| 1 | Civil Work |
| 2 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means |
| 3 | Excavation for foundation in earth, soils of all types, sand, gravel and soft-murrum, including removing the excavated material up to a distance of 50 meters beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means |
| 4 | Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand-packing and compacting etc. complete. |
| 5 | Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in-charge in layers of 15 cm to 20 cm including watering and compaction etc. complete |
| 6 | Providing and laying Cast in situ/Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, Steel centring, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete.With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc.) |
| 7 | Providing and laying in situ /Ready Mixcement concreteM-20of trap / granite /quartzite/ gneissmetal for R.C.C. workin foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchionsetc. including bailing out water,Steel centring formwork, laying/pumpingcover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) |
| 8 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc.) |
| 9 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centring, formwork, cover blocks, laying/pumping, compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel). With fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan Mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) |
| 10 | Providing andlaying Castin situ/Ready Mix cement concrete M-20 of trap/ granite /quartzite/gneiss metalforR.C.C. slabsand landings as perdetailed designsand drawingsincludingsteelcentering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surfaceorrougheningifspecialfinishistobe providedandcuringetc.complete,(Excluding reinforcementandstructuralsteel).withfullyautomatic microprocessorbasedPLCwithSCADAenabled reversibleDrum Typemixer/concreteBatchmixplant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade). |
| 11 | Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centring, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan Mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) |
| 12 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. Including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 13 | Providing and fixing in position HCRM / CRS (CorrosionResistant Steel) bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. Including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 14 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in plinth as backing in composite masonry including bailing out water manually, striking joints, raking out joints and watering etc Complete |
| 15 | Providing Second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in Superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete. |
| 16 | Providing andfixing colourcoatedZincalume (R)AZ150(min150gms/sq.mt.Total on each side) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi-strength steel with min.550 MPa yield strength,metallichotdipcoatedwithAluminium-Zincalloy(55%aluminium 43.4%zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganicpigment).Thepaintshallhaveatotalcoatingthicknessofnominal35um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm centre- to-centre. The end rib shall be designed for anti-capillary groove. And return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min.fastened with min.25 um Zinc-Tin alloy coated, Hex head, self-drilling screw etc. complete. (Weight of profile 4.52 Kilogram/Square Metre) |
| 17 | Providing internal cement plaster 12mm thick in single coat in cement mortar 1:4 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. |
| 18 | Providing External cement plaster 15 mm thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curingetc. Complete. |
| 19 | Providing and laying Rough Shahabad Stone Flooring 50mm to 60mm thick and of required width in plain/ diamond pattern on a bed of 1:6 C.M. including cement float, striking joints, pointing in cement mortar 1:3 curing and cleaning etc. etc. complete. |
| 20 | Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. |
| 21 | Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sq.m as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. |
| 22 | Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface. (Excluding the primer coat) etc. complete. |
| 23 | Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. |
| 24 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear) |
| 25 | Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. |
| 26 | Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete |
| 27 | Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 kg/Rmt. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight1.070 kg/Rmt.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 kg/Rmt. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 kg/Rmt. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 kg/Rmt. and handle and top section 40 x 18 x 1.25 mm at weight o.417 kg/Rmt. As per detailed drawings and as directed by Engineer-in-charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self-locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc., complete. With colour anodising without box |
| 28 | Providing and laying in situ Tremix Cement Concrete M-20 with tremix treatment for 100 mm thickness for flooring with groove cutting of 4mm wide and 20 mm deep with necessary refilling with bitumen etc. complete. |
| 29 | Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 litres |
| 30 | Turbo Ventilator 24\" : Providing and fixing wind operated turbo ventilator system of various sizes over the existing roof including cutting CGI sheet, proper fixing in position to true line and level with all fixtures and fastenings including etc. complete. |
| 31 | Electric Work |
| 32 | Supplying,erecting&terminatingXLPEarmouredcable3 core6sq.mm.copperconductorcontinuous5.48sq.mm. (12SWG)G.I.earthwirecompleteerectedwithglands& lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 33 | Makingtrenchofsuitablewidthanddepthinhardmurum/ tar roadfor layingprovided LTcable upto andincluding 16 sq. mm complete as per specification no. CW-EXNCTR |
| 34 | Makingtrenchofsuitablewidthanddepthinsoftsoilfor layingprovidedLTcableuptoandincluding16sq.mm complete as per specification no. CW-EXN-CTR |
| 35 | Supplying & erecting mains PVC unarmoured cable 1100Volt gradeISImark3core/2.5sqmmstranded/solidcopper completeerectedonwallwithdulypaintedG.I.Saddle@ |
| 36 | Supplying & erecting weatherproof powder coated distribution board 4 way with 2 x 6/10 Amp S. P. M. C. B. with industrialtwopinplugsocket10Aand3pinplugtop10A with top cover necessary connection etc complete withapproved make. |
| 37 | ProvidingpointwiringforstreetlightwithPVCunarmoured cable1100VoltgradeISImark3core1.5sqmmstranded/ solid copper erected on wall with G. I. Saddle duly painted @ 0,25 m C/C rigidly grouted in the wall with the help of platedscrew including 4” x 4” M. S. box 2 way with epoxy painting & |
| 38 | Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22/E-27 base. |
| 39 | Supplying and erecting LED street light fitting suitable for20 to25W,withPF>0.95classIP65andabovehousingof pressurediecastaluminiumalloyandheatsinkextruded aluminium complete as per specification No FG-ODF/FLS |
| 40 | SupplyinganderectingstreetlightWallbracketmadefrom 40 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete as per specification no. FG-BKT/WB |
| 41 | Providing earthingwith galvanizediron earthplate size60 x 60x 0.6cmcompletewithallmaterials,testing&recording the results as per specification no. EA-EP |
| 42 | Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP |
| 43 | Supplying, erecting & marking DPMCB 6A to 32A,C- series (for motor/power) in provided distribution board as per specification no. SW-SWR/MCB |
| 44 | Supplying,erecting&markingSPMCB6Ato 32A,B- series (for lighting) in provided distribution board as per specificationno. SW-SWR/MCB |
| 45 | SupplyinganderectingGIsheet1.6mm(16SWG)tobe usedforfabricationofboxespanelboardsetc.including cutting,bending,drilling,welding,rivetingetc.andpainting with one coat of red lead paint and 2 coats of enamel paint. |
| 46 | Supplying and erecting marine plywood 18/19 mm thick fixed towall or onprovided panel board withnecessary materials such as screws, wall fasteners, supports, nut bolts etc.complete. |
| 47 | Supplyinganderectingtriplepoleandneutraldistribution board(TPNDB)surface/flushmountedsuitableforSPMCB of 12 ways on iron / GI frame (horizontal busbar type) as perspecification no. SW-SWR/MCBDB |
| 48 | Supplying&erectingG.I.pipe‘A’ class25mmdia.erected forenclosing XLPE armoured cable onwall/pole asper specification no. CB-CE |
| 49 | Supplying & erecting G.I. pipe ‘A’ class 40 mmdia. erected forenclosing XLPE armoured cable onwall/pole asper specification no. CB-CE |
| 50 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosingcable belowground/road surface, to required depth complete. |
| 51 | Supplying&erecting18guageM.S.Boxpowdercoated (4\"x4\") 3 way for mains connection. |
| 52 | Supplying & erecting Siemens type brass cable glands for 3 to4core6sq.mm./2to4core10sq.mm.forXLPE armoured cable as per specification No. CB-GL |
| 53 | Supplying shockproof type hand lamp with lamp holder, bulb/ lamp100Wguardedglass and30 mtr.3 corePVC flexible |
| 54 | Point wiring for independent plug in 20 mm ISI markedHMS PVCconduitwith1.5sq.mm(2+1E)FRLSHgrade copper wire, flush type switch, earthing and requiredaccessories asper specification No: WG-PW/SW |
| 55 | SupplyinganderectingStreetlightbracketmadefrom25 mm. dia ‗B‘ class G.I. Pipe, 0.6 min length along with pole capof300mmlengthand80mmdiadulyweldedwith provided leads as per specification no. FG-BKT/BPC |
| 56 | Supplying&erectingmainswith2x2.5Sq.mmstranded copper PVC insulated wire with 2 x 1.5Sq.mmcopper PVCwire in PVC casing - caping20 mm on wall / ceiling. |
| 57 | Supplying&erectingmainwith2x4.00Sq.mmstranded copper PVC insulated wire with 2 x 1.5Sq.mmcopper PVC wire in PVC casing - capingon wall / ceiling. |
| 58 | Supplying and erecting double pole switch surface type/ flush type240V,32Awithindicator lamp&fuseas perspecification no. SW-SWR/BDP. |
| 59 | Supplying and erecting double pole metal clad switch withHC type fuse and neutral link 240V, 32A on iron / GI frame as perspecification no. SW-SWR/MDP .. |
| 60 | Supplying&erecting3W,230VintegraltypeLEDLamp suitable for B-22/E-27 base. |
| 61 | Supplying and erecting T8 Fluorescent tube day light 1200mm 36 W |
| 62 | Supplying&erectingreadytouseRetrofitT8LED18/20 tubelightwithpolycarbonatebody,heatsink,integratedHF electronicdrivercomplete&compatibletoT8/T12LED luminaire by disconnecting starter & ballast if necessary. |
| 63 | Supplying and erecting regular/ standard model ceiling fan of 900/1050mm.sweepcompleteerectedinpositionasper specification no. FG-FN/CF |
| 64 | Supplying and fixing wiremesh (Jali) cover suitable for fitting / fanorforanypurpose,completewithnecessarymaterials.The jali cover shall be made from good quality G.I. wire mesh |
| 65 | Supplyinganderectingdingdong/electronicmusicaltype call bell with heavy duty coil suitable to operate on 230V A.C. supplyerectedonpolisheddoublewoodenblock/sunmicablock of suitable size |
| 66 | SupplyinganderectingstreetlightWallbracketmadefrom 25 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete as per specification no. FG-BKT/WB |
| 67 | Supplying & erecting CRCA sheet metal one wayenclosures suitable for DP MCB /TP MCB /FP MCB erected on angle iron/GI frame complete. |
| 68 | Supplying erecting and marking four pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board complete. |
| 69 | PEB Work |
| 70 | Supplying, Fabricating ,erecting & fixing in position of steel structures at all elevations using fusion welding quality steel E-350 (Fe 490) conforming to IS :2062 -2006. Rate shall be include cost of cutting, welding ,splice plates,& packing plates, transporting, straighten ,cleaning, fabricating,& erecting in position weled /bolted structural steel work in columns,beams,trusses,purlins,platforms,ladder,momorails,staircass ,supports, strengthen of steel members, etc. at site to line & level, supply of approved bolts/nuts/washers etc. complete as per drawing including painting as per G/4,G/5,G/6 before erection& all material & labor charges etc. complete& including sand blasting & painted withone coats og enamel paint (Berger EPILUX SG-HHI 664002) of 35-50 micron each coat with air less spary gun over a coat of zinc chromate primer-35-35 micron etc. complete as shownin drawings as per specifications and as directed by Enginner- in-charge (The Rate quoted shall include cost of bolts, nuts,washers,welding & electrodes required fot complete work). |
| 71 | Supplying,Fabricating,erectingof Cold Formed Light GaugestructuralSteel members conforming to IS:801/IS: 811 hot dip galvanised to IS:4759-96 including cutting,welding or bolting,splice plates , transporting,straghtnening,cleaning,fabricating & erececting in position |
| 72 | Supplying & Fixing ofPPGI Sheets ot 0.5 mm thick as shown in drawingor as directed by engineer in charge.( Essar Make) |
| 73 | Supplying & Fixing of 0.5 mm thk PPGL roof accessories as per drawingor as directed by engineer in charge. |
| 74 | Supplying & fabricating & erecting in position PPGI Eaves Gutter of required size with stop ends, all fixing accessories, dtop ends,etc. all elevations levels & heights incluiding, alinging,leveling,providing& fixing nut bolts,washers etc.as directed by engineer in charge. |
| 75 | Providing & Fixing of the rain water down take pipes Of PPGI , the sectional area of rain water down take pipe provided shallbe generally at the rate of 1 Sq.cm/ 70 to 80 Sq. decimetre of roof area drained. No Spout shall be less than 80 mm in diameter. The spacing of spouts shallbe arranged to suit the position of opening in the wall including all materials & labours charges etc. as per drawing or as directed by engineer in charge. |
| 76 | BITUMINOS ROD |
| 77 | Trimming of grass, shurbs and weeds from the shoulders/berms and disposing off the same to suitable locations etc. complete |
| 78 | Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment orstacking as directed. |
| 79 | Excavation for roadway in hard murum and boulder including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m.and spreading for embankment or stacking as directed. |
| 80 | Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. |
| 81 | Supplying trap/granite/quartzite/gneiss stone metal of required size by bringing the boulders / Rubble at the road side breaking them to required gradation including conveying the boulders /Rubble and stacking the broken metal etc. complete . (Prior approval of sample stack of broken metal by the Ex. Engineer is necessary the date of approval will form part of the measurements) a)80 mm Metal, By breaking rubble obtained by blasting.(Hand broken). with prior approval of concerned SuperitendingEngineer. |
| 82 | Supplying trap/granite/quartzite/gneiss stone metal of required size by bringing the boulders / Rubble at the road side breaking them to required gradation including conveying the boulders /Rubble and stacking the broken metal etc. complete . (Prior approval of sample stack of broken metal by the Ex. Engineer is necessary the date of approval will form part of the measurements) a)40 mm Metal, By breaking rubble obtained by blasting.(Hand broken). |
| 83 | Spreading 80 mm metal for road work including sectionong etc complete as directed by Engineer in charge |
| 84 | Spreading 40 mm metal for road work including sectionong etc complete as directed by Engineer in charge |
| 85 | Supplying hard murum/ kankar at the road site, including conveying and stackingcomplete. |
| 86 | Spreading hard murum/ soft murrum/ gravel or kankar for side width complete |
| 87 | Compacting the sub grade/gravel/oversize metal (200 mm loose) layers for all width with Vibratory roller having weight 8 to 10 MT. including necessary, labour, materials andartificial watering complete. |
| 88 | Compacting the hard murum side widths including laying in layers on each side withvibratory roller including artificial watering etc. complete. |
| 89 | Providing and constructing 75 mm. thick Modified Penetration Macadam (MPM) road surface including all materials, preparing the existing road surface, spreading 40 mm. stone metal layers 30% crusher broken metal + 70% Hand broken (by breaking rubble obtained by blasting) heating and spraying the bitumen of specified grade @ 2 Kg/sqm, spreading 12 mm.size chips compacting with three wheel static roller having weight 8 to 10 MT. to achive the desired degree of compaction as per Technical Specification Clause 506 etc. complete. Including picking of existing WBM surface. (VG-30 bulk bitumen rates are considered to arrive at rates) |
| 90 | Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on B.T. surface 2.5 kg/10 sqm.(VG-30 bulk bitumen rates are considered to arrive at rates) |
| 91 | Open Graded Premix Surfacing- Providing and Laying OGC 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates premixed with bituminous binder transported to site with VTS , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction but excluding prime / tack and Seal coat. For Bitumen of specified grade--USING drum mix type hot mix plant with SCADA, Paver and Vibratory roller ( Over MPM Surface) (VG-30 bulk bitumen rates are considered to arrive at rates) |
| 92 | 9 MM SEAL COAT: Providing and laying of Type A 9mm premix seal coat with HMP of apropriate capacity crushed stone chiping 6.7 mm size and penetration bitumen of specified grade @ 1.2kg/Sq.m, preparing existing road surface by mechanical means, spreading chips and rolling, by static roller having weight 8 to 10 MT. etc. complete.(VG- 30 bulk bitumen rates are considered to arrive at rates) |
| 93 | Providing and fixing R.C.C.1:2:4 guard stone as per type design including |
| 94 | Royalty |
| 95 | Sand |
| 96 | Other Minerals |
| 97 | Lab Test |
| 98 | Sand- Fineness Modulus,silt and clay content |
| 99 | Aggregate/Crush material a) Carrying out water absorption b)specific gravity c) Impact Valued) Crushing Value |
| 100 | Cement- Cement- Standerd Consistency,fineness, , Setting Time (Initial And Final), compressive strenght, soundness |
| 101 | Concrete M10 Grade- Concrete cube Compressive Strength (set of 3 cubes) |
| 102 | Concrete M20 Grade- Mix design M20 with all tests on besic materials |
| 103 | Concrete M20 Grade- Concrete cube Compressive Strength (set of 3 cubes) |
| 104 | TMT steel bars- Steel - Tensile strength,Yield stress, ultimate tensile stress,%elongation, weight per running meter, Bend/Rebend test.(Set of 3 Bars) upto 16 mm (set of 3 bar) |
| 105 | Murum plasticity Index, fild density of compacted layer, proctor test |
| 106 | Bricks: Crushing Value, Absorption Value, Specific gravity |
| 107 | ESHS |
| 108 | ESHS Plan |