| 1 | Preparation of subgrade with Earth roller/Vibratory Power Road roller of 8 to 12 tonne capacity including making good the undulations, levelling etc. with earth or quarry spoils etc. and rerolling the subgrade |
| 2 | Earth work in excavation by mechanical means in trenches for foundation drains pipes cables etc (not exceeding in 1.5 mtr in width) and for shafits,wells, cesspits and the like not exceeding 10 sqm on plan, depth up to 1.5 mtr incl. incl. disposal of excavated earth up to 50 Mtr from cutting edge disposed earth to be levellled and neatly dress in all kinds of soil incl. dewatering of trenches during execution ( if required) |
| 3 | Providing supplying and stacking of soling including laying ramming complete as per direction of engineer incharge incl. all carriages |
| 4 | Providing and laying in position cement concrete of specified grade, excl. cost of centering and shuttering, all work up to plinth level 1:4:8 ( 1 cement : 4 course sand : 8 graded stone agg. 40 mm nominal size) crushed aggregate including all carriages / head load upto site of work complete.. |
| 5 | Providing and Laying of specified grade of reinforced cement concrete in 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone Crushed aggregate 20 mm nominal size) excluding the cost of centering , shuttering, finishing and reinforcement but incl. cost and carriages of all materials involved complete job. including all carriages |
| 6 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone Crushed |
| 7 | Centering shuttering, strutting and propping etc and removal of form work in incl. all leads lifts, carriages and scaffolding etc complete job.(foundation footing, bases of columns etc). |
| 8 | columns plinth, abutments, pillars, posts and struts etc |
| 9 | Providing and fixing factory made UPVC white colour casement/casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly einforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and ecessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Casement window single panel with S.S. friction hinges (300 x 19 x 1.9 mm), made of (small series) frame 47 x 50 mm &sash 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single toughned glass pane lazing bead of appropriate dimension. (Area of window upto 0.75 sqm.) |
| 10 | Providing and fixing factory made UPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly forced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware\"s and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion Casement door with 3D hinges made of (big series) frame 42 x 44 mm & sash 32 x 60 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm). |
| 11 | Providing and fixing with High rib profile sheet roofing including vertical/curved surface including polymer coated J. or L hooks,fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters incl all carriages upto site of work |
| 12 | Steel reinforcement for R.C.C. work ready to use \"cut and bend\"rebars of approved make from factory/workshop to construction site including placing in position and binding all complete above plinth level. 5.22C.1Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 13 | Providing and fixing Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 14 | Providing and laying in position cement concrete of specified grade, including curing but excl. cost of centering and shuttering, all work up to plinth level 1:2:4 ( 1 cement : 2 course sand : 4 graded stone agg. 20 mm nominal size) crushed aggregate including all carriages / head load upto site of work complete.. |
| 15 | Providing and Fixing of Wall Panel 40mm thick (Puff Panely and width 1metre or more insulated thick panel with 40mm PPGI Sheet Both 40+2 Kg density or as per directions of engineer incharge incl all carriage of material upto the site complete job. |
| 16 | Ganular Sub Base : Granular Sub Base/ Base/ Surface Course with Local Materials by mix in place method normal construction of Grabular Sub Base by Providing Local Material spreading in uniform layers manually on prepared surface including carriage of material from dumping site to site work(50m Avg) |
| 17 | P/L cement concrete flooring (1:2:4) mix finished with a floating coat of neat cement slurry but excluding the cost of nosing of steps etc complete 50mm thick with 20mm nominal size stone aggregate |
| 18 | Providing and Fixing of maple wood flooring 21mm thick incl. necessary shock absorbent,water proofing treatment antitermite treatment incl. all carriage of material upto the site complete job. |
| 19 | Interlocking metal T-Grid of hot dipped galvanised iron sectie of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-l runners of size 24x38 mm of length 3000 mm, cross- T of size 24x32 mm of length 1200 mm and secondary ntermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameterM-6 dash fasteners, 6 mm diafully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall SS screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer in-Charge. 31.20.1 With 15 mm thick tegular edged light weight calcium silicate false ceiling tiles. |
| 20 | P/F ACP (Aluminium composite Panel) boxing on exterior walls, soffits etc with PVDP coating and LDPE core laminated Eurbond /Altobond /Alubond exterior grade with 4mm thick composite of (0.5 mm 3mm 0.5mm) including fabrication for the same with aluminium section required hardware, silicon sealant masking tape, necessary Scaffolding etc complete job |
| 21 | PP/F of Hoadings made of 1\"\"x1\"\" hollow section complete with 1mm thick Flex including cost of lettering, printing and photographs etc complete job |
| 22 | carriage of materials by M.TSand for an average Lead of 20kms |
| 23 | Stone Aggregrate for an average lead of 10 kms |
| 24 | Surface DrainEath work in excavation by mechanical means (hydrualic excvator) in foundation, trenches , drains (Exceedind 30cm in depth , 1.5 m width as well as 10 sqm in plan , Incl. disposal of excavated soil lead up 50 m |
| 25 | Providing and laying stone soling hand packed . Incl. carraiage complete. |
| 26 | Providing and laying in position specified grade of cement concrete excluding the cost of centering, shuttering, finishing all work upto plinth level in 1:4:8 (1 cement : 4coarse sand : 8graded stone aggregate 20mm nominal size)incl all carriages both mt as well as hl upto site of work complete.. |
| 27 | Providing and laying in position specified grade of cement concrete excluding the cost of centering, shuttering, finishing all work upto plinth level in 1:3:6(1 cement : 3coarse sand : 6graded stone aggregate 20mm nominal size)incl all carriages both mt as well as hl upto site of work complete.. |
| 28 | 12mm thick cement plaster in 1:6 mix (1 cement : 6 fine sand) incl. all carriages upto site of work with all leads and lifts complete |
| 29 | Centering & shuttering including strutting, propping etc. and removal of formwork etc |
| 30 | P/L cement concrete 40mm thick cement concrete flooring (1:2:4) mix with 20mm nominal size stone aggregate finished with a floating coat of neat cement etc complete |
| 31 | Carriage of sand and bajri material 10Km lead |
| 32 | Electrical Part:-Point wiring for switch controlled primary light points with 3x1.5 sq mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduitng system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch of ABB/Legrand/Norsiys/Schneider or Equivalant make and colour housed in zinc chromate passivity GI boxes with modular cover plate complete as per specification and as required. The Job includes providing and laying of circuit wiring with 3 x 1.5 Sq.mm PVC Insulated multistranded copper to be laid through pvc conduit from DB to first switch in sub circuit complete job Including cost of condits (Seperate wiring for normal and invertor supply is to be provided and no extra circuit wiring shall be paid what so ever reason or length) Complete as required and Samples of wires/Switches/Sockets are to be approved by Engineer Incharge before execution or third party to be nominated by department if required |
| 33 | Point wiring for Ceiling fan/Exhaust points with 3x1.5 sq mm (P+N+E) FRLS PVC insulated 660/1100 volt grade flexible stranded (50 strands of 0.25 mm dia.) copper conductor wires in recessed or surface conducting system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 6 amp control switch and 240 volts 300 watt 5 step electronic speed regulator of ABB/Legrand/Norsiys/Schneider or Equivalant make and colour housed in zinc chromate passivity GI boxes with modular cover plate and with inter connections complete as per specification and as required. The Job includes providing and laying of circuit wiring with 3 x 2.5 Sq.mm PVC Insulated multistranded copper to be laid through pvc conduit from DB to first switch in sub circuit complete job Including cost of condits.(Seperate wiring for normal and invertor supply is to be provided and no extra circuit wiring shall be paid what so ever reason or length) Complete as required and Samples of wires/Switches /Sockets are to be approved by Engineer Incharge before execution or third party to be nominatedby department if required. |
| 34 | Point wiring for 10 Amp Socket out lets with 3x2.5 sq mm (P+N+E) FRLs PVC Insulated 660/1100 volt grade flexible stranded (50 strands of 0.25 mm dia.) copper conductor wires in recessed or surface conducting system incl the cost of supplying and fixing modular grid plate mounted flush mounted 3 no 240 volts 6 amp 5 pin socket out let along with 3 No\"s of 6 Amp control Switch same size from DB to first switch in sub circult of ABB/Legrand/Norsiys/Schneider or Equivalant make (Maximum two points shall be connected /provided in one circuit and no extra circuit wiring shall be paid what so ever reason or lenght) Complete as required and Smaples of wires//Switches/Sockets are to be approved by Engineer Incharge before execution or third party to be nominated by department if required |
| 35 | Point wiring for 16 Amp Socket outlets (Two out lets wired in one sub circuit ) with 3x4 sq mm (P+N+E) FRLS PVC Insulated 660/1100 volt grade flexible stranded (56 strands of 0.3 mm dia.) copper conductor wires in recessed or surface conducting system and incl the cost of supplying and fixing modular grid plate mounted flush mounted 240 volts 16 amp 6 pin combined shuttered socket out let along with 240 volt 16 Amp control Switch of ABB/Legrand/Norsiys/Schneider or Equivalant make and colour housed in zinc chromate passivity GI boxes with inter connection complete as per specifications and as required. The Job includes providing and laying of circuit wiring of same size from DB to first switch in sub circuit (Maximum two points shall be connected/provided in one required. |
| 36 | (Supply, Installation, Testing and commissioning of 50 Watts LED flood lighting luminaries having CRCA /Aluminium Body minimum lumens 100 Im/w,the luminaire housing should be crca/aluminium and the luminair optics shall have a high efficency with transmittance,average life of 50000 hrs operating temperature -10 C to + 45 C of Philips/Havells/Wipro/ Helonix/Jaguar /Trulux make incl making of necessary Connections. (Samples are to be approved by Engineer Incharge before execution after submission of data sheet on OEM Letter Pad or third party to be nominatedby department if required )The job further includes replacement warranty of fixture (if damaged /burnt out what so ever reason) for a period of two years 7 reckoned from date of sucessful commissioning /handing over of site to intending department. |
| 37 | Supply, Installation testing and commissioning of 1400 mm sweep Ceiling Fans of Crompton Greaves / Havel\"s/Usha /eq.make make (Sample to be got approved) with 3 way ceiling rose of SSK make Complete incl making of necessary connections. (Samples are to be approved by Engineer Incharge before execution or third party to be nominatedby department if required) |
| 38 | Supply and fixing modular blanking plates on existing modularswitch plates, excluding cost of plates. |
| 39 | Wiring for Circuit/sub-main witing along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires of standard make (to be got approved before installation) in recessed or surface conducting system excluding cost of conduit of following sizes. A) 2x4 SQ. mm |
| 40 | c) 2x6 sq mm for Lighting Submain + 1x6 sq mm for earth |
| 41 | c) 2x10 sq mm for heating Submain + 1x6 sq mm for earth |
| 42 | Supply and Fixing of 25 mm dia medium grade PVC conduit incl its allied accessories like bends, J boxes etc for laying of wires recessed in walls incl refcaing of walls or fitted with necessarycliffs and rowel plugs complete. |
| 43 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator)a) 8 way, Double door |
| 44 | Supplying and fixing of 32-40 Amp rating DP 240/415 volts (10 KA) \"C\" curve MCB\"s of Legrand/Siemens/ ABB /Schinder (XC60) /L&T make suitable for inductive load of following poles in the existing MCB DB complete job |
| 45 | (Supplying and fixing of 63 Amps rating DP MCB 240/415 volts (10 KA) \"C\" curve MCB of Legrand / Siemens/ABB /Schinder- (XC60)/L&T make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required. |
| 46 | Supplying and fixing of 5 Amps to 32 Amp S Pole rating 240/415 volts (10 kA) \"C\" curve MCB of Legrand / Siemens/ABB /Schinder - (XC60) /L&T make suitable for inductive load of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required. |
| 47 | Supply/Installation/testing and commissioning of Wall/floor mounted compartmentalized, 415 volts TPN MCCB Main accessories as required for panel with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices(1) Normal Incoming 100 Amp TPN MCCB with breaking capacity of25 KA thermo magnetic adjustable based of Legrand / Siemens/ ABB /Schinder-NSXm /L&T make = 1 no 160 Amp TPN Bus bar Al Strips=1 Set Volt meter =1 no,Ammeter 1 no,CT coils for Am meter 300/5A= 1 set Selector Switch = 1 No. and set of phase indicators(2) Generator Incomer 63Amp Four Pole Change over switch of Havels /Eq.make = 1 no 100 Amp TPN Bus bar Al Strips = 1 Set Volt meter =1 no Ammeter = 1 no CT coils for Am meter 300/5A = 1 set Selector Switch=1 Outgoing. 63 Amps DP MCB (10 KA) of Legrand / Siemens/ ABB /Schinder-(XC60) /L&T make = 1 No 40 Amps Double Pole MCB (10 KA) of Legrand / Siemens/ABB/Schinder-(XC60) /L&T make = 1 No 32Amps Double Pole MCB (10 KA) of Legrand/Siemens/ABB/Schinder -(XC60) /L&T make = 1 No |
| 48 | Supply/Installation/testing and commissioning of 2 Kva Smart Pure Sine Vave inverter with output Voltage of 220 V Inverter Mode |
| 49 | Supply/Installation/testing and commissioning of of Tall Tubular battery of 220 Ah battery of Apprioved Make with 5 Years Warranty. |
| 50 | Supply of 50sq.mm/3.5- core Al Cable XLPE sheathed and PVC Insulated and Steel sheathed of Havells make, including cost thimbles on input aswell as output sides |
| 51 | Laying of One Number of Armoured/Unarmoured Power Cable 1.1 kv Grade of Size Exceding 25 sq mm but not Exceeding 120 sq mm Please Enable Macros to View BoQ information |