| 1 | Material and labour for servicing of 750 KVA DG Set by carrying out the following maintenance including testing oncompletion at connected laod for entiresatisfaction of Engr-in-Charge and complete all as specified and directed at site.(i) Draining out engine oil feom thesump by removing drain plug,cleaning the sump throughly andrefilling the sump with new engine oil to required level (Note : Engine oil will bemeasured and paid separately)(ii) Replacecompletefuel filters, oil filters and air filter element.(Note : fuel filters, oil filters and air filter element will bemeasured and paid separately)(iii) Drainingout complete coolant watermixture from the radiator and refilling theradiator withnew coolent and water mixture with proportionate ratio (Note : coolent will bemeasured and paid separately as Supply only)(iv)Draining outdiesel from disel tank and storing in cleaned containers,cleaning the tank throughly by removing sediments settled at the bottom and refilling the drained out diesel duly filtered.(v) Check and top up the electrolyte/distilled water in starting batterie cells to maintain the required specific gravity.Cleaning of battery terminals & applying petroleum jelly to battery poles & brass connectors.(vi) Tightening all the fastenersof complete DG set to therequired torque.(vii)Tightening of all gaskets, connection of battery terminals, cable connections, foundation bolts, coupling bolts etc including test running and tappet setting of alternator by checking and setting of voltage and frequencies complete. |
| 2 | All as per ser item No 1 here-in-before but Cap of DG Set320KVA |
| 3 | All as per ser item No 1 here-in-before but Cap of DG Set180/160 KVA |
| 4 | All as per ser item No 1 here-in-before but Cap of DG Set 125/100 KVA |
| 5 | All as per ser item No 1 here-in-before but Cap of DG Set 70/62.5 KVA |
| 6 | All as per ser item No 1 here-in-before but Cap of DG Set 45/40/35 KVA |
| 7 | All as per ser item No 1 here-in-before but Cap of DG Set 30/25 KVA |
| 8 | Supply only Pre filter cartridge suitable for 750 KVA DG set (Set of Two) |
| 9 | Supply only Finalfilter cartridge suitable for 750 KVA DG set (Set of Two) |
| 10 | Supply only disel filter suitable for320 kVA DG set |
| 11 | Supply only disel filter suitable for180/160 kVA DG set |
| 12 | Supply only disel filter suitable for100 kVA DG set |
| 13 | Supply only disel filter suitable for70/62.5 kVA DG set |
| 14 | Supply only disel filter suitable for 45/40/35 KVA DG set |
| 15 | Supply only disel filter suitable for 30/25 KVA DG set |
| 16 | Supply only oil filter suitable for750 kVA DG set (Set of Two) |
| 17 | Supply only oil filter suitable for320 kVA DG set |
| 18 | Supply only oil filter suitable for180/160 kVA DG set |
| 19 | Supply only oil filter suitable for100 kVA DG set |
| 20 | Supply only oil filter suitable for70/62.5 kVA DG set |
| 21 | Supply only oil filter suitable for 45/40/35 KVA DG set |
| 22 | Supply only oil filter suitable for 30/25 KVA DG set |
| 23 | Supply only air filter safetysuitable for750 kVA DG set |
| 24 | Supply only air filter primary suitable for750 kVA DG set |
| 25 | Supply only air filter suitable for320 kVA DG set |
| 26 | Supply only air filter suitable for180 /160 kVA DG set |
| 27 | Supply only air filter suitable for100 kVA DG set |
| 28 | Supply only air filter suitable for70/62.5 kVA DG set |
| 29 | Supply only air filter suitable for 45/40/35 KVA DG set |
| 30 | Supply only air filter suitable for 30/25 KVA DG set |
| 31 | M&L for drain out the old unsv engine oil from sump of DG sets & cleaning &n refilling with new engine oil 15 W 40 up to required level including top up complete all as specified and directed at site. |
| 32 | M&L fordrain out old coolant from radiator and topup ofbest qualitypremixed coolantsinradiator of any capacity DG set complete all as specified and directed at site. |
| 33 | M&L fortop up of distilled waterin DG set battery as per required level complete all as specified and directed at site. |
| 34 | Attending of emergency complaint in any breakdown of standby DG Sets/AMF panels up to 320 KVA DG set at any placein AF Stn Chabua,whenever required round theclock, rectify the fault and restore the standby supply with in8 hrs after receipt of the complaintother wise a recovery of Rs. 500 / per day recovered from the contractor. |
| 35 | De-scaling of radiator assembly by carefully from the engine,transporting to civil workshop and removing the sediments,scales andrust etc by means ofchemical cleaning,high pressure water washing and air cleaning, arresting the leakages by gas welding/soldering with suitable material, and re-assembling the same with new gaskets including replacement ofradiator cap(whereever required) and transporting tothe site, fixing to theengine for DG set of capcity 750 KVAand testing forsatisfactory performance complete all as specified and directecd at site. |
| 36 | All as per ser item No 35 here-in-before but Cap of DG Set320 KVA |
| 37 | All as per ser item No 35 here-in-before but Cap of DG Set180/160 KVA |
| 38 | All as per ser item No 35 here-in-before but Cap of DG Set100 KVA |
| 39 | All as per ser item No 35 here-in-before but Cap of DG Set70/62.5 KVA |
| 40 | All as per ser item No 35 here-in-before but Cap of DG Set45/40/35 KVA |
| 41 | All as per ser item No 35 here-in-before but Cap of DG Set30/25 KVA |
| 42 | Dismantling thedefectivefuel injectors & FIP from theengine andmaterial and labour forrepair/calibration offuel injectors , nozzle repair with pressure checkincluding replacement ofbarrel plunger,Nozzels,)element,dilevery valve, Injector,cups,\"O\" rings etc as per site requirement of750 KVA DG setcomplete all as specified and directed at site. |
| 43 | All as per ser item No 42 here-in-before but Cap of DG Set320 KVA |
| 44 | All as per ser item No 42 here-in-before but Cap of DG Set180/160 KVA |
| 45 | All as per ser item No 42 here-in-before but Cap of DG Set100 KVA |
| 46 | All as per ser item No 42 here-in-before but Cap of DG Set70/62.5 KVA |
| 47 | All as per ser item No 42 here-in-before but Cap of DG Set45/40/35 KVA |
| 48 | All as per ser item No 42 here-in-before but Cap of DG Set30/25 KVA |
| 49 | Supply and fixing in repair solenoid coil suitable for DG set of capacity 750 KVA complete all as specified and directed at site. |
| 50 | All as per ser item No 49 here-in-before but Cap of DG Set320 KVA |
| 51 | All as per ser item No 49 here-in-before but Cap of DG Set180/160 KVA |
| 52 | All as per ser item No 49 here-in-before but Cap of DG Set70/62.5 KVA |
| 53 | All as per ser item No 49 here-in-before but Cap of DG Set45/40/35 KVA |
| 54 | All as per ser item No 49 here-in-before but Cap of DG Set30/25 KVA |
| 55 | M& Labour in repairof self starter 24 volt ,dismantlingfrom DG set of Cap 750 KVAand shifting to workshop and back for and including replacement of spare parts such as armature,housing bush,solonoid switch,pinion,pinion lock,rocker, rocker cap bush, frog, frog adjustment bolt,field coil,carbon brush,,armatur shat/comutator shaft ,adjusting bolt, centre plate bush,comutator fiber/steel washer carrying outfollowingrepair works , |
| 56 | All as per ser item No 55 here-in-before but Cap of DG Set320 KVA |
| 57 | All as per ser item No 55 here-in-before but Cap of DG Set180/160 KVA |
| 58 | All as per ser item No 55 here-in-before but Cap of DG Set100 KVA |
| 59 | M& Labour in repairof self starter 12 volt ,dismantlingfrom DG set of Cap 70/62.5 KVAand shifting to workshop and back for and including replacement of spare parts such as armature,housing bush,solonoid switch,pinion,pinion lock,rocker, rocker cap bush, frog, frog adjustment bolt,field coil,carbon brush,,armatur shat/comutator shaft ,adjusting bolt, centre plate bush,comutator fiber/steel washer carrying outfollowingrepair works , |
| 60 | All as per ser item No 59 here-in-before but Cap of DG Set45/40/35 KVA |
| 61 | M&L for complete painting of 750 KVA DG set of make:- Kirloskar with alternator ,base plateby using heat resistant paint with spray gun over existing surfaceas per existing colour code after taking outold paint ,dirt and dust from the DG setbody,alternator and engine complete all asspecified and directed by Engr-in-Charge. |
| 62 | All as per ser item No 61 here-in-before but Cap of DG Set320 KVA |
| 63 | All as per ser item No 61 here-in-before but Cap of DG Set180/160 KVA |
| 64 | All as per ser item No 61 here-in-before but Cap of DG Set100 KVA |
| 65 | All as per ser item No 61 here-in-before but Cap of DG Set70/62.5 KVA |
| 66 | All as per ser item No 61 here-in-before but Cap of DG Set45/40/35 KVA |
| 67 | All as per ser item No 61 here-in-before but Cap of DG Set30/25 KVA |
| 68 | Dismantling the defective turbocharger suiatble for 750 kVA Dg Set and Repair/maint ofTurbo charger suitable for 750 KVA Generator set of any ,make and type complete all as per specified and directed at site. |
| 69 | Dismantling the defective turbocharger suiatble for 320 KVA DG Set and Repair/maint ofTurbo charger suitable for 320 KVA Generator set of any ,make and type complete all as per specified and directed at site. |
| 70 | Dismantling the defective turbocharger suiatble for 180/160 KVA DG Set and Repair/maint ofTurbo charger suitable for 180/160 KVA Generator set of any ,make and type complete all as per specified and directed at site. |
| 71 | Dismantling the defective turbocharger suiatble for 125/100 KVA DG Set and Repair/maint ofTurbo charger suitable for 100 KVA Generator set of any ,make and type complete all as per specified and directed at site. |
| 72 | Dismantling thedefective water pump assembly and repair/maint of water pump assembly suitable forDG set of capacity 750 KVAcomplete all as specified and directed at site. |
| 73 | Dismantling thedefective water pump assembly and repair/maint of water pump assembly suitable forDG set of capacity 320 KVAcomplete all as specified and directed at site. |
| 74 | Dismantling thedefective water pump assembly and repair/maint of water pump assembly suitable forDG set of capacity 180/160 KVAcomplete all as specified and directed at site. |
| 75 | Dismantling thedefective water pump assembly and repair/maint of water pump assembly suitable forDG set of capacity 45/40/35 KVAcomplete all as specified and directed at site. |
| 76 | M & L for rewinding of DG set alternator/Stator/Rotor coil /Rectifier Coil Unitof any capacity with super enemelled copper wire of existing gauge incluiding all connected insulating material, varnishing, replacement of carbon bushes including disconnection/dismantling of electrical connections, foundation bolts, pulling out of rotor with proper care and reinsulation of burnt out rotor/stator after rewinding work including re-assembling and testingon siteincludingtaking out alternator fromAF Stn Chabuato auth workshop andafter repair from workshop tositecomplete all as specified and directed at site. |
| 77 | M & L for repair/rewinding of 750 KVA DG set Battery charging Alternator 24 volt withsuper enamelled/ paper coatedcopper wire of existing gauge incluiding all connected insulating material such as separator etc, varnishing, replacement of carbon bushes including disconnection/dismantling of electrical connections, foundation bolts, pulling out and reinsulation of burnt out winding after rewinding work including re-assembling and testingcomplete all as directed. |
| 78 | All as per ser item No 77 here-in-before but Cap of DG Set320 KVA |
| 79 | All as per ser item No 77 here-in-before but Cap of DG Set180/160 KVA |
| 80 | All as per ser item No 77 here-in-before but Cap of DG Set70/62.5 KVA |
| 81 | All as per ser item No 77 here-in-before but Cap of DG Set40/35 KVA |
| 82 | All as per ser item No 77 here-in-before but Cap of DG Set30/25 KVA |
| 83 | Supply and fixing battery lead with stranded copper conductor of size 95/70 sqmm single core PVC insulated flexible 0.6 M long along with battery terminal for positive and stator terminal duly soldered all as directed. |
| 84 | Supply and fixing in replacement of battery lead with stranded copper conductor of size 95/70 sqmm single core PVC insulated flexible 0.6 M long along with battery terminal for negative and stator terminal duly soldered all as directed. |
| 85 | M&L in repair rewiring of DG control panel of160 to 180 KVA DG Set as per existing circuitwith proper size of lugs complete all as specifiedand as directed |
| 86 | M&L in repair rewiring of DG control panel of40 to 70 KVA DG Set as per existing circuitwith proper size of lugs complete all as specifiedand as directed |
| 87 | Supply and fixing SMPS electronic battery charger 24 v, 10 amps complete with all connecting accessories and connecting wire all as specified and as directed. |
| 88 | Supply and fixing SMPS electronic battery charger 12 v, 10 amps complete with all connecting accessories and connecting wire all as specified and as directed. |
| 89 | Supply and fixing oil temp sensor suitable for DG setof cap 750 KVAcomplete all as specified and directed at site. |
| 90 | All as per ser item No 89 here-in-before but Cap of DG Set320 KVA |
| 91 | All as per ser item No 89 here-in-before but Cap of DG Set180/160 KVA |
| 92 | All as per ser item No 89 here-in-before but Cap of DG Set70/62.5 KVA |
| 93 | All as per ser item No 89 here-in-before but Cap of DG Set45/40/35 KVA |
| 94 | Supply and fix in replacement AVR suitable for 750 KVADG Set complete complete all as specified and directed. |
| 95 | All as per ser item No 94 here-in-before but Cap of DG Set320 KVA |
| 96 | All as per ser item No 94 here-in-before but Cap of DG Set180/160 KVA |
| 97 | All as per ser item No 94 here-in-before but Cap of DG Set70/62.5 KVA |
| 98 | All as per ser item No 94 here-in-before but Cap of DG Set45/40/35 KVA |
| 99 | M&L in replacement diesel pipe metal mesh types both side connecting arrangement of length as required on sitesuitable for 750 KVA DG Set complete all as specified and directed. |
| 100 | All as per ser item No 99 here-in-before but Cap of DG Set320 KVA |
| 101 | All as per ser item No 99 here-in-before but Cap of DG Set180/160 KVA |
| 102 | All as per ser item No 99 here-in-before but Cap of DG Set70/62.5 KVA |
| 103 | All as per ser item No 99 here-in-before but Cap of DG Set45/40/35 KVA |
| 104 | Supply and fixing in repair actuator suitable for DG set of capacity 750 KVA complete all as specified and directed at site. |
| 105 | All as per ser item No 104 here-in-before but Cap of DG Set320 KVA |
| 106 | All as per ser item No 104 here-in-before but Cap of DG Set180/160 KVA |
| 107 | All as per ser item No 104 here-in-before but Cap of DG Set70/62.5 KVA |
| 108 | Supply and fix in replacementof RRAsuitable for 750 KVADG Set complete complete all as specified and directed. |
| 109 | All as per ser item No 108 here-in-before but Cap of DG Set320 KVA |
| 110 | All as per ser item No 108 here-in-before but Cap of DG Set180/160 KVA |
| 111 | All as per ser item No 108 here-in-before but Cap of DG Set70/62.5 KVA |
| 112 | All as per ser item No 108 here-in-before but Cap of DG Set45/40/35 KVA |
| 113 | M&L for checking/Inspection/Maintenance and servicing complete including replacement ofunserviceable spare parts ofthe DG Set( comparising of Engine/Alternator/Control panel)of the 180/160 KVADG Set for smooth functioningas per OEMinstructions including replacement of alltype of gasket, all type ofbelt,door repair with sound proof spunch andor all as directedby Engr-in-Charge Checking (a) Checking& replacement oflubricating oil,(b) Repair & Replacementofall the nut,bolts of engine and alternator(c) Replacement of all beltsand adjustthe tension properly(d)and dismantling the cylinder head andassemblyfrom DG Set, including overhauling of Engine and head shifting to authorised workshop for head & valve polishingandback forcarrying outfollowing repair and replacement of spares as mentioned below :-Note : (i) Spare parts to be measured andpaid and separately |
| 114 | Kit cylinder Liner |
| 115 | Liner o ring |
| 116 | Piston |
| 117 | Piston ring |
| 118 | C.R.bearing |
| 119 | Valve |
| 120 | Complet gasket ofDG Set |
| 121 | Complete fan belt of Dg Set |
| 122 | Valve Guide |
| 123 | Valve seat inlet |
| 124 | Valve seat exhaust |
| 125 | valve seal |
| 126 | Kit Turbo charging |
| 127 | Piston cooling nozzle |
| 128 | Piston connecting rod |
| 129 | Gear assembly |
| 130 | Governor pressure valve (hydraulic Governor) |
| 131 | Collet valve |
| 132 | Spring valve |
| 133 | Collar thrust |
| 134 | Kit injector |
| 135 | Barrel sleeve |
| 136 | M&L for checking/Inspection/Maintenance and servicing complete including replacement ofunserviceable spare parts ofthe DG Set( comparising of Engine/Alternator/Control panel)of the 45/40/35 KVADG Set for smooth functioningas per OEMinstructions including replacement of alltype of gasket, all type ofbelt,door repair with sound proof spunch andor all as directedby Engr-in-Charge Checking (a) Checking& replacement oflubricating oil,(b) Repair & Replacementofall the nut,bolts of engine and alternator(c) Replacement of all beltsand adjustthe tension properly(d)and dismantling the cylinder head andassemblyfrom DG Set, including overhauling of Engine and head shifting to authorised workshop for head & valve polishingandback forcarrying outfollowing repair and replacement of spares as mentioned below :-Note : (i) Spare parts to be measured andpaid and separately |
| 137 | Kit cylinder Liner |
| 138 | Liner o ring |
| 139 | Piston |
| 140 | Piston ring |
| 141 | C.R.bearing |
| 142 | Valve |
| 143 | Complet gasket ofDG Set |
| 144 | Complete fan belt of Dg Set |
| 145 | Valve Guide |
| 146 | Valve seat inlet |
| 147 | Valve seat exhaust |
| 148 | valve seal |
| 149 | Kit Turbo charging |
| 150 | Piston cooling nozzle |
| 151 | Piston connecting rod |
| 152 | Gear assembly |
| 153 | Governor pressure valve (hydraulic Governor) |
| 154 | Collet valve |
| 155 | Spring valve |
| 156 | Collar thrust |
| 157 | Kit injector |
| 158 | Barrel sleeve |
| 159 | Supply and fix in replacement of bellow flexible suitable for 750 KVA DG Set set all as specified and directed at site. |
| 160 | Supply and fix in replacement of bellow flexible suitable for 160/180 KVA DG Set set all as specified and directed at site. |
| 161 | Supply and fix in replacement of bellow flexible suitable for 70/62.5 KVA DG Set set all as specified and directed at site. |
| 162 | Supply and fix in replacement of bellow flexible suitable for 45/40/35 KVA DG Set set all as specified and directed at site. |
| 163 | Supply and fix in replacement of radiator hose pipe set with hose clip suitable for 750 kVA DG set all as specified and directed at site. |
| 164 | Supply and fix in replacement of radiator hose pipe set with hose clip suitable for 320 kVA DG set all as specified and directed at site. |
| 165 | Supply and fix in replacement of radiator hose pipe set with hose clip suitable for 180/160 kVA DG set all as specified and directed at site. |
| 166 | Supply and fix in replacement of radiator hose pipe set with hose clip suitable for 70/62.5 kVA DG set all as specified and directed at site. |
| 167 | Supply and fix in replacement ofengine Fan blade suitable for 750 kVA DG set all as specified and directed at site. |
| 168 | Supply and fix in replacement ofengine Fan blade suitable for 320 kVA DG set all as specified and directed at site. |
| 169 | Supply and fix in replacement ofengine Fan blade suitable for 180/160 kVA DG set all as specified and directed at site. |
| 170 | Supply and fix in replacement ofthermostate valve suitable for 750 KVA DGSetcomplete all as specified and directed at site. |
| 171 | Supply and fix in replacement ofthermostate valve suitable for 320 KVA DGSetcomplete all as specified and directed at site. |
| 172 | Supply and fix in replacement ofthermostate valve suitable for 180/160 KVA DG Setcomplete all as specified and directed at site. |
| 173 | Supply and fix in replacement ofthermostate valve suitable for 70/62.5 KVA DGSetcomplete all as specified and directed at site. |
| 174 | Supply and fixingin replacement of maintenance free battery with initially charged of capacity 90/100 AH, 12 volt complete all as specified and directec at site. |
| 175 | Supply and fixingin replacement of maintenance free battery with initially charged of capacity 150 AH, 12 volt complete all as specified and directec at site. |
| 176 | Supply and fixingin replacement of maintenance free battery with initially charged of capacity 180 AH, 12 volt complete all as specified and directec at site. |
| 177 | Servicing of AMF panel ofDG Set 320 kVAby OEM i.e auth dealer of installed atAF Stn Chabua by cleaning the complete panel with suitable cleaning agennt,removing dust particles by using high speed blower and checking thecontroller relays,timer, contactors for proper functioning,replacing defective spare parts,replacement of defectivewires ofexixting size up to 2 mtr,tightening ofall connections and applying jelly on contractors complete all asspecified and directed by Engr-in-Charge Note : Spare parts required will be measured and paid separately as supply only but cost of small wire s shall be included in thequotated rates. |
| 178 | Supply AMF Relayprocom |
| 179 | Supplymode selector switch |
| 180 | Supply only battery charger 24 Volt |
| 181 | CT coils 5/100 |
| 182 | Servicing of AMF panel ofDG Set 180/160 kVAby OEM i.e auth dealer of installed atAF Stn Chabua by cleaning the complete panel with suitable cleaning agennt,removing dust particles by using high speed blower and checking thecontroller relays,timer, contactors for proper functioning,replacing defective spare parts,replacement of defectivewires ofexixting size up to 2 mtr,tightening ofall connections and applying jelly on contractors complete all asspecified and directed by Engr-in-Charge Note : Spare parts required will be measured and paid separately as supply only but cost of small wire s shall be included in thequotated rates. |
| 183 | Supply AMF Relayprocom |
| 184 | Supplymode selector switch |
| 185 | Supply only battery charger 24 Volt |
| 186 | CT coils 5/100 |
| 187 | Servicing of AMF panel ofDG Set 100 kVAby OEM i.e auth dealer of installed atAF Stn Chabua by cleaning the complete panel with suitable cleaning agennt,removing dust particles by using high speed blower and checking thecontroller relays,timer, contactors for proper functioning,replacing defective spare parts,replacement of defectivewires ofexixting size up to 2 mtr,tightening ofall connections and applying jelly on contractors complete all asspecified and directed by Engr-in-Charge Note : Spare parts required will be measured and paid separately as supply only but cost of small wire s shall be included in thequotated rates. |
| 188 | Supply AMF Relayprocom |
| 189 | Supplymode selector switch |
| 190 | Supply only battery charger 24 Volt |
| 191 | CT coils 5/100 |
| 192 | Servicing of AMF panel ofDG Set 62.5 kVAby OEM i.e auth dealer of installed atAF Stn Chabua by cleaning the complete panel with suitable cleaning agennt,removing dust particles by using high speed blower and checking thecontroller relays,timer, contactors for proper functioning,replacing defective spare parts,replacement of defectivewires ofexixting size up to 2 mtr,tightening ofall connections and applying jelly on contractors complete all asspecified and directed by Engr-in-Charge Note : Spare parts required will be measured and paid separately as supply only but cost of small wire s shall be included in thequotated rates. |
| 193 | Supply AMF Relayprocom |
| 194 | Supplymode selector switch |
| 195 | Supply only battery charger 24 Volt |
| 196 | CT coils 5/100 |
| 197 | Supply and fix in replacement of radiatorCooling Fanpulley suitable for 750 kVA DG Set complete all as specified and directed at site. |
| 198 | Supply and fix in replacement of radiatorCooling Fanpulley suitable for 180/160 KVA DG Set complete all as specified and directed at site. |
| 199 | Supply and fix in replacement of enginemounting vibrating padsuitable for DG Set cap 180/160KVAcomplete all as specified and directed at site. |
| 200 | Supply and fix in replacement of enginemounting vibrating padsuitable for DG Set cap 70/62.5 KVA complete all as specified and directed at site. |
| 201 | Supply and fixing in repair of 4 pole MCCB400 Amp suitable for 160/180 KVA DG Set AMF Panels complete all as specified and directed at site. |
| 202 | Supply and fixing in repair of 4 pole MCCB300 Amp suitable for 160/180 KVA DG Set AMF Panels complete all as specified and directed at site. |
| 203 | Supply and fixing in repair of 4 pole power contactors,suitable for 160/180 KVA DG Set AMF Panels complete all as specified and directed at site. |
| 204 | S & F in replacement of all type of \"V\" beltsuitable for 70/62.5 kVA DG Setcomplete all as directed by Engr-in -charge. |
| 205 | S & F in replacement of all type of \"V\" beltsuitable for 180/160 kVA DG Setcomplete all as directed by Engr-in -charge. |
| 206 | Supply and fix in replacement ofall type of gasket / seal suitable for 125/100 kVA DG set all as specified and directed at site. |
| 207 | Supply and fixing in repair contactorsuitablefor62.5 kVADG Set AMF Panel complete all as specified and directed at site. |
| 208 | Supply and fixing in repair contactor coil suitable for62.5 kVADG Set AMF Panel complete all as specified and directed at site. |
| 209 | Supply and fix in replacement of Turbo charger suitable for 160/180 KVA Generator set of any ,make and type complete all as per specified and directed at site. |
| 210 | Supply and fixin replacement ofwater pump assembly suitable for existing DG set of capacity 70/62.5 KVcomplete all as specified and directed at site. |
| 211 | Supply and fix in replacement offour pole change over switch with advance neutral on loadI-O-II, current rating 630 amps ,415 voltswith open execution/ with enclosure complete all as specified and directed at site. |
| 212 | Supply and fix in replacement offour pole change over switch with advance neutral on loadI-O-II, current rating 400 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site. |
| 213 | Supply and fix in replacement offour pole change over switch with advance neutral on loadI-O-II, current rating 320/315 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site. |
| 214 | Supply and fix in replacement offour pole change over switch with advance neutral on loadI-O-II, current rating 250 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site. |
| 215 | Supply and fix in replacement offour pole change over switch with advance neutral on loadI-O-II, current rating 200 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site. |
| 216 | Supply and fix in replacement offour pole change over switch with advance neutral on loadI-O-II, current rating 160 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site. |
| 217 | Supply and fix in replacement offour pole change over switch with advance neutral on loadI-O-II, current rating 125 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site. |
| 218 | Supply and fix in replacement offour pole change over switch with advance neutral on loadI-O-II, current rating 63 amps ,415 volts with open execution / with enclosure complete all as specified and directed at site. |
| 219 | Supply andfix in replacement of engine control panel considting of ignition switch,water temperature gauge,VAF meter,push button,indication lamp etc suitable forDG set of capacity62.5 KVAcompleteall as specified and directec at site |
| 220 | S & F in repair doors of 250 kVA DG Setincluding welding of defective portion and provision of fixing of new MS hinges/MS sheetof suitable size includingreplacement ofall doors acoustic foamcomplete all as directed by Engr-in -charge. |
| 221 | S & F in repair doors of 180/160 kVA DG Setincluding welding of defective portion and provision of fixing of new MS hinges/MS sheetof suitable size includingreplacement ofall doors acoustic foamcomplete all as directed by Engr-in -charge. |
| 222 | S & F in repair doors of 70/62.5 kVA DG Setincluding welding of defective portion and provision of fixing of new MS hinges/MS sheetof suitable size includingreplacement ofall doors acoustic foamcomplete all as directed by Engr-in -charge. |
| 223 | S & F in repair doors of 45/40 kVA DG Setincluding welding of defective portion and provision of fixing of new MS hinges/MS sheetof suitable size includingreplacement ofall doors acoustic foamcomplete all as directed by Engr-in -charge. |