| 1 | M&L for XLPE insulated, armoured heavyduty electric cable with aluminium conductor, 3.5 core ,1100voltsgrade, cross-sectional area 150 sq. mm. Make:Polycab/RR/KEI/Havells/Finolex |
| 2 | M&L for XLPE insulated, armoured heavyduty electric cable with aluminium conductor, 3.5 core ,1100 volts grade, cross-sectional area 95 sq.mm.Make:Polycab/RR/KEI/Havells/Finolex |
| 3 | M&L for XLPE insulated, armoured heavyduty electric cable with aluminium conductor, 3.5 core ,1100 volts grade , cross-sectional area50sq. mm.Make:Polycab/RR/KEI/Havells/Finolex |
| 4 | M&L for XLPE insulated, armoured heavyduty electric cable with aluminium conductor, 3.5 core ,1100 volts grade, cross-sectional area 35 sq. mm.Make:Polycab/RR/KEI/Havells/Finolex |
| 5 | M&L for XLPE insulated, armoured heavyduty electric cable with aluminium conductor, 4 core ,1100 volts grade, cross-sectional area 16sq. mm.Make:Polycab/RR/KEI/Havells/Finolex |
| 6 | M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 4 sq. mm,3core. Make:Polycab/RR/KEI/Havells/Finolex |
| 7 | Excavating in trenches, in hard dense soiln exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out. |
| 8 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in hard dense soil |
| 9 | M&L for sand filling under floor or in foundation including watering and consolidation |
| 10 | M&L Supplying and laying un- reinforced precast concrete cable cover, class LV, type 2,flat , size 300mm x 180mm x 40mm |
| 11 | Demolition ofCement Concrete un-reinforced of any description and in any position not otherwise specifically provided |
| 12 | M&L for Tubes, \"medium grade\"Bore of tube in 25mm galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors |
| 13 | M&L for Tubes, \"medium grade\"Bore of tube in 100mm galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors |
| 14 | M&L for Tubes, \"medium grade\"Bore of tube in 150mm galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors |
| 15 | M&L for Cement concrete in surface channels and drains Type B2 1:2:4 (40 mm graded aggregate) . |
| 16 | M&L Earthing complete with Copper earth plate electrode60×60cm ×3.15mm thick electrode andcopper strip as earthing lead, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to copper strip 20×3mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion . |
| 17 | M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion |
| 18 | S&Ffor GI pipes Heavy Class 25 mm Dia. |
| 19 | M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip. |
| 20 | Supply and fixing ofCI cover plate0.3.x0.3M with hinges and frame for earth pit chamber . |
| 21 | S& F G I funnel with wire meshwith 25mm G I socket. |
| 22 | Supply ,Instasllation & commissioning of LT Panel Adjustable type 3 pole MCCB incomer of capacity 400Aofcurrent rating withAluminium Bus Bar of cappacity 600A along with proper neutrallink having provision of street light control ciruit with 63A MCB & Timer and required civil work like;excavation , Grouting of long GI stand etc.(Specification Sheet Attached asAnnexure-D) |
| 23 | Supply ,Instasllation & commissioning of LT Panel having Adjustable type 3 pole MCCB incomer of capacity 160Aofcurrent rating withAluminium Bus Bar of cappacity 200A along with proper neutrallink and required civil work like;excavation , Grouting of long GI stand etc(Specification Sheet Attached asAnnexure-D) |
| 24 | Supply ,Instasllation & commissioning of LT Panel having Adjustable type 3 pole MCCB incomer of capacity 125Aofcurrent rating withAluminium Bus Bar of cappacity 200A along with proper neutrallink and required civil work like;excavation , Grouting of long GI stand etc(Specification Sheet Attached asAnnexure-D) |
| 25 | M&L for Raod boring of diameter 250mmbelow1.0m from ground levelwith required accessories. |
| 26 | Supply & fixing of Outdoor type 3 phase with neutral link , 8 way DB Bus barfor street light Cabling connection along with required civil work like; hole in pole,welding etc. |