| 1 | Item Description |
| 2 | Supply of ST Pole 11 Mtr Long |
| 3 | Supply of ACSR Consuctor |
| 4 | Supply of 11 Kv cable 3*185 Sqmm XLPE |
| 5 | Supply of 11 Kv cable 3*185 mm2 O/D |
| 6 | Supply of 11 Kv cable 3*185 sqmm straight through kit |
| 7 | Supply of 11 kvtop channel 100*50*6-2240mm |
| 8 | Supply of 63 KVA T/F 11/0.4 KV |
| 9 | Supply of MS dropper channel 100*50*2700mm |
| 10 | Supply of T/F base channel 125*65*3200mm |
| 11 | Supply of 11 Kv stay set complete |
| 12 | Supply of earthing rod 20*2500mm and 6 SWG earthingwire |
| 13 | Supply of 11 kv disc insulator 45 KN Polymer type |
| 14 | Supply of 11 kv disc fitting 45 KN Polymer type |
| 15 | Suply of 11 KV pin insulator polymer type |
| 16 | Supply of MS Angle 65*65*6mm for faracation of T/F support |
| 17 | Supply for 11 kv fuse set |
| 18 | Supply of GI wire 5 mm |
| 19 | 400 KVA compact sub station comprising of 3 Way-I in 2 out RMU Specification and 11 KV Outdoor Package of 11 KV Unipack Compact Sub- A-IIT Switchgear 11 KV 630 Amps 21KA for 3 sec SF6 insulated Extensible Comact switchgear (DV) consisting of Two Nos Fixed Manual load break switchgear and One Fixed Manual vacuum Circuit Breaker in SF6 Insulated robotically welded stainless steel enclosure having ingress Protection IP67, with series trip,self powered microprocessor based numerical over current relay (IDMTL+Inst) protection interconnection between HT switchgear and transformer shall be using ICX3RX95 sqmm Al unarmoured XLPE Cable (Make ABB/Cromnton/scpider/siemens)Self powered over current and earth fault protection relay ADR2415 (Make Ashida/Equiv)Protection CT of ratio-60/1A 25 VA SP10 Mechanical position Indicator Switch ON/OFF/EARTHED Voltage presence Indicator Fault Passage Indicator Standard Manometer Operating Handle |
| 20 | Transformer |
| 21 | 24V DC battery (Make HBL/equiv ) & charger 12Ah Capacity (Make Alan/equiv) All modules of the RMU shall be capable for cable termination of 3Cx300 sqmm Al XLPE Cable,Incoming cable termination Kits shall be in the scope of purchaser onlyB-TRANSFORMER400 KVA 11/0.4 33KV DynCopper Wound Cast Resin Dry type transformer with off clrcult tap links of range+5% to -5% Insteps of 2.5% Class of Insulation F,Temperature Rise 90 Deg Losses shall be as per IS tol.Standard losses and Impedance of 4.5% (Subiected to IS ToI) Winding Temperature Indicator with Alarm and trip Contact C-LT panel 600A ALUMINIUM Busbar (100% FOR PHASES AND 50% FOR NEUTRAL ) -1.5/2mm CRCA LT pannel, Aluminium Busbar with Current density 1A/sqmmINCOMMER FROM TRANSFORMER630A Amps 433V 36KA 4P Fixed Manual MCCB with microprocesser based over current,short circuit and earth fault relraseR.Y.B.ON ,OFF TRIP Indications Digital MFM Class I D-OUTDOOR ENCLOSURE |
| 22 | Supply ofTop Channel Clamp for 11 M STP |
| 23 | Supply of Dropper channel clamp |
| 24 | Supply of 11Kv \"E\" Bracke with nut & bolt |
| 25 | Supply of Stay Clamp |
| 26 | Supply of T/F base channel clamp |
| 27 | Supply of Cable Holding Clamp |
| 28 | Supply of GI barbed wire |
| 29 | Supply of Nut Bolt & washer |
| 30 | Supply of Stone Pad |
| 31 | Supply of GI Pipe 6\" dia |
| 32 | Supply of PG clamp for dog condutor |
| 33 | Supply of Red oxide paint |
| 34 | Supply of Rout marker |
| 35 | Supply of Allu Paint |
| 36 | Supply of Danger board & clamp with nut &bolt |
| 37 | Supply of 3x70Sqmm cable 11 |
| 38 | Supply of 3x70sqmm Joint kit |
| 39 | Labour charge |
| 40 | Grouting of ST Pole |
| 41 | Concreting of stay rod as per RESPO norms |
| 42 | Laying & dressing of5000Mtr 11 KV 3x185 sqmm XLPE cable after digging/ or laying trench or pipe line t |
| 43 | Hoisting of 11KV cable on errected pole supprot&clamping |
| 44 | Making of 11 KV 3x185 sqmm indoor/outdoor jointingkit |
| 45 | Making of 11 KV 3x185 sqmm streight through kit |
| 46 | Plinth & foundation for11/0.4 KV 400KVA Compact T/F |
| 47 | Earthing of 11/0.4KV 400 KVA Compact T/F ( 1 Nox6ofit for body earthing) |
| 48 | Errection of 400 KVA compact Sub station comprising of 3 Way - 1 In 2 out |
| 49 | Cartage of 400 KVA compact Sub station comprising of 3 Way - 1 In 2 out |
| 50 | Sandry/Miscellaneous Work |
| 51 | Cartage of allmaterial@7% |
| 52 | Erection charges of material @8% |
| 53 | Supply and Erection of 3 Phase 415V, Distribution feeder pillar for LT 100 Amp incoming 4 Nos 32 A,p TPn 12 Nos 16 Amp SPN Rating feeder type Distribution service piller suitable for outdoor installation. |
| 54 | Supply and Erection of Outdoor type Lt Distrbution Boards with rupturing capacit of 50kA at 415 V or as called for individual item (CPRI Approved manufacturer) openable in front and suitable for3 Phase 4 wire, 50Hz AC supply and ambient temperature of 45 degree C. The cubicle should be weather proof. dust proof, vermin proof and enclosure protectionshall be IP-55 as per IS 2147-1963 and IS 8623The panels/switches boards shall be fericated out of 14-SWG CRA sheet steel and provided with 16 SWG hinged including suitable foundation. Main LT Panel at sub station- 400 KVA (Type-2) Incomer 1 set of 630/800A TP MCCB with speader & Extended handle Metering o-1 incomer-1 set of Digital Ammeter with ASS -1 Set o Digital Voltmeter with VSS -1Set of LED type phase indication light (22.5mm) with cantrol MCBs Outgoing 6 Set of 250 AMP, TP MCCB with Spreader & Extended handle (5 Nos +1 No capacitor panel) 2 Set of 100 AMP, TP MCCB with Spreader & Extended handle (Installation of LT Distribution Boards for LT underground Systyem Type- A, B & C) |
| 55 | S/L of LTarmourd cable |
| 56 | 400Sqmmx3.5 Core |
| 57 | 240Sqmmx3.5 core |
| 58 | 150Sqmmx3.5 core |
| 59 | 120Sqmmx3.5 core |
| 60 | 16Sqmmx4 core |
| 61 | 10Sqmmx4 core |
| 62 | S/F of Lugs |
| 63 | 400Sqmm |
| 64 | 240Sqmm |
| 65 | 150Sqmm |
| 66 | 120Sqmm |
| 67 | 16Sqmm |
| 68 | 10Sqmm |
| 69 | S/F of Sef Earthing T-19 SOR 2018 SI NO. 725 A |
| 70 | S/F of 11 Kv GO Set |
| 71 | CC Work for foundation SOR 2020 SI no. 279 B |