Tender For Construction Of Type 4  G Plus 3 Residential Quarters For Revenue Departments Officers Near Civil Lines Besides Lokpriya Hospital In District Ayodhya - Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m for all lift, as directed by E-I-C.All kind of soil.  2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed by Engineer-in-charge.Hard Rock ( Required Blasting )  3 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.  4 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete.  5 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)  6 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diaMetre holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration  7 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.  8 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)  9 Applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.  10 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete  11 Thermo-Mechanically Treated bars work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage.  12 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting All works upto plinth level.Concrete of M30 grade with minimum cement content of 350 kg /cum  13 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources)  14 Add for using extra cement in the items of design mix over and above the specified cement content therein.  15 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).  16 Brick Work with common burnt clay F.P.S (non modular) brick of class designation 7.5 in foundation and plint in : Cement mortar 1:6 (1 cement : 6 coarse sand)  17 15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement : 4 coarse sand)  18 Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.  19 Suspended floors, roofs, landings, balconies and access platform  20 Lintels, beams, plinth beams, girders, bressumers and cantilevers  21 Columns, Pillars, Piers, Abutments, Posts and Struts  22 Stairs, (excluding landings) except spiral-staircases  23 Edges of slabs and breaks in floors and walls Under 20 cm wide  24 Thermo-Mechanically Treated bars work such as in reinforced concreted or reinforced brick work (when not included in overall rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage.  25 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; All works above plinth level upto floor V level. Concrete of M30 grade with minimum cement content of 350 kg /cum  26 Brick Work with common burnt clay F.P.S (non modular) brick of class designation 7.5 in super structure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)  27 Half Brick masonary with common burnt clay F.P.S (non modular) brick of class designation 7.5 in super structure above plinth level up to floor V level Cement mortar 1:4 (1 cement : 4 coarse sand)  28 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)  29 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 9.127.2 - Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws  30 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat . Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.  31 Providing and fixing to existing door frames. 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames.  32 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).  33 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.  34 Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge  35 Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.9.147.A4.1 Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (25 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height upto 1.2 metre).  36 Providing and fixing wire gauge shutters using stainless steel grade 304wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws : 35mm thick shutter With ISI marked stainless steel butt hinges of required size Second class teak wood  37 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding  38 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works  39 R.c.c. workwith cement approved coarse sandand2cm. (3/4) guageapprovedstoneballastin the proportion 1:6,(1 cement :6 aggregate) in lintels of doorsand windows excludingsupply of reinforcement and its fixing and binding the same with 24 B WG bindingwireand  40 Brick koba treatment on roofs.  41 Supply and fixingof flushdoors commercialqualityconformingtoI.S. 2202 Part I (1983) includingfixingofwoodencleats andstoppers and including ixing andadjustment of hinges, bolts,locks, handle, springsfour double leaf shutters addextra (a) 35 mm thick  42 Mild steel or iron workofsmall sizes and sections suchas holding down bolts, holdfasttierods,gratings etc. ( when notincludedinan overall rates) wroughttorequiredfromincluding supply ofsteel anditswastage includingcostof bolts, nuts if required forandwelding, grinding and Fabrication of grill / staircase  43 Fabrication of Z-section steel windows.  44 Angle iron door chaukhats (35x35x5)  45 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover  46 Providing and fixing ball bearing for rolling shutters.  47 Providing and fixing bright /matt finished Stainless Steel sliding door bolt of approved quality & make with necessary screws etc all complete. 250x16 mm  48 Item same item no-47 size 250x10 mm  49 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125mm  50 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of Nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate  51 Cement plaster skirting (up to 30 cm height) with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement. 18 mm thick.  52 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster  53 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws : 35 mm thick shutters With ISI marked stainless steel butt hinges of required size Second class teak wood  54 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces  55 Providing and fixing stainless steel (Grade 304) railing made of hallow tubes, chanells, plates etc. including welding grinding buffing, polising and making corvechare (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in charge.(for payment purpose only weight of stainless steel members shall be considered excluding fixing assessories such as nuts, bolts, fasteners etc.  56 Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete : 20 mm dia  57 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.  58 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.  59 Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). 18 mm thick  60 Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge.  61 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.  62 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.  63 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Double charge vitrified tile polished finish of size of Tile 600 x 600 mm  64 Glazed Vitrified tiles Matt/Antiskid finish of size of Tile 600 x 600 mm  65 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent  66 Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edge to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm  67 Providing and laying tactile tile (PAVIT TILES) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.  68 12 mm cement plaster : 1:6 (1 cement : 6 coarse sand)  69 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement : 6 coarse sand)  70 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) In Ceiling  71 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre  72 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)  73 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture)  74 Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture  75 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 Nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)  76 French spirit polishing : Two or more coats on new works including a coat of wood filler  77 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.  78 Making grooves 10 to 12 mm wide x 8 mm deep in plaster the all or in ceiling vertically of horizontally as required.  79 Add for plaster drip course in plastered surface or moulding to R.C.C. projections.  80 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to Nos other with bitumen @ 1.7 kg/sqm).  81 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: A-Applying a slurry coat of neat D-Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. E-The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :  82 Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.  83 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand).  84 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm,finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of periMetre channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum moisture resistant board  85 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests  86 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid  87 Providingandfixing wash basin with C.I.brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting andmaking good the walls where required :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps  88 Providing and fixing Salem Stainless Steel A ISI 304 (18/8) kitchen sink as per IS: 13983 with CI brackets and stainless steel waste with plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required.Sink with drain board 510x1040 mm bowl depth 200 mm  89 Item same as item no 88 but Sink without drain board 610X510 mm bowl depth 200mm.  90 Providing & fixing PVC waste pipe for sink oncluding PVC waste fitting Complete. Flexible Pipe32mm Dia  91 Item same as item no 90 but pipe40mm Dia  92 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Circular shape 450 mm dia  93 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete.  94 Providing and fixing toilet paper holder : C.P. brass  95 Providing and fixing soil, waste, vent pipesCentrifugally cast (spun) iron S&S pipe 100mm dia cast (spun) iron S&S pipe  96 Providing and fixing MS holder bat clamps of approved design to cast iron (spun) pipe embedded in and Including cement concrete blocks 10 x10 x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. For 100mm dia. Pipe  97 Providing and fixing heel rest sanitary bend, in Centrifugally cast (spun) iron pipe S&S100mm  98 Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete. 100X100X100mm Sand cast iron S&S as per IS : 3989  99 Providing and fixingPLAIN JUNCTIONof required degree100X100X100mm Sand cast iron S&S as per IS : 3989  100 Providing and fixing terminal guard: 100mm Sand cast iron S&S as per IS - 3989  101 Providing and fixing collar. 100mm Sand cast iron S&S as per IS - 3989  102 Providing and lead caulked joint100 Dia  103 Providing and fixingcast iron trap of self cleansing design withcast iron screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors. 100 mm inlet and 100 mm outlet,Sand cast iron S&S as per IS: 3989  104 Painting sand cast iron / centrifugally cast iron( spun) iron soil, waste and vent pipes and fittings with paint of any colour such as chocolate, grey or buff etc. over a coat of primer (of approval quality) for new work 100mm dia  105 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms.  106 Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms  107 Providing and fixing PTMT towel rail complete with brackets fixed wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms  108 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of15 mm dia nominal bore  109 Item same as item no 108 but pipe 20 mm dia nominal bore  110 Item same as item no 108 but pipe 25 mm dia nominal bore  111 Item same as item no 108 but pipe 32 mm dia nominal bore  112 Item same as item no 108 but pipe 40 mm dia nominal bore  113 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes15 mm nominal outer dia pipes  114 Item same as item no 113 but pipes20 mm nominal outer dia pipes  115 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trench 50 mm dia, nominal bore  116 Item same as item no 115 but pipes trench 65 mm dia, nominal bore  117 Item same as item no 115 but pipes trench 80 mm dia, nominal bore  118 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 25mm dia, nominal bore  119 Item same as item no 118 but pipes 32 mm dia, nominal bore  120 Item same as item no 118 but pipes40 mm dia, nominal bore  121 Item same as item no 118 but pipes 50 mm dia, nominal bore  122 Item same as item no 118 but pipes 65 mm dia, nominal bore  123 Item same as item no 118 but pipes 80 mm dia, nominal bore  124 Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length15 mm nominal bore  125 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet100 mm diaMetre  126 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore  127 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore  128 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore.  129 Providing and fixing PTMT grating of approved quality and colour. Circular type 100 mm nominal dia  130 Excavating trenches of required width for pipes, cables, etc, including excavation for sockets, depth upto 1.5 m including getting out the excavated materials, returning the soil as required in layers not exceeding 20 cm in depth including consolidating Nos deposited layers by ramming, watering etc. stacking serviceable material for measurements and disposal of unserviceable material as directed, within a lead of 50m : Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia.  131 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 150 mm diaMetre  132 Item same as item no 131 but pipes : 200 mm dia Metre  133 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :150 mm diaMetre S.W. pipe  134 Item same as item no 133 but pipes200 mm diaMetre S.W. pipe  135 Item same as item no 133 but pipes :200 mm diaMetre S.W. pipe  136 Providing and fixing square-mouth S.W. gully trap grade A’ complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than With F.P.S. Bricks class designation 75 100x100 mm size P type  137 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm dia rcc pipe  138 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 grade Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With F.P.S. bricks with class designation 150  139 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar  140 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 grade Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diaMetre, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5  141 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.  142 Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & attern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturers specifications & direction of Engineerin- Charge. 80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern.  143 Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the requireddensity .  144 Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Note:- Cement content considered in M-30 is @ 340 kg/CUM Excess/less cement used as per design mix is payable/ recoverable separately.  145 Providing and fixing in position pre-moulded joint filler in expansion joints.  146 Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound.  147 Providing and laying Kerb Stone 600 c/c  148 Providing & Filling of O.B. brick ballast 25 mm to 40 mm size inside of upper layer in soak pit.  149 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia  150 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia  151 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 200 mm nominal size dia  152 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.  153 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge.  154 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.  155 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge.  156 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge.  157 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia  158 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia  159 Drain work Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating Nos deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: all kind soil Pipe, cables etc exceeding 80 mm dia but not exceeding 300 dia  160 Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe  161 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5  162 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5  163 Providing and injecting chemical emulsion for preconstructional chemical barrier underand alroundthe column pits wall trenches basement excavation top surface if plinth filling junctionofwall and floor, alongthe  164 20 mmthickcementplasterindado/ skirting in 1:3consistingof onepartof cement and 3 partsof aprovedcoarsesand laid inpanels,finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 including supply of  165 Fixingpanesofglasswithatul orequivalent I.S.I. marked quality putty,brads and springs complete. (a) 4 mm thick  166 Providing Oxidised iron sliding bolts16 mm dia with nuts and 250 mm long.(analysed) (ii) Oxidised iron  167 Providing and fixing of 8 PVC casing pipe of ISI mark.  168 Providing and fixing ofP/ F 3 GI pipe (B) class.  169 Providing and fixing ofNylon mesh for filter.  170 Providing and fixing ofPlastic dori.  171 Providing and fixing ofSolvent cement.  172 Providing and fixing of8 End cap.  173 Providing and fixing of8 Submersible cap.  174 Providing and fixing of3 MS clamp (Heavy).  175 Providing and fixing of3 GI elbow.  176 Providing and fixing of3 X 6 GI nipple.  177 Providing and fixing of7.5 HP 9 Stage submersible pump of ISI mark with automatic panel.  178 Providing and fixing of4.00 sqm. Submersible cable.  179 Providing and fixing ofDrilling charges for16 dia tubewell.  180 Providing and fixing ofPea Gravel.  181 Providing and fixing of2 MS socket.  182 Providing and fixing ofRope with plastic coated  183 Providing and fixing of C.I. Pipe (100 mm dia)(DSR 17.35.1.2)  184 Providing and fixing of C.I. Pipe (50 mm dia)(DSR 17.35.1.2)  185 Providing and fixing ofC.I.cowel. (DSR 17.56.1.2)  186 500 mm diaMetre C.I. cover (medium duty) the weight of the cover to be not less than 58 kg (DSR 19.18.2)  187 Sub-Head : WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A  188 Item same as item no 187 butGroup B type  189 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.  190 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X2.5 sq. mm + 1X2.5 sq. mm earth wire  191 Item same as item no 190 but 2 X 4 sq. mm + 1 X 4 sq. mm earth wire  192 Item same as item no 190 but 2 X 6 sq. mm + 1 X 6 sq. mm earth wire  193 Item same as item no 190 but 4 X 6 sq. mm + 2 X 6 sq. mm earth wire  194 Item same as item no 190 but 2X 16 sq. mm + 1 X 6 sq. mm earth wire  195 Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire  196 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.  197 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm  198 Item same as item no 197 but32 mm  199 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 pair  200 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.  201 Supplying and fixing extra down rod of 10 cm length G.l. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)  202 Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required.  203 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch  204 Item same as item no 203 but 15/16 A switch  205 Item same as item no 203 but 3 pin 5/6 A socket outlet  206 Item same as item no 203 but 6 pin 15/16 A socket outlet  207 Providing and fixing of Telephone socket outlet  208 Providing and fixing ofTV antenna socket outlet  209 Providing and fixing ofBell push  210 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.  211 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.  212 Supplying and fixing following size/ modules, Gl box along with modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module (75mmX75mm)  213 Item same as item no 212 but 3 Module (100mmX75mm)  214 Item same as item no 212 but 6 Module (200mmX75mm)  215 Supplying and fixing call bell/ buzzer suitable for single phase, V, complete as required.  216 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.  217 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Up to 450 mm sweep  218 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.  219 Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required.  220 Supplying and fixing PVC batten/ angle holder including connections etc. as required.  221 Sub-Head : MCCB, MCB & OBS Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.100 A.30KA.FPMCCB  222 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator)4 way (4 + 12), Double door  223 Item same as item no 222 but 8 way (4 + 24), Double door  224 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)4 way (4 + 12), Double door  225 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole  226 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.  227 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A  228 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 A  229 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.  230 Sub-Head : EARTHING Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.  231 Supplying and laying 6 SWG G.l. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with Gl thimble etc. as required.  232 Supplying and laying 25 mm X 5 mm G.l. strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.l. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.l. nut bolt & spring washer spaced at 50mm)  233 Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required.  234 Providing and fixing 6 SWG dia G.l. wire on surface or in recess for loop earthing as required.  235 Sub-Head : MV CABLE JOINTING & END TERMINATION Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3-1/2X 25 sq.mm  236 Item same as item no 235 but 3-1/2 X 35 sq.mm  237 Item same as item no 235 but 3-1/2 X 95 sq.mm  238 Item same as item no 235 but 3-1/2 X 120 sq. mm  239 Item same as item no 235 but 3-1/2 X 185 sq. mm  240 Item same as item no 235 but 4 X 16 sq. mm (28mm)  241 Sub-Head : MISC. CIVIL ITEMS Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.(DSR Civil 2023 Item Nos 10.18.)  242 Sub-Head : Ceiling Fan with BLDC MotorSupply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 Nos. blades, 30 cm long down rod, 2 Nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.  243 2160-2400 system lumens,>120 lm/w, PF>.95, THD<10% at full load, CRI>80, >300V over voltage protection,2.5 KV internal Surge protection, with 5 years Warrantee.  244 2620 system lumens,>120 lm/w PF>.95,THD<10%,CRI>80, sheetthickness min 0.8 mm, Tube with aluminum heat sink, >300V over voltage protection,2.5 KV internal Surge protection, with 5 years Warrantee.  245 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having pressure die cast housing with driver set confirming to IP 65 and above Protection,IK 08,High purity/transmisivity UV Stabilized Non yellowish diffuser/reflector for uniform light distribution, detachable driver set,open and short circuit protection suitable for 24 Hrs. continuous operation.Complete in all respect. CAT. - AAA1200 system lumens,>120 lm/w PF>.95,THD<10%,CRI>70,>300V over voltage protection,4 KV internal Surge protection, with 5 years Warrantee.  246 FLOOD LIGHT LUMINAIRE 20400-24000 system lumens, High power LED with lenses,>120 lm/w, PF>.95,THD<10% at full load,CRI>70,Potted driver set in metal housing( not circuitory), phase to phase protection at 440 v, >300V over voltage auto cut and restart feature , 4 KV internal Surge protection, with 5 years Warrantee. CABLE WORKS  247 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top as directed by Engineer-Incharge ,complete in all respect including excavation and refilling.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 95 sq mm 3-1/2 core  248 Item same as item no 247but 400 sq mm 3-1/2 core  249 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at IN Existing RCC/Hume/metal pipe as directed by Engineer-Incharge ,complete in all respect including excavation and refilling.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.6 sq mm 2 core  250 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at IN Existing RCC/Hume/metal pipe as directed by Engineer-Incharge ,complete in all respect including excavation and refilling.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 400 sq mm 3-1/2 core  251 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade on wall surface as directed by Engineer-Incharge ,complete in all respect including excavation and refilling.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 185 sq mm 3-1/2 core  252 Item same as item no 251 but 70 sq mm 3-1/2 core  253 Item same as item no 251 but 95 sq mm 3-1/2 core  254 Item same as item no 251 but 120 sq mm 3-1/2 core  255 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) 12 way , Double door  256 All Incomer Feeder shall be provided with Multifunctional Metreing along with phase Indicating lights and other associated components such as CT control MCB Terminal Blocks etc. and all outgoing Feeders 100 A & above shall be provided with 3 phase AmMetre along with phase Indicating lights and other associates components such as CT control MCB Terminal Blocks etc. The feeder above shall be provided ac accommodated all measuring instrument shall be digital type & all indicating lights shall be LEd type.Wiring shall be done from 1100V Grade PVC Insulated copper flexiblewire all ACB shall be electricaly operated Draw out Type with microprosser based O/L,S/C &E/F Release of Breaking/withstand capacity(ICU/ICs/Icw) 50 kA or more All MCCb shall be thermal magnetics/microprocessor with O/L & S/C protection along with required Spreaders & Extended rotary handle with pad locking facility of breaking capacity 36 kA or more All MCB shall be Thermal 10kA CCurve Cubical type switch board shall be Cat-B Only. Pannel board MCCB Type, No incoming 100 Amp MCCB -1, Outgoing- 63 Amp. MCCB-2 Nos.+ (63 AMP FP MCB-3 Nos.)  257 200 Amp. MCCB-2 Nos,100 Amp MCCB- 1 No, & 63 Amp MCCB-1 No +( 63 AMP FP MCB-5 Nos+100 AMP MCCB-3 Nos.+125 AMP FP MCCB-2 Nos.)  258 Supply of AC 1400mm Sweep, 230/250 Volts, 50 Hz ceilling fan without regulator, standard down rod, blades etc. complete as required. (Standard - Plain Ceiling Fans)  259 Supply of AC 300mm Sweep, 230/250 Volts, 50 Hz exhaustfan (Heavy Duty) withblades,cover etc. complete as required.  260 Supply of AC 200mm Sweep, 230/250 Volts, 50 Hz exhaustfan (Light Duty) withblades,cover etc. complete as required  261 Supply of Factory made 12 to 20 Watt LED Bulb fitting,cool day light,(65000 K temp.) suitable for Batton/Angle holder including makingconnection.Complete in all respect.  262 Supplyof LEDTubeLightwithbatten suitable forupto 1X 10watt LED tube lightfitting includingtubeonSurfacecompleteinallrespect.(2ft)CAT-AAA  263 Supply and fixing of Three phase multifunctional electronic energy Metre 10 to 60 Amp. Capacity fitted in intergral box on wall complete in all respect.  264 Supply Installation , Testing & Commissioning of LIFTS with power operated centre opening doors and AC variable voltage & variable frequency control,car safety & Governor, Guides, guide rails, ropes, car platform, cabin finishes (stainless steel), car & landing doors (stainless steel), hoist motors, braking system, Automatic Rescue Device (ARD) etc. complete as per the CPWD Specifications and realated IS standards upto date. 16 Passenger,1.5 mps,4 stops , 4 Openings including all complete materials and labours  265 Supplying,installation,testing and commissioningof gridinteractiveroof top solar photo voltaic power generation system including space frame Roof top grid interactivesolar photo voltaic plant system shall beinclusiveof the Solarpanelsof prescribedefficiency,mountingstructure,cabling,inverter,panel,Metreing devices, earthing, lightning protection complete as per state-of-the-art technology as per good engineering practice compliant to relevant Indian standards/ local/statutory authorities/MNRE guidelines.;The capacity of plant shallbe derived as per available space on terrace of the buildings; High efficiency PV cells with high efficiency invertors shall be used. Minimum power outputguaranteeofferedfor the SPVModuleshall notbe less than rated for 25 years; Invertors/Power conditioning unit (PCU suitable for mains as well as DG supply) as required. However, capacity of Nos invertor should not be more than 30 Mp; The inverter output shall always follow the grid in terms of voltage and frequency;ACcollectionPanelwithMetreingtomonitorgenerationattheterraceand AC cabling from Panel to receiving switch; Measuring devices i/c net Metreing, indication devices, protection devices, switching devices, all necessary wiring, DC and AC cabling including feeding power to essential supply by providing necessary tap ofi boxes; Mouriting structure of GI on terrace of the building, protection of system for external/internal causes and from all kind of surges etc.; Earthing and Lightning protection of Solar system  266 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.450 lpm at 35 m Head  267 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel  268 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :100 mm dia  269 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.  270 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia  271 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia  272 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Gun Metal  273 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m  274 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as requiredGun metal  275 FIRE EXTINGUISHERS Supply and fixing of fire extinguisher, ABC Type (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket,along with supply of all materials and labour for proper completion of work. 4.0 kg. capacity  276 Supply and fixing of C02 type fire extinguisher (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 4.5 kg. capacity  277 Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts.  278 Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter FIRE in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 5 buckets).  279 Providing and fixing of 1200x900 mm(Indoor Cabinet) Only Frame  280 Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site.  281 Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement.  282 Supplying, installation, testing and commissioning of silent type DG sets, AMF panel, bus ducting/ cablesfrom DGsets to essential panel, synchronizing panel where required, DG set enclosure roomsound insulation/ventilation/smoke exhaustas required, earthingofDG set system,control cabling, fuel tank/piping,DGset exhaustpiping/exhaust chimneyas per CPCB norms, civil works connected with DG sets including foundation as required.  283 Extra for synchronizing panels wherever required As per CPWD General SpecificationforElectrical WorksPart VIIDG Sets — 2013, relevantcode,CPCBnormsandlocalbodynormscoveringDGsets,AMFpanel, bus ducting/ cables from DG sets to essential panel, DG set enclosureroom sound insulation/veritilation/ smokeexhaustasrequired,earthingofDGsetsystem, control cabling, fuel tank/ piping,DGset exhaustpiping/ exhaust chimneyas per CPCB norms, civil works connected with DG sets including foundation as required. DG sets shall be silent type, minimum rating/ capacity specified is nominal capacity at standard test conditions; TheDG set capacityshall besuitable for the loadcovering commonarea lighting, outdoorlighting, lifts,watersupply pumps, sewerage and drainage pumps, firefightingessentialsandotheressentialpowersupplyrequirementsas persite requirements. Theengine shall be capableof driving thealternator continuously at its ratedfull load and rated speed withoutgetting over loadedunder theprevailingoperating conditions. Generator Sets shall be 415V, 3 Phase, 4 wire, 50Hz, 0.8 PF with acoustic enclosure.Generator sets shall startautomaticallyin the event of a power failure and shall transfer power to emergency /critical loads automatically and shall switch off after some time delay in case of restoration of power supply. Synchronisation arrangement to be provided in case of parallel operations, where more than 1 DG set is installed and such arrangement is required as per site requirement. As per CPWD General SpecificationforElectrical WorksPart VIIDG Sets — 2013, relevant codes and CPCB/ local body norms.  284 Supply & fixing of 12.5 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out sidedip,heavingpolesheetthickness3mm.Topdia minimum 150 mm, Bottom dia 310 mmbase plate 25 mm thicksuitable forwindvelocity asperIS 875part 3& havingnocircumferentialweld,withaccessoriesfor high mast such as head frame suitable for 6 luminaries & its control gear boxes 0.75 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drumwinch,includingmakingsuitablefoundationas per manufature drawing/ site reuiment along withfoundation bolts nuts,washers,anchor plates etc completee in all respect.  285 Supplyandfixingfollowingcapacityofautomatic streetlightcubiclecontrolpanelpaintedwithanti corrosivealkaliandacidproofpaintconsistingof timeswitchTSO100serieswithcontactors,HRC fuses,isolating switch meteringinstrument& instrument box with CTs etc. incase of TPN, complete in all respect. 15 A TPN  286 Supply and fixing of LED Street light Fitting with mandatory driver set having die cast aluminium body with toughend glass/UV stabilised PC cover and lenses suitable for 160 watt to 175 watt and Confirming to IP 66 and IK 07 and above Protection, complete having company logo engraved complete in all respect including labour . CAT AAA 19200-21000 system lumens, High power LED with lenses,>120 lm/w, PF>.95,THD<10% at full load,CRI>70,Potted driver set in metal housing( not circuitory), phase to phase protection at 440 v, >300V over voltage auto cut and restart feature , 4 KV internal Surge protection, with 5 years Warrantee.  287 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top as directed by Engineer-Incharge ,complete in all respect including excavation and refilling.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.120 sq mm 3-1/2 core  288 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at IN Existing RCC/Hume/metal pipe as directed by Engineer-Incharge ,complete in all respect including excavation and refilling.The armouring of the cable shall be properly connected with the earth conductor by clamps etc.10 sq mm 4 core  289 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 X 10 sq. mm (22mm)  290 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3-1/2 X 120 sq. mm (45mm)  291 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly leveling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure).  292 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment).  293 Supply and stacking of Grevillea robusta (Silver Oak) plant of height 150- 165 cm. in big poly bags of size 25 cm as per direction of the officer-incharge.  294 Supply and stacking of Plumeria acutifolia plant of height 150-165 cm. with 3-4 branches in big size HDPE bag as per direction of the officer-in-charge  295 Supply and stacking of Chorisia speciosa plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.  296 Supply and stacking of Polyalthia pendula (Ashok Pendula) plant of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-incharge.  297 Supply and stacking of Azadirachta indica ( Neem ) plant of height 120- 130cm in big polybag of size 25 cm as per direction of the officer-in-charge.  298 Supply and stacking of Polyalthia longifolia (Ashok) plant of height 180- 195 cm. in gunny bag of size 30 cm as per direction of the officer-incharge.  299 Supply and stacking of Bauhinia blakeana (Kachnar) plant of height 120- 150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.  300 Flowering & Indoor Potted Plants in 10 earthern Pots