PROVN OF TOILET BLOCK AT CC-158 (HC WING) AT ARMY WAR COLLEGE, REPAIR/MAINT/IMPROVEMENT OF RAINWATER DRAINS AROUND HC MD ACCN BLOCK NO-95 TO 104 AND PROVN OF TWO GARBAGE PIT AT OR MESS AND MD ACCN VINDHYA VIHAR OF DEMO SQN 81 ARMD REGT UNDER GE (AWC) MHOW; 1 M&L for Excavating in trenches in soft/ loose soil, not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation, n exc 10 sqm in plan and getting out complete all as specified and directed. 2 M&L for Excavating in trenches in soft/ loose soil, exceeding 1.5m wide and not exceeding 3.00 m in depth for foundation, n exc 10 sqm in plan and getting out complete all as specified and directed. 3 M&L for Cement concrete Type D-2, 1:4:8 (40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. 4 M&L forReinforced cement concrete (Design mix) M-30 (using 20 mm graded stone aggregates) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 5 M&L forReinforced cement concrete (Design mix) M-30 (using 20 mm graded stone aggregates) as in Columns, pillars, piers, posts and struts complete all as specified and directed. 6 M&L forReinforced cement concrete (Design mix) M-30 (using 20 mm graded stone aggregates) as in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. 7 M&L forReinforced cement concrete (Design mix) M-30 (using 20 mm graded stone aggregates) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. 8 M&L forReinforced cement concrete (Design mix) M-30 (using 20 mm graded stone aggregates) as in chajja and the like complete all as specified and directed. 9 M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raftbeams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, Flat, with fair finished surfaces complete all as specified and directed. 10 M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions (sqaure, rectangular or polygon) with fair finished surfaces complete all as specified and directed. 11 M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. Flat, with fair finished surfaces complete all as specified and directed. 12 M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) Flat, with fair finished surfaces complete all as specified and directed. 13 M&L Mild Steel TMT bar 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire not less than 0.90mm dia or securing with clips complete all as specified and directed.Note :- (a) The rates include for fixing and for bracing, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it. Rates also include for straightening where reinforcement is supplied in rolls/coils. 14 M&L for Mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as speified and directed. Note :- (a) The rates include for fixing and for bracing, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it. Rates also include for straightening where reinforcement is supplied in rolls/coils. 15 M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as speified and directed. Note :- (a) The rates include for fixing and for bracing, supporting or otherwise holding firmly in position so that the placing and ramming of concrete will not displace it. Rates also include for straightening where reinforcement is supplied in rolls/coils. 16 M&L for Returning, filing in, including spreading, levelling, watering and well rammingin layers not exceeding 25 cm in any type of soil etc complete all as specified and directed 17 M&L for Removing excavated material (Soil) exc. 250 m but n exc. 500 m and depositing where directed complete all as specified and directed. 18 M&L Modular Brick work with Fly Ash bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. Note:-(a) Fly ash bricks shall be burnt clay flyash building bricks as per IS- 13757.(b) The rates for work curved or polygonal on plan include for all extra cutting and extra waste in the body of the work. It shall be measured as mean length of wall.(c) Rates are for bricks of class designation 75 (Kgf/cm2). 19 M&L Modular Brick work withFly Ash bricks bricks straight or curved on plan any radius in half brick thick walls, built in CM 1:4 complete all as specified and directed.Note:- (a) Fly ash bricks shall be burnt clay flyash building bricks as per IS- 13757.(b) The rates for work curved or polygonal on plan include for all extra cutting and extra waste in the body of the work. It shall be measured as mean length of wall.(c) Rates are for bricks of class designation 75 (Kgf/cm2). 20 M&L for joint free non skid ceramic colouredtiles 7 to 8 mm thick(square / rectangular) area of each tile exc 0.11 sqm and not exceeding 0.18 sqm in floors etc set & jointed in neat cement slurry and pointed with white or coloured cement to match with the shade of tiles as approved complete all as specified and directed. Note :- (a) The rates are exclusive of bedding layer or screeded surface but include for setting and jointing the tiles in cement paste or slurry.(b) The rates include for all straight cutting and waste. Raking or circular cutting and waste shall be measured separately. 21 M&L for 100 mm thick cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as sub base of floor complete all as specified and directed. Note :-The rates of cement concrete in flooring include for:(i) Use and waste of form work/screed strips and to divide the area in panels. (ii) Finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, sub-bases, etc.even and rough to receive the topping layer.(iii) Finishing exposed edges fair or rounding or chamfering of exposed edges, where directed.(iv) Laying concrete in narrow widths, risers, treads, landings and the like. 22 M&L for hard core of gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed. 23 M&Lfor PCC 1:2:4type B-0using 12.50 mm graded stone aggregate as in sub-base flooring25 mm thick surface finishedeven and rough to receive the topping layer complete all as specified and directed. Note :- The rates of cement concrete in flooring include for:(i) Use and waste of form work/screed strips and to divide the area in panels. (ii) Finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, sub-bases, etc.even and rough to receive the topping layer.(iii) Finishing exposed edges fair or rounding or chamfering of exposed edges, where directed.(iv) Laying concrete in narrow widths, risers, treads, landings and the like. 24 M&L for 16 mm thick granite slab (of any type) work(table rubbed and polished) in cooking platforms, steps, window cills, incl edge moulding & cutting holes for gas pipe through drill machine and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. 25 M&L for Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed. 26 M&L for Glazed ceramics coloured tiles of size 350x250x7 mm/ 450x350x7mm thick in vertical surfaces such as skirting/dados/risers to steps etc, jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tiles complete all as specified and directed. Note:- (a) The rates are exclusive of bedding layer or screeded surface but include for setting and jointing the tiles in cement paste or slurry.(b) The rates include for all straight cutting and waste. Raking or circular cutting and waste shall be measured separately.(c) The rates for glazed tiles and terrazzo tiles include for laying to any pattern with one or more colours as directed.(d) The rates for cement concrete and terrazzo tile include for cutting and polishing.(e) If tiles of different sizes are used then no price adjustment shall be done. 27 M&L for Rendering 10 mm thick in cement mortar 1 : 4for fixing of wall tiles complete all as specified and directed.Note:-The Rates includes for(a) Thickness of plaster key in joints, etc.(b) Arrises, chamfers of any width, internal rounded angles upto 80mm in width or girth external rounded angles upto 80mm in width or girth, except in thecase of mud plaster and leeping where angles etc. of any girth are included.(c) All labour and equipment necessary for incorporating integral waterproofing compound in the manner specified by the manufacturer and in the proportionsindicated. The rates do not include for supply of integral waterproofing compound, which if supplied by the Contractor, shall be measured separately and paid for at “Supplied only rates.(d) Scoring surface of plastering for key, where the surface is not required to be finished fair.(e) Curing of plastered surface.(f) Cleaning stains and dripping mortar from floors and walls, etc. 28 M&L 75 mm thick PCC 1:3:6 type C-1 using 20mm graded aggregate as in plinth protectionfinishing even & smooth without using extra cement laid in bays with construction, 6mm thick joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 gde and three part of sand ( all by weight) complete all as specified and directed. Note :- The rates of cement concrete in flooring include for:(i) Use and waste of form work/screed strips and to divide the area in panels. (ii) Finishing surfaces of concrete topping even and fair (without using extra cement), and finishing surfaces of concrete in sub-floors, sub-bases, etc.even and rough to receive the topping layer.(iii) Finishing exposed edges fair or rounding or chamfering of exposed edges, where directed.(iv) Laying concrete in narrow widths, risers, treads, landings and the like. 29 M&L Rendering on fair faces of brick work or concrete surfaces of wall 15 mm thickin CM 1:6 and to be finished even and smooth without using extra cement complete all as specified and directed.Note :-The Rates includes for (a) Thickness of plaster key in joints, etc.(b) Arrises, chamfers of any width, internal rounded angles upto 80mm in width or girth external rounded angles upto 80mm in width or girth, except in thecase of mud plaster and leeping where angles etc. of any girth are included.(c) Scoring surface of plastering for key, where the surface is not required to be finished fair.(d) Curing of plastered surface.(e) Cleaning stains and dripping mortar from floors and walls, etc. 30 M&L Rendering 15 mm thick in cement mortar 1:4, in two layers (1st layer 10 mm thick rendering coat and 2nd layer 5 mm thick finishing coat) on brick work or concrete surfaces,second layer (finishing coat)mixed with liquid water proofing compound @ 200 ml / 50 Kg bag of cement as per manufacturers instructions and finish the surfaces even and smooth without using extra cement complete all as specified and directed.Note (i):-(a) Liquid WPC will be measured and paid separately.Note(ii) :-The Rates includes for (a) Thickness of plaster key in joints, etc.(b) Arrises, chamfers of any width, internal rounded angles upto 80mm in width or girth external rounded angles upto 80mm in width or girth, except in thecase of mud plaster and leeping where angles etc. of any girth are included.(c) All labour and equipment necessary for incorporating integral waterproofing compound in the manner specified by the manufacturer and in the proportionsindicated. The rates do not include for supply of integral waterproofing compound, which if supplied by the Contractor, shall be measured separately and paid for at “Supplied only rates.(d) Scoring surface of plastering for key, where the surface is not required to be finished fair.(e) Curing of plastered surface.(f) Cleaning stains and dripping mortar from floors and walls, etc.(g) Use of all scaffolding, trestles, ladders, cradles, etc. necessary for execution of work and protective measures. 31 M&L Rendering 5 mm thick in cement mortar 1:3 on concrete surfaces of ceiling and finishing the surfaces even and smooth complete all as specified and directed. Note :-The Rates includes for (a) Thickness of plaster key in joints, etc.(b) Arrises, chamfers of any width, internal rounded angles upto 80mm in width or girth external rounded angles upto 80mm in width or girth, except in thecase of mud plaster and leeping where angles etc. of any girth are included.(c) Scoring surface of plastering for key, where the surface is not required to be finished fair.(d) Curing of plastered surface.(e) Cleaning stains and dripping mortar from floors and walls, etc. 32 Supply only water proofing compound (liquid), ISI marked complete all as specified and directed.Note : - Providing & applying one coat of Dr. Fixit Epoxy Bonding Agent Solvent free epoxy resin-based bonding agent or equivalent . Overlay of concrete / mortar must be placed on Dr. Fixit Epoxy Bonding Agent or equivalent when it is tacky. 33 M & L for preparation of newly plastered surfaces ofwall & concrete and applying 2 mm thick wall care putty in two layers including preparation complete all as specified and directed. 34 M&L for applying two coats of oil bound distemper on wall or concrete over a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. 35 M & L for preparation of newly plastered surfaces ofceiling and applying 2 mm thick wall care putty including preparation of new surface complete all as specified and directed. 36 M&L for applying two coats of oil bound distemper on ceiling over a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed. 37 Material & Labour for applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified and directed. 38 Providing and fixing factory made uPVC white colour fixed / louvered ventilator made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x 58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket. 1.2 +–0.2mm thick, galvanized steel Frame (28mm x 21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners 5mm thick glazing with selected quality glass (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories Net opening will be measured for payment purpose.)(A) Area not exceeding 1.00 sqm each. 39 S&F 5 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and directed.Note : The Glass may be transparent or tinted as as directed. 40 S&F Mild steel framed works such as grills,gratings,etc, with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work for portions framed and hung as gates, including pintle hinges, stops, hand made sliding bolts, etc conforming to Fe 290 Gde -E-165 complete all as specified and directed.Note :-The rates include for riveting and/or welding as directed and fixing with screws, bolts, etc. complete 41 Providing and fixing factory made uPVC white colour casement (Openable) Door made of extruded profile wilh wall thickness of 2.3mm ( + -0.2mm). Window profile with hollow section with mitlti chamber, frame (60mm x 58mm), sash (60mm x 78mm). T profile (One vertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x 20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket 1.2 + -0.2mm thick galvanized steel Frame (28mm x 21.5mm), sash (31mm x 27mm), T-profile (27mm x 17mm) to be inserted in required profile, frame will be fixed to the wall wilh 8mm x 100mm long fasteners. Hardware: casement door handle made of zinc alloyed (white powder coated). Corner striker. Secondary Strikers. Cylinder. Door transmission gear made of mild sleel with multi point locking system with strikes. 3D Hinges of zinc alloyed (white powder coated) and 5mm thick glazing with selected quality glass. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose.) 42 S&F Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed. 43 S&F in repairs MS Peg set for Hat and coat hooks, solid body, 175mm to 250 mm complete all as specified and directed. 44 M&L Cutting chases in brick walls/ stone masonary walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed. 45 Supplying and laying of CPVC pipes with outer dia 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. 46 Supplying and laying of CPVC pipes with outer dia 25 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed. 47 S&F Brass Elbow for CPVC Pipes with outer dia 20 mm complete all as specified and directed. 48 S&F Brass Elbow for CPVC Pipes with outer dia 25 mm complete all as specified and directed. 49 S&F Brass Elbow Rd (3/4 X ½) for CPVC Pipes with outer dia 20 mm complete all as specified and directed. 50 S&F Brass Teefor CPVC Pipes with outer dia 20 mm complete all as specified and directed. 51 S&F Brass Teefor CPVC Pipes with outer dia 25 mm complete all as specified and directed. 52 S&F Male Brass Threaded Adaptor (MTA/ MBTA)for CPVC Pipes with outer dia 20 mm complete all as specified and directed. 53 S&F Male Brass Threaded Adaptor (MTA/ MBTA)for CPVC Pipes with outer dia 25 mm complete all as specified and directed. 54 S&F Female Brass Threaded Adaptor (FTA/ FBTA)for CPVC Pipes with outer dia 20 mm complete all as specified and directed. 55 S&F Female Brass Threaded Adaptor (FTA/ FBTA)for CPVC Pipes with outer dia 25 mm complete all as specified and directed. 56 S&F Tank Adaptorfor CPVC Pipes with outer dia 20 mm complete all as specified and directed. 57 S&F Tank Adaptorfor CPVC Pipes with outer dia 25 mm complete all as specified and directed. 58 S&F Union for CPVC Pipes with outer dia 20 mm complete all as specified and directed. 59 S&F Union for CPVC Pipes with outer dia 25 mm complete all as specified and directed. 60 S&F Ball Valves for CPVC Pipes with outer dia 25 mm complete all as specified and directed. 61 S&F 15 mm bore chromium plated central hole basin mixer single lever without popup waste system with 450 mm long braided hoses complete all as specified and directed 62 S&F Vitreous China wash basin, angle back (counter-type) , size 600x480mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets with two coats of synthetic enamel painting over a coat of red oxide primer etc complete all as specified and directed. 63 S&F LDPE pipe 50mm of pressure rating 6Kgf/sqcm fixed complete to walls, ceilings or in floors etc complete all as specified and directed. 64 S&F Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessorieslike rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) complete in all respect all as specified complete all as specified and as directed. 65 S&F 10 Ltr capacity PVC valveless shyphonic action type low level flushing cistern white with inlet, ball valve, float valve and handle incl bracket and flush pipe of low level of 32mm dia fixed to wall complete all as specified and directed. 66 S & FHealth faucet (ABS Body) mild steel pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. 67 S&F PVC connection 15mm dia size with PTMT nuts and 450 mm long complete all as specified and as directed. 68 S&F Looking Mirror 5.5 mm thick of selected quality glass of size 600 x 450 mm bevelled edge, mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screw and cup washers including aluminium anodized frame complete as specified and directed. 69 S&F Bib taps 15 mm bore, fancy type, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed 70 S&F Brass chromium plated tubular towel rail 20 mm dia, D type, 60 cm long between flanges complete all as specified and directed. 71 S&F Angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe complete all as specified and directed. 72 S&F Soap dish, vitreous China white, approximate size 160x 160 x 90 mm complete all as specified and directed. 73 S & F Toilet paper holder with flat recessed type stainless steel complete all as specified and directed. 74 S&F Plastic water closet seat cover, ivory / white colour, closed pattern with flat bottom and cover and mild steel chromium plated aluminium hinging device for pedestral pattern WC complete all as specified and directed. 75 S&F Glass shelf assembly cosisting of 5.5mm thick sheet glass shelf 12cm wide with CP bracket guard and railing 60cm long complete all as specified and directed. 76 S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete all as specified and directed. 77 S&F PVC (SWR) pipes 110mm bore single socketed in any length with rubber ring joints fixed to wall complete all as specified and directed. 78 S&F PVC (SWR) pipes 75mm bore single socketed in any length with rubber ring joints laid in floors, trenches complete all as specified and directed. 79 S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. 80 S&F Stack clamps made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 110 mm PVC pipe complete all as specified and directed. 81 S&F Stack clamps made out of 50x5 mm flat iron, 16mm dia round iron stays including bolts & nuts and securing ends of stays to wall or roof for 75 mm PVC pipe complete all as specified and directed. 82 S&F PVC(SWR) bends, any radius of 110 mm bore without access door complete all as specified and directed. 83 S&F PVC(SWR) bends, any radius of 110 mm bore with access door complete all as specified and directed. 84 M/L PVC(SWR) Tee of110mm dia etc complete all as specified and directed. 85 S&F PVC(SWR) bends, any radius of 75 mm bore without access door complete all as specified and directed. 86 S&F PVC(SWR) bends, any radius of 75 mm bore with access door complete all as specified and directed. 87 S&F PVC (SWR) branch pieces, single (equal or un equal) , ordinary or inverted (spigot or socket type) or with parralled branches of 110 mm dia with access door complete all as specified and directed. 88 S&F PVC (SWR) branch pieces, single (equal or un equal) , ordinary or inverted (spigot or socket type) or with parralled branches of 75 mm dia with access door complete all as specified and directed. 89 S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed. 90 S&F PVC (SWR)floor trap of diameter of outlet 75 mm, plain with gratingincluding jointing with solvent cement 75mm dia etc complete all as specified and directed. 91 S&F PVC (SWR) P trap for 110 mm dia etc complete all as specified and directed. 92 S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 1000 litre capacity hoistedand fixed in position complete all as specified and directed. 93 S&F Ball valves 20mm dia high pressure of PTMT with epoxy coated Aluminiumrod& high density plastic ball screwed for iron pipe and fixed.(Minimum weight210gms) complete all as specified and directed. 94 M & L for preparation of new steel surfaces any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red-oxide primer complete all as specified and directed. 95 M&L Water proofing treatment on Non approachable / non accessible and approachable roof surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment,properly cleaning & drying the concrete surfaces complete (i) Applying a coat of oxidised bitumen based solvent primer @ 0.3 Kg / Sqm 96 Applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 kg/ Sqm incl cleaning surfaces complete all as specified and directed. 97 Laying evenly over the bitumen coated surface, polymeric water proofing membrane Hyperplas standard wt not less than 3kg /Sqm with 100 mm over laps shall be sealed by flame as per manufacturers instruction complete all as specified and directed. 98 Applying two coats ofaluminium paintincluding preparation complete all as specified and directed. 99 M&L10 mm thick rendering on roof surfaces/ concrete surface in CM 1:4 with liquid water proofing compound @ 200 ml per 50 Kg cement complete all as specified and directed. (Waterproofing compound should be measured and paid separately). 100 M&L for Laying of 150 mm Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.Note :-a) The rates include for laying pipes level or to falls in trenches, etc. on concrete bed or directly on hard ground as indicated and making joints and testing as specified.(b) The pipes shall be measured net as fixed between the fittings and specials, if any, without any allowance for cutting and waste.(c) The rates include for all necessary extra joints, waste, and cutting etc. Excavation and earthwork shall be measured separately. 101 M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed.Note :-The rates in this table are exclusive of any excavation and refilling but include for removing and replacing manhole covers and temporarily plugging drains as required and also risk in cutting. 102 M&L for cement concrete bed to drain pipes including packing under and haunching againstthe sides of pipe after they are laid & tested for 150 mm bore of pipe withcement concrete 1:3:6 type C-2 using 40mm graded stone aggregatecomplete all as specified and directed.Note :- (a) The rates for concrete beds to drain pipes cater for the following widths and thickness.(i) Thickness of bed below the barrel of pipes: 10cm for pipes 100 mm and 150mm dia.(ii) Width of bed: Outer diameter of drain pipes (not of sockets/collars) plus 30 cm.(b) The rates include for any necessary shuttering and supports to concrete and for laying beds to falls.(c) Excavation, refilling, etc., of trenches shall be measured separately. 103 M&L in repairs salt glazed stone ware gully traps size 150 x 150mm, square or round mouthed, type ‘P’ including setting and jointing to drains with CM 1:1 including demolition of existing traps complete all as specified and directed. Note :- The rates include far setting and jointing to drains with cement mortar 1:1. All excavation and earthwork, concrete in beds, surrounds, kerbs, etc. and cast iron grating, shall be measured separately. 104 M&L for pre cast cement concrete 1:1.5:3, type A-1, using 20mm graded stone aggregateas in cover slabs (for manholes etc) and similar articles with plain faces, set in CM 1:4 including demolition of RCC of any description and in any position not other wise specially provided for reinforcement cut as required to facilitate including demolition complete all as specified and directed. 105 Demolition of cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. 106 Excavation in trench in any type ofsoil not exceeding 1.5M wide and not exceeding 1.5M in depth not exceeding 10 sqm on plan and getting out in any type of soil complete and returning and filling as required and remaining excavated soil reoval todistance upt 250 mtr. comple all as specified and derected.Note : cost of road cutting also deemed to include and where as required 107 Demolition of reinfored cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. 108 Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillar etc but excluding ashlar facing dressed stonework and precast concrete surfaces complete all as specified and directed 109 M&L for cement concrete 1:3:6, type C1, using 20 mm graded stone aggregate as in cement channels and drain , fdn sub base etc complete all as specified and directed by Engineer-in-Charge. 110 Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stoped ends etc complete all as specified and directed 111 M&L for rendering 10mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified. 112 Formwork rough finished surface of concrete as in faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter .complete all as specified and directed. 113 M & L PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in cills, steps, seismic and other similar bands, plinth courses, string courses, parapets and railing upto 60 cm in height, coping, kneelers, apex stones bed plates, column / post fdn concreteetc and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary use and waste of form work, complete all as specified and directed. 114 Demolition of plain cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) 115 M & L Moorum/Red bajri spread, rolled with 8 to 10 roller and consolidated to gradient and camber/slope required. Complete all as specified. 116 M & L machine pressed precast concrete 60mm thick glossy interlocking paver block M-35 Grade to IS 15658-2006, with grey cement and no pigment laid over dry sandcushioning, filling of joints with sand. colour and shape asapproved, complete all as specified and directed. (Note : Sandcushioning shall be measured and paid separately) . 117 S & F Reinforced concrete pipes 600 mm bore, class NP2 , laid and jointed complete with collars, including demolition and breaking up drain pipes, complete all as specified and directed. 118 S & F Reinforced concrete pipes 450 mm bore, class NP2 , laid and jointed complete with collars, including demolition and breaking up drain pipes, complete all as specified and directed. 119 M & L sand filling under floors or interlocking tile or in foundation including watering and consolidation complete all as specified and directed 120 M & L 50mm thickPCC 1:2:4type B-1 using 20 mm graded aggregate as in floor/paving etc and incl contraction joint as required., complete all as specified and directed. 121 Earth work in excavation of all kind of soil by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m complete all as specified and directed. 122 M & L for PCC 1:3:6 type C2 using 40mm graded aggregate as in plinth protection and similar work, finished concrete surfaces even and smooth without using extra cement, complete all as specified and directed. 123 M & L for preparation of newly plaster surfaces of wall and applying three coat of white wash complete all as specified and directed. 124 S & F tubular rolled sections as post, rafter, purlin, and its connected wk for shed structure and similar work complete using ERW or induction butt welded tubes conforming to I.S. 1161-1976 grade St.-240, all as specified and directed. 125 S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in sun shade, roof covering/ cladding to wall, and similar work fixed with self tapping screws complete all as specified and directed. 126 S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in sun shade, roof covering/ cladding to wall, and similar work fixed with self tapping screws complete all as specified and directed. 127 M & LProviding and laying at or near ground levelfactory made kerb stone of M-25 grade cementconcrete in position to the required line, leveland curvature, jointed with cement mortar1:3 (1 cement: 3 coarse sand), includingmaking joints with or without grooves(thickness of joints except at sharp curveshall not to more than 5 mm), including making drainage opening wherever required complete. complete all as specified and directed. 128 M & L 20 - 25 mm thick machine cut Kota stone slab in flooring or treads of steps over and including 20mm thick screed bed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing, including dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and directed.Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size, except the location where the balance portion remain less than size as specified above. 129 M & L glazed ceramic coloured tiles, 300mm x 200mm /300mm x 450mm / 350mm x 450 and 7 mm thick on vertical surfaces such as dados, skirting and risers to steps etc. set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10mm thick backing coat to receiving to wall tiles in Cement mortar 1:4, including dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) andrubbish off the premises complete all as specified and directed. 130 M&L point wiring with 1.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceilingwith and including 1.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, conceiled on walls and fixed by neans of brass screws incl modular cover plates and cover frme any size/module,for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for the following complete for One light / fancontrolled by one, one way switch 5/6 Amps all as specified and as directed . 131 Description all as per ser item No. 159.00 above, but for one 3 pin, 5/6 amps socket outlet point on independent boardcontrolled by one, one way 5/6 amps switch 132 Description all as per ser item No. 159.00 above, but for one 3 pin, 5/6 amps socket outlet point on same boardcontrolled by one, one way 5/6 amps switch 133 M&L point wiring with 2.5 sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLSH copper cable, 1100 volts grade, with multi stranded copper conductor drawn through and including non-metallic, rigid non mettalic PVC conduit (medium grade) concealed in wall / ceilingwith and including 2.5 sqmm single core PVC insulated, multistranded, unsheathed, FRLSH copper conductor cable as continuous earth continuity conductor (green in colour) with cast Iron / pressed steel modular terminal boxes any size/module, conceiled on walls and fixed by neans of brass screws incl modular cover plates and cover frme any size/module,for mounting or housing switches, socket outlets, fan regulators, etc. including all other fixing accessories for one 15A socket point independentcompleteincl taking down of old unsv point wiringall as specified and directed. 134 S&F in replacement of Ceiling rosethree terminals surface bakelite type, AC, 50 HZ, 230V complete all as specified and directed. 135 S&F modular switch1 way 6 A , 1 modulecomplete all as specified and directed. 136 S&Fmodular socket 6 Amps 2/3 pin combined2 module complete all as specified and directed. 137 S&Fswitch modular type 16 A, 1 module complete all as specified and directed. 138 S&F socketmodular type multipurposes 6/16 A, 2 module complete all as specified and directed. 139 S&F surface /wall mounted LED batten fiitng slim channel type poly carbonate bodyT-8 tube light luminare with system efficiency 120 lumens per watts. High quality polycarbonate end cap in white finish and snap fitted to the housing completeall as specified and directed.integrated electronic driver complete with all connectedaccessories all as specified and directed. 140 S&F MCB DB SPN 8 way ,IP-43, IK 09, double door type with metal doorwith 200 Amps rated bus bar ,230 volts, 50 Hz complete all as specifed and directed. 141 Supply & FixMCB SPN 32 Amps current rating C series 10 KA breaking capacitycomplete all as specified and directed. 142 Supply & FixMCB SP 6 to 32 Amps current rating C series 10 KA breaking capacitycomplete all as specified and directed. 143 Supply and laying and testing Cable XPLE insulated, screened , PVC bedded galvanised steel strip or wire armoured electric power cable (Heavy duty) 1100 volts grade with stranded aluminium conductor of6 sqmm4 core all as specified and as directed. 144 S & FLED bldg security light fitting30wattmade up of pressure die cast aluminium housing with acylic cover as diffuser with IP-66 protection complete incl mounting pipe made of GI tubing 40 mm size 1M length bend into size with mounting brackets nut bolt and washers all as specified and directed. 145 S&F in repairs angle holder modular type with cord grip cap, ISI marked complete all as specified and directed. 146 M&L fine sand cushioningfor cable protection in layers incl punning all as specified and directed.Note : Punned down thickness shall only be measured. 147 Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm all as specified and as directed. 148 S & F tubes, light grade,galvanised, with all fitting of size 40 mm laid in trenches for cable protection all as specified and directed. 149 Removing excavated soil to a distance not exc 50 m and depositing where directed at a level not exc1.5m above the starting point all as specified and as directed. 150 M & L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.50 mtr deep below normal ground level, connecting to GI earth wire 4mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron or steel including 15 mm dia. medium grade protection pipe for earth lead complete with charcoal and common salt including watering arrangement with galvanized iron pipe light grade 20 mm dia, PCC Chamber, CI frame and cover, MS funnel with wire mesh all as shown in electrical plate no 3 of SSR part I including excavation and earthwork in any type ofsoil/strata and testing on completion. Note:- GI earth wire 4 mm dia and 15 mm dia protection pipe upto 7.5 mtr from earth plate is deemed to be included in rate quoted. 151 S & F tubes medium grade galvanised with all fitting laid in trenches of 20 mm bore 152 S & F 20mm dia gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed all as specified and directed by Engr-in-Charge 153 S & F exhaustfannon metalic single phase 230 volt of size200 mmsweep with louverincl necessary altration in Aluminium or Iron window all as specified and as directed 154 S & Fexhaustfannon metalic single phase 230 volt of size300 mmsweep with louverincl necessary altration in Aluminium or Iron window all as specified and as directed