| 1 | Item No.1:- Excavation for foundationin earth, soils of all types, sand, gravel, soft murum including shoring and strutting, dewatering as necessary and disposing off excavated stuff as directedetc. complete. |
| 2 | Item No. 02 Providing rubble filling of trap/granite /qurtzite/gneiss stone of approved quality in foundation including hand packing filling gravel of sand in the voids etc. complete.(Lead 50 m.) |
| 3 | Item No 03:- Providing and laying in situ M-20 cement concrete of trap / granite /quartzite / gneiss metal with 15% plum of trap stones for foundation and bedding of retaining walls and jetty etc. including necessary formwork, compacting, curing, bailing out water manually in tidal range etc. complete.. |
| 4 | ITEM NO.4 :- Providing and laying in situ M-25 cement concrete of trap / granite /quartzite / gneiss metal with 15% plum of trap stones for retaining walls and jetty etc. including necessary formwork, compacting, curing,bailing out water manually in tidal range etc. complete. |
| 5 | ITEM NO 5- :Providing and fixing in position Steel Bar ( TMT Bar ) reinforcement of various diameters for R.C.C. pile caps, footings, foundatiions, slabs, beams, columns, canopies, stircases, newels, chajjas, lintels, pardies, coping, fins, arches, etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking the bars, binding with wires or tack welding, and supporting as required complete. ( 5 Kms. Lead ). |
| 6 | Item No 6:- Providing laterite stone masonry in cement mortar 1:6 in superstructure including racking out joints when plastering is to be done/striking joints when no plastering is to be done watering and scaffolding. |
| 7 | Item No.7 Providing and casting in situ cement concrete M-20 for trap metal for R.C.C Beams and Lintels as per detailed drawings and designs or As directed by Engineer -In-Charges, including centering plywood/steel formworkcompacting roughening the surface if special finish is to be provided and curing complete. (Excluding steel reinforcement.) |
| 8 | Item No. 8 :- Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). |
| 9 | Item No.9 :- Providing and laying Cast insitu /Ready Mix cement concrete M-20 of trap /granite/quartzite/gneissmetal forR.C.C.slab sand landingsas per detailed design sand drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surfac e or roughening if special finishis to be provided and curing etc.complete,(Excluding reinforcement and structural steel). withfully automatic microprocessor based PLC with SCADA enabled reversible Drum Type mixer/concrete Batch mixplant (Panmixer) etc.complete.With fine aggregate (Crushed sand VSI Grade) |
| 10 | ITEM NO.10 : Providing sand face plaster externally in two coats using approved screened sand in all positions, including providing base coat of 15 mm thick in cement mortar 1:4 mixing approved water proofing compound at the rate of 1 kg/ 50 kg of cement and curing the same for not less than two days and keeping the surface of base coat roughtto receive the sand faced treatment 8 mm thick in cement mortar 1:4 and finishing the surface by taking out grains and curing for 14 days including preparing the surface, watering and scaffolding etc. complete. |
| 11 | ITEM NO.11 : Providinginternal cement plaster 12mm thick in a single coat, in cement mortar 1:3 with neeru finish to concrete or brick suface in all positions including racking out joints, scaffolding and curing complete. |
| 12 | ITEM NO.12 :Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. |
| 13 | ITEM NO.13- Providing and fixing board displaying information, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete. Spec. No. As directed by Engineer in Charge |