Tender For Improvement Of Electrical Installation & Fans At M.C. Pry School Aruna Nagar, Ward No. 83(Cspz)., Delhi-Delhi

Tender Notice

52148759
Tender For Improvement Of Electrical Installation & Fans At M.C. Pry School Aruna Nagar, Ward No. 83(Cspz).
Tender
Indian
Delhi
Delhi
12-11-2025

Tender Details

Tender For Improvement Of Electrical Installation & Fans At M.C. Pry School Aruna Nagar, Ward No. 83(Cspz).; 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.Group C 2 Rewiring for light point /fan point /exhaust fan point /call ball point with 1.5sq.mm FRLS PVC insulated copper conductor single core cableas earth wire in existing surface/recessed steel/ pvc conduit i/c dismentaling as reqd. etc as required.Group C 3 Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 4 (a) 200 mm X 300 mm X 100 mm deep 5 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessedPVC conduit as required. 6 (a)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 7 (b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 8 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (A) 6 Way Double door 9 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (A) 20 mm 10 Supplying and fixing 5amps,to 32 amps rating,240 volts, C curve miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc, as required. (A) Single Pole 11 Supply and fixing following rating, double pole, 240 volt, isolator in the existing MCB DB complete with connection, testing and commissioning etc. as required. (A) 40 amps 12 Laying of one number pvc insulated and PVC sheathed/ XLPE power cable of 1.1 kv grade of following sizein the existing surface as required 13 (A)Upto 35 sq. mm (clamped with 1mm thick saddle) 14 Laying of one number pvc insulated and PVC sheathed/ XLPE power cable of 1.1kv grade of following size abovein the existing masonry open duct as required. 15 (a)Upto 35 sqmm 16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 17 Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness ≥ 0.50 mm)(A) 18-22 W 18 Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F..0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000‹K / 4000‹K / 5700‹K /6000‹K/6500‹K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90‹C). 150Watt 19 Supply and fixing of following piano type swich/ socket on the existing switch box/ cover including connection etc as required. 20 (a)5/6amps switch 21 (b)15/16 amps switch 22 (c)3 pin 5/6 amps socket outlet 23 (d) 6 pin 15/16 amps socket outlet 24 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req.(a) 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) 25 Supply & Fixing of phenolic laminated 3 mm thick sheet i/c cutting as reqd. 26 Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holesin cubical panel making connection, etc as required 27 (a)100 Amp, 16KA TPMCCB 28 Supply of PVC/XLPE insulated PVC/XLPE sheathed Al. conductor armoured cable for working voltage up to 1.1 kv confirming to IS 7098(part-1) of following size 29 (a) 2 X6 sqmm 30 Supplying, lowering, testing and commissioning of vertical type, multistage, totally enclosed water filled deep well submersible pumping set complete i/c connection etc. as reqd a Single Phase 1.5 HP having discharge of 72 LPM Approx. at 49 M Head. 31 Supply, Installation, testing and commissioning of cubical type control panel board for single phase & Three Phasesubmersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc includingconnections etc as reqd. (a) 1.5 HP Singlephase

Key Value

Document Fees
INR 590 /-
Tender Value
INR 2.46 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail