| 1 | Earth work excavation of foundation trench in hard soil including dressing and levelling the bed with initial lead of 50m. and 1.5 m. initial lift including all costs of labour materials required for the work etc. complete and as per direction of Engineer in charge. |
| 2 | Filling foundation and plinth with sand well watered and rammed including cost, conveyance, royalty, taxes of all materials, labours and T & P required for the work etc. complete and as per direction of Engineer-in charge. |
| 3 | Cement concrete (1:4:8) with 4 cm. crusher broken hard granite metal including laying in layers not exceeding 300 mm in depth, ramming, compacting to proper thickness, watering, curing for seven days with cost conveyance, royalty,taxes of all materials, labour and T&P required for the work etc. complete and as per direction of Engineer-in charge. |
| 4 | Brick work with Flyash Bricks in foundation & plinth in cement mortar (1:6) including cost of all materials, labour and T&P required for the work etc. complete and as per direction of Engineer-in charge. |
| 5 | Cement concrete (1:5:10) with 4 cm. Down grade size crusher broken hard granite metal including laying in layers not exceeding 300 mm in depth, ramming, compacting to proper thickness, watering, curing for proper period with cost conveyance, royality taxe |
| 6 | R.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusher broken) stone chips for RCC work with all cost of labour and materials required for the work etc complete & as per direction of Engineer-in- charge. |
| 7 | Supplying and labour charges for cutting, bending, binding & tying the grills of HYSD rod and placing the grills in proper position including cost of MS rod (SAIL) with all taxes, royalty and labour required for the work etc. complete and as directed by Engineer-in-charge. |
| 8 | Rigid and smooth centering and shuttering for R.C.C. work including false works and dismentaling then after casting including cost of materials required for the work etc. complete and as per direction of Engineer-in-charge. (i) Column base and Plinth Band |
| 9 | Rigid and smooth centering and shuttering for R.C.C. work including false works and dismentaling then after casting including cost of materials required for the work etc. complete and as per direction of Engineer-in-charge. (ii) Lintel and Wall Beam |
| 10 | Rigid and smooth centering and shuttering for R.C.C. work including false works and dismentaling then after casting including cost of materials required for the work etc. complete and as per direction of Engineer-in-charge. (iii) Column and beam. |
| 11 | Rigid and smooth centering and shuttering for R.C.C. work including false works and dismentaling then after casting including cost of materials required for the work etc. complete and as per direction of Engineer-in-charge. (iv) Slab, chajja and landing. |
| 12 | Brick work with Flyash Bricks in superstructure in cement mortar (1:6) including cost of all materials, labour and T&P required for the work etc. complete and as per direction of Engineer-in charge. |
| 13 | 12mm thick cement Plaster in CM (1:6) over brick work including racking out joints finishing smooth with proper plumb and line, curing for proper period with cost conveyance, royalty, taxes of all materials, labour and T & P required for the work etc comp.and as per direction of Engineer-in-charge. |
| 14 | 16mm thick cement plster (1:6) over Brick work including racking out joints finishing smooth with proper plumb and line curing for proper period with cost conveyance, royality, taxes of all materials, labour and T & P required for the work etc. comp.and as per direction of Engineer-in-charge. |
| 15 | 20mm thick plastering in cement mortar (1:4) including cost of all material and labour required for the work etc.complete and as per direction of Engineer-in-charge. |
| 16 | Fixing of Vitrified tiles in floors, traeds steps and landing on 25mm thick bed of cement mortar (1:1) joint with neat cement slurry etc. as per direction of Engineer-in-charge. |
| 17 | Fixing of Vitrified tiles in dado and riser on cement mortar (1:3) joint with neat cement slurry etc. as per direction of Engineer-in-charge. |
| 18 | Fixing of chequerd tiles in floors, treads steps and landing on 25mm thick bed of cement mortar (1:1) joint with neat cement slurry etc. and as per direction of Engineer-in-charge. |
| 19 | Supplying fitting fixing of M.S Doors, windows and grills in proper position including cost of all materials & labours and T & P required for the work etc. complete and as per direction of Engineer-in-charge. |
| 20 | Painting 2 coats with approved enamel paint over 1 coat of red oxide primer on new works complete with all cost of materials and labours. |
| 21 | Wall putty 2 coats with Acrylic wall putty on new works complete including cost of all material and labour required for the work etc. complete and as directed by Engineer-in-charge. |
| 22 | Wall painting 2 coats with plastic emulsion paint of approved shade on new work to give an even shade including cost of paint etc complete. and as per direction of Engineer-in-charge. |
| 23 | Finishing wall two coats with approved weather coat over 1 coat of wall primer including cost of paint, materials and labours etc complete. and as per direction of Engineer-in-charge. |
| 24 | Recessed wiring to light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FR PVC insulated single core multisrtandand copper conductor of ISI marked with 20 mm dia non metallic PVC flexible conduict with 5 AMP 250 V paino (a) Group A Finolex/ L&T/ Anchor/ Havell/ Vguard |
| 25 | Recessed wiring to light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FR PVC insulated single core multisrtandand copper conductor of ISI marked with 20 mm dia non metallic PVC flexible conduict with 5 AMP 250 V paino (a) Group B Finolex/ L&T/ Anchor/ Havell/ Vguard |
| 26 | Recessed wiring to light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FR PVC insulated single core multisrtandand copper conductor of ISI marked with 20 mm dia non metallic PVC flexible conduict with 5 AMP 250 V paino (a) Group C Finolex/ L&T/ Anchor/ Havell/ Vguard |
| 27 | S/F of 5 A Switch/ Socket on existing switch box and cover |
| 28 | Circuit submain wiring in PVC conduict (Finolex/ Anchor) (a) 2X1.5 sqmm + 1 |
| 29 | Circuit submain wiring in PVC conduict (Finolex/ Anchor) (b) 2X2.5 sqmm + 1 |
| 30 | Circuit submain wiring in PVC conduict (Finolex/ Anchor) (c) 2X4 sqmm + 1 |
| 31 | S/F Fitting of BK ANGLE HOLDER ISI MARK |
| 32 | S/F CEILING FAN 48\" AC FAN (Bajaj/ Usha) |
| 33 | S/F of 20 Watt LED Bulb |
| 34 | S/F of 4 way MCB DB single door |
| 35 | S/F of B series SP MCB (Havells/HPL/Anchor) |
| 36 | S/F of 32 Amp DP Main switch (HPL/Anchor) |
| 37 | S/F of standard earthing |
| 38 | S/F No. 8 SWG copper wire |
| 39 | Transparency Board Please Enable Macros to View BoQ information |