |
| 533 | Supplying & erecting HMS PVC conduit 32 mm dia. With necessary accessories in wall/floor with chiseling appropriately as per specification No: WG-MA/CC. |
| 534 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 22 mm for solar water heater system/AC system. |
| 535 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 32 mm for solar water heater system/AC system. |
| 536 | Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 537 | DUCTING SYSTEMSupplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 538 | Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 539 | Supplying and erecting aluminum powder coated linear grill of suitable size for width length without collar dampers having matching colour with the existing false ceiling and suitable for deflection of 15/30/45 degree. |
| 540 | INSULATIONAcoustic Insulation : Supply & fixing of Acoustic insulation for Supply air duct using 15 mm thick class 1 rating open cell nitrile rubber elastomeric insulation with density of 140-180 kg /m³. The insulation mamafactured as per BS 476 part 7 & which should also meet UL 94 test supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209) should not support microbial growth (ASTM 2180, G21,G22) and should not emit objectionable odors (ASTM C 665)and should have thermal conductivity of 0.04w/m k @ 20 degC as per DIN EN 12667. and water vapor permeanceof 0.10. Adhesive shall be used additionally with VOC level not excedding 50 grms / litre 10 mm thick. |
| 541 | Providing adhesive thermal insulation for supply / return air duct with 19 mm nitrile rubber insulation having Rvalue as per the prevailingrovisions in ECBC-2007. |
| 542 | Dismantling of existing 8 Nos. package units including all connected copper piping, ducting, grilles, insulation, drain lines, electrical connections, and related accessories. Work to be carried out carefully without causing damage to reusable items or surrounding structures. All dismantled materials to be removed from site, and area to be left clean and ready for further work.(Dismantling material handed over to user department)NOTE - AS PER INSTRUCTION FROM SPORTS AUTORITY, BALEWADI |
| 543 | Interior Work & Acoustical refurbishment of 10 Meter Range Building:-Removing cement tiles, or marble or polishedshahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. completeSpec. No.:- As directed by Engineer in charge. |
| 544 | Removing teak wood trellies work with frame including stacking the materials as directed with all leads, lifts etc. complete. |
| 545 | Removingdoorsandwindowswithframesandstackingthematerialsasdirectedwithall leads, lifts etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 546 | Removing the existing cement plaster of any thickness without causing dust nuisance and stacking the debris upto a distance of 50 metres or spreading in the compound and cleaning the site etc.complete.Spec. No.:- As directed by Engineer in charge. |
| 547 | Providing antitermite treatment to the wooden frames of doors/windows of the existing building as perI.S.6313(Part-III) bydrilling 6mm dia.holes at four corners on one side and four corners on other side at a down wardangle of about 45 degree at the junction of wood work and masonary and injecting 150ml.of chlorodane 5% W.C.and sealing by filling putty etc. complete covering 2 years guarantee on bond paper. |
| 548 | ProvidingantitermitetreatmenttothesidesofflooringoftheexistingbuildingasperI.S. 6313 (Part-III) by punching holes 6mm dia. drilled at a distance of 30cm. centre to centre and injecting one percentof chlorodane emulsionconcentrate at the rate of50 mlper hole and sealing by filling putty etc. complete covering 2 years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 549 | Providingantitermitetreatmenttothefor interior surfaces of floor, wall.Scope of Work•Making 3” wide x 9”deep trench along the wall & floor ORDrilling 12 mm diameter holes at the junction of Wall & Floor at 90° angle•Drilling 12 mm diameter holes, 12 inches deep at 1 feet distance C/C•Filling the holes with Termiticide Solution (1lit per hole) ORApplying Termiticide Solution @ 2.25 liter per linear meter in trenches•Filling the holes with cement mortar ORFilling the trenches with soil and treat the top surface with TermiticideSolution @ 1.0 ltr. Per linear meter•Customer is requested to put plinth protectioncomplete covering 2 years guarantee on bond paper.Spec. No.:- As directed by Engineer in charge. |
| 550 | Transportation of excavated & debris from site to disposing site (lead 3km) |
| 551 | Providinginternalcementplaster12mm thickinsinglecoatincementmortar1:4without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete.Spec. No.:- Bd. L.2 Page Number 368 |
| 552 | Providing Mirror polishing to Kota Stone including using all necessary stones and equipments cleaning, washing etc. complete. For Flooring. Spec. No.:- BDM 33.28, Page Number 158 |
| 553 | Providing & Fixing in position Acoustical Doors along with 150x150mm teak wood frame, doors made from 50mm Teak wood frame 600x600ctoc filled with 1000 Gsm synthetic wool 50mm thick and 3mm Tecsound from both sides,12mm waterproof ply & veneer from both sides, including 150mm heavy duty SShinges(Geze/Dormaoreq.)4no each leaf,withDoor-closer(Dorma/Gezeoreq.)including cost of required Cut-Outs,decorative mouldings/finishing-items/melamine polish & Scaffolding as per Architectural & Acoustical Design & Instructions & Complete in all aspects.including all materials labour,finishing etc complete |
| 554 | Supply & installation of Anutone Salon Slats Surco made of pinewood E1 grade fiberboard, melamine/veneer laminated finish, groove perforated slats L16-2 - (2mm grooves @16mm pitch with 27% open area) / L32-2 - (2mm grooves @ 32mm centers with 15% open area) surface density 63g/m2,tongue-groove edge for a seamless look, 5-test fire retardant grade, size 128 x2440x16mm, volume density of base board 700Kg/m3, weight 9Kg/m2 (L16), 10.5Kg/m2 (L32), 11Kg/m2 (L64) installed by using Anutone Strut framework system.The Anutone Strut framework system shall include Anutone Strut CC10 thickness 0.55mm, length 3600mm, knurled web 40mm, depth 10mm and equal flanges 15mm is fastened to the wall positioned vertically at every 600mm centres.Anutone Strut CC18,aluminium core cross channel, thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge & center brackets is then fixed perpendicular to the Strut CC10 with the help of fasteners at every 400mm centersAnutone Slats Surco Plus of size 128x 2440x16mm in then fixed perpendicular to Strut CC18 with suitable edge & centre brackets. Contractor to provide expansion joints of 3mm at every 4.88m length wise and 4.992m width wise. Note:-Wooden packing of appropriate thickness to be provided at rear of strut to bring finish inline with Subtex NRC finish.The system is backlined with Anutone SynthPF 10x10 adhered on wall with dab spots of Anutone stick S7 adhesive., including Anti Termite Treatement.Technical Parameters Product Picture• Fire (Class) – 1 & P • Acoustics – NRC 0.75( For L32 C40 Mounting)• Thermal conductivity (W/mk)– na• Climate (°C, RH) – 50, 70• Light reflectance (%) – 75 (Maple Arce)• Green (VOC, RC %) – E1, 25 |
| 555 | Wood Panel for Walls, Back Fire Panel Spectator and Target Area Providing & Fixing Imported PineWood 25 mm thick 4\" width, both side chamfering, Front side machine grinding for smooth surface with water based painting (Apex) on both front and rear sides etc. |
| 556 | Providing & Fixing ofhigh grade, glass fibre reinforced acoustical gypsum wall dado of KNAUF DANOLINE DANOLOFT(3.5x3.5mm square perforation with c/c distance of 8.33mm) in 600x600x12.5mm. Its a concealed sysytem with system D+ giving seamless look with end to end perforation on the tile and screw fixed on Knauf Ceiling perimeter channels 31 x 27x 15 X 0.50mm with the help of nylon sleeves and Knauf Hammer fixing 6X 40 mm and suspending Knauf intermediate channels of 45 x 15 X 0.70 mm from the Knauf L angle and Wedge anchors 6 X 40 mm to be fixed at a distance of 1220mm and with the help of Knauf LN screws 3.5 X11 mm . Knauf Ceiling section 49 X79 X0.50 mm thick with flanges 7 mm each are fixed perpendicular to Knauf intermediate channelusing in line on both horizontal and vertical levels . Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment.The tiles are painted , have Humidity Resistance (RH) of 90%, NRC 0.8 , Light Reflection: 82.6% according to DIN Norm 5036, Fire Performance Class A2-s1,d0 suitable for Green Building application, with Recycled content of 81% and weight 8 kg/m2. • Manufactured from high grade non-combustible glass fibre reinforced gypsum board produced according to EN 520.Including Anti Termite Treatement.Suspension: Concealed screw fixed system with Danoloft Screws• Distance between load-bearing sections c/c 300 mm. Sections width of 60mm.• Distance between hangers and spacers ≤ 900 mm.• Distance from wall to first hanger and spacer ≤ 100 mm.• Location of edge section: Lower edge of edge section = lower edge of finished ceiling.Price is including removal of wall panelling. |
| 557 | Providing & Fixing ofhigh grade, glass fibre reinforced acoustical gypsum ceiling of KNAUF DANOLINE CONTUR UNITY 3(3.5x3.5mm square perforation with c/c distance of 8.33mm) in 600x600x12.5mm. Its a concealed sysytem with system D+ giving seamless look with end to end perforation on the tile & point demountability.The tiles are pre painted with RAL 9003, have Humidity Resistance (RH) of 90%, NRC 0.8 , Light Reflection: 82.6% according to DIN Norm 5036, Fire Performance Class A2-s1,d0 suitable for Green Building application, with Recycled content of 81% and weight 8 kg/m2. • Manufactured from high grade non-combustible glass fibre reinforced gypsum board produced according to EN 520, including Anti Termite Treatement.Suspension: Concealed grid system• Distance between load-bearing sections c/c 600 mm.• Distance between hangers and spacers ≤ 1500 mm.• Distance from wall to first hanger and spacer ≤ 100 mm.• Location of edge section: Lower edge of edge section = lower edge of finished ceiling.Price is including removal of ceiling. |
| 558 | Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plasteredsurfaces includingscaffoldingifnecessary,preparing the surface bythoroughlycleaningoil,grease,dirtandother foreign matter and sand papering as required etc. complete.Spec. No.:- As directed by Engineer in charge. |
| 559 | Providing and applying pearl/ luster finish paint of approved colour and shade to the existing plaster surface including scaffolding, preparing the surface, applying the acrylicwall putti etc. complete. Spec.No.:- As directed by Engineer in charge. |
| 560 | Supply & Installation of 3.45 mm thick hetrogeneous PVC Vinyl flooring of certified by EN( Europian Standard) 14904, in rolls form of 2m wide and 23m long, total weight 3295 g/m2, Shock Absorption as per EN 14808 - 6%, Friction as per EN 13036-4 - 80 to 110, Vertical deformation as per EN 14809 - 0.4mm, Vertical Ball Behaviour as per EN 12235 - 98%, 100% recyclable, VOC emission after 28days lower than ≤10μg/m3, Phthalate Free. The laid flooring shall comply the fire rating CFL S1 as per EN 13501-The joints should be thermo welded with matching welding rods provided by the manufacturer. After welding the flooring will be seamless.The sub-surface should be absolutely at one level (Zero) for installing vinyl flooring. |
| 561 | Electrical Work of 10 Meter Range building:-Supplying & laying HMS PVC conduit 20 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 562 | Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 563 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG MA/BW |
| 564 | Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW |
| 565 | Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit/ casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modulartype switch, earthing and required accessories as per specification No: WGPW/HW |
| 566 | Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. |
| 567 | Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95,operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 568 | Supplying & erecting ready to use Retrofit T8 LED 18 / 20 tube light withpolycarbonate body, heat sink, integrated HF electronic driver complete &compatible to T8 / T12 LED luminaire by disconnecting starter & ballast ifnecessary. |
| 569 | Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. |
| 570 | Sports Lighting -SITCofRecessed monted 2\"x2\", 36W Recessed 2\"X2\"LED ceiling fixture with system outut≥4200lm. System efficacy is ≥120lm/W.product is with IP20 CRCA powder coated housing. Luminaire shall have satin finished translucence (HET) PC diffuser for Uniform illumination and wider light distribution.LM 80-08 compliant LEDs from reputed makes such as APT Electronics / Cree, / Bridgelux / Lumiled should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall use SMD type LED. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs tested at maximum current. Proposed CCT s 6500K with CRI>80 & SDCM<5. Driver shuld be DALI comptible.Driver is having efficiency of minimum 85%. p.f. ≥0.95 & THD≤10%.Driver should have 4KV inbuit surge protection is given. Driver should be able to operate at 140 V to 240 V AC supply. |
| 571 | Sports Lighting -SITCofIP65Syemmetric medium beam, 100W LED Floodlight luminaire with system efficacy of 110lm/W.system output should not be more than 11000lm for 100W. Power consumption of luminaire should not exceed 100W. CCT should be 5700K with CRI≥ 70. The housing should be made of non-corrosive high-pressure die-cast aluminum to with stand extreme environments. It should have corrosion resistant powder coating to pass NSS of 500 Hrs. Product should be suitable for continuous operation (10-12 Hrs. per day). The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate.. The Luminaire should have a 4KVSPD duly bolted in the Luminaire .The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 3 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be with 0-10V dimable diver. Driver should have short circuit and open circuit protection. Luminaire and Driver both should be BIS approved andCRS no ( individual R no ) should be shared along with LM79 & LM80 during bid submission. Product should have Lifeclass of 50K hours @L70 with PF > 0.95 & THD ≤ 10%..product is designed to operate at (-10) Deg to45deg operating temp. 50,000 Hrs burning life is provided as per L70B50. |
| 572 | Sports Lighting -SITCof 35W , Suspended / pendent mounted LED 1130mm Linar LED light. System output should not be more than 4000lm .System efficacy is 120lm/W. width of the product should be 50mm. Housing should be of CRCA powder coatedwith high Translucent Polystyrine Diffuser. Proposed CCT is 6500K along with CRI≥80.LM 80-08 compliant LEDs from reputed makes such asAPT Electronics / Cree, / Bridgelux / Lumiled should be provided. Product should have IP20 protection.LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided.Driver shuld be DALI comptible.Driver is having p.f. ≥0.95 with iTHD≤10% Efficiency of driver shuld be minimum 90% with 4KV internal surge protection. Product is suitable to operate in 140 - 270V Ac range. Product should have inbuilt 4KV surge protection.. service life is 5000K as per L70B50. |
| 573 | SITC of Smart Panel with 63Amp 3 phase incomer and 2 outgoings of 32A 3Phase. Panel should have digital energy meter, control unit for monitoring and control, battery for control unit, SPD for control unit, CT, PT and current leak coil. Control unit should be compatible with 3phase and single phase power supply. It should be compatible for exchange of data through CAT6 cable or data sim card. |
| 574 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 575 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 576 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 577 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 578 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 579 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 580 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 16 / 18 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 581 | Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. |
| 582 | Supplying and erecting modular type switch 16 / 20 A with indicator, duly erected on provided plate and box with wiring connections complete. |
| 583 | Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 584 | Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 585 | Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF |
| 586 | Point wiring for light/bell/exhaust fan in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification No: WGPW/ SW. |
| 587 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 588 | Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 589 | Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 590 | Supplying, erecting & marking SPMCB 40A to 63A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 591 | Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 592 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 593 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 594 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 595 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 8 ways / phase (24 poles), with door, 1.2mm thickness surface/ flush mounted, IP 43 Protection on iron/GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB |
| 596 | Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron /GI frame as per specification no. SW-SWR/MCBDB |
| 597 | Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete. |
| 598 | Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/1200/ 1400 mm. sweep, complete erected on provided switch board. |
| 599 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 600 | Providing & erecting hot dipped galvanised Perforatedtype cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 601 | Providing & erecting hot dipped galvanised Perforated type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 602 | Supplying and erecting PVC box trunking of size 50x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX. |
| 603 | Supplying and erecting PVC box trunking of size 75x50 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX. |
| 604 | Supplying and erecting PVC box trunking of size 75x75 mm. with accessories on wall/ceiling as per specification No: WG-MA/BOX. |
| 605 | Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic typewith 30/100/300 mA sensitivity with earth leakage trip indication complete asper specification no. SW-RCCB/RCCB |
| 606 | Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic typewith 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 607 | Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetic typewith 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB |
| 608 | Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 609 | Supplying, erecting & marking DPMCB 40A to 63A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB |
| 610 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 12 ways /36 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB |
| 611 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. |
| 612 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 10A, 2 pin plug & earth socket and 10A, 3 pin plug top with 10A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame. |
| 613 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plug top with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame. |
| 614 | Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 30 A, 3 pin plug & earth socket and 30A, 3 pin plug top with 30A triple pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron / GI frame. |
| 615 | Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. With PVC accessories on wall / ceiling as per specification No: WG-MA/CON. |
| 616 | Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW |
| 617 | Supplying and erecting electronic type step regulator for ceiling fan 600/ 900/1200/ 1400 mm. sweep, complete erected on provided switch board. |
| 618 | Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltagegrade up to 1.1 Kv |
| 619 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 620 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 621 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 300 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 622 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 623 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 624 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 625 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 626 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU 8) For use of FRLS-XLPE insulation instead of FR-XLPE insulated armoured cable increase rates by 5 % |
| 627 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU8) For use of FRLS-XLPE insulation instead of FR-XLPE insulatedarmoured cable increase rates by 5 % |
| 628 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (36 poles) or TP MCB of 12 ways (36 poles), with door, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 629 | Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB |
| 630 | Supplying and erecting terminal spreaders suitable for 3 pole, up to 250A MCCB (set of 6) |
| 631 | Supplying, erecting, testing and commissioning of 10kVA capacity online pure sine wave with backup time of 0.30 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, 3 phase input & 1 phase output complete with all protections as per specification no. AP-UPS |
| 632 | DATA networkingSupplying and installing cat-6 LSZH cable suitable for networking as peR specification no. WG-COC/NC |
| 633 | Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. |
| 634 | Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO |
| 635 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background. |
| 636 | Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box. |
| 637 | Supplying and fixing tool-less shutter keystone jack (RJ-45) in provided patch panel complete as per specification no. WG-NAS/KJ |
| 638 | Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP |
| 639 | Supplying and fixing 1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-D in position as per specification No. WG-COC/PC |
| 640 | Supplying and fixing 3 m UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC |
| 641 | Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK |
| 642 | Supplying, fixing, and configuring 48 Ports managed gigabit switch 10/100/1000 Mbps + 4 SFP ports erected in provided rack complete. |
| 643 | Supplying, fixing, and configuring 48 ports managed gigabit switch Layer 2 with 48 10/100/1000 Base-T ports management switch with 4 10GE SFP+ ports erected in provided rack complete. |
| 644 | Supplying, fixing, and configuring 8-ports managed gigabit, Layer-2 switch, 10/100/1000 base-T, POE smart switch plus 2 SFP erected in provided rack complete. |
| 645 | VOICE networkingSupplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete. |
| 646 | Supplying & erecting 2 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 647 | Supplying & erecting 20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 648 | Supplying & erecting 50 pair telephone copper cable 0.5 mm dia. with higdensity polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as per specification No. WG-TW |
| 649 | Supplying, erecting & commissioning MDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 650 | Supplying, erecting & commissioning MDF Box 100x100 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW |
| 651 | Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 32 extensions suitable upto 96 extensions complete.Note :- 1) Add Rs. 38159.00 for additional 16 extension card for digital (hybrid) type EPABX |
| 652 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-6 as per specification No. WG-TW |
| 653 | Supplying & erecting co-axial copper cable low voltage grade tri-shielded RG-11 as per specification No. WG-TW |
| 654 | Supplying and erecting modular type T.V. socket single outlet, duly erected onprovided plate and box with wiring connections complete. |
| 655 | Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match thebackground. |
| 656 | FIRE ALARM SYSTEM EQUIPMENTSupplying, installing, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the 2 loop capacity and capable of supporting upto 250 devices and detectors per loop, with on-board LCD display with min 16 lines of text, operating at 230 V 50 HZ - AC with inbuilt Battery Backup of a minimum 24 hours in normal condition and 30 min in alarm condition, suitable provision for network connectivity, interfacing with third party equipment via a MODBUS/ OPC/ L-ON interface etc. conforming to IS 15908:2021, IS 2189: 2008, EN 54 & VDS / FM/ UL 864 (10th edition) with 3 years replacement warranty FF-AFAS/CP. |
| 657 | Supplying, installing, testing and commissioning of repeater panel with suitable battery backup of a minimum of 24 hours in normal condition and 30 min in alarm condition, 80 backlit alphanumeric LCD display with inbuilt buzzer to indicate fault/fire alarm, manual control keys for silence/mute and to reset the FACP from the repeater station. Panel size shall not more than 175 x 275 x 65 mm conforming to EN 54 or UL approved with 3 years equipment replacement warranty FF-AFAS/RP. |
| 658 | Supplying, installing, testing and commissioning of addressable optical smoke detector, single/twin LED’s with 360 degree view, suitable for low voltage 15 to 32 V DC two wires supply, in-built locking mechanism to check the removal and pilferage of the detector, in built isolation mode, start up current 300μA and alarm condition current shall be maximum 6.5 mA, operating temperature 0°C to 50°C, humidity 0-95% RH, IP 41, conforming to IS 2189: 2008, 11360_1985_Reff2020 EN 54 or UL Approved with 3 years equipment replacement warranty FFAFAS/ SD. |
| 659 | Supplying, installing, testing and commissioning remote response indicators suitable to operate on 5 - 28 V dc supply having FR Polymer ABS Housing complete as per specification no. FF-FAAS/RRI |
| 660 | Supplying, installing, testing and commissioning of intelligent addressable thermal/heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from -20°C to 38°C for fixed-heat and rate-of-rise type detectors and 0°C to 66°C for high heat type detectors, in built isolation mode, suitable for offices/ceiling cable trenches/less ventilation area\"s etc. with 3 years equipment replacement warranty IS : 2175 - 1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD. |
| 661 | Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \"Break Glass\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP. |
| 662 | Supplying, installing, testing and commissioning of addressable fire control/ relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM. |
| 663 | Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM. |
| 664 | Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM. |
| 665 | Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operating voltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH. |
| 666 | Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. |
| 667 | Supplying, installation, testing & commissioning of fire fighter phone. jack complete as required. |
| 668 | Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CUNote 1)For item no.13-9-10 to 13-9-13 increase rate by 2% for FRLS |
| 669 | Voice Evacuation System (Public Address System)Supplying, installation, testing & commissioning of 2 zone, voice alarm controller with USB, MP3 player (including 2 zone button paging station) with seamless integration facility with main fire arm panel for voice evacuation complete as required. |
| 670 | Supply, Installation, testing & Commissioning of Single Channel 500W (1X500W)Class-D Amplifier and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection. |
| 671 | Supply, Installation, testing & Commissioning of IP based multi zone touch screen call station for selection of zones, supervision of system status, setting of scheduled broadcasts. The call station shall be truly IP based & do not require any server interface for system operation with the following functions:. Built-in monitoring loudspeaker. Detachable goose-neck microphone. 5\" LCD touch screen display. Audio input |
| 672 | Supply, Installation, testing & Commissioning of 6W Ceiling Recessed Speaker with max SPL @1M/1W 88dB . Frequency response of 125Hz-16KHz. The speaker must have a metal grill & tappings at 6W/3W/1.5W. White color speaker with good aesthetics. |
| 673 | Supply, Installation, testing & Commissioning of 6W Ceiling Surface Speaker (Ceiling Speaker + Back Box) with max SPL @1M/1W 88dB . Frequency response of 125Hz-16KHz. The speaker must have a metal grill & tappings at 6W/3W/1.5W. White color speaker with good aesthetics. |
| 674 | Supply, Installation, testing & Commissioning of 6W Wall Mount Speaker with max SPL @1M/1W 90dB . Frequency response of 200Hz-16KHz. The speaker must have a high impact ABS cabinet & tappings at 6W/3W. White color speaker with good aesthetics. |
| 675 | Supplying and fixing 32 U floor mount server Rack (Dimension-DxWxH - 800X1000x1620 mm) as per specification No. WG-NAS/RAK |
| 676 | Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CUNote 1)For item no.13-9-10 to 13-9-13 increase rate by 2% for FRLS |
| 677 | Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware. |
| 678 | Providing & erecting hot dipped galvanised cover suitable for perforated type Cable tray manufactured from 18 SWG (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware. |
| 679 | S/I/T/Cof Emergency Manual Override 25 Watt Volume Control with conesealed Backbox and accessories etc. |
| 680 | S u p p l y i n g& erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wallcomplete. |
| 681 | Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI |
| 682 | Providing and back filling ground enhancing compound 25 kg bag complete. |
| 683 | Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with insulating and non-corrosive bond with required joints As per specification no. EA-EP. |
| 684 | Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. |
| 685 | Supplying and erecting annealed bare copper wire of high purity of required sizes used for earthing on wall with necessary copper clamps fixed on wall/cable/conduit with screws complete. |
| 686 | Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. |
| 687 | SITC of 12 Channel Multi-Protocol Dimmer Controller which can support for 0-10V/DALI Broadcast/DSI drivers with Instant visual feedback on channel status for all 12 channels.Device should be capable of connecting 80 DALI drivers per Channel (Total 300 No\"s per device), 100 DSI drivers per Channel (total 375 No\"s Per device) & for 0-10V 50 mA source current & 50mA of sink current Approx. 22 Drivers per channel.Device should have override option on the control itself.Supply Voltage: 100-240AC, system Output DC current 200mA which can support 10 button panels without any additional power supply. Device should also have dry contact Aux input |
| 688 | SITC ofAntumbra Display keypad with Central Display to present multiple pages of functions & system Information User Interface white with white Rim for different zones etc with Fully programmable optionsfor Indivuidual control/ group control/ Scene control/ Tasks etc. Wall mountedon 2M (3.5\"\" X 3.5\"\" size) modularbox. Front cover with Backlight, built in proximity sensor and Loadedicons like presentation scenario, meeting scenario, masterOn/ Off, Powersaving mode etc along with a LED indicator for each operations. Central LCD — Allows for system information to be shown such as temperature, time, channel level and current scene. Button function can change when navigating between the up to 16 pages.Operating on 12V DC @ 35-60mAfrom network.Compliance certifcation : E, RCM, FCC, ICES, EN50491-3, UKCA, RoHSEquivalent to Philips Dynalite item Code: PADPE-WW-X + DACM-DYNET (LSP6) |
| 689 | SITC ofNetwork Power Supply. Power: 15V DC 1.5 Amps regulatedpower supply, designedto supplement the networkDC supply. Supply of 110-240V±14% 50/60Hz . The switchmode design allows the device to be used with a wide range of supply voltageswithout the need for a manual selectorsetting. Size of six-unit DIN-railmount enclosurethat has a circuit breakerprofile. This enablesthe device to be installedin all types of electricalequipment enclosures, includingthose with cover aperturesspecifically designedfor circuit breakers.Certifications: CE, RCM, UKCA, RoHSSimilar to Philips Dynalite DDNP1501 |
| 690 | SITC ofNetworkGatewayto provide integration betweenthe control systemsand Ethernet networks.It is designedto provideremote control of sites and link multiplesites together,using the Internetor a corporate LAN as a backbone. The device supportsthe TCP/IP protocol,with static or DHCP assignedIP addressing. An integralwebserver allows Browserbased control scenarios and full control with iOS/Android Mobile and Tab devices. The interfaceincorporates a Programmable Logic Controller that can processcomprehensive conditional and sequential logic and arithmetic functions and time based events and schedulings. Power: 12-24V DC suppliedby the control system network at 200mA.Certification: CE, RCM, UL/cUL, FCC, ICES, UKCA, RoHSSimilar to Philips Dynalite PDEG |
| 691 | HVAC Workof 10 Meter Range building:-VRV SECTIONOUTDOOR UNITSupplying, erecting, testing and commissioning of 20HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56°C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. |
| 692 | Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (for Indoor Unit) |
| 693 | Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB (for outdoor Unit) |
| 694 | INDOOR UNITSupply, installation, testing and commissioning of VRV / VRF based floor mount type package, room/indoor unit (IDU) having nominal cooling capacity of 16.0TR/6400CFM having EER as per BEE standards and specifications with evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, in built drain pump, expansion device, corded remote control with necessary controls and electrical terminal to receive power supply, etc. having anti-corrosive coating suitable for coastal area with decorative slim dimension suitable floor mounting arrangement, an electronic control console and any additional refrigerant and oil charge as per requirement during installation complete. |
| 695 | Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system. |
| 696 | Providing vaccumising the airconditioner system to 200 micron and charging with R410a refrigerant for AC unit. |
| 697 | Supply Installation Testing & commissioning AHU Controller / distribution kit of suitable capacity for connecting multi VRF ODU to AHU, with a) built in auto restart function, c) with necessary electrical wiring & remote controller. |
| 698 | REFREGRENT PIPE Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge (hard drawn copper pipe for liquid main line and for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 699 | Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge (hard drawn copper pipe for liquid main line and for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system. |
| 700 | DRAIN PIPESupplying and erecting 32/40 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC |
| 701 | Supplying and erecting 40/50 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.8 mm conforming to IS 15778 (CTS Series) with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC |
| 702 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 32 mm for solar water heater system. |
| 703 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 42/50 mm for solar water heater system. |
| 704 | VENTILATION FANSupplying and erecting exhaust fan heavy duty 230 V, A.C. 50 cycles 375/380mm. 900 RPM complete erected in position as per specification no. FG-FN/EXF (500cfm) |
| 705 | LOW SIDE SECTION DUCTINGSupplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 706 | Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 275 microns with galvanization process compliance to IS 2629:1985 to be used for fabrication of boxes panel boards etc. including cutting, bending, drilling, welding, riveting etc. and painting with one coat of red lead paint and 2 coats of enamel paint. |
| 707 | SITC OF Fire Dampers shall meet the fire resistance rating of 2 hours as per UL555 and shall be tested and certified by CBRI.Fire Damper frame shall be galvanized steel of 1.6mm thickness, formed into a C channel in 4-piece construction with flanges suitable for duct connection. Damper Blades shall be single skin galvanized steel of 1.6mm thickness and must have 3 accurately rollformed longitudinal grooves for reinforcement and proper closure and operation. The blades shall be arranged in parallel to provide positive shut off. Each Blade shall have axles supported on both sides with sintered bronze self lubricating bearings turning in an extruded hole in the frame. All Blades shall be interconnected using linkage in the frame section . Each Damper shall be operated through a actuator. Each Damper shall be supplied with a factory mounted sleeve made from Minimum 1mm thick galvanized steel of minimum 250mm length. |
| 708 | Supply / Installation / Testing / commissioning of Actuator With It\"s Cabling and Allow for variable positioning, providing continuous control between fully open and fully closed positions. Modulating actuator typewith 0-10V control signal, Operating Voltage: 24V AC, Temperature Range: -10°C to 50°C (14°F to 122°F), IP54 Environmental Rating, UL listed, CE certified with ensure Integration Control compatibility with your HVAC control system or Building Management System (BMS). |
| 709 | S & F of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core complete all as specified and directed by engineer-in.charge. |
| 710 | S & F of return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core complete all as specified and directed by engineer.in-charge. |
| 711 | Supply, installation, testing and commissioning of manually operated, opposed blade, duct mounted, flanged volume control dampers of required sizes in GI construction with operating mechanism, mounting arrangement, rubber refrigerant kits etc. complete. |
| 712 | Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority. |
| 713 | Supply, fabrication, installation an testing of flexible canvass connections constructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete |
| 714 | Acoustic Insulation : Supply & fixing of Acoustic insulation for Supply air duct using 15 mm thick class 1 rating open cell nitrile rubber elastomeric insulation with density of 140-180 kg /m³. The insulation mamafactured as per BS 476 part 7 & which should also meet UL 94 test supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209) should not support microbial growth (ASTM 2180, G21,G22) and should not emit objectionable odors (ASTM C 665)and should have thermal conductivity of 0.04w/m k @ 20 degC as per DIN EN 12667. and water vapor permeanceof 0.10. Adhesive shall be used additionally with VOC level not excedding 50 grms / litre 10 mm thick. |
| 715 | Supply, Installation, Testing & Commissioning of Thermal Insulation Of Supply Ducts with 25 mm Nitrile Rubber With 7mill black colour factory fabricated class cloth. |
| 716 | ELECTRICAL SECTIONSupplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV |
| 717 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 718 | Supplying, erecting & terminating XLPE armored cable 4 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 719 | Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware in approved manner. |
| 720 | Dismantling of existing 8 Nos. package units including all connected copper piping, ducting, grilles, insulation, drain lines, electrical connections, and related accessories. Work to be carried out carefully without causing damage to reusable items or surrounding structures. All dismantled materials to be removed from site, and area to be left clean and ready for further work.(Dismentling material handed over to user department)NOTE - AS PER INSTRUCTION FROM SPORTS AUTORITY, BALEWADI |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy