}

Tender For Improvement Of Electrical Installation In M C Pry School In H Block Shakurpur Ward No 62 Under Kpz., Delhi-Delhi

Tender Notice

52137805
Tender For Improvement Of Electrical Installation In M C Pry School In H Block Shakurpur Ward No 62 Under Kpz.
Tender
Indian
Delhi
Delhi
11-11-2025

Tender Details

Tender For Improvement Of Electrical Installation In M C Pry School In H Block Shakurpur Ward No 62 Under Kpz.; 2 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. Group C 3 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6 amp switch 4 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 amp socket outlet 5 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.15/16 A switch 6 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet 7 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 8 Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recessed including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. (A) 25 mm 9 S/D following size of FR PVC insulated copper conductor 1 core cable in existing surface/recessed /PVC/ Steel conduitas reqd.(a) 3x2.5 sq mm 10 (b)6X2.5 sq mm 11 (c)3X 4 sq mm 12 ( d ) 6x4 sqmm 13 E) 3 X 6 SQ MM 14 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)(a)12 way Double door 15 (B) 8 way , Double door 16 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole 17 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 63 amps 18 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp 19 Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of following sizein the existing masonry open duct as required. Upto 35 sq.mm 20 Laying of one no PVC insulated and PVC sheathed/XPLE Al Conductor armoured power cable of 1.1KV grade of following sizeon wall surface as required. Up to 35 sq,mm (clamped with 1mm thick saddle) 21 Supply of XLPE insulated and PVC sheathed aluminium conductor armoured cable of 1.1KV grade conforming to IS-7098 (a) 2x6 sqmm 22 (b) 4x25 sqmm 23 Earthing with GI Earth pipe 4.5longx40mm dia i/c accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc (but without charcoal or coke and salt) complete as required. 24 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 25 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 26 Supply of 12 ( 300mm sweep) exhaust fan heavy duty complete withshutter, bladesetc as required 27 Supply of 3 mm thick phenolic laminated sheet 28 Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirementwith Driver efficiency >85%, Operating voltage AC140-270 Volt,freq 50/60 hz, Operating temp range 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,CRI>80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), ofminimum 50000BurningHourswith,70%ofinitial Lumenmaintained tilllife ends,CCT3000°K/ 4000°K / 5700°K/6000°K /6500°K(AsperANSIBin),SDCM(Standard Deviation Color Matching) <3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BISstandardandtrade markcertificate(T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own inhouseNABLlabsetupfor alltestingfacilitiesforLEDfixtures.completeinallrespecti/c connectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy≥120 <135lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsink ofaluminiumhousing such that LED junction temperature shall not rise above 90°C).CRCA Sheet Body (Thickness ≥ 0.50 mm)18- 22 watt 29 Supplying,installation,Testing&CommissioningofFloodLight, powdercoatedpressuredie cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%,Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P.F.≥0.95,IP-66,IK-10,CRI>80,undervoltageandovervoltageprotection, EMI-EMCasper CISPR-15,lenses for beam angle 30 deg 120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumenmaintained tilllife ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K/6000°K/6500°K(AsperANSIBin), SDCM(Standard Deviation Color Matching) <5, Maximumpowerconsumptionshouldnotmore than the specified rating and Fixture shall be ofrelevant BIS standardcompletein allrespecti/cconnectionswith1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy>135lm/Wattoutput . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C).50 watt 30 P/FHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof polebox of innerdimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nosof 6 to 32 amp single pole MCB & 63 Amp. Doublepole isolator (MCB/Isolator excluded) withneutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plateofsuitable size with danger monogram property printed on the coveretc asreqd. asreqd. 31 Supply, Installation, Testing and Commissioning ofceiling fan with Brush LessDirectCurrent(BLDC)Motor,classofinsulation: B,3nos.metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%,suitable for operation withregulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019fan Supply, earthing etc. complete as req: 1200mm,service value≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 32 Replacement of fan condenser 2.5 mfd as required.

Key Value

Document Fees
INR 590 /-
Tender Value
INR 4.66 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail