| 1 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlierand disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201. as directed by Engineer in Charge. |
| 2 | Scarifying the existing bituminous road surface to a depth of 150 mm and disposal of scarified material with a lift upto 3 m and lead upto 1000 m as per Technical Specification Clause 301.4. as directed by Engineer in Charge. |
| 3 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compactingwith vibratory roller to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5.For lead upto 250 m.as directed by Engineer in Charge. |
| 4 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting with vibratory roller to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.as directed by Engineer in Charge. |
| 5 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavatorat OMC, and compacting with vibratorywheelroller to achieve thedesired density, complete as per Technical Specification Clause 401.For Grading II Material.as directed by Engineer in Charge. |
| 6 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smoothwheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405.By Mechanical Means.as directed by Engineer in Charge. |
| 7 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with threewheel 80-100 kN static roller in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405.By Mechanical Means.as directed by Engineer in Charge. |
| 8 | Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate ( natural sand/ VSI grade finely washed crushed sand) conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, , cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant/ Weigh batch mixer, transported to site with all leads and lifts, laid with a paver with electronic sensor /by suitable means as approved by Engineer-in-charge , compacting with vibratory roller, finishing, curing and including preparation of subgrade surface if required etc. complete. as directed by Engineer in Charge. |
| 9 | Providing and applying tack coat with Bitumen emulsion (RS-1)using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.as directed by Engineer in Charge. |
| 10 | Construction of modified penetration macadam 50mm thick over prepared base by providing a layer of compacted crushed coarse aggregate using chips spreader with alternate applications of bituminous binder of VG-30 Grade @1.75kg/sq.meter and key aggregatesand rolling with a three wheel 80-100 kN static roller to achieve the desired degree of compaction as per Technical Specification Clause 506.as directed by Engineer in Charge. |
| 11 | 20mm thick Open-Graded Premix CarpetBituminous (penetration grade/modified bitumen) Binder Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant,laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. (excluding seal coat) By Mechanical Means(I) Bitumen (S-65) VG-30 as direct by engineer in charge |
| 12 | Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A , Type B (by Paver finisher) and Type C as per Technical Specification Clause 510.By Mechanical Means.Case - I:Type A-Bitumen (S-65)VG-30.as directed by Engineer in Charge. |
| 13 | Construction ofun-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side formwork (steel channel,edges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant,admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawingand Technical Specification Clause 1501(excluding dowel bars and Polythene sheet).as directed by Engineer in Charge. |
| 14 | Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granularmaterial in single row includingfixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.(A) 1200 millimeter dia. as directed by Engineer in Charge. |
| 15 | Providing and laying 600 mm dia reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1106.e. as directed by Engineer in Charge. |
| 16 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.Ordinary soil. Upto 3 m depth by mechanical means ( This item shall be used when total estimate quantity exceeds 100 cum) as directed by Engineer in Charge. |
| 17 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.II. Ordinary rock (not requiring blasting) Up to 3 meter depth.as directed by Engineer in Charge. |
| 18 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial.II. Hard rock (blasting prohibited) Upto 3 m depth including 1.5 m depth in hard rock.as directed by Engineer in Charge. |
| 19 | Dewatering including diversion of stream, providing cofferdams, bunds, etc. as may be necessary for foundation and other parts of the work and bailing out water during and after excavation as required. as directed by Engineer in Charge. |
| 20 | Dewatering including diversion of stream, providing cofferdams, bunds, etc. as may be necessary for foundation and other parts of the work and bailing out water during and after excavation as required. (A) For open Foundation (A 2) For pier (ii) for Medium Dewatering . as directed by Engineer in Charge. |
| 21 | Dewatering including diversion of stream, providing cofferdams, bunds, etc. as may be necessary for foundation and other parts of the work and bailing out water during and after excavation as required. (A) For open Foundation (A 3) For returns (ii) for Medium Dewateringas directed by Engineer in Charge. |
| 22 | Providing soling using 80mm size trap metal in 15cm. Layer including filling voids with Crushed sand/grit, ramming, watering etc. complete.as directed by Engineer in Charge. |
| 23 | Providing & Placing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 I) Plain cement concrete grade M 10 (i)Nominal mix 1:3:6. as directed by Engineer in Charge. |
| 24 | Providing & Placing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 II) Plain cement concrete grade M 15 (i)Nominal mix (1:2.5:5). as directed by Engineer in Charge. |
| 25 | Filling annular space around footing in rock as per technical specification Clause 1203.4.3.in PCC M15.as directed by Engineer in Charge. |
| 26 | Providing and fixing 25mm diameter steel anchor dowel in hard rock including drilling hole of 32 mm diameter up to 0.75 mtrs depth, placing the dowel in position and effectively grouting the hole with CM 1:1 proportion etc. complete..as directed by Engineer in Charge. |
| 27 | Supplying, fitting and placing TMT bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202.as directed by Engineer in Charge. |
| 28 | Providing & Placing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203V) Reinforced Cement Concrete grade M 30 Reinforced Cement Concrete. as directed by Engineer in Charge. |
| 29 | Providing, constructing coffer dam in river basin / dam storages as per type design including excavation, filling the middle portion with B.C. soil (in gunny bags if required).Providing impervious / semipervious materialson both sides of B.C. soil (in gunny bags if required) including ramming, compacting to the satisfaction of Engineer-in-charge till the completion of work including dismantling coffer dam after completion of works and disposing off the material as directed by the Engineer-in-charge. |
| 30 | Providing and laying plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 ,For height up to 5 meter I) Plain cement concrete grade M 15 (i) Nominal mix (1:2.5:5). as directed by Engineer in Charge. |
| 31 | Providing and laying plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 ,For height up to 5 meter II) Plain cement concrete grade M 25 (i) Nominal mix (1:1:5:3). as directed by Engineer in Charge. |
| 32 | Reinforced cement concrete of M30 Grade in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (Excluding reinforcement). as directed by Engineer in Charge. |
| 33 | Supplying, fitting and placing TMT bar reinforcement in substructrue complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202.as directed by Engineer in Charge. |
| 34 | I) Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7.P.V.C. pipe 100 mm dia.as directed by Engineer in Charge. |
| 35 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smallersize towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specificationClause 1204.3.8.as directed by Engineer in Charge. |
| 36 | Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5. R.C.C. Grade M 30.as directed by Engineer in Charge. |
| 37 | Supplying, fitting, and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202.as directed by Engineer in Charge. |
| 38 | Providing and laying cement concrete wearing course M 30 gradeincluding reinforcementcomplete as per drawing and technical specifications Clauses 800 and 1206.3.as directed by Engineer in Charge. |
| 39 | Providing fitting and fixing mild steel railing complete as per drawing and technical specifications Clause 1208.2.as directed by Engineer in Charge. |
| 40 | P.C.C. M 15 ordinary grade (1:2.5:5) levelling course below approach slab complete as per drawing and technical specifications Clauses 800 and 1211.as directed by Engineer in Charge. |
| 41 | Reinforced Cement Concrete M 25 grade approach slab including reinforcement @ 50kg/Cum and formwork complete as per drawing and technical specifications Clauses 800 and 1211.as directed by Engineer in Charge. |
| 42 | Providing tar paper bearing including laying in proper position etc. complete..as directed by Engineer in Charge. |
| 43 | Providing expansion joints with 25mm thick bituminous pad as per detailed drawings etc. complete.as directed by Engineer in Charge. |
| 44 | Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per drawings and Technical Specification Clause 1701ii) English and Roman Hyphens, commas and the like not to be measured and paid for. Detail for 100 letters of 160 millimeter height, i.e. 1600 centimeter. as directed by Engineer in Charge. |
| 45 | Providing and fixing Cautionary/Warning sign boards in Equilateral Triangle size of 600mmmade out of 3mmaluminum composite material sheetbondedwithwhiteretroreflectivesheetingof ClassB(TypeIVHighintensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint and supported on one no. ofM. S. angle iron post of size65 mm X 65 mm X 6 mm, 3.45 m long,duly paintedwithwith flat oil paint having alternate black and white bands of 25 cm width including G.I.fixturesetc;fixingtheboardsinM25gradeconcreteblockofsize60cm X60cm X75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7yearswrittenwarranty fromthemanufacturerandauthoriseddistributor/convertorissuedforfield performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay filmandthiswarrantycertificate inoriginalshouldbesubmittedtotheEngineerinchargebythe contractor/supplier. |
| 46 | Providing and fixing of retro- reflectorised informatory sign board rectangular/Square in shape having area less than 0.9 One Square Meterr made out of ____mm aluminum sheet bonded with white retro reflective sheeting of Class __ ( Type IV High intensity microprismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3, supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with two coats of grey stove enamel paint and supported on one no. mild steel angle iron post 75 mm x 75 mm x 6 mm, 3.5 mt long firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing The angle iron post shall be duly painted with one coat of epoxy primer and two coats of epoxy finish paints having alternate black and white bands of 25 cm width including GI fixures and transportation etc.complete.The nut bolts of board with angle iron post/supporting structure after fixing at site has to be electrically welded. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) sheeting shall have 7 years written warranty from the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificate in original should be submitted to the Engineer in charge by the contractor/supplier.2mm aluminum sheet Class B.as directed by Engineer in Charge. |
| 47 | Providing and fixing Cautionary/Warning sign boards in Octagone size of 750mmmade out of 4mm aluminum sheet bonded with white retro reflective sheeting ofClass B ( Type IV High intensity micro-prismatic grade sheeting-HIP) having pressure sensitive/heat activated adhesive retoreflective specified back ground, border and back side retoreflctive symbols, letters, numerals, arrow as per IRC:67-2012 Table No 8.3 Supported with back support frame 25mm x 25mm x 3mm, duly painted on back side with grey stove enamel paint andsupported on one no. ofM. S. angle iron post of size65 mm X 65 mm X 6 mm, 3.45 m long,duly paintedwithwith flat oil paint having alternate black and white bands of 25 cm width including G.I. fixtures etc; fixing the boards in M25 grade concrete block of size 60cm X 60cm X 75cm including transportation etc; complete. Class B ( Type IV High intensity micro-prismatic grade sheeting-HIP) shall have 7 years written warrantyfrom the manufacturer and authorised distributor/convertor issued for field performance including the screen printed areas and cut-out sheeting and cut-out durable transparent overlay film and this warranty certificatein original should be submitted to the Engineer in charge by the contractor/supplier. |
| 48 | Providing and fixing Aluminum-backed flexible prismatic (AFP) sheeting consisting Yellow colored flexible prismatic sheeting with non-metallic prismatic lens as Retroreflective elements and conforming to ASTM D 4956-09 Type VI specification for rebound able Retroreflective sheeting. This flexible prismatic sheeting shall beof1ftwidthandlaminatedatthebackwitha50micronAluminum(Al)foilwithpressuresensitive adhesive and liner. Further, this flexible prismatic sheeting shall have screen printed arrow/slant line pattern in black color in a continuous roll format. Neither AFP sheeting nor the flexible prismatic sheeting used in it shall crack when slowly bent in 1 second time around a 1/8th inch mandrel after being conditioned for 24hrs at 0?C and tested as per section S2.2.2. of ASTM D 4956-09. The AFP sheeting, with the liner removed, shall be appliedwitha neoprene contact adhesive witha Polychloroprene as base, viscosity of 200-450 cps and solid content of 20-30%. Once applied, the edges of the product shall be sealed all aroundwith a two-part epoxy based structural adhesive and shall be extremely resistant to peel-off. A test report from institutes like ARAI/CRRI confirming to above mentioned flexibility and ASTM-D4956-09 Type-VI retro reflectivity |
| 49 | Providing and fixing of typical retro reflective MMGSY / PMGSY Project informatory sign board with Logo as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing. The board will be a composite unit consisting of Three Plates ACP (Aluminum Composite Panel), material specificaitons as per clause 17001.3. The top most plate will be of 3mm ACP in diamond shape of 600x600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The middle 4mm ACP plate of will be 1200x150mm size riveted with MS angle iron frame of 25mmx25mmx5mm size on back on edges. The main 4mm ACP lower most plate will be 1500mmx600mm size, riveted with MS angle iron frame of 25mmx25mmx5mm size. Riveting of all the sheets over angle and flat iron frame will be done neatly to have plain surface on one side. The angle iron frame of lower most plate and flat iron frame of the middle plate will be welded to two nos. 75mm x75mm x 12 swg sheet tubes posts placed at 1125mm apart centre to centre. the top of the middle plate will be flushed with the top of 75mm dia medium steel tube posts and these posts will be embeded in cement concrete M15 grade block of 450x450x600mm below ground level. The height of the bottom of the lowerplate will be 1200mm from normal ground level and the bottom of the middle plate will be 100mm above the top level of the lower most plate. the diamond shaped plate mounted over flat angle iron frame will be connected to middle plate by square steel section of 47mmx47mm, thickness 12SWG having a spacing of 100mm between the diamond shaped plate and middle plate and this square section will be riveted to the bottom point of the diamond shaped plate. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-A / Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shall conform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively fortraffic colors. All the section of the frame and posts shall be painted with primer and two coats of epoxy paint. The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.2 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall be submitted by contractor.as directed by Engineer in Charge. |
| 50 | Painting two coats including primer coat after filling the surface with synthetic enamel paint in all shades on new, plastered / concrete surfaces as per drawing and Technical Specification Clause 1701, as directed by Engineer in Charge. |
| 51 | Reinforced cement concrete M15 grade boundary pillars/local stone of standard design as per IRC:25, fixed in position including finishing and lettering but excluding painting as per drawing and Technical Specification Clause 1704, as directed by Engineer in Charge. |
| 52 | Providing and fixing of typical PMGSY Retro Reflective information board as per as per section1700 of MORD specifications and latest PMGSY Signage Manual / Circuler and drawing.Two ACP (Aluminum Composite Panel) sheets of 4 mm thick, of 900 mm x 750mm size fixed at top & bottom duly rivetted with MS angles of 35 x 35 x 5 mm thick M.S angle shall be welded by two vertical M.S angle of 5 mm thick to 75 mm x 75 mm of 12 SWG square tubes / 75mm Dia Pipe posts duly embedded in cement concrete M-15 grade blocks of 600mm x 600mm x 75mm, below ground level. MMGSY / PMGSY logo, letters and numerals on the ACP should be made up of Retro Reflective sheeting of Class-B grade as per the latest MORD section 1700 specifications (Refer Circuler no. NRRDA-P013(11)/3/2019-Dir (Tech) dated 02.12.2019). Printing PMGSY Logo/MMGSY Logo/Project description on Class B type retro reflective sheeting using modern technology printing platform. The printer shall be approved by the retro reflective sheeting manufacturer and printed sign shallconform to retro reflective values as laid down in IRC 67-2022. The inks used for printing shall be eco friendly with VOC emissions complying to UL 2801 standards and specifications for the different kinds of platforms. The printed sign shall be laminated by UV protected laminate and shall carry a warranty of 7 years for Class B sheeting respectively for traffic colors. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy paints as per drawing Clause 1701 and Annexure 1700.1 (10.16).The design, painting and lettering shall be done as per the PMGSY Signage Guidelines Fig.3 and Fig.4 and as directed by Engineer-In-charge. . A warranty for 7 years for the Retro reflective sheeting for Class-B respectively, from original manufacturer shall besubmitted by contractor.as directed by Engineer in Charge. |
| 53 | Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302I) Stone/Boulder as directed by Engineer in Charge. |
| 54 | Providingand laying 0.90 meter thick metal mat consisting of rubble, oversize metal and normal size metal in specifiedthicknessasperdetaileddrawingincludingsupplyingallmaterials,handpackingofrubble, spreading metal in layers and hard murum including watering and compaction with power roller etc. complete.as directed by Engineer in Charge. |
| 55 | Supplying andFixing of Molded Shank RaisedPavement Markers / Cat\"s Eyemade of polycarbonate and ABSmouldedbodyandreflectivepanelswithmicroprismaticlenscapableofprovidingtotalinternal reflectionofthelightenteringthelensfaceandshallsupportaloadof16000kg testedinaccordanceto ASTM D 4280 TypeH and complyingtoSpecificationsofCategoryA ofMORTH CircularNo RW/NH/33023/10-97DO III Dt 11.06. 1997. The height, width and length shall not exceed 50 mm, 100 mm and 102 +/- 2 mm and with minimum reflective area of 13 Sqcm on each side and the slope to the base shall be 35 +/- 5 degree. The strength of detachment of the integrated cylindrical shanks, (of diameter not less than 19 +/- 2 mm and height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 Kg. Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturer\"s recommendation and complete as directed by the engineer.The contractor shall submitatwoyearwarranty forsatisfactoryfieldperformanceincludingstipulatedretro-reflectanceofthe reflecting panel, to the Engineer. as directed by Engineer in Charge. |
| 56 | Providing and Laying hot applied thermoplastic road marking strip on Bituminous Surface of specified shade/ colour of 2.5 mm thick including 1.5 Refractive index reflectorizing glass beads @ 250gm/sqm .Thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC 35:2015. Initial Dry reflectivity RL shall be > 250 mcd/sqm/lux measured in the initial 7 days and sustained reflectivity RL of 100 mcd/sqm/ lux and Qd of 100 mcd/sqm/ lux measured at the end of 2 years by means of a Standard Reflectometer of Zehntner, Easylux, Delta make capable of measuring RL & QD both according to IRC 35:2015 clause 15.5. The finished surface to be level, uniform, and free from streaks and holes complete as per direction of Engineer-in-charge and in accordance with applicable specifications.(Refer MORTH Clause 803 for technical Specification and Performance for IRC 35:2015). as directed by Engineer in Charge. |
| 57 | Metal Beam CrashBarrier -- Type - A, W : Metal Beam CrashBarrier (Providing and erecting a W metal beam crashbarriercomprisingof3mm thickcorrugatedsheetmetalbeam rail,70cm aboveroad/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367andIS:1364, metal beam rail to be fixed on the vertical post witha spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 810)\"\".as directed by Engineer in Charge. |
| 58 | Providing white and colour washing to road side trees in 2 coats in 2 bandsofwhiteandoneredbandatcentreof30cmheighteach including preparing the surface, cost of material, conveying etc. complete. as directed by Engineer in Charge. |
| 59 | Providing and fixing reflective fluorescent tape on old road sign board including cleaning / scraping and paintingexisting board etc. complete as directed by Engineer in Charge. |