| 1 | Supply of Various Lab Equipments Items for Govt. P G College Guna District Guna (M.P.) |
| 2 | Waterand Soil Testing Analysis Kit (Digital) : RANGE pH 0 TO 14.00 RESOLUTION pH 0.01 ACCURACY pH 0.01 ± 1 Digit TEMP. COMP. 0 to 100 Deg. C. |
| 3 | Water Bath (06Holes) : 6 hole8 ltrs. |
| 4 | WaterBath(12Holes) :12 hole 20 ltrs. |
| 5 | Water Distillation Apparatus(Single Distillation Unit–2 Litre/hour) : Single Distillation 5 litres |
| 6 | Analytical balance : Least cosunt 0.0002g |
| 7 | Analytical weight box : 1-100g |
| 8 | Fractional weight box : 1-500mg |
| 9 | Physical Balance : 250gm accuracy 0.1g |
| 10 | Digital balance : Least count 1mg |
| 11 | Single Pandigital balance : 0.1mg 200g |
| 12 | Digital Photoelectric colorimeter : 8 filter,1 ml |
| 13 | Digital Potentiometer : With hot plate and electrodes |
| 14 | Digital Conductometer : with cell 1cc and 0.1cc |
| 15 | D.O. Meter : Polarographic DO Range: Typically 0 to 90 mg/L (milligrams per liter) or 0 to 600% saturation.RDO (Optical) DO Range: Usually 0 to 50 mg/L or 0 to 500% saturation. |
| 16 | Digital Naphelo/Turbidity meter : Digital Turbidity cum NepheloMeter Range:-, 200,1000 NTU/JTU Resolution:- 0.01 NTU/JTU Accuracy:- ± 3% FS, ± 1Digit Display:- 3½ Digit 7-Segment LED Light Source:- IR LED Detector:- Photodiode Sample System:- 60 x 25mm Clear Glass Test Tubes Power:- 230 V ± 10% AC, 50 Hz Accessories:- Test tube Set of 2, Operation Manual, Dust Cover |
| 17 | Polarimeter half shade : The specific rotation (α) is a physical property defined as the optical rotation at a path length of 1 dm, a concentration of 10 g/L, a temperature (usually 20 °C), and a light wavelength (usually sodium D line at 589.3 nm) |
| 18 | Melting point Apparatus :Melting-point measurement range: room temperature - 400°C Setting rate of the “starting temp.”: 50°C~400°C ≤5 min; 400°C~50°C ≤7 min Minimum digital display: 0.1°C Size of the capillary: φ1.4mm (outside diameter) φ1.0mm (inside diameter), 90mm Equipped with color camera and color monitor to observe Melting Point with ease Validation Program for Standard samples 8 Operator names can be storedGraphic LCD Display to display all test parameters & test instructions |
| 19 | Digital Melting point Apparatus :Melting point measurement range : Ambient to 300 deg C Starting melting point temperature : Settable from 50 to 300 deg C Heating Time : 3 Minutes (Up to 300deg C) Cooling Time : 5 Minutes (From 300 deg C) Accuracy : +/‐ 0.5 deg up to 200 +/‐ 0.8 deg from 200 to 300 Temperature display resolution : 0.1 deg C Rate of heating (deg C per minute) |
| 20 | Abbe Refractometer : Safety BS EN 60950-1:11/2006 EMC EN 55024 : 10/2003 EN 55020 : 11/2005 |
| 21 | TLC kit : Outstanding standardization and quality control Exceptional adherence, hardness and surface homogeneity. Analyzing samples with high matrix- load without sample preparation. Multiple samples analyzed in parallel.Highly cost-efficient, fast and economical |
| 22 | Centrifuge : 6000RPM |
| 23 | Corkboring Machine :Adjustable guide that permits holes to be bored in any part of a stopper, The knurled chuck - 9/16\" (14mm) shank of the eight, plated-steel borers included with the unit. The steel borers range from 3/16\" to 5/8\" (4.8mm to 15.9mm) in 1/16\" (1.6mm) increments, |
| 24 | Distillation Apparatus : single distillation 5 litres |
| 25 | Oven Hot Air : 14\"×14\"×14” |
| 26 | Voltage Stabilizer : 2kV |
| 27 | Vertex shaker : 6 tube capacity |
| 28 | Mixer Small : Moter Capacity 900 Watt |
| 29 | Water bath(Cu) : 4” |
| 30 | Heating Mantle with energy regulator : 500 w,2Litre |
| 31 | Single Crucible Heater : Helical wire coil Moldatherm® insulation Platinel® II thermocouple with 10TM compensated lead wire and polarized plug Ceramic fiber hearthplate Programmable heat-up to setpoint temperature Indicates setpoint and process temperatures Temperature: 1200°C (2192°F) Maximum Crucible Sizes: 5” (Top Vestibule ID) x 8” (Heated Depth) |
| 32 | Water Bath Rectangularsingle Walled : 6 hole 8 ltrs. |
| 33 | Water Bath Rectangular :2 hole |
| 34 | Kjeldahl distillation unit : unit of 3 tests |
| 35 | Microwave oven : 30 Ltr Convection Compatible |
| 36 | Soleextractionunit apparatus : Unit of 3 |
| 37 | Blower : 2 KW power |
| 38 | Water Analyser : Measures parameters like organic matter, nitrate, color, and aromatic hydrocarbons (PAH),should also includes a complementary module for measuring PO4, Cl2, NO2, Fe, Al by colorimetric method, and turbidity by laser diode. |
| 39 | F.E.T Charactrstics : voltage-controlled,high input impedancedevices which form an integral part of vast variety of electronics circuits |
| 40 | M.O.S.F.E.T Charactrstics :Triterminal, unipolar, voltage-controlled ,high input impedance devices which form an integral part of vast variety of electronics circuits |
| 41 | Thermistor charactsics apparatus : Instrument comprise for DC regulated power supply 0-10 VDC/150 mA,two round meter for voltage and current measurement, one thermistor is keptin oven,connection of suppliers, meters |
| 42 | Photodiode characterstics app : Wavelength Sensitivity (λP):940nm.Open Circuit Voltage : 0.39V.Reverse breakdown voltage:32V.Reverse Light current: 40μA.Reverse Dark current: 5nA.RiseTime/FallTime:45/45nS.ViewAngle:80deg. package:5mm |
| 43 | Solarcell characterstics : Normal Operating Cell Temperature Open Circuit Voltage, Short Circuit Current Maximum Power Point Maximum Power Point Voltage, Maximum Power Point Current Nominal Voltage. |
| 44 | Photo transisitor characterstics app : Low-cost visible and near-IR photodetection. Available with gains from 100 to over 1500.Moderately fast response times. |
| 45 | Hartley and colpitts oscillators : Input:230VAC,+/-10%,50Hz,Singlephase. tapped auto transformer type inductor |
| 46 | Transistorized regulator power supply : Input:230VAC,+/-10%,50Hz, Singlephase. Output Voltage: 0 – 40 V DC continuously variable through coarseand fine: +/- 0.015 % of max output or better forb variations load current |
| 47 | Series and parallel resonance circuit : at resonance the parallel circuit produces the same equationas for the series resonance circuit. Therefore, it makes no differenceif the inductor or capacitor are connected in parallelor series |
| 48 | Battery chrger 2 to 12volt : 12V/2amp Battery Charger SMPS,battery voltage-12hrs, battery cap.upto14ah, current2A |
| 49 | Callendor and barne app to det. the value of mechanical equivalent of heat: Callendar and Barne’s apparatus OMEGATYPE CFB-196.2. Constant level bath with stand. 3. Battery Eliminator, 2-12v D.C. insteps/variable at 4AIC regulated and short circuit protected OMEGA TYPE BE- 12/4 |
| 50 | Lee app to det. the hear conductivity : For determining the relative conductivity of thin layers of materials consist of cylindrical brass slab11.5cm dia and 12mm thick.On this rests a 5 cms deep hollow cylinder of the same dia with inlet and outlet tubes. |
| 51 | Physical balance: 1 to 10kg, Wooden Double Door,1/5mg |
| 52 | Screw Gauge : 0.22mm, brass material, range 0-25 |
| 53 | Stop watch Digital :Timecap.23hrs, accuracy.3sec/day,alarm-yes |
| 54 | Ammeter D.C/A.C : Callendar and Barne’s apparatus OMEGATYPECFB- 196.2.Constant level bath with stand. 3. Battery Eliminator, 2-12v D.C. insteps/variable at4AIC regulated and short circuit protected OMEGA TYPE BE-12/4 |
| 55 | Voltmeter D.C/A.C : Industrial laboratory |
| 56 | Photo conductivity experiments : industrial laboratory |
| 57 | To study the V-Icharactrsticsofthesolarcell : 115V,50/60Hz), Record the characteristic curve for a photoresistor Photoconductivity |
| 58 | LDR Charactrstics app :High strength Superior finish Lessmaintenance |
| 59 | Bending of beam : power supply 0-10Volt DC, voltmeter 0-10 Volt DC, ammeter 50mA, 100W,50 cm Wooden Plank |
| 60 | Measurement of low resistance by care foster- : Precise Bridgearrangement, Galvanometer, resistances and DCPower Supply are provided on a single board, DC Power Supply in place of acellor battery |
| 61 | Potentiometer : The transducer has been improved in order to guarantee greater reliability under all conditions |
| 62 | App to study response curve for LC Circuit : The resonance effect of the LC circuithas many important applications insignal processing and communications systems |
| 63 | Zener diode as voltage regulator power supply set :Package Contains: 1. Circuit Diagram (1Nos.) 2.Electronic Components.(Asper Component List) without Battery 3.Description of the Kit4. Components List |
| 64 | Spectrometer prism : Equilateral shape with two face spolished, inour three standard |
| 65 | Inertiatable :Backed by profound experience of our experts, weare an unparalleled name engaged in providing a high-quality assortment |
| 66 | Compound pendulum : It consists of a powdered coated steel bar of dimensions 100×3.75×0.5cm with a number of equidistant holes drilled along its length at equal intervals of 5cm |
| 67 | Cantilever to determine young modulus :The frames are fitted with self centering chucks. An accurately graduated micrometer screw |
| 68 | Horizontal torson app : Tearle\"s Pattern For investigating the torsional rigidity of rods of different material and to demonstrate that the angle of twist of a given rod over a fixed length |
| 69 | App to verify newtons law of cooling :Consists of two copper calorimeters 2\"x1\"Resting inside at rough which stands in an outer tank |
| 70 | Searle apparatus to determine the coefficient of thermal : Backed by profound experience of our experts,weare an unparalleled name engaged in providing a high-quality assortment |
| 71 | Conductivity Transformer Sodium vapour lamp :5 and 35watt, 420volts, single phase,220 input volts |
| 72 | Mercury lamp : 220-240volt, 50Hz, industrial |
| 73 | Transformer of Mercury lamp : 220-240volt,50Hz,industrial |
| 74 | Comp app to determine resolving power of telescope: optics used in this device are of research quality |
| 75 | Audio frequency generator : 1011Low Distortion Audio Generator that is used in various high scale industries.it is strictly tested |
| 76 | App for measurement of capacitance and inductance us on impedance at different frequency : Function generator: Selected wave with following specifications Frequency=1kHzAmplitude:2V Duty cycle = 50% |
| 77 | Study of Lissajous figure trainer with CROd Tray : Standard KIT for Lissajous figure with CRO, frequency calculation |
| 78 | Study of Lissajous figure trainer with CRO : Standard KIT for Lissajous figure with CRO, frequency calculation |
| 79 | CRO-Rectifier and filter characteristics apparatus : Main Supply - 220-240volt, Frequency - 50Hz, with Digital Storage Oscilloscope 100MHz Bandwidth 2CH Dual Channel |
| 80 | C.R.O. Single trace100MHZ : Digital Storage Oscilloscope uoto 100MHz Bandwidth |
| 81 | Dielectric constant apparatus : Mainly used in physics labs 220v,50-60hz, single phase, analog standard KIT |
| 82 | Half wave and full wave rectifier kit : Standard half wave/Full wave rectifier with CRO to trace the wave signal |
| 83 | Network theorem kit : 12-15v, 240volt, metal and fiber,250Ma |
| 84 | Resonance wave on LCR : The resonance effect of the LC circuit has many important applications in signal processing and communications systems. |
| 85 | Study of regulated power supply using transistor : Instrument comprises of AC Power Supply, three meters to assure Output Voltage, Output Current & AC Ripples |
| 86 | Reading telescope : Focusing arrangement is given by rack and pinion. Complete on a heavy metallic stand having pillar of 18\" length of 15mm diameter |
| 87 | Analog multimeter : 50-60hz,analog type, 220-250v,10A current |
| 88 | Compound Microscope :Temp ambient+10 c to 250c, inner chamber stainless steel, exterior powder coated gisheet, fiber glass wool |
| 89 | Lead accumulator : Battery Eliminator need to be ideally designed to be safe & reliable source of low voltage D.C. |
| 90 | Battery eliminator : 1000ohms, table mounted |
| 91 | Dissecting Microscope : for laboratory usage |
| 92 | Resistance box : argonfilledtetrode,0-80v, range 0.5-15v |
| 93 | Hybrid solar and wind energy trainer : 230 AV,27 CMS dimensions*17cms+- 15v dc,2 kgs appx. |
| 94 | Distillation Apparatus Double Capacity 5 Litre : Instrument comprises of AC Power Supply, three meters to ensure Output Voltage, Output Current & AC Ripples |
| 95 | Frank-Heartz exp : Focusing arrangement is given by rack and pinion. Complete on a heavy metallic stand having pillar of 18\" length of 15mm diameter. |
| 96 | Ganong’s Potometer : 50-60hz, analog type,220-250v,10A current |
| 97 | Thermistor characteristics app : Temp ambient+10 c to 250c, inner chamber stainless steel, exterior powder coated gi sheet, fiber glass wool |
| 98 | Ganong’s : Quartz a glass tube, which is bent twice, and a glass cylinder having a wide mouth |
| 99 | Slotted Weights/Hanger: cylindrical weights with a radial slot |
| 100 | Slide Cabinet with 12 showcase : Slide capacity: 4,500 per cabinet (54,000 slides total) Dimensions: 15.75 x 18.75 x 4.75 in. Color: Tan. Shop for Micro-Slide Cabinet Complete Unit with 12 Rows of 6 Drawers with a tan base. |
| 101 | Quadrats : area of 0.25m , rectangular/circular/irregular |
| 102 | Digital Thermometer : upto 400oC and 2 Decimal Fraction |
| 103 | Rheostate (Various length) : 120 Watts to 2500 Watts in single tube. Higher ratings with multiple tubes. Ohmic Value : 0.3Ω to 25KΩ Current Range : 0.3A to 40A |
| 104 | Binocular Dissecting Microscope: Upto 200x, Stereo microscopes offer a zooming range, typically from 6.7x to 45x or higher, Dual LED Eluminator |
| 105 | Galvanometer: with 0.1 Fraction |
| 106 | Slide Box for 50 Slides : Lining: Cork, Lock Type: Thumb LatchMaterial: ABS Plastic Dimensions: 8.2 x 3.4 x 1.4 in |
| 107 | Miliammeter Milivolmeter/ Microammeter: with 0.1 Fraction (Range – 0 to 10 mA, 0 to 10 um and 0 to 10 mV, 0 to 10 V) |
| 108 | Plug Key one way/two way : 4mm terminal with 2 removable plug includes two removable plug with plastic guards |
| 109 | Slide Box for 50 Slides :Lock Type: Thumb LatchMaterial: Dimensions: 8.2 x 3.4 x 1.4 in |
| 110 | Reversing Key : A plastic bar with two terminals and two brushes is pivoted to rotate over two contact strips |
| 111 | Four Way key : 4 mm terminal with removable plug |
| 112 | Binocular Microscope : |
| 113 | Moarse Key : Brass Arm: 152 mm x 12.7 mm square (6\" x 0.5\" square)Main Bearing Block: 25.4 mm square (1\" square) |
| 114 | Slide Readar : High-resolution images with no stitching artifacts or patchwork effects, Optimized optical beam path, True Color LED for brightfield stains |
| 115 | Water and Soil Testing Analysis kit :pH, Conductivity, TDS, DO, Salinity, mV & Temperature Measurements Highly Accurate & StableUser Friendly & Menu Driven Software16 x 2 line Alphanumeric LCD with Backlit Printer Attachment facility Storage for 999 Samples Mains Cum Battery Operated |
| 116 | Digital Multimeter : Accuracy: The largest allowable error under specific operating conditions.Resolution: The smallest increment of change the DMM can detect and display.Range: Related to resolution.Precision: Ability to provide the same measurement repeatedly under the same conditions.Display Digits: The number of digits displayed. Display Counts: A measure of the maximum value the DMM can display. |
| 117 | pH Meter : Measurement range for pH: 0.0-14.00 Accuracy for pH measurement: ±0.01 pH Resolution for pH measurement: 0.01 pH |
| 118 | Soldering Iron : 200-500 0C |
| 119 | Travelling Microscope : Resolution: Typically in the order of 0.01 mm, Travel Range: Horizontally: Up to 22 cm. Vertically: Up to 15 cm.Slow Motion Knobs: Provided for accurate readings. Microscope Tube: Eyepiece: 10x magnification.Objectives: Available in 15 mm, 50 mm, or 75 mm. |
| 120 | Digital Balance : 0.001mg |
| 121 | Bar PendulumB : Standard Configuration |
| 122 | Sodium vapor lamp : 55 W |
| 123 | Use of Vibration magnetometer to study a field: Standard Configuration |
| 124 | Apparatus to determine the value of Plank’s constant complete with photocell, light source, set of filter and power supply : Halogen lamp, Digital voltmeter and ammeter, Vacuum photo tube, filters of different colors. |
| 125 | Analytical Balance : Capacity 62g to 320g and a minimum readability from 0.01mg |
| 126 | Autoclave Portable : 29 liters |
| 127 | Automatic Burette: 1 Ltr and 500 Ltr |
| 128 | Blood Cell Calculator : 35000 to 100,000 results including histograms and scatter diagrams etc. |
| 129 | Chart & CDs related to Syllabus: Based on NEP Syllabus for Geography |
| 130 | Digital Haemoglobinometer : Self-calibration sensors that takes <60 s for each hemoglobin estimation |
| 131 | Digital pH Meter : pH range:≤2.000 to ≥14.000 |
| 132 | Digital Single Pan Balance : Capacity: 200g |
| 133 | Digital Spectrophotometer : Single Beam |
| 134 | Digital Thermometer : Accuracy : ±1°c In The Range Of -30°c ~ 150°c |
| 135 | D:igital Turbidity Meter : Detector: Photodiode, Light Source: IR LED Display: 3½ Digit 7-Segment LEDSample System: 60 x 25mm Clear Glass |
| 136 | Dissecting Microscope : Monocular 90° |
| 137 | Dissecting Tray : Rectangular with flanged edge |
| 138 | Electronic Digital Balance (0.01 mg) : Least Count:0.01 mg |
| 139 | Electronic Digital Balance (0.1 mg) : Least Count: 0.1 mg |
| 140 | Electrophoresis with Power Supply : 7x10cm gel tray UV transparent |
| 141 | Glucometer : Measuring range: 30 to 600 mg/dLBlood sample size: Typically around 0.6 μLTest time: Usually 5 seconds |
| 142 | Haemocytometer (Complete Box):Grid size: 3 x 3 mm Total area: 9 mm² Depth of chamber: 0.1 mm Volume of each small square: 0.0001 mm³ (0.1 nl) Number of squares on the grid: 80 Area of each small square: 1/80 mm² (0.0125 mm²) |
| 143 | Heating Mantle with Regulator Cap1Litre : Material-Glass Yarn, Controller-Energy Regulator Compatible, Power-300 W, Voltage -220 V, Capacity 1 Litre, Temperature 300 Degree C |
| 144 | High Speed CentrifugeA : 10000 rpm with 6 voyl |
| 145 | Homogenizer : Quick connect rotor stator generators, ranging from 5 to 20 mm (0.20 to 0.79\") in diameter, samples as small as0.03 ml or as large as 1 L |
| 146 | Laboratory Hot Air Oven : Upto 250oC with Micro Controller |
| 147 | Magnetic Stirrer with Hot Plate : Speed Range:3000rpm, Temp-upto 500oC |
| 148 | Medico Centrifuge Machine : upto 8000 rpm |
| 149 | Micropipette : 0.5-1 ml |
| 150 | Microtome(Rotary) : Specimen object feed of 25 mm and vertical stroke length of 55- 60 mm, and blade holder setting angle up to 10° with marking of 0, 5 and 10° in the blade holder. |
| 151 | Monocular Microscope:Aplantic 10xandAcromatic 20x |
| 152 | Oven(125Litres) :Upto 500oC |
| 153 | PCRThermal Cycler ; 100–150 VAC, 50–60 Hz; 220–240 VAC, 50–60 Hz;700 W maximum Display 5.7 in. |
| 154 | Permanent Slides : Standard Specifications |
| 155 | Refrigerator–310 Litres : Capacity 310 Litre |
| 156 | Slide Cabinet with 12 showcase : size 480 mm x 480mm x 140mm |
| 157 | Slide Cabinet with 6 Showcases: size 30mm x 460mm x 120mm |
| 158 | Slide Warming Table :Stainless steel with evenly distributed heating elements, pt 100 sensor |
| 159 | Sphygmomanometer :Splash-resistant housing, manual inflation and deflation, two AAA batteries included, 1500-3000 readings depending on back-light use, auto-off function. |
| 160 | Staining Racks :Wooden, Dimensions: 42.5 x 10.2 x 3.8 cm |
| 161 | Syringe Needle Destroyer : Destroy syringes from 18 gauge to 28 gauge On/off switch with a pilot lamp |
| 162 | Thin Layer Chromatography Apparatus: Minimum Div. 0.25mm |
| 163 | UV Trans-illuminator: Wavelengths: Available in 302 nm, Intensity: High, medium, and low settings. Tube Type: Equipped with 25-watt UV tubes. |
| 164 | Voltage Stabilizer :Range 100-300 Volt |
| 165 | Hot Plate : Speed Range:3000rpm, Temp-upto 400oC, |
| 166 | Water Analyzer : Measurement of PO4, Cl2, NO2, Fe, Al by colorimetric method and turbidity by laser diode, Range - 0-600 Abs/m, Typical Repeatability For low values (<10% FS), |
| 167 | Vortex Shaker: Speed Range:5000rpm Please Enable Macros to View BoQ information |