}

Tender For Piling Works , Od245984/2025-2026:Boring, Providing And Installing Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-30 Of Specified Diameter And Length Below The Pile Cap To Carry A Safe Working Load Not Less Than Specified, Exclu, aluva-Kerala

Tender Notice

52147855
Tender For Piling Works , Od245984/2025-2026:Boring, Providing And Installing Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-30 Of Specified Diameter And Length Below The Pile Cap To Carry A Safe Working Load Not Less Than Specified, Exclu
Tender
Indian
Kerala
Aluva
13-11-2025

Tender Details

Tender For Piling Works , Od245984/2025-2026:Boring, Providing And Installing Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-30 Of Specified Diameter And Length Below The Pile Cap To Carry A Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Boring, With Bentonite Solution And Temporary Casing Of Appropriate Length For Setting Out And Removal Of Same And The Length Of The Pile To Be Embedded In The Pile Cap Etc. All Complete, Including Removal Of Excavated Earth With All Lifts And Leads (Length Of Pile For Payment Shall Be Measured Upto Bottom Of Pile Cap) (Note - No Extra Payment Will Be Paid For Excess Cement.) - 600 Mm Dia Piles , Od245983/2025-2026:Boring, Providing And Installing Bored Cast-In-Situ Reinforced Cement Concrete Piles Of Grade M-30 Of Specified Diameter And Length Below The Pile Cap To Carry A Safe Working Load Not Less Than Specified, Excluding The Cost Of Steel Reinforcement But Including The Cost Of Boring, With Bentonite Solution And Temporary Casing Of Appropriate Length For Setting Out And Removal Of Same And The Length Of The Pile To Be Embedded In The Pile Cap Etc. All Complete, Including Removal Of Excavated Earth With All Lifts And Leads (Length Of Pile For Payment Shall Be Measured Upto Bottom Of Pile Cap)((Note - No Extra Payment Will Be Paid For Excess Cement) ) - 500 Mm Dia Piles , 5.22.6:Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More , 20.6.1.1:Vertical Load Testing Of Piles In Accordance With Is 2911 (Part Iv) Including Installation Of Loading Platform By Kentledge/Anchor Piles Method And Preparation Of Pile Head Or Construction Of Test Cap And Dismantling Of Test Cap After Test Etc. Complete As Per Specification & The Direction Of Engineer In-Charge. Single Pile Upto 50 Tonne Capacityinitial Test (Test Load 2.5 Times The Safe Capacity) , 20.6.1.2:Vertical Load Testing Of Piles In Accordance With Is 2911 (Part Iv) Including Installation Of Loading Platform By Kentledge/Anchor Piles Method And Preparation Of Pile Head Or Construction Of Test Cap And Dismantling Of Test Cap After Test Etc. Complete As Per Specification & The Direction Of Engineer In-Charge.Single Pile Upto 50 Tonne Capacityroutine Test (Test Load 1.5 Times The Safe Capacity) , 20.9:Integrity Testing Of Pile Using Low Strain / Sonic Integrity Test/ Sonic Echo Test Method In Accordance With Is 14893 Including Surface Preparation Of Pile Top By Removing Soil, Mud, Dust & Chipping Lean Concrete Lumps Etc. And Use Of Computerised Equipment And High Skill Trained Personal For Conducting The Test & Submission Of Results, All Complete As Per Direction Of Engineer-In-Charge. Note:- The Inclusion Of The Above Item In The Schedule Of Work Shall Be Judiciously Decided By The Technical Sanctioning Authority, Keeping In View The Quality Control, Type Of Soil Strata & Importance Of The Project. , Building Civil Works , 2.8.1:Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil , 2.26.1:Extra For Every Additional Lift 1.5 M Or Part There Of In Excavation / Banking Excavated Or Stacked Materials.All Kinds Of Soil , 50.2.25.1:Filling With Contractors Own Earth ( Excluding Rock) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge , 50.2.26.1:Filling With Contractor Own Earth (Excluding Rock) In Open Areas In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M As Per Direction Of Site Engineer-In-Charge. , 4.1.8:Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 5.9.1:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Foundations, Footings, Bases Of Columns, Etc For Mass Concrete , 5.9.2:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Walls (Any Thickness) Including Attached Pilasters, Butteresses, Plinth And String Courses Etc. , 5.9.3:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.5:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers , 5.9.6:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Columns, Pillars, Piers, Abutments, Posts And Struts , 5.9.7:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Stairs, (Excluding Landings ) Except Spiral - Staircases) , Od344887/2025-2026:Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete - All Work Upto Plinth Level - Concrete Of M30 Grade With Minimum Cement Content Of 350 Kg/Cum (Note: No Extra Payment Shall Be Made For Excess Or Less Cement) , Od344888/2025-2026:Providing And Laying In Position Ready Mixed Or Site Batched Design Mix Cement Concrete For Reinforced Cement Concrete Work; Using Coarse Aggregate And Fine Aggregate Derived From Natural Sources, Portland Pozzolana / Ordinary Portland /Portland Slag Cement, Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate / Retard Setting Of Concrete, To Improve Durability And Workability Without Impairing Strength; Including Pumping Of Concrete To Site Of Laying, Curing, Carriage For All Leads; But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement As Per Direction Of The Engineer-In-Charge; For The Following Grades Of Concrete - All Work Above Plinth Level Upto Floor V Level - Concrete Of M30 Grade With Minimum Cement Content Of 350 Kg/Cum (Note: No Extra Payment Shall Be Made For Excess Or Less Cement) , Od245976/2025-2026:Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer - In-Charge. All Work Upto Plinth Level - Concrete Of M25 Grade With Minimum Cement Content Of 330 Kg /Cum (Note: No Extra Payment Shall Be Made For Excess Or Less Cement) , 5.22.6:Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More , 5.22A.6:Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More , 50.6.1.4:Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 30X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Foundation And Plinth With Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement : 6 Coarse Sand ) Etc Complete , 50.6.1.5:Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made) Of Size 30X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement : 6 Coarse Sand) Etc Complete , 50.6.1.6:Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 30X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Above Floor Two Level Upto Floor Five Level Thickness 20Cm And Above In : Cm 1:6 ( 1 Cement : 6 Coarse Sand Sand) Etc Complete , 50.6.3.2:Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made) Of Size 40X20x10 Cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level For 10 Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand) Including Cost Of Scaffolding Complete , Od381978/2025-2026:Solid Block Masonry Using Pre Cast Solid Blocks (Factory Made ) Of Size 40X20x10cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Above Floor Two Level Upto Floor Five Level For 10Cm Thick Wall In : Cm 1:6 ( 1 Cement : 6 Coarse Sand ) Including Cost Of Scaffolding Etc Complete , 4.11: Providing And Laying Damp-Proof Course 50Mm Thick With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand (Zone-Iii) Derived From Natural Sources : 4 Graded Stone Aggregate 20Mm Nominal Size Derived From Natural Sources). , 9.48.2:Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Openings/ Wooden Frames With Rawl Plugs Screws Etc , 9.117.2:Providing And Fixing Factory Made Upvc Door Frame Made Of Upvc Extruded Sections Having An Overall Dimension As Below (Tolerance ±1 Mm), With Wall Thickness 2.0Mm (±0.2 Mm), Corners Of The Door Frame To Be Jointed With Galvanized Brackets And Stainless Steel Screws, Joints Mitred And Plastic Welded. The Hinge Side Vertical Of The Frames Reinforced By Galvanized M.S. Tube Of Size 19 X 19 Mm And 1 Mm (± 0.1 Mm) Wall Thickness And 3 Nos. Stainless Steel Hinges Fixed To The Frame Complete As Per Manufacturers Specification And Direction Of Engineer-In-Chargeextruded Section Profile Size 42X50 Mm , 9.118.2:Providing And Fixing To Existing Door Frames30 Mm Thick Factory Made Polyvinyl Chloride (Pvc) Door Shutter Made Of Styles And Rails Of A Upvc Hollow Section Of Size 60X30 Mm And Wall Thickness 2 Mm (± 0.2 Mm), With Inbuilt Decorative Moulding Edging On One Side. The Styles And Rails Mitred And Joint At The Corners By Means Of M.S. Galvanised/Plastic Brackets Of Size 75X220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws. The Styles Of The Shutter Reinforced By Inserting Galvanised M.S. Tube Of Size 25X20 Mm And 1 Mm (± 0.1 Mm) Wall Thickness. The Lock Rail Made Up Of H Section, A Upvc Hollow Section Of Size 100X30 Mm And 2 Mm (± 0.2 Mm) Wall Thickness Fixed To The Shutter Styles By Means Of Plastic/Galvanised M.S. U Cleats. The Shutter Frame Filled With A Upvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm (± 0.1 Mm) Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Inserting Horizontally 6 Mm Galvanised M.S. Rod And Fastened With Nuts And Washers, Complete As Per Manufacturers Specification And Direction Of Engineer-In-Charge. , 9.147B.1:Providing And Fixing Factory Made Upvc White Colour Fixed Glazed Windows/Fixed Window / Ventilator Made Of (Small Series) Frame 47 X 50 Mm &Amp; Mullion 47 X 68 Mm Both Having Wall Thickness Of 1.9 &Plusmn; 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Upto 0.75 Sqm.) , 9.147A.2:Providing And Fixing Factory Made Upvc White Colour Casement/Casement Cum Fixed Glazed Windows Comprising Of Upvc Multi-Chambered Frame, Sash And Mullion (Where Ever Required) Extruded Profiles Duly Reinforced With 1.60 +/- 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length (Shape & Size According To Upvc Profile), Upvc Extruded Glazing Beads Of Appropriate Dimension, Epdm Gasket, Stainless Steel (Ss 304 Grade) Friction Hinges, Zinc Alloy (White Powder Coated) Casement Handles, G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Welded Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. (Single / Double Glass Panes And Silicon Sealant Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable.Casement Window Double Panels With S.S. Friction Hinges (300 X 19 X 1.9 Mm) Made Of (Small Series) Frame 47 X 50 Mm, Sash 47 X 68 Mm &Amp; Mullion 47 X 68 Mm All Having Wall Thickness Of 1.9 &Plusmn; 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Of Window Above 0.75 Sqm Upto 1.50 Sqm). , 9.147A.5:Providing And Fixing Factory Made Upvc White Colour Casement/Casement Cum Fixed Glazed Windows Comprising Of Upvc Multi-Chambered Frame, Sash And Mullion (Where Ever Required) Extruded Profiles Duly Reinforced With 1.60 +/- 0.2 Mm Thick Galvanized Mild Steel Section Made From Roll Forming Process Of Required Length (Shape & Size According To Upvc Profile), Upvc Extruded Glazing Beads Of Appropriate Dimension, Epdm Gasket, Stainless Steel (Ss 304 Grade) Friction Hinges, Zinc Alloy (White Powder Coated) Casement Handles, G.I Fasteners 100 X 8 Mm Size For Fixing Frame To Finished Wall, Plastic Packers, Plastic Caps And Necessary Stainless Steel Screws Etc. Profile Of Frame & Sash Shall Be Mitred Cut And Fusion Welded At All Corners, Mullion (If Required) Shall Be Also Fusion Welded Including Drilling Of Holes For Fixing Hardwares And Drainage Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. (Single / Double Glass Panes And Silicon Sealant Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable.Casement Window Double Panels With S.S. Friction Hinges (350 X 19 X 1.9 Mm) Made Of (Big Series)Frame 67 X 60 Mm &Amp; Sash / Mullion 67 X 80 Mm Both Having Wall Thickness Of 2.3 &Plusmn; 0.2 Mm And Single Glazing Bead/ Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 1.50 Sqm). , 21.3.2:Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 5.50 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , 50.9.1.1:Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length (Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately), Using Good Quality Anjili Wood /Jack Wood , 50.9.2.1:Providing And Fixing Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows, 35 Mm Thick Shutters Including Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineerin - Charge Using Anjili/ Jack Wood , 50.9.4.1:Providing And Fixing Paneling Or Paneling And Glazing In Paneled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows (Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured) Paneling For Paneled Or Paneled And Glazed Shutters 25 Mm To 40 Mm Thick Using Good Quality Anjili/ Jack Wood , 9.53:Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embeddings In Cement Concrete Block 30X10x15 Cm 1:3:6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size) , 9.88:Providing And Fixing Chromium Plated Brass 100 Mm Mortice Latch And Lock With 6 Levers And A Pair Of Lever Handles Of Approved Quality With Necessary Screws Etc. Complete. , 9.92.1:Providing And Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm , 9.97.3:Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised(Anodic Coating Not Less Than Grade Ac 10 As Per : 1868), Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Complete:200X10 Mm , 10.26.1:Providing And Fixing Hand Rail Of Approved Size By Welding Etc. To Steel Ladder Railing, Balcony Railing, Staircase Railing And Similar Works, Including Applying Priming Coat Of Approves Steel Primer.M.S. Tube , 13.21:Extra For Providing And Mixing Water Proofing Material In Cement Plaster Work In Proportion Recommended By The Manufacturers. , 13.1.1:12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) , 13.16.1:6 Mm Cement Plaster Of Mix:1:3 ( 1 Cement : 3 Fine Sand) , 13.9.1:Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand) Finished With A Floating Coat Of Neat Cement.12 Mm Cement Plaster , Od379233/2025-2026:Supplying And Filling With Cinder Under, Ramming Consolidating And Dressing Complete Including All Cost Of Materials, Labour Charges, Etc Complete , 22.5:Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A) First Layer Of Slurry Of Cement @ 0.488 Kg/Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg/Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B) Second Layer Of Slurry Of Cement @ 0.242 Kg /Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg/ Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. , 13.43.1:Applying One Coat Of Water Thinnable Cement Primer Of Approved Brand And Manufacture On Wall Surface:Water Thinnable Cement Primer , 13.83.2:Wall Painting With Premium Acrylic Emulsion Paint Of Interior Grade, Having Voc (Volatile Including Applying Additional Coats Wherever Required To Achieve Even Shade And Colour.Two Coats , 13.46.1:Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) , 13.85.1:Applying Priming Coats With Primer Of Approved Brand And Manufacture, Having Low Voc ( Volatile Organic Compound) Content.With Ready Mixed Pink Or Grey Primer On Wood Work (Hard And Soft Wood ) Having Voc Content Less Than 50 Grams/ Litre , Od245977/2025-2026:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade -Two Or More Coats On New Work , 22.23.1:Providing And Applying Integral Crystalline Slurry Of Hydrophilic In Nature For Waterproofing Treatment To The Reinforced Cement Concrete Structures Like Retaining Walls Of The Basement, Water Tanks, Roof Slabs, Podiums, Reservior, Sewage & Water Treatment Plant, Tunnels / Subway And Bridge Deck Etc., Prepared By Mixing In The Ratio Of 5 : 2 (5 Parts Integral Crystalline Slurry : 2 Parts Water) For Vertical Surfaces And 3 : 1 (3 Parts Integral Crystalline Slurry : 1 Part Water) For Horizontal Surfaces And Applying The Same From Negative (Internal) Side With The Help Of Synthetic Fiber Brush. The Material Shall Meet The Requirements As Specified In Aci-212-3R-2010 I.E By Reducing Permeability Of Concrete By More Than 90% Compared With Control Concrete As Per Din 1048 And Resistant To 16 Bar Hydrostatic Pressure On Negative Side. The Crystalline Slurry Shall Be Capable Of Self-Healing Of Cracks Up To A Width Of 0.50Mm. The Work Shall Be Carried Out All Complete As Per Specification And The Direction Of The Engineerincharge. The Product Performance Shall Carry Guarantee For 10 Years Against Any Leakage.For Vertical Surface Two Coats @0.70 Kg Per Sqm , 22.23.2:Providing And Applying Integral Crystalline Slurry Of Hydrophilic In Nature For Waterproofing Treatment To The Reinforced Cement Concrete Structures Like Retaining Walls Of The Basement, Water Tanks, Roof Slabs, Podiums, Reservior, Sewage & Water Treatment Plant, Tunnels / Subway And Bridge Deck Etc., Prepared By Mixing In The Ratio Of 5 : 2 (5 Parts Integral Crystalline Slurry : 2 Parts Water) For Vertical Surfaces And 3 : 1 (3 Parts Integral Crystalline Slurry : 1 Part Water) For Horizontal Surfaces And Applying The Same From Negative (Internal) Side With The Help Of Synthetic Fiber Brush. The Material Shall Meet The Requirements As Specified In Aci-212-3R-2010 I.E By Reducing Permeability Of Concrete By More Than 90% Compared With Control Concrete As Per Din 1048 And Resistant To 16 Bar Hydrostatic Pressure On Negative Side. The Crystalline Slurry Shall Be Capable Of Self-Healing Of Cracks Up To A Width Of 0.50Mm. The Work Shall Be Carried Out All Complete As Per Specification And The Direction Of The Engineerin-Charge. The Product Performance Shall Carry Guarantee For 10 Years Against Any Leakage.For Horizontal Surface One Coat @1.10 Kg Per Sqm. , Od245978/2025-2026:Providing And Fixing 1St Quality Ceramic Antiskid Glazed Floor Tiles Conforming To Is :15622 (Thickness To Be Specified By The Manufacturer ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In-Charge In Skirting, Risers Of Steps And Dados Over 12 Mm Thickbed Of Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 8.31:Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 (Thickness To Be Specified By The Manufacturer), Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer-In- Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. , 11.41.2:Providing And Laying Vitrified Floor Tiles In Different Sizes (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Make, In All Colours And Shades, Laid On 20 Mm Thick Cement Mortar 1:4(1 Cement : 4 Coarse Sand), Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete.Size Of Tile 600 X 600 Mm. , 11.46.2:Providing And Laying Vitrified Tiles Indifferent Sizes (Thickness To Be Specified By Manufacturer), With Water Absorption Less Than 0.08 % And Conforming To I.S. 15622, Of Approved Make, In All Colours & Shade, In Skirting, Riser Of Steps, Over 12 Mm Thick Bed Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand), Including Grouting The Joint With White Cement & Matching Pigments Etc. Complete.Size Of Tile 600X600 Mm , 25.1:Providing And Supplying Aluminium Extruded Tubular And Other Aluminium Sections As Per The Architectural Drawings And Approved Shop Drawings , The Aluminium Quality As Per Grade 6063 T5 Or T6 As Per Bs 1474,Including Super Durable Powder Coating Of 60-80 Microns Conforming To Aama 2604 Of Required Colour And Shade As Approved By The Engineer-In-Charge. ( The Item Includes Cost Of Material Such As Cleats, Sleeves, Screws Etc. Necessary For Fabrication Of Extruded Aluminium Frame Work. Nothing Extra Shall Be Paid On This Account).The Weight Of Aluminum Extruded Section Shall Be Taken For Purpose Of Payment , 25.2:Designing, Fabricating, Testing, Protection, Installing And Fixing In Position Semi (Grid) Unitized System Of Structural Glazing (With Open Joints) For Linear As Well As Curvilinear Portions Of The Building For All Heights And All Levels, Including: A) Structural Analysis & Design And Preparation Of Shop Drawings For The Specified Design Loads Conforming To Is 875 Part Iii (The System Must Passed The Proof Test At 1.5 Times Design Wind Pressure Without Any Failure), Including Functional Design Of The Aluminum Sections For Fixing Glazing Panels Of Various Thicknesses, Aluminium Cleats, Sleeves And Splice Plates Etc. Gaskets, Screws, Toggles, Nuts, Bolts, Clamps Etc., Structural And Weather Silicone Sealants, Flashings, Fire Stop (Barrier)-Cumsmoke Seals, Microwave Cured Epdm Gaskets For Water Tightness, Pressure Equalisation & Drainage And Protection Against Fire Hazard Including: B) Fabricating And Supplying Serrated M.S. Hot Dip Galvanised / Aluminium Alloy Of 6005 T5 Brackets Of Required Sizes, Sections And Profiles Etc. To Accommodate 3 Dimentional Movement For Achieving Perfect Verticality And Fixing Structural Glazing System Rigidly To The Rcc/ Masonry/Structural Steel Framework Of Building Structure Using Stainless Steel Anchor Fasteners/ Bolts, Nylon Seperator To Prevent Bimetallic Contacts With Nuts And Washers Etc. Of Stainless Steel Grade 316, Of The Required Capacity And In Required Numbers. C) Providing And Filling, Two Part Pump Filled, Structural Silicone Sealant And One Part Weather Silicone Sealant Compatible With The Structural Silicone Sealant Of Required Bite Size In A Clean And Controlled Factory / Work Shop Environment , Including Double Sided Spacer Tape, Setting Blocks And Backer Rod, All Of Approved Grade, Brand And Manufacture, As Per The Approved Sealant Design, Within And All Around The Perimeter For Holding Glass. D) Providing And Fixing In Position Flashings Of Solid Aluminium Sheet 1 Mm Thick And Of Sizes, Shapes And Profiles, As Required As Per The Site Conditions, To Seal The Gap Between The Building Structure And All Its Interfaces With Curtain Glazing To Make It Watertight. E) Making Provision For Drainage Of Moisture/ Water That Enters The Curtain Glazing System To Make It Watertight, By Incorporating Principles Of Pressure Equalization, Providing Suitable Gutter Profiles At Bottom (If Required), Making Necessary Holes Of Required Sizes And Of Required Numbers Etc. Complete. This Item Includes Cost Of All Inputs Of Designing, Labour For Fabricating And Installation Of Aluminium Grid, Installation Of Glazed Units, T&P, Scaffolding And Other Incidental Charges Including Wastages Etc., Enabling Temporary Structures And Services, Cranes Or Cradles Etc. As Described Above And As Specified. The Item Includes The Cost Of Getting All The Structural And Functional Design Including Shop Drawings Checked By A Structural Designer, Dully Approved By Engineer-In-Charge. The Item Also Includes The Cost Of All Mock Ups At Site, Cost Of All Samples Of The Individual Components For Testing In An Approved Laboratory, Field Tests On The Assembled Working Structural Glazing As Specified, Cleaning And Protection Till The Handing Over Of The Building For Occupation. In The End, The Contractor Shall Provide A Water Tight Structural Glazing Having All The Performance Characteristics Etc. All Complete As Required, As Per The Architectural Drawings, As Per Item Description, As Specified, As Per The Approved Shop Drawings And As Directed By The Engineerin- Charge. Note:- 1. The Cost Of Providing Extruded Aluminium Frames, Shadow Boxes, Extruded Aluminium Section Capping For Fixing In The Grooves Of The Curtain Glazing And Vermin Proof Stainless Steel Wire Mesh Shall Be Paid For Separately Under Relevant Items Under This Sub-Head. However, For The Purpose Of Payment, Only The Actual Area Of Structural Glazing (Including Width Of Grooves ) On The External Face Shall Be Measured In Sqm. Up To Two Decimal Places. Note:-2. The Following Performance Test Are To Be Conducted On Structural Glazing System If Area Of Structural Glazing Exceeds 2500 Sqm From The Certified Laboratories Accreditated By Nabl(National Accreditation Board For Testing And Calibration Laboratories), Department Of Science & Technologies, India. Cost Of Testing Is Payable Separately. The Nit Approving Authority Will Decide The Necessity Of Testing On The Basis Of Cost Of The Work, Cost Of The Test And Importance Of The Work. Performance Testing Of Structural Glazing System Tests To Be Conducted In The Nbl Certified Laboratories 1. Performance Laboratory Test For Air Leakage Test (-50Pa To ? 300Pa) & (+50Pa To +300Pa) As Per Astm E-283-04 Testing Method For A Range Of Testing Limit 1 To 200 Mvhr? 2. Static Water Penetration Test. (50Pa To 1500Pa) As Per Astme- 331-09 Testing Method For A Range Up To 2000 Ml.? 3. Dynamic Water Penetration (50Pa To 1500Pa) As Per Aama 501.01-05 Testing Method For A Range Upto 2000 Ml? 4. Structural Performance Deflection And Deformation By Static Air Pressure Test (1.5 Times Desing Wind Pressure Without Any Failure) As Per Astme-330-10 Testing Method For A Range Upto 50 Mm? 5. Seismic Movement Test (Upto 30 Mm) As Per Aama 501.4-09 Testing Method For Qualitative Test? Tests To Be Conducted On Site 6. Onsite Test For Water Leakage For A Pressure Range 50 Kpa To 240 Kpa (35Psi) Upto 2000Ml? , 25.3:Providing, Assembling And Supplying Vision Glass Panels (Igus) Comprising Of Hermetically-Sealed 6-12- 6 Mm Insulated Glass (Double Glazed) Vision Panel Units Of Size And Shape As Required And Specified, Comprising Of An Outer Heat Strengthened Float Glass 6Mm Thick, Of Approved Colour And Shade With Reflective Soft Coating On Surface # 2 Of Approved Colour And Shade, An Inner Heat Strengthned Clear Float Glass 6Mm Thick, Spacer Tube 12Mm Wide, Dessicants, Including Primary Seal And Secondary Seal (Structural Silicone Sealant) Etc. All Complete For The Required Performances, As Per The Architectural Drawings, As Per The Approved Shop Drawings, As Specified And As Directed By The Engineer-In-Charge. The Igus Shall Be Assembled In The Factory/ Workshop Of The Glass Processor. (Payment For Fixing Of Igu Panels In The Curtain Glazing Is Included In Cost Of Item No.26.2) For Payment, Only The Actual Area Of Glass On Face # 1 Of The Glass Panels (Excluding The Areas Of The Grooves And Weather Silicone Sealant) Provided And Fixed In Position, Shall Be Measured In Sqm. (I) Coloured Tinted Float Glass 6Mm Thick Substrate With Reflective Soft Coating On Face # 2, + 12Mm Airgap + 6Mm Heat Strengthened Clear Glass Of Approved Make Having Properties As Visible Light Transmittance (Vlt) Of 25 To 35 %, Light Reflection Internal 10 To 15%, Light Reflection External 10 To 20 %, Shading Coefficient (0.25- 0.28) And U Value Of 3.0 To 3.3 W/M2 Degree K Etc. The Properties Of Performance Glass Shall Be Decided By Technical Sanctioning Authority As Per The Site Requirement , 8.32:Designing, Fabricating, Testing, Installing And Fixing In Position Curtain Wall With Aluminium Composite Panel Cladding, With Open Grooves For Linear As Well As Curvilinear Portions Of The Building , For All Heights And All Levels Etc. Including: (A) Structural Analysis & Design And Preparation Of Shop Drawings For Pressure Equalisation Or Rain Screen Principle As Required, Proper Drainage Of Water To Make It Watertight Including Checking Of All The Structural And Functional Design. (B) Providing, Fabricating And Supplying And Fixing Panels Of Aluminium Composite Panel Cladding In Pan Shape In Metalic Colour Of Approved Shades Made Out Of 4Mm Thick Aluminium Composite Panel Material Consisting Of 3Mm Thick Fr Grade Mineral Core Sandwiched Between Two Aluminium Sheets (Each 0.5Mm Thick). The Aluminium Composite Panel Cladding Sheet Shall Be Coil Coated, With Kynar 500 Based Pvdf / Lumiflon Based Fluoropolymer Resin Coating Of Approved Colour And Shade On Face # 1 And Polymer (Service) Coating On Face # 2 As Specified Using Stainless Steel Screws, Nuts, Bolts, Washers, Cleats, Weather Silicone Sealant, Backer Rods Etc. (C) The Fastening Brackets Of Aluminium Alloy 6005 T5 / Ms With Hot Dip Galvanised With Serrations And Serrated Washers To Arrest The Wind Load Movement, Fasteners, Ss 316 Pins And Anchor Bolts Of Approved Make In Ss 316, Nylon Separators To Prevent Bi-Metallic Contacts All Complete Required To Perform As Per Specification And Drawing The Item Includes Cost Of All Material & Labour Component, The Cost Of All Mock Ups At Site, Cost Of All Samples Of The Individual Components For Testing In An Approved Laboratory, Field Tests On The Assembled Working Curtain Wall With Aluminium Composite Panel Cladding, Cleaning And Protection Of The Curtain Wall With Aluminium Composite Panel Cladding Till The Handing Over Of The Building For Occupation. Base Frame Work For Acp Cladding Is Payable Under The Relevant Aluminium Item.S The Contractor Shall Provide Curtain Wall With Aluminium Composite Panel Cladding, Having All The Performance Characteristics All Complete , As Per The Architectural Drawings, As Per Item Description, As Specified, As Per The Approved Shop Drawings And As Directed By The Engineer-In-Charge. However, For The Purpose Of Payment, Only The Actual Area On The External Face Of The Curtain Wall With Aluminum Composite Panel Cladding (Including Width Of Groove) Shall Be Measured In Sqm. Up To Two Decimal Places. , 10.6.1:Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Is: 4454 - Part 1 And M.S. Top Cover Of Required Thickness For Rolling Shutters.80X1.25 Mm M.S. Laths With 1.25 Mm Thick Top Cover , 10.7:Providing And Fixing Ball Bearing For Rolling Shutters. , 10.17:Providing And Fixing M.S. Fan Clamp Type I Or Ii Of 16 Mm Dia M.S. Bar, Bent To Shape With Hooked Ends In Reinforced Cement Concrete Slabs Or Beams During Laying, Including Painting The Exposed Portion Of Loop, All As Per Standard Design Complete. , 50.12.2.5:Providing & Fixing Poly Carbonate Multi Wall Plain Sheet 8 Mm Thick As Approved By The Engineer In Charge And Should Be Supplied In A Single Length Of 12 M Or As Decide By The Engineer In Charge. The Sheets Shall Be Fixed Using Self Drilling/ Self Tapping Screw Of Size ( 5.5X55mm) With Epdm Seal Complete Upto Any Pitch In Horizontal /Vertical / Curved Surface, But Excluding The Cost Of Purlins, Rafters, Trusses, And Including Cutting To Size And Shapes Where Ever Required. , 10.25.1:Item Shifted To Sub Head 14 As Item 14.73 Item Shifted To Head 14 As Item 14.74 Steel Work Welded In Built Up Sections/Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Stringers, Treads,Landings Etc. Of Stair Cases, Including Use Of Chequered Plate Wherever Required, All Complete , 5.28:Providing And Fixing In Position 12 Mm Thick Bitumen Impregnated Fibre Board Conforming To Is: 1838, Including Cost Of Primer, Sealing Compound In Expansion Joints. , 5.43.1:Providing And Fixing In Position Stainless Steel Grade 304 Plate 1.0 Mm Thick As Per Design For Expansion Joints.200 Mm Wide , Od381639/2025-2026:Providing And Fixing Braille Directional Signage With Ada Braille Sign In Polymer Sheet With Tactile Characters And Picture. 2 Mm Thick Of Standard Size Round, Square Or Triangle In Shape Fixed By Foam Tape Mounting Including Cost Of Materials And Fixing Charges Etc Complete , Od381640/2025-2026:Providing And Fixing Braille Pictogram Signage With Aluminium Backed Acrylic Sheet With Tactile Characters And Picture. 2 Mm Thick Of Standard Size Round, Square Or Triangle In Shape Fixed By Foam Tape Mounting Including Cost Of Materials And Fixing Charges Etc Complete , Od381641/2025-2026:Providing And Fixing Signage With Vinyl Sticker Type Sheet Including Printing Ncecessary Emblems Of Standard Size, Font And Colour As Specified By The Engineer In Charge , Od381642/2025-2026:Providing And Laying Self Adhesive Polyurethane/Thermoplastic Elastomer Tactile Tiles Of Size 300X300mm In Any Colour For Hazard (Dots) &Amp;Amp; Directional (Lines) For Visually Impaired Persons Having Size Of 300X300x2 Mm At Base And 6.5 Mm At Projected Area Of Dash And Dots Including Cost Of All Materials And Labour Charges Etc. , Od381643/2025-2026:Providing And Fixing Special Type Chest Support Stainless Steel Grab Bar For Urinals In Which The Front Bar Have 100Mm Long For Chest Suppoert And Side U Shaped Bars Of Length 600Mm Is Provided For User To Hold On While Standing Etc Including Cost Of Materials And Conveyance Etc Complete , Od381645/2025-2026:Providing And Fixing Access Friendly Drinking Water Dispensor Unit With Lever Handle Tap Mounted On Wall With Special Type Stand Etc Including Cost Of Unti And Conveyance Etc Complete , Sanitary And Plumbing Works , 17.4.1:Providing And Fixing White Vitreous China Flat Back Or Wall Corner Type Lipped Front Urinal Basin Of 430X260x350 Mm And 340X410x265 Mm Sizes Respectively With Automatic Flushing Cistern With Standard Flush Pipe And C.P. Brass Spreaders With Brass Unions And G.I. Clamps Complete, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls And Floors Wherever Required:One Urinal Basin With 5 Litre White P.V.C. Automatic Flushing Cistern , 8.10.2:Providing And Fixing Stone Slab With Table Rubbed, Edges Rounded And Polished, Of Size 75X50 Cm Deep And 1.8 Cm Thick, Fixed In Urinal Partitions By Cutting A Chase Of Appropriate Width With Chase Cutter And Embedding The Stone In The Chase With Epoxy Grout Or With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 6 Mm Nominal Size) As Per Direction Of Engineer-In Charge And Finished Smooth.Granite Stone Of Approved Shade , 17.2.1:Providing And Fixing White Vitreous China Pedestal Type Water Closet (European Type W.C. Pan) With Seat And Lid, 10 Litre Low Level White P.V.C. Flushing Cistern, Including Flush Pipe, With Manually Controlled Device (Handle Lever), Conforming To Is : 7231, With All Fittings And Fixtures Complete, Including Cutting And Making Good The Walls And Floors Wherever Required:W.C. Pan With Isi Marked White Solid Plastic Seat And Lid , 17.7.2:Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630 X 450 Mm With A Single 15 Mm C.P. Brass Pillar Tap , 17.8:Providing And Fixing White Vitreous China Pedestal For Wash Basin Completely Recessed At The Back For The Reception Of Pipes And Fittings. , 17.70.1:Providing And Fixing Ptmt Bottle Trap For Wash Basin And Sink.Bottle Trap 31 Mm Single Piece Moulded With Height Of 270 Mm, Effective Length Of Tail Pipe 260 Mm From The Center Of The Waste Coupling, 77 Mm Breadth With 25 Mm Minimum Water Seal, Weighing Not Less Than 260 Gms , 18.53.1:Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore , 50.17.1.5:Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , 50.17.1.3:Supplying And Fixing Cp Towel Rod 60Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. , Od246010/2025-2026:Heavy Duty Stainless Steel Cover For Concealed Floor Trap For Urinal - Providing And Fixing 125X125mm Dia Heavy Duty Stainless Steel Cover For Concealed Floor Trap Isi 304 Cover, For Urinal. , Od245988/2025-2026:Supplying, Installing, Testing & Commissioning At Site In Position 110Mm Dia Deep Seal Pvc P Trap With Boss Tee And Access Cap Including All Necessary Fittings And Supports Complete. , Od245999/2025-2026:C.P. Cast Brass Or Stainless Steel Square Flat Cut Lock Anti Cockroach Grating Cover -Providing And Fixing Heavy Duty Stainless Steel Square Flat Cut Lock Anti Cockroach Trap Stainless Steel A Isi 304 With 125X125 Mm. Grating, For 110Mm. Floor Traps. , Od245990/2025-2026:Pvc Floor Trap - Providing, Fixing, Testing And Commissioning At Site In Position Pvc Floor Trap, With Suitable Supporting On Gi Slotted Rails (1.6Mmthick) Full Threaded Rod, Anchor Fasteners Etc. Complete In All Respects - 50/75 Mm Dia Inlet/Outlet (In Ceiling) , Od246000/2025-2026:Pvc Multi Floor Trap - Providing, Fixing, Testing And Commissioning At Site In Position Pvc Multi Floor Trap, With Suitable Supporting On Gi Slotted Rails (1.6Mmthick) Full Threaded Rod, Anchor Fasteners Etc. Complete In All Respects - 50/75 Mm Dia Inlet/Outlet (In Ceiling) , 50.18.7.2.2:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer -In-Charge 20 Mm Dia 10 Kgf/Cm2- Internal Work - Exposed On Wall , 50.18.7.3.2:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 25 Mm Dia 10Kgf/ Cm2- Internal Work- Exposed On Wall , 50.18.7.4.1:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 32 Mm Dia 10Kgf/Cm2- Internal Work - Exposed On Wall , 50.18.7.5.1:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 40 Mm Dia 10 Kgf/Cm2- Internal Work- Exposed On Wall , 50.18.7.6.1:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 50 Mm Dia 10 Kfg/Cm - Internal Work- Exposed On Wall , 50.18.8.2.2:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 20 Mm Pipe 10 Kgf/ Cm2 , Od246003/2025-2026:Providing And Fixing Pvc Pipes Includings Of Pipes With One Step Pvc Solvent Cement, Trenching Refilling &Amp; Testing Of Joints Complete As Per Direction Of Engineer In Charge. 63 Mm Dia 10Kgf/Cm2 , Od246009/2025-2026:Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clip At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 63 Mm Dia 10 Kgf/Cm2 - External Work - Exposed On Wall , Od245991/2025-2026:Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/Clips At 1.00 M Spacing. This Included Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 75 Mm Dia 10Kgf/Cm2 - External Work- Exposed On Wall , Od245992/2025-2026:Forged Brass Ball Valve 20Mm Dia - Providing, Fixing At Site In Position Full Way Lever Operated Forged Brass Ball Valve(Screwed End)Of Brass Body With Forged Brass Hard Chrome Plate (Pn 10) Of Approved Make With Necessary Mta Fittings In Position As Per Drawings. - ¾ (20Mm) Dia , Od245996/2025-2026:Forged Brass Ball Valve 25Mm Dia - Providing, Fixing At Site In Position Full Way Lever Operated Forged Brass Ball Valve(Screwed End)Of Brass Body With Forged Brass Hard Chrome Plate (Pn 10) Of Approved Make With Necessary Mta Fittings In Position As Per Drawings. - 1&Quot; (25Mm) Dia , Od246002/2025-2026:Forged Brass Ball Valve 32Mm Dia - Providing, Fixing At Site In Position Full Way Lever Operated Forged Brass Ball Valve(Screwed End)Of Brass Body With Forged Brass Hard Chrome Plate (Pn 10) Of Approved Make With Necessary Mta Fittings In Position As Per Drawings. - 1&Frac14;&Quot; (32Mm) Dia , Od245997/2025-2026:Forged Brass Ball Valve 40Mm Dia - Providing, Fixing At Site In Position Full Way Lever Operated Forged Brass Ball Valve(Screwed End)Of Brass Body With Forged Brass Hard Chrome Plate (Pn 10) Of Approved Make With Necessary Mta Fittings In Position As Per Drawings. - 1&Frac12;&Quot; (40Mm) Dia , Od246007/2025-2026:Forged Brass Ball Valve 50Mm Dia - Providing, Fixing At Site In Position Full Way Lever Operated Forged Brass Ball Valve(Screwed End)Of Brass Body With Forged Brass Hard Chrome Plate (Pn 10) Of Approved Make With Necessary Mta Fittings In Position As Per Drawings. - 2&Quot; (50Mm) Dia , 18.19.4.2:Providing And Fixing Gun Metal Non-Return Valve Of Approved Quality (Screwed End): 50 Mm Nominal Borevertical , Od245989/2025-2026:Brass Automatic Air Release Valves - Providing, Fixing, Testing And Commissioning At Site In Positions Brass Automatic Air Release Valves, Of Approved Quality And Make On The Top Of The Vertical Water Supply Pipes As Per Specification And Drawing - 3/4&Quot;(20Mm) Dia , Od245993/2025-2026:Supplying, Installing &Amp; Testing At Site In Position Fabricated 50Mm (1&Frac12;&Quot;) Pvc Puddle Flange In The Overhead Water Tanks As Per The Drawings And The Requirement Of The Project Manager. -50Mm(1&Frac12;&Quot;) Pvc Puddle Flange 10 Kg , Od246008/2025-2026:Supplying, Installing &Amp; Testing At Site In Position Fabricated 63Mm (2&Quot;) Pvc Puddle Flange In The Overhead Water Tanks As Per The Drawings And The Requirement Of The Project Manager. - 63Mm(2&Quot;) Pvc Puddle Flange 10 Kg , Od246005/2025-2026:Supplying, Installing &Amp; Testing At Site In Position Fabricated 75Mm (2&Frac12;&Quot;) Pvc Puddle Flange In The Overhead Water Tanks As Per The Drawings And The Requirement Of The Project Manager. - 75Mm(2&Frac12;&Quot;) Pvc Puddle Flange 10 Kg , 18.33.1:Constructing Masonry Chamber 60X60x75 Cm Inside, In Brick Work In Cement Mortar 1:4 (1 Cement:4 Coarse Sand) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep (Inside) With Chained Lid And Reinforced Cement Concrete Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), I/C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand: 10 Graded Stone Aggregate 40 Mm Nominal Size) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design:With Common Burnt Clay F.P.S (Non Modular) Bricks Of Class Designation 7.5 , 50.18.7.6.2:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing . This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 50 Mm Dia 6 Kgf/Cm2 - Internal Work- Exposed On Wall , 50.18.8.6.2:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chases And Making Good The Wall Etc. 50 Mm Pipe 6 Kgf/Cm2 , 50.18.8.9.1:Providing And Fixing Pvc Pipes, Fittings Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge. Concealed Work, Including Cutting Chased And Making Good The Wall Etc. 110 Mm Pipe 6Kgf/Cm2 , 50.18.9.9.1:Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf/Cm2 , 50.18.9.10.1:Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching , Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge. 150 Mm Dia 6 Kgf/Cm2 , 50.18.9.17.1:Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clip At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 63 Mm Dia 6 Kgf/Cm2 - External Work - Exposed On Wall , 50.18.9.18.1:Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/Clips At 1.00 M Spacing. This Included Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 75 Mm Dia 6Kgf/Cm2 - External Work- Exposed On Wall , 50.18.9.19.1:Providing And Fixing Pvc Pipes Including Fixing The Pipe With Clamps/ Clips/ At 1.00 M Spacing . This Includes Jointing Of Pipes With One Step Pvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer-In-Charge 110 Mm Dia 6 Kgf/Cm2 - External Work- Exposed On Wall , Od245998/2025-2026:Providing And Fixing 100Mm Dia Cleanout With Spigot, With Ss 304 Square Frame &Amp; Round Frame With Flat Round Cover With Rubber Seal &Amp; Ss Screw Including Cost And Conveyance Of All Materials, Labour Charges, Sundries Etc Complete As Directed By The Engineer In Charge At All Levels. , Od246006/2025-2026:Supplying Approved Make Pvc Gully Trap Of Size 160 X 110Mm And Ci Grating 150Mmx150mm Size And Light Duty C.I Cover With Frames 300Mmx300mm Size(Inside) The Weight Of Cover To Be Not Less Than 4.5Kg And Frame To Be Not Less Than2.7Kg (Ci Mh Cover And Frame As Per Is:1726) Single Sealed Of Size Conveying To Size The Above Mentioned Items And Constructing 30Cmx30cm Internal Size Gully Trap Chamber And Depth Upto 60Cm,115 Thk Brick Wall In Cm 1:6 On A Foundation Of Plain Cement Concrete 1:4:8.100Mm Thick Plastering Inside With Cm 1:3,12Mm Thk With A Neat Cement Flushing Coat And Conveying To Site, Cleaning ,Installing And Testing Approved Make Pvc Gully Trap With 160Mm Outlet(Fabricated),Surrounding With Cement Concrete 1:1.5:3, 150X150mmm,Top With Ci Grating Above The Pvc Gully Trap And Light Duty Ci Cover And Frame Over The Chamber Including Cost Of All Materials, Etc Complete As Per Approved Drawing And As Directed By Engineer-In- Charge. , Od245994/2025-2026:Constructing Brick Masonry Manhole In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) With Reinforced Cement Concrete Top With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size,) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design: Inside Size 90X80 Cm And 45 Cm Deep Including C.I. Cover With Frame (Heavy Duty) 560 Mm Dia : With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , 19.8.1.1:Extra For Depth For Manholes Size 90X80 Cmwith Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 , Od245995/2025-2026:Constructing Brick Masonry Cache Basin In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand) With Reinforced Cement Concrete Top With 1:2:4 Mix (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size), Foundation Concrete 1:4:8 Mix ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size,) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand) Finished With Floating Coat Of Neat Cement And Making Channels In Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design: Inside Size 60X60 Cm And 60 Cm Deep Including C.I. Cover With Frame (Heavy Duty) 560 Mm Internal Diameter, Total Weight Of Cover And Frame To Be Not Less Than 208 Kg (Weight Of Cover 108 Kg And Weight Of Frame 100 Kg) : With Common Burnt Clay F.P.S ( Non Modular) Bricks Of Class Designation 7.5 , Od246004/2025-2026:Extra For Depth For Manholes Or Cache Basin Size 60X60 Cm With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 , Od245987/2025-2026:Construction Of Reinforced Cement Concrete Roof Rain Water Filtration Tank Of Overall Size 7.6M(L)X2.40M(W)X2.45M Depth Comprise Of A Filtration Chamber And A Collection Chamber As Per Drawings. Rates Including The Cost Of Boulders, Gravel, Etc For Filter Bed, Pvc Pipes, Labour, Etc As Specified As Per The Direction Of Engineer In Charge. Civil Parts Included In Appendix 2 , 19.32.1:Making Soak Pit 2.5 M Diameter 3.0 Metre Deep With 45 X 45 Cm Dry Brick Honey Comb Shaft With Bricks And S.W. Drain Pipe 100 Mm Diameter, 1.8 M Long Complete As Per Standard Design.With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 , Sanitary And Plumbing Works , 15.2.2:Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Or Leaner Mix ( Including Equivalent Design Mix) , 15.3:Demolishing Reinforced Cement Concrete Work Manually / By Mechanical Means Including Stacking Of Steel Bars And Disposal Of Unserviceable Material With In 50 Metres Lead As Per Direction Of Engineer -In-Charge. , 15.7.4:Demolishing Brick Work Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer-In-Charge.In Cement Mortar , 15.9.2:Demolishing Stone Rubble Masonry Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer -In- Charges:In Cement Mortar , 15.12.1:Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below , 15.12.2:Dismantling Doors, Windows And Clerestory Windows (Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area Beyond 3 Sq. Metres , 15.42.1:Dismantling C.I Or Asbestos Rain Water Pipe With Fittings And Clamps Including Stacking The Material Within 50 Metres Lead:75 To 80 Mm Dia Pipe , 15.42.2:Dismantling C.I Or Asbestos Rain Water Pipe With Fittings And Clamps Including Stacking The Material Within 50 Metres Lead:100 Mm Dia Pipe , 15.44.1:Dismantling G.I. Pipes ( External Work) Including Excavation And Refilling Trenches After Taking Out The Pipes, Manually / By Mechanical Means Including Stacking Of Pipes Within 50 Metres Lead As Per Direction Of Engineer- In- Charges:15 Mm To 40 Mm Nominal Bore , 15.44.2:Dismantling G.I. Pipes ( External Work) Including Excavation And Refilling Trenches After Taking Out The Pipes, Manually / By Mechanical Means Including Stacking Of Pipes Within 50 Metres Lead As Per Direction Of Engineer- In- Charges:Above 40 Mm Nominal Bore , 15.43.2:Dismantling Manually / By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Metres Lead As Per Direction Of Engineer -In-Charge:Bituminous Road , 15.60:Disposal Of Building Rubbish/ Malba/ Similar Unserviceable, Dismantled Or Waste Materials By Mechanical Means, Including Loading, Transporting, Unloading To Approved Municipal Dumping Ground Or As Approved By Engineer-In-Charge, Beyond 50 M Initial Lead, For All Leads Including All Lifts Involved , Drive Way And Parking , 16.91.1:Providing And Laying Factory Made Chamfered Edge Cement Concrete Paver Blocks In Footpath, Parks, Lawns, Drive Ways Or Light Traffic Parking Etc, Of Required Strength, Thickness & Size/ Shape, Made By Table Vibratory Method Using Pu Mould, Laid In Required Colour & Pattern Over 50Mm Thick Compacted Bed Of Sand, Compacting And Proper Embedding/Laying Of Inter Locking Paver Blocks Into The Sand Bedding Layer Through Vibratory Compaction By Using Plate Vibrator, Filling The Joints With Sand And Cutting Of Paver Blocks As Per Required Size And Pattern, Finishing And Sweeping Extra Sand. Complete All As Per Direction Of Engineer-In-Charge.60Mm Thick Cement Concrete Paver Block Of M-35 Grade With Approved Colour, Design &Amp; Pattern. , 16.69:Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement Concrete In Position To The Required Line, Level And Curvature Jointed With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand) , Including Making Joints With Or Without Grooves ( Thickness Of Joints Except At Sharp Curve Shall Not To More Than 5 Mm), Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer-In-Charge ( Length Of Finished Kerb Edging Shall Be Measured For Payment ). ( Precast Cement Concrete Kerb Stone Shall Be Approved By Engineer-In-Charge) , Civil Works For Garage And Solid Waste Handling , 2.8.1:Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) /Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10 Sqm On Plan), Including Dressing Of Sides And Ramming Of Bottoms, Lift Up To 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M.All Kinds Of Soil , 2.25:Filling Available Excavated Earth (Excluding Rock) In Trenches, Plinth, Sides Of Foundation Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Up To 1.5 M. , 4.1.8:Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level:1:4:8 (1 Cement : 4 Coarse Sand (Zone-Iii) Derived From Natural Sources : 8 Graded Stone Aggregate 40 Mm Nominal Size Derived From Natural Sources) , 4.3.1:Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form Work For:Foundations, Footings, Bases For Columns , Od382456/2025-2026:Rr With Departmental. Stone - Random Rubble Masonry Using Departmental Rubble In Foundation And Plinth Including Through And Bond Stone And Levelling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20 Mm Nominal Size) Upto Plinth Level With Cement Mortar 1:6 (1 Cement : 6 Coarse Sand). , 5.1.2:Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete, Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement - All Work Up To Plinth Level:1:1:5:3 (1 Cement 1.5 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources) , 5.3:Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs, Having Slope Up To 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Up To Floor Five Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, With1:1.5:3 (1 Cement : 1.5 Coarse Sand (Zone Iii) Derived From Natural Sources: 3 Graded Stone Aggregate 20 Mm Nominal Size Derived From Natural Sources). , 5.9.3:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Suspended Floors, Roofs, Landings, Balconies And Access Platform , 5.9.5:Centering And Shuttering Including Strutting, Etc. And Removal Of Form For:Lintels, Beams, Plinth Beams, Girders Bressumers And Cantilevers , 5.22.6:Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Levelthermo - Mechanically Treated Bars Of Grade Fe-500D Or More , 5.22A.6:Steel Reinforcement For Reinforced Cement Concrete Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Above Plinth Level.Thermo - Mechanically Treated Bars Of Grade Fe-500D Or More , 50.6.1.5:Solid Block Masonry Using Pre Cast Solid Blocks ( Factory Made) Of Size 30X20x20cm Or Nearest Available Size Confirming To Is 2185 Part I Of 1979 For Super Structure Up To Floor Two Level Thickness 20Cm And Above In: Cm 1:6 ( 1 Cement : 6 Coarse Sand) Etc Complete , 9.48.2:Providing And Fixing M.S. Grills Of Required Pattern In Frames Of Windows Etc. With M.S. Flats, Square Or Round Bars Etc. Including Priming Coat With Approved Steel Primer All Complete.Fixed To Openings/ Wooden Frames With Rawl Plugs Screws Etc , 13.1.1:12 Mm Cement Plaster Of Mix:1:4 ( 1 Cement : 4 Fine Sand) , 13.16.1:6 Mm Cement Plaster Of Mix:1:3 ( 1 Cement : 3 Fine Sand) , 13.7.1:12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand) , 21.1.1.1:Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections/ Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber/ Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing /Paneling, C.P. Brass/ Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge.(Glazing, Paneling And Dash Fasteners To Be Paid For Separately): For Fixed Portionanodised Aluminium (Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) , 21.1.2.1:For Shutters Of Doors, Windows &Amp; Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber/ Neoprene Gasket Required (Fittings Shall Be Paid For Separately)Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15) , 21.3.2:Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 5.50 Mm Thickness (Weight Not Less Than 12.50 Kg/Sqm) , 21.3.1:Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item):With Float Glass Panes Of 4.0 Mm Thickness (Weight Not Less Than 10Kg/Sqm) , 21.2.1:Providing And Fixing 12 Mm Thick Prelaminated Particle Board Flat Pressed Three Layer Or Graded Wood Particle Board Conforming To Is : 12823 Grade I Type Ii, In Panelling Fixed In Aluminum Doors, Windows Shutters And Partition Frames With C.P. Brass / Stainless Steel Screws Etc. Complete As Per Architectural Drawings And Directions Of Engineer - In- Charge.Pre-Laminated Particle Board With Decorative Lamination On One Side And Balancing Lamination On Other Side , 10.6.1:Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S. Laths, Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks, Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete, Including The Cost Of Providing And Fixing Necessary 27.5 Cm Long Wire Springs Manufactured From High Tensile Steel Wire Of Adequate Strength Conforming To Is: 4454 - Part 1 And M.S. Top Cover Of Required Thickness For Rolling Shutters.80X1.25 Mm M.S. Laths With 1.25 Mm Thick Top Cover , 10.7:Providing And Fixing Ball Bearing For Rolling Shutters. , 13.46.1:Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade:New Work (Two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Priming Coat Of Exterior Primer Applied @ 2.20 Kg/10 Sqm) , 13.50.3:Applying Priming Coat:With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Galvanised Iron /Steel Works , 13.50.4:Applying Priming Coat:With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brand And Manufacture On Steel Work (Second Coat) , 13.61.1:Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work , 11.3.1:Cement Concrete Flooring 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate)Finished With A Floating Coat Of Neat Cement, Including Cement Slurry, But Excluding The Cost Of Nosing Of Steps Etc. Complete.40 Mm Thick With 20 Mm Nominal Size Stone Aggregate , Od245986/2025-2026:Supply Erection And Commission Of 20 Kld, Mbbr Based Sewage Treatment Plant. The Rate Shall Be Inclusive Of Supply And Installation Of Coarse Screen Ss Make, Waste Water Transfer Pump 0.79M3/Hr,15Mtr Head, Aeration Grid, Polyethylene White Mbbr Media ? 1.5 M3, Electric Motor Driven Air Blower Of 50M3/Hr At 0.4 Mtr Head, Online Dosing Pump, Filter Feed Pump 0.79M3/Hr, 25Mtr Head, Psf &Amp; Acf For 250 Ltr Capacity Frp Make, All Plumbing Works, Electrical Control Panel(With Auto And Manual Operation), Float Switch, Cabling Etc Inside The Plant For Success For Working Of Stp As Per Kspcb Norms.(All Pumps,Blower Should Have Working And Stand-By) , Electrical Works , 9.1.7:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 X 10 Sq. Mm (22Mm) , 9.1.21:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 35 Sq. Mm (32Mm) , 9.1.22:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 1/2 X 50 Sq. Mm (35Mm) , 9.1.32:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 10 Sq. Mm (25Mm) , 9.1.34:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 25 Sq. Mm (28Mm) , 9.1.24:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 95 Sq. Mm (45Mm) , 9.1.23:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 1/2X 70 Sq. Mm (38Mm) , 9.2.20:Supplying And Making Outdoor End Termination With Cast Resin Compound Including Aluminium Lugs And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 1/2 X 70 Sq. Mm , 9.2.21:Supplying And Making Outdoor End Termination With Cast Resin Compound Including Aluminium Lugs And Other Jointing Materials For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.3 1/2 X 95 Sq. Mm , Od269584/2025-2026:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required. 3C X 4 Sq. Mm , Od269590/2025-2026:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 4 Sq. Mm , Od269579/2025-2026:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 6 Sq. Mm , 9.1.33:Supplying And Making End Termination With Brass Compression Gland And Aluminium Lugs For Following Size Of Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade As Required.4 X 16 Sq. Mm (28Mm) , 7.8.1:Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required.Upto 35 Sq. Mm (Clamped With 1Mm Thick Saddle) , 7.8.2:Laying And Fixing Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size On Cable Tray As Required.Above 35 Sq. Mm And Upto 95 Sq. Mm (Clamped With 25X3mm Ms Flat Clamp) , 90.12.10.3:Supply & Laying Of Dwc Pipe In Ordinary Soil 0.75M Below Ground Level Including Excavation63/50 Mm Or Nearest Size , 90.12.5.30:Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1Kv Grade Of The Following Sizes In The Existing Rcc/ Hume / Stone Ware/ Gi/ Dwc Pipe As Required.3.5 Core 70 Sq Mm , 90.12.5.42:Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1Kv Grade Of The Following Sizes In The Existing Rcc/ Hume / Stone Ware/ Gi/ Dwc Pipe As Required.4 Core 25 Sq Mm , 4.1.3:Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. 225 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.1.4:Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness , 4.1.6:Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. 450 Mm Width X50 Mm Depth X 2.0 Mm Thickness , 1.21.2:Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm , 90.11.1.14:Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required4 Way (8+12) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator/ Rccb/ Rcbo As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , 90.11.1.15:Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required6 Way (8+18) - Double Cover Tpn Vertical Db With Provision For Fixing 4P Mcb / Isolator/ Rccb/ Rcbo As Incomer And Sp/ Tp Mcb As Outgoing (Ip 42/43) , 2.3.3:Supplying And Fixing Following Way, Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240 Volts, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) 12 Way, Double Door , 90.11.1.10:Supply And Installation Of Sheet Steel, Phosphatised And Painted, Dust And Vermin Proof Enclosure Of Mcb Db Including Copper /Brass Bus Bar, Neutral Link, Earth Bus And Din Rail Suitable For Fixing Mcb/ Isolator Etc. Fixed On Wall Using Suitable Anchor Bolts Or Fixed In Recess Including Cutting Hole On The Wall , Making Good The Damages, Colour Washing Etc. As Required4 Way (8+12) - Three Phase Double Cover (Ip 42/43) , 2.10.1:Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Single Pole , 2.11:Supplying And Fixing Single Pole Blanking Plate In The Existing Mcb Db Complete Etc. As Required. , 2.14.1:Supplying And Fixing Following Rating, Double Pole, (Single Phase And Neutral),240 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 25 Amps , 2.10.4:Supplying And Fixing 5A To 32 A Rating, 240/415 Volts, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. Triple Pole , 2.15.2:Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 Volts, Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 30 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 40 Amps , Od269567/2025-2026:Supplying And Fixing Following Rating, Four Pole, (Three Phase And Neutral), 415 Volts,Residual Current Circuit Breaker (Rccb), Having A Sensitivity Current 100 Milli Amperes In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63A , 2.13.2:Supplying And Fixing Following Rating, Four Pole, 415 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.63 Amps , 2.12.1:Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps , 90.6.6.3:Supply And Drawing Frls Pvc Insulated & Sheathed 650/1100 V Grade 3 Core Copper Conductor Flat Cable For Submersible Pump Motor Conforming To Is 694 Part I 1990 As Required Including Giving Necessary Connections Of The Following Sizes.4 Sq Mm , 1.10.3:Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group C , 1.11:Wiring For Twin Control Light Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, 2 Way Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required. , 1.14.1:Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2x1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire , 1.14.2:Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2x 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire , 1.24.1:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5/6 Amps Switch , 1.24.3:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15/16 Annual Periodical Maintenance Switch , 1.24.4:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5/6 Annual Periodical Maintenance Socket Outlet , 1.24.5:Supplying And Fixing Following Modular Switch/ Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15/16 Annual Periodical Maintenance Socket Outlet , Od269574/2025-2026:Sitc Of 40A , 4 Pole Isolator In 5X8 Sintex Outdoor Enclosure. , 1.27.2:Supplying And Fixing Following Size/ Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module (100Mmx75mm) , 1.55.3:Wiring For Group Controlled (Looped) Light Point/Fan Point/Exhaust Fan Point/ Call Bell Point ( Without Independent Switch Etc.) With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit, And Earthing The Point With 1.5 Sq. Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.Group C , 90.3.19.3:Supply Conveyance, Installation, Testing And Commissioning The Light Fittings Of Following Types Made From Crca Sheet 0.5Mm Thickness With All Accessories And Lamps Directly On Wall And Giving Connections With 16/0.20 Mm 3 Core Pvc Insulated And Sheathed Round Copper Conductor Flex Wire Or Extending The Original Wiring And Giving Connections As Required1200 Mm 1X20w Led Lamp With Box Type Fixture , 5.4:Earthing With G.I. Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories, And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2.7 Metre Long Etc. With Charcoal/ Coke And Salt As Required. , 5.15:Providing And Fixing 25 Mm X 5 Mm G.I. Strip On Surface Or In Recess For Connections Etc. As Required. , 90.16.5.3:Supply Of Superior Quality Copper Earth Socket For The Following Size Of Earth Conductor Including Crimping Etc. As Required.3.15 Mm (10 Swg) , 90.16.1.3:Supply And Drawing Bare Earthing Conductors Of The Following Sizes Along With Wiring/ Cables And Giving Connection As Required3.15 Mm Copper Conductor ( 10 Swg) , 2.21:Providing And Fixing M.V. Danger Notice Plate Of 200 Mm X 150 Mm, Made Of Mild Steel, At Least 2 Mm Thick, And Vitreous Enameled White On Both Sides, And With Inscription In Single Red Colour On Front Side As Required. , Od269581/2025-2026:Supply Of 50 Sqmm 3.5 Core Pvc/Xlpe Insulated Armoured Cable With Aluminum Conductors For Working Voltages Up To And Including 1100 Volts Conforming Is 1584/Part /1988 For Pvc Is 7098 Part I For Xlpe , Od269586/2025-2026:Supply Of 70 Sqmm 3.5 Core Pvc/Xlpe Insulated Armoured Cable With Aluminum Conductors For Working Voltages Up To And Including 1100 Volts Conforming Is 1584/Part I/1988 For Pvc Is 7098 Part I For Xlpe , Od269588/2025-2026:Supply Of 10 Sqmm 4 Core Pvc/Xlpe Insulated Armoured Cable With Aluminum Conductors For Working Voltages Up To And Including 1100 Volts Conforming Is 1584/Part I/1988 For Pvc Is 7098 Part I For Xlpe , Od269592/2025-2026:Supply Of 4 Sqmm 3 Core Pvc/ Xlpe Insulated Armoured Cable With Aluminum Conductors For Working Voltages Up To And Including 1100 Volts Conforming Is 1584/Part I/1988 For Pvc Is 7098 Part I For Xlpe , Od269566/2025-2026:Supply Of 10 Sqmm 3 Core Pvc/ Xlpe Insulated Armoured Cable With Aluminium Conductors For Working Voltages Up To And Including 1100 Volts Conforming Is 1584/Part I/1988 For Pvc Is 7098 Part I For Xlpe , 90.12.6.28:Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 35 Sq Mm , 90.12.6.30:Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 70 Sq Mm , 90.12.6.31:Supply & Laying Of One No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1 Kv Grade Of The Following Sizes In The Existing Masonry Open Duct As Required.3.5 Core 95 Sq Mm , 90.12.1.14:Supply & Laying Of One Number Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable Of 1.1Kv Grade Of The Following Sizes In Ground Including Excavation Of Trench Of Size 35 X 75 Cm, Refilling The Trench Etc. As Required But Excluding Sand Cushioning And Protective Covering (In Ordinary Soil).3 Core 10 Sq Mm , 90.12.7.28:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.3.5 Core 35 Sq Mm With Factory Made Clamp , 90.12.7.29:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.3.5 Core 50 Sq Mm With Factory Made Clamp , 90.12.7.38:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 4 Sq Mm With Factory Made Clamp , 90.12.7.39:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 6 Sq Mm With Factory Made Clamp , 90.12.7.40:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 10 Sq Mm With Factory Made Clamp , 90.12.7.41:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 16 Sq Mm With Factory Made Clamp , 90.12.7.42:Supply, Laying And Clamping Of 1 No. Pvc Insulated And Pvc Sheathed Armoured Aluminium Power Cable, 1.1 Kv Grade Of The Following Sizes Using Clamps Noted Along With The Cables, Spacing Of Clamps Not Exceeding 60Cms, Making Good The Damages , Colour Washing Etc. As Required.4 Core 25 Sq Mm With Factory Made Clamp , Od269582/2025-2026:Supply, Installation, Testing And Commissioning Of Ups 3Kva/24V Cruze 3Kva/24V Ups Pure Sinewave Inverter (Luminous Or Equivalent Make Battery Make- Amaron/Exide)) With 1/2 Hour Backup , Od269565/2025-2026:Supplying , Installing, Testing And Commissioning Of Wp Panel For 2Nos 2 Hp Pumps, Electrical Interlock, Electronic Automatic Water Pumping Level Controller, Control Wiring Etc With Cable Connection For Level Sensors.. , Od269576/2025-2026:Supply Of 35 Sqmm 3.5 Core Pvc/Xlpe Insulated Armoured Cable With Aluminum Conductors For Working Voltages Up To And Including 1100 Volts Conforming Is 1584/Part I/1988 For Pvc Is 7098 Part I For Xlpe , Od269591/2025-2026:Supply, Install And Commission Approved Make Submersible 2 Hp Pump For Underground Sump To Over Head Tank Of Transfer Capacity 400 Lpm At 24M Head Including All Labour Charges.(Make:Kirloskar/Crompton/Ksb/Lub) , Od269594/2025-2026:Supply Of 25 Sqmm 4 Core Pvc/Xlpe Insulated Armoured Cable With Aluminium Conductors For Working Voltages Up To And Including 1100 Volts Conforming Is 1584/Part I/1988 For Pvc Is 7098 Part I For Xlpe , Od269575/2025-2026:Supply Of 6 Sqmm 4 Core Pvc/Xlpe Insulated Armoured Cable With Aluminium Conductors For Working Voltages Up To And Including 1100 Volts Conforming Is 1584/Part I/1988 For Pvc Is 7098 Part I For Xlpe , Od269570/2025-2026:Supply Of 9 W Led Bulk Head , Od269569/2025-2026:Sitc Of 4W Led Spot Lights , Od269593/2025-2026:Sitc Of 7W Led Downlighter , Od269585/2025-2026:Sitc Of 10 W Led Wall Lamp , Od269589/2025-2026:250 Mm Sweep Light Duty Exhaust Fan In Plastic Body With Self Openinglowers Working On 230V Single Phase A/C , Od269564/2025-2026:Supply Installation, Testing And Commissioning Of 1200 Mm Sweep Dia Bldc Ceiling Fan, Including Wiring The Down Rods Of Standard Length (Upto 30 Cm) With 1.5 Sq. Mm Frls Pvc Insulated, Copper Conductor, Single Core Cable Etc. As Required. , Od269563/2025-2026:Supplying And Fixing Following 4 Way Mcb Enclosure, On Surface/ Recess, Complete With Powder Painted Including Earthing Etc. As Required With 40A, 4P Isolator. , Od269580/2025-2026:Supplying And Fixing Following 4 Way Mcb Enclosure, On Surface/ Recess, Complete With Powder Painted Including Earthing Etc. As Required With 63A, 4P Isolator , Od269577/2025-2026:Supplying And Fixing Following 2 Way Mcb Enclosure, On Surface/ Recess, Complete With Powder Painted Including Earthing Etc. As Required With 40A, 2P Isolator. , Od269561/2025-2026:Sitc Of 100A Tpn Disconnector In Metal Enclosure , Od269573/2025-2026:Sitc Of 15W Solar Light On A 3M Hot Dipped Galvanized Pole , Od269572/2025-2026:Supply And Providing 6 Mm Thick And 1 M Wide Electrical Grade Chequered Type Rubber Mat To Withstand 3.3 Kv Dielectric Strength Conforming To Is 5429/1969. , Od269587/2025-2026:Sitc Of Metering Panel-3 Supply, Installation , Testing And Commissioning Of Totally Enclosed Compartmentalizeddust And Vermin Proof Cubical Segregated And Modular In Construction M.V. Panel Board (Metering Panel3) Free Standing Fabricated With14swg And 14 Swg Of Crca M.S. Sheet, Powder Coated , Bus-Barchamber ,Outgoing Switchgear Etc. (All Feeder Unit Would Be Compartmentalized), Color Coded Pvcsleeved Vertical / Horizontal Aluminium Busbar Of Required Size Of Length, (Bus-Bar Distances Shall Beminimum 32 Mm) Insulators, Hardware, Neoprene Gasket , Hinged Door, Interconnecting Single Core Multistrand Lugged Copper Wire Having Required Current Density ,100Amps 4P Isolator-1No, Aluminium Busbarof 32 X 6 Mm X 6 Mtrs-4Nos,Ryb Indicators One Each, V&A Meter-1 No Each, Ct 75/5- 3 Nos,15Va, Cl-1,32Adp Sdf With16 Amps Hrc Fuse Set-12 Nos , 1Phase, 16Amps Energy Meter-12Nos, Energy ,Sdfoperating Handle -13 Nos , Od269571/2025-2026:Metering Panel-1 Supply, Installation , Testing And Commissioning Of Totally Enclosed Compartmentalizeddust And Vermin Proof Cubical Segregated And Modular In Construction M.V. Panel Board (Metering Panel1)Free Standing Fabricated With14swg And 14 Swg Of Crca M.S. Sheet, Powder Coated , Bus-Bar Chamber,Outgoing Switchgear Etc. (All Feeder Unit Would Be Compartmentalized), Color Coded Pvc Sleeved Vertical/ Horizontal Aluminium Busbar Of Required Size Of Length, (Bus-Bar Distances Shall Be Minimum 32 Mm )Insulators, Hardware, Neoprene Gasket , Hinged Door, Interconnecting Single Core Multi Strand Luggedcopper Wire Having Required Current Density ,160Amps 4P Isolator-1No,Aluminiyum Busbar Of 50X6mmx2 Mtrs-4Nos,Ryb Indicators One Each, V&A Meter-1 No Each, Ct 150/5- 3 Nos,15Va, Cl-1,125Atpn Sdf With 100Amps Hrc Fuse Set-1 No,32Atpn Sdf With 25 Amps Hrc Fuse Set-4 Nos,100/5Metering Ct-3 Nos. ,Ct Type 100 Amps Energy Meter1no, 0-40 Amps Three Phaseenergy Meter-4Nos,Sdf Operating Handle -6 Nos , Od269568/2025-2026:Metering Panel 2 - Supply, Installation , Testing And Commissioning Of Totally Enclosed Compartmentalizeddust And Vermin Proof Cubical Segregated And Modular In Construction M.V. Panel Board (Metering Panel2) Free Standing Fabricated With14swg And 14 Swg Of Crca M.S. Sheet, Powder Coated , Bus-Barchamber ,Outgoing Switchgear Etc. (All Feeder Unit Would Be Compartmentalized), Color Coded Pvcsleeved Vertical / Horizontal Aluminium Busbar Of Required Size Of Length, (Bus-Bar Distances Shall Beminimum 32 Mm) Insulators, Hardware, Neoprene Gasket , Hinged Door, Interconnecting Single Core Multistrand Lugged Copper Wire Having Required Current Density ,160Amps 4P Isolator-1No,Aluminiyum Busbarof 50X6 Mmx2.5 Mtrs-4Nos, Ryb Indicators One Each, V&A Meter-1 No Each, Ct 150/5- 3 Nos,15Va, Cl-1 ,100Atpn Sdf With 63Amps Hrc Fuse Set-1 No,63Atpn Sdf With 50 Amps Hrc Fuse Set-1No,32Atpn Sdf With25 Amps Hrc Fuse Set-4 Nos , 63Amps Energy Meter-1No, 0-40 Amps Energymeter-3Nos,Sdf Operating Handle -7 Nos. , Od269560/2025-2026:Sitc Of Ssb-Common Utility.Supply, Installation , Testing And Commissioning Of Totally Enclosed Compartmentalized Dust Andvermin Proof Cubical Segregated And Modular In Construction M.V. Panel Board (Ssb Common Utility)Freestanding Fabricated With14 Swg Of Crca M.S. Sheet, Powder Coated, Bus-Bar Chamber, Outgoingswitchgear Etc. (All Feeder Unit Would Be Compartmentalized), Color Coded Pvc Sleeved Vertical /Horizontal Aluminium Busbar Of Required Size Of Length, (Bus-Bar Distances Shall Be Minimum 32 Mm)Insulators, Hardware, Neoprene Gasket , Hinged Door, Interconnecting Single Core Multi Strand Lugged Copper Wire Having Required Current Density ,160 Amps 4P Isolator-1No, Aluminium Busbar Of 32X6 Mm,Ryb Indicators One Each, V&A Meter-1 No Each, Ct 150/5- 3 Nos,15Va, Cl-1 , S , 63 Amps 4Pole Mccb-2 No, 63 Amps ,3Pole Mcb-1 No, 32 Amps 3 Pole Mccb -5 Nos, 32Amps 3 Pole Mcb-2 Nos, 40 3Pisolator -1No,Mccb Operating Handle -7 Nos. , Od269578/2025-2026:Supply Installation Of 125A, 415V, 4 Pole Automatic Transfer Switch With Automatic Start/Stop Operation Of Dg On Mains Failure Including Enclosure Etc With Accessories , Od269583/2025-2026:Supply Installation Testing And Commissioning Of Three Phase, 415V, 50Hz, 0.8Pf 62 Kva Diesel Generator As Per Latest Cpcb Norms With Standard Control Panel And Earth Fault Relay In Weatherproof Acoustic Enclosure , 1.33:Supplying And Fixing 3 Pin, 5 Annual Periodical Maintenance Ceiling Rose On The Existing Junction Box/ Wooden Block Including Connection Etc As Required. , 7.9:Supplying And Making Cable Route Marker With Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) Of Size 60 Cm X 60 Cm At The Bottom And 50 Cm X 50 Cm At The Top With A Thickness Of 10Cm Including Inscription Duly Engraved As Required. , Od351287/2025-2026:Supply And Fixing 80Mm Gi Pipe Medium Duty For Dg Exhaust Pipe Including Support, Clamps , Painting Using Suitable Paint Etc As Directed , Elv Works , 90.6.10.2:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required25 Mm , 1.53.1:Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface/Recessed Steel/Pvc Conduit As Required1 Run Of Cable , Od269552/2025-2026: Supply And Clamping The Following Size Of Corrugated Pvc Fiexible Conduit With Necessary Locking Ring And Check Nut At Termination Pointed Using Suitable Size Gi/Painted Ms Saddles Spacing Not Exceeding 60 Cms On Surface Including Making Good The Damages, Colour Washing Etc.As Required(25 Mm Dia) , Od269551/2025-2026:Providing & Fixing Network Video Recorder 16-Channel With Poe Port, 720P High Definition Network Video Input And Storage Support Simultaneous Hdmi And Vga Output, Resolution Up To 1920×1080P/60Hz Supports 256Mbps Bandwidth Throughput Handling, Supports 4-Channe, 1080P Video Real-Time Decoding And Synchronous Playback Supports 8 Sata Hard Disk With Capacity Up To 4Tb , Od269555/2025-2026:Supply, Installation, Testing And Commissioning Of Network Rack For Cctv, 6U X 600 Mm (W X 600Mm (D) With Front Glass Door,Side Openable Panels With Lock & Key,4Way 5A Pdu, Cable Manager,Cooling Fan,H/W Kit10 Etc , Od269554/2025-2026:Supply, Installation, Testing And Commissioning Of 19 Flat Screen Vga Colour Monitor Complete With All Other Accessories As Required. , Od269556/2025-2026: Supply, Installation, Testing And Commissioning Of Indoor Ir Ip Dome Camera 2 Mp 2.1Mm/4Mm/6Mm Focal Length Lens Capable To 1.0 Lux Sensitivity, With Ir N 480 Tv Lines. With All Connectors And Necessary Accessories For Mounting In False Ceiling/True Ceiling As Required For Complete Installation As Directed By Engineer In Charge , Od269553/2025-2026:Supply, Installation, Testing And Commissioning Of Varifocal Outdoor Bullet Camera With 2 Mp, H.264 / H.265, Built-In Ir Led, 2.8/3.6 Mm To 9/12 Mm, 20 To 30 Meters Ir Range, Ip 66 With All Connectors And Necessary Accessories For Mounting In False Ceiling/True Ceiling As Required For Complete Installation As Directed By Engineer In Charge. , Lift And Escalator , Od269559/2025-2026:Supply And Installation Of Parking System Type : Parklift Pl 411/5 Plbr.2200 2.0T Comfort Galvanised Platform Width:2200Mm Platform: Ength: 3750Mm Car Weight : 2000Mm System Coating : Hot Dip Galvanised , Od269557/2025-2026:Supply, Erection, Testing And Commissioning Of Slimline - Commercialescalator, 0.5M/S Speed, 800Mm Width , Od269558/2025-2026:Supply, Erect And Commissioning Of 13 Passenger Lift Machine Room Less Lift / 884Kgs / 3 Floors/ 3 Stops / Stainless Steel Car Cabin Car Size :1100Mm W X 2000Mm D 2100Mm H , Fire Fighting Works , Od298605/2025-2026:Sitc Of Signages (Fire Exit, Fire Duct Exit Etc.) , Od298615/2025-2026:Providing, Fixing, Test And Commission Weather/Water Proof/Corrosion Resistant Type Manual Call Point Break Glass Type, Having , Ip67 Rated, Complete As Per Technical Specifications. , 90.6.10.1:Supply And Fixing Of Following Sizes Of Light Gauge Pvc Conduit Along With Accessories In Surface/ Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required20 Mm , Od298669/2025-2026:Supplying & Laying Of 2X1.5 Sqmm Fire Survival Armoured Cable, 600/1000V Rated With Annealed Copper Conductor Having Glass Mica Fire Barrier Tape Covered By An Extruded Layer Of Cross Linkable Ethylene Propylene Rubber (Epr) Insulation And Lszh Inner Bedding, Steel Wire Armouring & Lszh Outer Sheath Complete As Required. , Od298691/2025-2026:Supplying, Installation, Testing & Commissioning Fire Alarm Sounder With Facility Tomake Announcement, Mounted In M.S. Box (16 Swg) With Hinged Cover Plate &Suitable For Operation With Amplifier I/C Line Matching Transformer Etc. Complete Asrequired , Od298708/2025-2026:Supplying And Fixing Of Fire Brigade Connection Of Cast Iron Body With Gun Metal Male Instantaneous Inlet Couplings Complete With Cap And Chain As Reqd. For Suitable Dia Ms Pipe Connection Conforming To Is 904 As Required :2 Way-100 Mm Dia M.S. Pipe , Od298733/2025-2026:Providing, Laying, Testing & Commissioning Of C Class Heavy Duty Ms Pipe Conforming To Is 3589/Is 1239 Including Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets With Black Tar Sheet For Corrosion Protection For Under Ground Pipe Line Including Excavation And Back Filling For 100 Mm Dia , Od298742/2025-2026:Providing & Fixing Of Pressure Switch In M.S. Pipe Line Including Connection Etc. As Required. , Od298865/2025-2026:Supplying, Installation, Testing And Commissioning Of Electric Driven Terrace Pump Suitable For Automatic Operation And Consisting Of Following, Complete In All Respects, As Required: (Terrace Pump)(A) Horizontal Type, Multistage, Centrifugal, Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft, Mechanical Confirming To Is : 1520 B) Suitable Hp Squirell Cage Induction Motor Tefc Type Suitable For Operation On 415 Volts, 3 Phase, 50 Hz, Acsupply With Ip55 Class Of Protection For Enclosure, Horiziontal Foot Mounted Type With Class-F Insulation, Conforming To Is-325.(C) M.S.Fabricated Common Base Plate, Coupling, Couplingguard, Foundation Bolts Etc.As Required.(D) Suitable Cement Concrete Foundation Duly Plastered And With Anti Vibration Pads900 Lpm At 35 M Head , Od298883/2025-2026:Providing, Installation, Testing And Commissioning Of Non-Return Valve Of Following Sizes Confirming To Is: 5312 Complete With Rubber Gasket, Gi Bolts,Nuts, Washers Etc.As Required : 100Mm Dia , Od298900/2025-2026:Supplying, Fixing, Testing And Commissioning Of Butterfly Valve Of Pn 1.6 Rating With Bronze/Gunmetal Seat Duly Isi Marked Complete With Nuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required :100 Mm Dia , Od298925/2025-2026:Supplying And Fixing 63 Mm Dia, 15 M Long Rrl Hose Pipe With 63 Mm Dia Male And Female Couplings Duly Bound With Gi Wire, Rivets Etc. Conforming To Is 636 (Type-A) As Required : Stainless Steel (Grade 304) , Od298931/2025-2026:Supplying & Fixing 63 Mm Dia Gun Metal Short Branch Pipe With 20 Mm Nominal Internal Diameter Size Nozzle Conforming To Is 903 Suitable For Instantaneous Connection To Interconnect Hose Pipe Coupling As Required :Stainless Steel (Grade 304) , Od298969/2025-2026:Supplying And Fixing Single Headed Internal Hydrantvalve With Instantaneous Gunmetal/Stainlesssteelcoupling Of 63 Mm Dia With Cast Iron Wheel Isi Marked Conforming To Is 5290 (Type -A) With Blankgunmetal/Stainless Steel Cap And Chain As Required :Single Headed Stainless Steel , Od299069/2025-2026:Providing Laying, Testing & Commissioning Of C Class Heavy Duty Gi Pipe,Fittingslike Elbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. Above Ground Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall/Ceiling With Suitable Clamp/Support Frame And Painting With Two Or More Coats Of Epoxy Paint Of Required Shade Complete As Required - 100 Mm , Od299104/2025-2026:Supply, Installation, Testing And Commissioning Of Manual Swing Type Fire Hose Reel Complete Set With Heavy Duty Drum / Reel, 19Mm. Dia. X 30Mtr. Long 2-Ply Polyester Yarn Braided / Rubber Braided Pressure Hose, Red Coloured, Heavy Duty Nylon On/Off Jet/Spray Nozzle, 22Mm. Isolating Valve And All Other Necessary Fixing Accessories Including Fabrication And Erection Of M.S. Support, As Per Requirement, For Fixing The Fire Hose Reel Set , Od299117/2025-2026:Supply And Fixing Of Pressure Gauge 0.00- 10.00 Kg/Cm2 , Od299127/2025-2026:Sitc Of Fire Pump Panel With With Stra-Delta Starter, With Auto/ Manual Selector, Indication Lamp For 12.5 Hp Pump And All Other Accessories , Od299138/2025-2026:Supply And Fixing Fire Extinguisher-Co2 2 Kg Type , Od299140/2025-2026:Supply And Fixing Of Fire Extinguisher-Abc 5 Kg Type , Od299387/2025-2026:Supplying, Installation, Testing & Commissioning Sector Panel Suitable For Following Zones, Complete With Visual Indications For Short Circuit Fault, Open Circuit Fault, Fire Condition And All Other Standard Facilities As Per Is:2189 With Mimic Diagram For All Area/Zone Covered, Complete With All Connections, Interconnections As Required.- 4 Zone , Transformer, Dp Structure And Associated Ht Works , Od383281/2025-2026:Supply, Installation Of 11 Kv/ 433 V , 160 Kva Transformer, With Dp Structure, Connected Switch Gears, Ab Cables And All Other Accessories, Including Supervision Charges For Ht Works (Ksebl Scope )Along With Statutory Approval From Ksei.

Key Value

Document Fees
INR 13100 /-
EMD
INR 200000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail