| 1 | SCHEDULE \"A\" PART-I(BUILDING WORKS) |
| 2 | Supply & Construction of prefabricated fast eractable modular shelter for SM Bk (18.30 m x 6.10m x 2.70m) including provn of plinth/ fdn with vitrified tiles flooring and plinth protection, Internal and external Electrification & Furniture (Specication and drawing complete all as specified for NIT). Drawing No DGAR/COB/01 Sheet No 01 to 10 attached. |
| 3 | Supply & Construction of Prefabricated fast eractable modular shelter for Offrs/JCOs (10.64 m x 6.10 m x 2.70 m) including provn of plinth/ fdn with vitrified tiles flooring and plinth protection, Internal and external Electfication & Furniture (Specication and drawing complete all as specified for NIT). Drawing No DGAR/COB/03 Sheet No 01 to 10 attached. |
| 4 | Supply & Constr of Pre-fabricatedfast erectable modularshelter for Kote (size 18.30m x 6.10 m X 3.00 m) (Tech Specications & drawings as specified in NIT). Including provn of plinth/ fdn with flooring and plinth protection all as per Drawing No DGAR/COB/04 sheet No 01 to 09 attached in tender. |
| 5 | Supply & Constr of Pre-fabricatedfast erectable modularshelter for Store building (size 18.30m x 6.10 m X 3.00 m) (Tech Specications & drawings as specified in NIT). Including provn of plinth/foundation with flooring and plinth protection all as per Drawing No DGAR/COB/04 sheet No 01 to 09 attached in tender. |
| 6 | Supply & Constr of Pre-fabricatedfast erectable modularshelter for CH/DH (size 20.88m x 9.1m X 2.80m) (Tech Specications & drawings as specified in NIT). Including provn of plinth/ fdn with vitrified tiles flooring, plinth protection and ceiling in dining hall all as pr Drawing No DGAR/COB/02 sheet No 01 to 11 attached in tender |
| 7 | Supply & Construction of Prefabricated fast eractable modular shelter for Security Tower/Sentry Post/Guard Room including Internal and external Electfication (Specication and drawing complete all as specified for NIT). Drawing No DGAR/Engr/COB/115 Sheet No 01/4 to 4/4 attached. |
| 8 | Supply & Constr of Pre-fabricatedfast erectable modularshelter for Signal Centre/MI Room/Company Office(size 18.30m x 6.10 m X 3.00 m) (Tech Specications & drawings as specified in NIT). Including provn of plinth/ fdn with vitrified tiles flooring, plinth protection and ceiling all as per Drawing No DGAR/COB/04 sheet No 01 to 09 attached in |
| 9 | Supply & Constrof PFTS shelter(7.20m x 2.20m) 06 men Toilet Block (Tech Specications & drawings as specified in NIT). Including provn of plinth/ foundation with vitrified tiles flooring, plinth protection, one minimum EWC for each blockand water tank staging all as per Drawing No DGAR/ENGR/COB/114sheet No 01 to 03, Drawing No DGAR/COB/02 sheet No 11/11 attached in tender. |
| 10 | SCHEDULE \"A\" PART-II (SECURITY FENCING, 655.00 Rm in lenght) |
| 11 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kind of soil. |
| 12 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, plinth,posts etc. |
| 14 | Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. 65X65X6 mm angle iron post for both Iron pillar and strut post. |
| 15 | Fencing with welded steel wire fabric fencing with posts of specified material and standard design of size 75 mmx 75mm using 4 mm dia GI wire. |
| 16 | Extra for providing and fixing FI Sup for barbed wire of 40x 6 mm flat iron section. |
| 17 | Painting with aluminium paint of approved brand and manufacture to give an even shade Two or more coats on new work on chain link fencing. |
| 18 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron \"Y\" shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer |
| 19 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. 16.18.1 With G.I. barbed wire |
| 20 | Painting with aluminium paint of approved brand and manufacture to give an even shade Two or more coats on new work on chain link fencing. |
| 21 | SCHEDULE \"A\" PART-III (Internal road, 300.00 Rm in lenght) |
| 22 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. All kinds of soil. |
| 23 | Supplying and laying aggregate of 90 mm to 45 mm size. |
| 24 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 25 | Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. |
| 26 | SCHEDULE \"A\" PART-IV (Retaining wall, 120.00 Rm in lenght) |
| 27 | Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 28 | Providing and laying of position cement concrete of specified grade excliding the cost of centering and shuttering with mix of1:4:8(1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) all work upto plinth level. |
| 29 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1cement : 6 coarse sand). |
| 30 | Random rubble masonry with hard stone in Superstructure above plinth level and upto floor five level,including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) above plinth level with :Cement mortar 1:6 (1cement : 6 coarse sand). |
| 31 | Providing and laying of cement concrete in cooping of R.R masonry retaining walls of specified grade excluding the cost of centering and shuttering with mix of1:2:4(1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) upto floor five level. |
| 32 | Raised and cut pointing in stone work in white cement mortar mix of 1:3 (1 cement: 3 fine sand). |
| 33 | Supplying and stacking at site 20 mm size stone aggregate. |
| 34 | Providing and fixing unplasticised Rigid PVC sewer pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter. |
| 35 | Providing and laying of position cement concrete of specified grade excliding the cost of centering and shuttering with mix of1:2:4(1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) all work upto plinth level. |
| 36 | Providing and laying of position cement concrete of specified grade excliding the cost of centering and shuttering with mix of1:3:6(1 Cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) all work upto plinth level. |
| 37 | SCHEDULE \"A\" PART-V (Storm water drain, 100.00 Rm in lenght) |
| 38 | Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5 m disposal soil to be levelled and neatly dressed . All kind of soil. |
| 39 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kind of soil. |
| 40 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size). |
| 41 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). |
| 42 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1cement : 6 coarse sand). |
| 43 | 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand). |
| 44 | SCHEDULE \"A\" PART-VI (PCC footpath, 110.00 Rm in lenght) |
| 45 | Earth work in surface excavation not exceeding 30cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including disposal of excavated earth upto 50 m and lift upto 1.5 m disposal soil to be levelled and neatly dressed . All kind of soil. |
| 46 | Supplying and laying stone aggregate of 90 to 45 mm size of WBM with moroum as binding material including 13.2mm size stone screening sorting, watering spreading to template, compacting stone aggregate in uniformed thickness and consolodiation with power road roller of 8 to 10 tonne capacity in two layer with proper gradient and camber etc complete(150mm thick ). |
| 47 | Providing and laying of position cement concrete of specified grade excliding the cost of centering and shuttering with mix of1:2:4(1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) all work upto plinth level. |
| 48 | Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. |
| 49 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). |
| 50 | SCHEDULE \"A\" PART-VII (Earth work in excavation in over surface areas) |
| 51 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m. |
| 52 | SCHEDULE ‘A’ PART-VIII(SEWAGE DISPOSAL) |
| 53 | Construction of septic tank 50 users all as per standard specifications and drawing No DGAR/Engr/355 Sheet No 1/1 for toilet blocks |
| 54 | Construction of septic tank 20 users all as per standard specification and drawing No DGAR/Engr/355 Sheet No 1/1 for OJL |
| 55 | Construction of soak pit all as per standard specification and drawing No DGAR/Engr/356 Sheet No 1/1 |
| 56 | Construction of man hole all as per standard specification and drawing No DGAR/Engr/356 |
| 57 | Provn of 110 mm dia PVC (SWR) pipe from manholes to septic tank, and septic tank to soak pit incl PCC 1:3:6 hauncing |