Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Construction of Drivers Accommodation at Bolgatty Palace and Island Resort, Kochi-Portable Prefabricated container dormitory-General Civil Work |
| 2 | Providing and installing factory-moulded, double-layer PVC bathroom block made from single-piece LLDPE (Linear Low-Density Polyethylene) construction, with anoverall size of 1.2m (length) x 0.95m (width) x 2.0m height). The unit shall have a minimum wall thickness of 8mm and a floor and projection thickness between 11mm to 13mm, ensuring adequate strength and durability. The bathroom block shall be supplied without any sanitary fittings, but shall include provisions for future installation of sanitary fixtures such as water inlet and outlet points and basic internal plumbing routes. The unit shall be delivered in fully assembled or knock-down condition as per manufacturer?s standards. The rate shall include the cost of all materials, labour, transportation, handling, and installation, complete in all respects and ready for further fixture installation |
| 3 | Providing and installing factory-moulded, double-layer PVC toilet block made from single-piece LLDPE (Linear Low-Density Polyethylene) construction, having an overall size of 1.2m (length) x 0.95m (width) x 2.0m (height). The unit shall have a minimum wall thickness of 8mm and a floor and projection thickness ranging between 11mm to 13mm for added durability and structural integrity. The toilet block shall be equipped with a European Water Closet (EWC) with a dual flush tank of Simpolo or equivalent approved brand, along with a wall-mounted wash basin of Simpolo or equivalent make. A single tap fitting of Runs brand or any other ISI-marked equivalent shall be provided. The unit shall include all necessary internal plumbing connections for water inlet and outlet, including drainage provisions. The rate shall include the supply of all materials, labour, transportation, handling, installation, and necessaryaccessories to ensure the toilet block is fully functional and ready for use |
| 4 | Supply of two tier cot size-6 x 2.5 x 5 feet height with bed |
| 5 | Supply of prefabricated portable container cabin constructed using 30mm thick PUFF insulated sandwich panels for walls and roof. The sandwich panels shall consist of 0.35mm thick Galvalume PPGL sheets (Brand: Jindal Kingspan) on both sides with expanded polyurethane foam as core insulation. The main structural frame shall be fabricated using galvanized rectangular tubes of size 75 x 40 x 2mm for the base,verticals, and top frame. Floor and roof grids shall be made of 60 x 40mm and 40 x 40mm galvanized rectangular pipes (16 gauge) with a grid spacing not exceeding 600 x 600mm. Flooring to consist of 15mm thick heavy-duty cement board with 1mm thick anti-skid vinyl finish. Roofing shall also be made from 30mm insulated sandwich panels matching the wall specifications. All structural steel shall be painted with one coat of primer and two coats of synthetic enamel paint. Electrical system to include 2 nos. LED tube lights, 4 nos. 5A plug points, 1 no. 15A plug point for AC, and 2 nos. branded wall-mounted fans, complete with internal wiring through PVC casing and a distribution board with MCBs. The unit shall be provided with 3 nos. aluminiumsliding windows (size: 1.0m x 1.0m), 1 no. 30mm thick insulated sandwich panel door, and false ceiling made from PVC sections. Complete cabin to be thermally and acoustically insulated, fully finished and ready to use |
| 6 | Supply and installation of uPVC Manhole Unit,| Factory-made 450 mm dia, 600–900 mm depth, with cover & frame (United or equivalent), uPVCinspection chamber suitable for the inlet and outlet connections. It shall be lightweight, leakproof, and corrosion-resistant, made from high-grade UV-stabilized uPVC conforming to IS 14735:1999. The internal diameter shall be 450 mm with a depth of600–900 mm, and the base shall have smooth flow channels with 110 mm inlet and outlet connections sealed with rubber gaskets. A lockable, non-slip uPVC cover and frame with a clear opening of 450 mm and a minimum 2.5-ton load capacity shall be provided. Installation shall include a 150 mm sand or PCC bedding, proper backfilling, and testing for leak proofness before commissioning. |
| 7 | Supply and installation of septic tank shall be of factory-made, high-quality uPVCconstruction, supplied by United Septic Tank or an equivalent approved make. It shall be designed for a 50-flush capacity, with a minimum total volume of 2000 liters, suitable for treating domestic wastewater as per IS 2470 (Part 1):1985 standards. The tank shall be lightweight, leakproof, corrosion-resistant, and durable, manufacturedusing UV-stabilized, high-grade unplasticized polyvinyl chloride (uPVC) material. It shall consist of two compartments with properly designed internal baffle walls to ensure efficient sedimentation and digestion of waste. The unit shall be provided with a minimum 110 mm inlet and outlet connection, along with a 50 mm diameter vent pipe fitted with a protective cowl for safe gas release. A manhole cover of at least 450 mm diameter shall be provided for easy inspection and cleaning. The design shall incorporate integral ribbing or structural reinforcement to withstand underground soil and hydrostatic loads when installed at a depth of up to 1.5 meters. Installation shall include a 150 mm thick sand bedding at the base, with proper backfilling and compaction around the tank. The entire system shall be hydro-tested for leakage prior to commissioning, ensuring long-term, trouble-free performance with a design life of 25 years or more |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 10 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 11 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal dia pipes |
| 12 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 13 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 14 | Construction of Drivers Room in KTDC Golden Peak, Ponmudi.-General Civil Work |
| 15 | Providing and installing factory-moulded, double-layer PVC bathroom block made from single-piece LLDPE (Linear Low-Density Polyethylene) construction, with anoverall size of 1.2m (length) x 0.95m (width) x 2.0m height). The unit shall have a minimum wall thickness of 8mm and a floor and projection thickness between 11mm to 13mm, ensuring adequate strength and durability. The bathroom block shall be supplied without any sanitary fittings, but shall include provisions for future installation of sanitary fixtures such as water inlet and outlet points and basic internal plumbing routes. The unit shall be delivered in fully assembled or knock-down condition as per manufacturer?s standards. The rate shall include the cost of all materials, labour, transportation, handling, and installation, complete in all respects and ready for further fixture installation |
| 16 | Providing and installing factory-moulded, double-layer PVC toilet block made from single-piece LLDPE (Linear Low-Density Polyethylene) construction, having an overall size of 1.2m (length) x 0.95m (width) x 2.0m (height). The unit shall have a minimum wall thickness of 8mm and a floor and projection thickness ranging between 11mm to 13mm for added durability and structural integrity. The toilet block shall be equipped with a European Water Closet (EWC) with a dual flush tank of Simpolo or equivalent approved brand, along with a wall-mounted wash basin of Simpolo or equivalent make. A single tap fitting of Runs brand or any other ISI-marked equivalent shall be provided. The unit shall include all necessary internal plumbing connections for water inlet and outlet, including drainage provisions. The rate shall include the supply of all materials, labour, transportation, handling, installation, and necessaryaccessories to ensure the toilet block is fully functional and ready for use |
| 17 | Supply of two tier cot size-6 x 2.5 x 5 feet height with bed |
| 18 | Supply of prefabricated portable container cabin constructed using 30mm thick PUFF insulated sandwich panels for walls and roof. The sandwich panels shall consist of 0.35mm thick Galvalume PPGL sheets (Brand: Jindal Kingspan) on both sides with expanded polyurethane foam as core insulation. The main structural frame shall be fabricated using galvanized rectangular tubes of size 75 x 40 x 2mm for the base,verticals, and top frame. Floor and roof grids shall be made of 60 x 40mm and 40 x 40mm galvanized rectangular pipes (16 gauge) with a grid spacing not exceeding 600 x 600mm. Flooring to consist of 15mm thick heavy-duty cement board with 1mm thick anti-skid vinyl finish. Roofing shall also be made from 30mm insulated sandwich panels matching the wall specifications. All structural steel shall be painted with one coat of primer and two coats of synthetic enamel paint. Electrical system to include 2 nos. LED tube lights, 4 nos. 5A plug points, 1 no. 15A plug point for AC, and 2 nos. branded wall-mounted fans, complete with internal wiring through PVC casing and a distribution board with MCBs. The unit shall be provided with 3 nos. aluminiumsliding windows (size: 1.0m x 1.0m), 1 no. 30mm thick insulated sandwich panel door, and false ceiling made from PVC sections. Complete cabin to be thermally and acoustically insulated, fully finished and ready to use |
| 19 | Supply and installation of uPVC Manhole Unit,| Factory-made 450 mm dia, 600–900 mm depth, with cover & frame (United or equivalent), uPVCinspection chamber suitable for the inlet and outlet connections. It shall be lightweight, leakproof, and corrosion-resistant, made from high-grade UV-stabilized uPVC conforming to IS 14735:1999. The internal diameter shall be 450 mm with a depth of600–900 mm, and the base shall have smooth flow channels with 110 mm inlet and outlet connections sealed with rubber gaskets. A lockable, non-slip uPVC cover and frame with a clear opening of 450 mm and a minimum 2.5-ton load capacity shall be provided. Installation shall include a 150 mm sand or PCC bedding, proper backfilling, and testing for leak proofness before commissioning. |
| 20 | Supply and installation of septic tank shall be of factory-made, high-quality uPVCconstruction, supplied by United Septic Tank or an equivalent approved make. It shall be designed for a 50-flush capacity, with a minimum total volume of 2000 liters, suitable for treating domestic wastewater as per IS 2470 (Part 1):1985 standards. The tank shall be lightweight, leakproof, corrosion-resistant, and durable, manufacturedusing UV-stabilized, high-grade unplasticized polyvinyl chloride (uPVC) material. It shall consist of two compartments with properly designed internal baffle walls to ensure efficient sedimentation and digestion of waste. The unit shall be provided with a minimum 110 mm inlet and outlet connection, along with a 50 mm diameter vent pipe fitted with a protective cowl for safe gas release. A manhole cover of at least 450 mm diameter shall be provided for easy inspection and cleaning. The design shall incorporate integral ribbing or structural reinforcement to withstand underground soil and hydrostatic loads when installed at a depth of up to 1.5 meters. Installation shall include a 150 mm thick sand bedding at the base, with proper backfilling and compaction around the tank. The entire system shall be hydro-tested for leakage prior to commissioning, ensuring long-term, trouble-free performance with a design life of 25 years or more |
| 21 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 23 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 24 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal dia pipes |
| 25 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 26 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 27 | Drivers Accommodation_Kumarakom Gateway Resort, Thanneermukkom -Portable Puff Panel container-General Civil Work |
| 28 | Providing and installing factory-moulded, double-layer PVC bathroom block made from single-piece LLDPE (Linear Low-Density Polyethylene) construction, with anoverall size of 1.2m (length) x 0.95m (width) x 2.0m height). The unit shall have a minimum wall thickness of 8mm and a floor and projection thickness between 11mm to 13mm, ensuring adequate strength and durability. The bathroom block shall be supplied without any sanitary fittings, but shall include provisions for future installation of sanitary fixtures such as water inlet and outlet points and basic internal plumbing routes. The unit shall be delivered in fully assembled or knock-down condition as per manufacturers standards. The rate shall include the cost of all materials, labour, transportation, handling, and installation, complete in all respects and ready for further fixture installation |
| 29 | Providing and installing factory-moulded, double-layer PVC toilet block made from single-piece LLDPE (Linear Low-Density Polyethylene) construction, having an overall size of 1.2m (length) x 0.95m (width) x 2.0m (height). The unit shall have a minimum wall thickness of 8mm and a floor and projection thickness ranging between 11mm to 13mm for added durability and structural integrity. The toilet block shall be equipped with a European Water Closet (EWC) with a dual flush tank of Simpolo or equivalent approved brand, along with a wall-mounted wash basin of Simpolo or equivalent make. A single tap fitting of Runs brand or any other ISI-marked equivalent shall be provided. The unit shall include all necessary internal plumbing connections for water inlet and outlet, including drainage provisions. The rate shall include the supply of all materials, labour, transportation, handling, installation, and necessaryaccessories to ensure the toilet block is fully functional and ready for use |
| 30 | Supply of two tier cot size-6 x 2.5 x 5 feet height with bed |
| 31 | Supply of prefabricated portable container cabin constructed using 30mm thick PUFF insulated sandwich panels for walls and roof. The sandwich panels shall consist of 0.35mm thick Galvalume PPGL sheets (Brand: Jindal Kingspan) on both sides with expanded polyurethane foam as core insulation. The main structural frame shall be fabricated using galvanized rectangular tubes of size 75 x 40 x 2mm for the base,verticals, and top frame. Floor and roof grids shall be made of 60 x 40mm and 40 x 40mm galvanized rectangular pipes (16 gauge) with a grid spacing not exceeding 600 x 600mm. Flooring to consist of 15mm thick heavy-duty cement board with 1mm thick anti-skid vinyl finish. Roofing shall also be made from 30mm insulated sandwich panels matching the wall specifications. All structural steel shall be painted with one coat of primer and two coats of synthetic enamel paint. Electrical system to include 2 nos. LED tube lights, 4 nos. 5A plug points, 1 no. 15A plug point for AC, and 2 nos. branded wall-mounted fans, complete with internal wiring through PVC casing and a distribution board with MCBs. The unit shall be provided with 3 nos. aluminiumsliding windows (size: 1.0m x 1.0m), 1 no. 30mm thick insulated sandwich panel door, and false ceiling made from PVC sections. Complete cabin to be thermally and acoustically insulated, fully finished and ready to use |
| 32 | Supply and installation of uPVC Manhole Unit,| Factory-made 450 mm dia, 600–900 mm depth, with cover & frame (United or equivalent), uPVCinspection chamber suitable for the inlet and outlet connections. It shall be lightweight, leakproof, and corrosion-resistant, made from high-grade UV-stabilized uPVC conforming to IS 14735:1999. The internal diameter shall be 450 mm with a depth of600–900 mm, and the base shall have smooth flow channels with 110 mm inlet and outlet connections sealed with rubber gaskets. A lockable, non-slip uPVC cover and frame with a clear opening of 450 mm and a minimum 2.5-ton load capacity shall be provided. Installation shall include a 150 mm sand or PCC bedding, proper backfilling, and testing for leak proofness before commissioning. |
| 33 | Supply and installation of septic tank shall be of factory-made, high-quality uPVCconstruction, supplied by United Septic Tank or an equivalent approved make. It shall be designed for a 50-flush capacity, with a minimum total volume of 2000 liters, suitable for treating domestic wastewater as per IS 2470 (Part 1):1985 standards. The tank shall be lightweight, leakproof, corrosion-resistant, and durable, manufacturedusing UV-stabilized, high-grade unplasticized polyvinyl chloride (uPVC) material. It shall consist of two compartments with properly designed internal baffle walls to ensure efficient sedimentation and digestion of waste. The unit shall be provided with a minimum 110 mm inlet and outlet connection, along with a 50 mm diameter vent pipe fitted with a protective cowl for safe gas release. A manhole cover of at least 450 mm diameter shall be provided for easy inspection and cleaning. The design shall incorporate integral ribbing or structural reinforcement to withstand underground soil and hydrostatic loads when installed at a depth of up to 1.5 meters. Installation shall include a 150 mm thick sand bedding at the base, with proper backfilling and compaction around the tank. The entire system shall be hydro-tested for leakage prior to commissioning, ensuring long-term, trouble-free performance with a design life of 25 years or more |
| 34 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 35 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 36 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 37 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal dia pipes |
| 38 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 39 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 40 | Construction of Drivers Room in KTDC Hotel Samudra Kovalam.-General Civil Work |
| 41 | Providing and installing factory-moulded, double-layer PVC bathroom block made from single-piece LLDPE (Linear Low-Density Polyethylene) construction, with anoverall size of 1.2m (length) x 0.95m (width) x 2.0m height). The unit shall have a minimum wall thickness of 8mm and a floor and projection thickness between 11mm to 13mm, ensuring adequate strength and durability. The bathroom block shall be supplied without any sanitary fittings, but shall include provisions for future installation of sanitary fixtures such as water inlet and outlet points and basic internal plumbing routes. The unit shall be delivered in fully assembled or knock-down condition as per manufacturers standards. The rate shall include the cost of all materials, labour, transportation, handling, and installation, complete in all respects and ready for further fixture installation |
| 42 | Providing and installing factory-moulded, double-layer PVC toilet block made from single-piece LLDPE (Linear Low-Density Polyethylene) construction, having an overall size of 1.2m (length) x 0.95m (width) x 2.0m (height). The unit shall have a minimum wall thickness of 8mm and a floor and projection thickness ranging between 11mm to 13mm for added durability and structural integrity. The toilet block shall be equipped with a European Water Closet (EWC) with a dual flush tank of Simpolo or equivalent approved brand, along with a wall-mounted wash basin of Simpolo or equivalent make. A single tap fitting of Runs brand or any other ISI-marked equivalent shall be provided. The unit shall include all necessary internal plumbing connections for water inlet and outlet, including drainage provisions. The rate shall include the supply of all materials, labour, transportation, handling, installation, and necessaryaccessories to ensure the toilet block is fully functional and ready for use |
| 43 | Supply of two tier cot size-6 x 2.5 x 5 feet height with bed |
| 44 | Supply of prefabricated portable container cabin constructed using 30mm thick PUFF insulated sandwich panels for walls and roof. The sandwich panels shall consist of 0.35mm thick Galvalume PPGL sheets (Brand: Jindal Kingspan) on both sides with expanded polyurethane foam as core insulation. The main structural frame shall be fabricated using galvanized rectangular tubes of size 75 x 40 x 2mm for the base,verticals, and top frame. Floor and roof grids shall be made of 60 x 40mm and 40 x 40mm galvanized rectangular pipes (16 gauge) with a grid spacing not exceeding 600 x 600mm. Flooring to consist of 15mm thick heavy-duty cement board with 1mm thick anti-skid vinyl finish. Roofing shall also be made from 30mm insulated sandwich panels matching the wall specifications. All structural steel shall be painted with one coat of primer and two coats of synthetic enamel paint. Electrical system to include 2 nos. LED tube lights, 4 nos. 5A plug points, 1 no. 15A plug point for AC, and 2 nos. branded wall-mounted fans, complete with internal wiring through PVC casing and a distribution board with MCBs. The unit shall be provided with 3 nos. aluminiumsliding windows (size: 1.0m x 1.0m), 1 no. 30mm thick insulated sandwich panel door, and false ceiling made from PVC sections. Complete cabin to be thermally and acoustically insulated, fully finished and ready to use |
| 45 | Supply and installation of uPVC Manhole Unit,| Factory-made 450 mm dia, 600–900 mm depth, with cover & frame (United or equivalent), uPVCinspection chamber suitable for the inlet and outlet connections. It shall be lightweight, leakproof, and corrosion-resistant, made from high-grade UV-stabilized uPVC conforming to IS 14735:1999. The internal diameter shall be 450 mm with a depth of600–900 mm, and the base shall have smooth flow channels with 110 mm inlet and outlet connections sealed with rubber gaskets. A lockable, non-slip uPVC cover and frame with a clear opening of 450 mm and a minimum 2.5-ton load capacity shall be provided. Installation shall include a 150 mm sand or PCC bedding, proper backfilling, and testing for leak proofness before commissioning. |
| 46 | Supply and installation of septic tank shall be of factory-made, high-quality uPVCconstruction, supplied by United Septic Tank or an equivalent approved make. It shall be designed for a 50-flush capacity, with a minimum total volume of 2000 liters, suitable for treating domestic wastewater as per IS 2470 (Part 1):1985 standards. The tank shall be lightweight, leakproof, corrosion-resistant, and durable, manufacturedusing UV-stabilized, high-grade unplasticized polyvinyl chloride (uPVC) material. It shall consist of two compartments with properly designed internal baffle walls to ensure efficient sedimentation and digestion of waste. The unit shall be provided with a minimum 110 mm inlet and outlet connection, along with a 50 mm diameter vent pipe fitted with a protective cowl for safe gas release. A manhole cover of at least 450 mm diameter shall be provided for easy inspection and cleaning. The design shall incorporate integral ribbing or structural reinforcement to withstand underground soil and hydrostatic loads when installed at a depth of up to 1.5 meters. Installation shall include a 150 mm thick sand bedding at the base, with proper backfilling and compaction around the tank. The entire system shall be hydro-tested for leakage prior to commissioning, ensuring long-term, trouble-free performance with a design life of 25 years or more |
| 47 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 48 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 49 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 50 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal dia pipes |
| 51 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 52 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 53 | Drivers Accomodation_Waterscapes Kumarakom-Portable container dormitory- General Civil Work |
| 54 | Providing and installing factory-moulded, double-layer PVC bathroom block made from single-piece LLDPE (Linear Low-Density Polyethylene) construction, with anoverall size of 1.2m (length) x 0.95m (width) x 2.0m height). The unit shall have a minimum wall thickness of 8mm and a floor and projection thickness between 11mm to 13mm, ensuring adequate strength and durability. The bathroom block shall be supplied without any sanitary fittings, but shall include provisions for future installation of sanitary fixtures such as water inlet and outlet points and basic internal plumbing routes. The unit shall be delivered in fully assembled or knock-down condition as per manufacturers standards. The rate shall include the cost of all materials, labour, transportation, handling, and installation, complete in all respects and ready for further fixture installation |
| 55 | Providing and installing factory-moulded, double-layer PVC toilet block made from single-piece LLDPE (Linear Low-Density Polyethylene) construction, having an overall size of 1.2m (length) x 0.95m (width) x 2.0m (height). The unit shall have a minimum wall thickness of 8mm and a floor and projection thickness ranging between 11mm to 13mm for added durability and structural integrity. The toilet block shall be equipped with a European Water Closet (EWC) with a dual flush tank of Simpolo or equivalent approved brand, along with a wall-mounted wash basin of Simpolo or equivalent make. A single tap fitting of Runs brand or any other ISI-marked equivalent shall be provided. The unit shall include all necessary internal plumbing connections for water inlet and outlet, including drainage provisions. The rate shall include the supply of all materials, labour, transportation, handling, installation, and necessaryaccessories to ensure the toilet block is fully functional and ready for use |
| 56 | Supply of two tier cot size-6 x 2.5 x 5 feet height with bed |
| 57 | Supply of prefabricated portable container cabin constructed using 30mm thick PUFF insulated sandwich panels for walls and roof. The sandwich panels shall consist of 0.35mm thick Galvalume PPGL sheets (Brand: Jindal Kingspan) on both sides with expanded polyurethane foam as core insulation. The main structural frame shall be fabricated using galvanized rectangular tubes of size 75 x 40 x 2mm for the base,verticals, and top frame. Floor and roof grids shall be made of 60 x 40mm and 40 x 40mm galvanized rectangular pipes (16 gauge) with a grid spacing not exceeding 600 x 600mm. Flooring to consist of 15mm thick heavy-duty cement board with 1mm thick anti-skid vinyl finish. Roofing shall also be made from 30mm insulated sandwich panels matching the wall specifications. All structural steel shall be painted with one coat of primer and two coats of synthetic enamel paint. Electrical system to include 2 nos. LED tube lights, 4 nos. 5A plug points, 1 no. 15A plug point for AC, and 2 nos. branded wall-mounted fans, complete with internal wiring through PVC casing and a distribution board with MCBs. The unit shall be provided with 3 nos. aluminiumsliding windows (size: 1.0m x 1.0m), 1 no. 30mm thick insulated sandwich panel door, and false ceiling made from PVC sections. Complete cabin to be thermally and acoustically insulated, fully finished and ready to use |
| 58 | Supply and installation of uPVC Manhole Unit,| Factory-made 450 mm dia, 600–900 mm depth, with cover & frame (United or equivalent), uPVCinspection chamber suitable for the inlet and outlet connections. It shall be lightweight, leakproof, and corrosion-resistant, made from high-grade UV-stabilized uPVC conforming to IS 14735:1999. The internal diameter shall be 450 mm with a depth of600–900 mm, and the base shall have smooth flow channels with 110 mm inlet and outlet connections sealed with rubber gaskets. A lockable, non-slip uPVC cover and frame with a clear opening of 450 mm and a minimum 2.5-ton load capacity shall be provided. Installation shall include a 150 mm sand or PCC bedding, proper backfilling, and testing for leak proofness before commissioning. |
| 59 | Supply and installation of septic tank shall be of factory-made, high-quality uPVCconstruction, supplied by United Septic Tank or an equivalent approved make. It shall be designed for a 50-flush capacity, with a minimum total volume of 2000 liters, suitable for treating domestic wastewater as per IS 2470 (Part 1):1985 standards. The tank shall be lightweight, leakproof, corrosion-resistant, and durable, manufacturedusing UV-stabilized, high-grade unplasticized polyvinyl chloride (uPVC) material. It shall consist of two compartments with properly designed internal baffle walls to ensure efficient sedimentation and digestion of waste. The unit shall be provided with a minimum 110 mm inlet and outlet connection, along with a 50 mm diameter vent pipe fitted with a protective cowl for safe gas release. A manhole cover of at least 450 mm diameter shall be provided for easy inspection and cleaning. The design shall incorporate integral ribbing or structural reinforcement to withstand underground soil and hydrostatic loads when installed at a depth of up to 1.5 meters. Installation shall include a 150 mm thick sand bedding at the base, with proper backfilling and compaction around the tank. The entire system shall be hydro-tested for leakage prior to commissioning, ensuring long-term, trouble-free performance with a design life of 25 years or more |
| 60 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 61 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 62 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 63 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge. Internal work - Exposed on wall20 mm nominal dia pipes |
| 64 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chased and making good the wall etc. 110 mm pipe 6kgf/cm2 |
| 65 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Please Enable Macros to View BoQ information |