}

Tender For Special Repair To Building No T-11, T-13 T-14 B, T-28 And Provision Of 99 Nos Of Geysers At Babina Cantt Under Ge Babina., babina-Uttar Pradesh

Tender Notice

52135508
Tender For Special Repair To Building No T-11, T-13 T-14 B, T-28 And Provision Of 99 Nos Of Geysers At Babina Cantt Under Ge Babina.
Tender
Indian
Uttar Pradesh
Babina
03-12-2025

Tender Details

Tender For Special Repair To Building No T-11, T-13 T-14 B, T-28 And Provision Of 99 Nos Of Geysers At Babina Cantt Under Ge Babina.; 1 Taking down chowkhat or frame (without taking off shutter from the frame)not exceeding 1.5 Square Metre each ,complete all as specified and as directed. 2 Taking down chowkhat or frame (without taking off shutter from the frame) exceeding 1.5 sqm and not exc 4.00 sqm each , complete all as specified and as directed. 3 M&L for PCC 1:3:6type C0 (12.5mm stone agrregate)for filling in pressed steel frames and likecomplete all as specified and directed 4 S&F30 mm thick Flush shutters ,soild coreconstruction ,with paticle board core and plywood face panels , commercial type both face is covered with decorative face veneer with lipping /frame to match and complete all as specified and directed. 5 M & L for 35 mm thick glazed and skeleton shutters of 2nd class Hard Wood, open rebated and prepare to reveive glass, guage etc (without sash bars ) edges of framing plain chamfered or rounded, fitted with moulded beads both sides for securing glass etc, size of members of shutters as specified complete all as specified and directed. 6 M&L preperation of new wooden surface and applying two coat of synthetic enamel paint over a coat of pink primer onnew wooden surface any description not otherwise described over 10 cm width or girth and complete all as specified and directed. 7 M & L forPowder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors , windows , ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. 8 M & L forPowder coated (minimum thickness of powder coating 50 micron) aluminiumwindow and ventilator (adequate track)/Shutter without sash, aluminium section weighing 0.55 kg/m including joining cleats, glazing clips, rubber neoprene packing, necessary powder coated hardware ie. handles, barrel tower bolts, hinges etc, powder coatedaluminum snap beading, screws etc. complete all as specified and directed Note : Panel filling ie. glass, fibre sheet, board, wire mesh etc. shall be measured and paid for separately. 9 S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-Charge. 10 M & L forPowder coated (minimum thickness of powder coating 50 micron) aluminium door shutters of aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing, powder coated aluminium handles 150mm size 2 Nos,3 Nos powder coated aluminium hinges heavy duty and 02 Nos 150mm long powder coated aluminium tower bolts in each door shutter withpowder coatedaluminum snap beading, screws etc. complete all as specified and directed Note : Panel filling ie. glass, fibre sheet, board etc. shall be measure and paid for separately. 11 S&F infor floor door stopper of brass body and tongue, overall length of cover plate 150 mm , anodized, with hard drawn steel spring , fixed to shutters complete all as specified and as directed. 12 S&F for butt hinges , extruded aluminium alloy with galvanised mild steel hinge pin anodised of100 mm sizeand fixed type C-21complete all as specified 13 S&F for Extruded aluminium alloy handle of 150 mm size fabricatedtype, anodised complete all as specified.. 14 S&F for aluminium anodised barrel tower bolt of 150mmof extruded section complete all as specified. 15 S&F Aluminium alloy, anodised, sliding door bolt 250mm long with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed 16 S&FMS 150 mm ordinary rat tail springs plate type incl.rollar plate etc. 17 S&F 4.0 mm thick ordinaryglassof selected qualityin square not exceeding 0.5 sqm in each pane, fixed to aluminumframe with and including suitablerubber beadingcomplete all as specified and directed 18 S&F 4.0 mm thick ordinary glassof selected qualityin squareexceeding 0.5 sqm in each pane, fixed to aluminumframe with and including suitablerubber beadingcomplete all as specified and directed 19 S &F for door closer hydraulically regulated, designation No. 3, universal type, aluminium die-cast body (ISI Marked),suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed in repair complete all as specified and directed 20 S&F galvanised wire cloth, 0.48mm nominal dia of wire and average width of aperture 1.18mmand fixed with tinned tacks or galvanisedstaples complete all as specified and directed 21 S&F for framed work such as grills gratings, etc, with ends of bars shouldered and or riveted , or forged into spikes, framed guard bars , barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe 290,E-165 , complete all as specified and directed. 22 Demolition of cement concreteof any description and in any position (unreinforced) in ground floors and paving not exceeding 15 cm thick (below or above GL) complete all as specified and directed. 23 Demolition of cement concrete of any description and in any position reinforced concrete (re-inforcement cut to facilitate demolition) including disposal of unserviceable of mateial complete all as specified and directed. Note:Demolition material throughout MOD Land rate include above item 24 Excavation over area as in soft / loose soil nexc 1.5 m deep and getting out complete all as specified and as directed. 25 Dismantiling of stone slabs and tiles (Kota stone etc.)of any discription or any thickness in floors, aprons, skirting, dado, pcc tiles at roof etc.laid bedded and pointed in any mortar complete all as specified and directed. 26 Dismantling floor, hearth or wall tilingof any description and in any positionincluding cement mortarbedding (but not backing) complete all as specified and directed. 27 M&L moorum /red bajri filling in floors or paving laid in layers n exc 15cm thick spread leveled and rammed including watering complete all as specified and directed by Engineer in charge. 28 M&L 75mm thick PCC (1:3:6) Type C2using 40mm graded stone agg as in plinth protection etc surface even and smooth without using extra cement complete all as specified and as diected by engineer in charge. 29 M&L25 mm thick cement concrete (1:2:4) type B-0 (12.5 mm graded stone aggregate) as infloors,finish rough to receive the floor finishes etc 30 M&L for vitrified ,coloured and printedtiles of8 to 10 mm thick (Square / Rectangular ) polished area of each tilesexceeding 0.42 Sqm but not exceeding 1.00 sqm as in flooring over and including 15 mm thick cement screed in (1:6 ) CM set and jointed in neat cement slurryand pointed in white or coloured cement to match with the colour of tiles complete all as specified and directed. 31 M&L for vitrified ,coloured and printedtiles of8 to 10 mm thick as in skirtingfixed over and including 10 mm thick backing coat in (1:4 ) CM set and jointed in neat cement slurryand pointed in white or coloured cement to match with the colour of tiles complete all as specified and directed. 32 M&L for digital glazed ceramic tiles, coloured tiles 300mm x 600 mm x 7mm thickon vertical faces ie. as in skirting/dado etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles fix over and including 10 mm thick backing coat in cement mortar (1:3)completeall as specified and directed. 33 M&L Granite slab18 mm to 20 mm thick machine cut, bedded and joined withcementand pointed with white cement with admixture of pigment to match over and including 20 mm thick screed bedCM (1:3) .the shade of granite stone including cutting and polishing type as incill and jamb/skirting, steps cooking plateformsincludigng rounding off the exposed edges and polishing all asspecified and directed.. 34 M&L for machine cut Kota stone slab 18 mm to 22 mm thick , as in flooring,laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and including screed bed or bedding layer of mortar 15 mm thick in cement mortar (1:6 ) complete all as specified and directed. 35 M&L for machine cut kota stone slab 18 mm -22 mm thick as in riser / steps, skirting, dado,cills and pillars laid and jointed with grey cement slurry mixed with pigment to match with the shade of the slab including rubbing and polishing over and including 10 mm thick backing coatin CM (1:4) complete all as specified and directed. 36 Taking downcement or cement lime plaster on brick or stone walls etc. including racking out joints hacking for key scrubbing down with water etc.complete. 37 M&L for 15 mm thick rendering in cement mortar (1:4) on brick / concrete/ stone surfaces finished even and smooth without using extra cementcomplete all as specified and as directed. Note : Water proofing compound shall be measured and paid separately under appropriate item of BOQassupply only 38 M&L for 15 mm thick rendering in cement mortar (1:6) on brick or concrete surfaces finished even and smooth without using extra cementcomplete all as specified and as directed. 39 Supply only Liquid water proofing compound complete. 40 M&L fornew plaster surfacesof walls applying two coats of exterior emulsion acyrlic weatherproof antifungal paint over a coat of exterior grade primer (including putty ) upto 08 meter height of the bldg, complete all as specified and directed. (Make -Asian Apex, Berger) 41 M & L for two coat of oil bound emulsion paint over a coat of Birla wall care putty on plastered surfaces on wall incl. preparation of surfaces complete all as specified and directed. . 42 M&L Complete removal of existing treatment(internal and external suraces) on wallsby scrapping with steel wire brush or any other means including onecoat of wall care putty on wall andapplying two coat ofoil emulsion complete all as specified and directed by Engineer -in-Charge. 43 Demolition of brick work /stone work built in cement mortar including all quoins, arches, pillars etc complete all as specified and as directed. 44 Removing excavated material nexc 50m and depositing where directed at a level nexc 1.5Km above the starting point with soil complete. 45 M&L Brick work with sub class B bricks straight or curved on plan exc. 6m mean radius built in cement mortar (1:6). 46 S & F Peg set of six S.S.fixed to wall with PVC plugs and screw complete. 47 S & F in repairCurtain rail stainless steel decorative type 25 mm diaincluding fixing bracket and end knobs complete specified and diected by engineer in charge. 48 Surface excavation n.exc. 30 cm deep and av. 15 cm deep and getting out in any type of soil complete 49 M&L for PCC Type D2 (1:4:8) using 40mm graded stone agg as in foundation filling mass concrete, complete all as specified and directed. 50 Material and labour for providing and laying60 mm thick factory made Locally available chamfered edge cement concrete paver block of M-35 grade with aproved colour, design & attern as in foothpath, parks, lawns, drive ways or light traffic arking etc. of required strenght, thickness & size / shape, made by table vibrating method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding / laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra cement complete all as specified and directed. 51 M&L for cement concrete ( 1:2:4) type B-1 (20mm graded agrregate) in lintels upto 1.5m clear span, cills, stes, seimic and other similar bands, plinth course, string course, lacing cours, arapets and railingsupto 60cm in height, coping, kneelers, apex stones, bed plates, kerbs, water througs and the like including wheathering slightly rounded or chamfered angle and throating complete all as specified and directed. 52 M&L for preparation surfaces for building Nosand applying one coat of synthetic enamel paint and writing letters or figures (Block, Roman, Italic or Indian) of n exc 10cm height, width of letter shall not be less than 15mm, including stops, commas, lines, brackets and making outer boarder with approved tint of synthetic enamel thick paint complete all as specified and as directed. 53 Dismantling of wall and ceiling boards fibre pulp insulation etc or insulation boards/slabs/blankets any thickness including cover fillets, complete all as specified and directed. 54 S&FFalse ceiling4 mm thick HPSC pre-prime non asbestos fibre cement building board ( size 600mm x 600 mm/ 595 mm x595 mm ) decorative finish fixed with clips and screw includingpowder coated galvanised MS grid frame work false ceiling of ( Main Tee size 32mmx20mmx0.45mm cross tee 24mmx24mmx0.30mm andwall angle19x19x0.30 mm) and with slot for fixing including suspended with1.25 mm dia. GIwirehangers fixed with steel dash through fasteners from purlineof the roof complete all as specified and as directed. 55 Dismantling of AC (corrugated / semi-corrugated) sheets in roof covering including any type of ridges complete all as specified and as directed. 56 S&F Pre painted galvalum sheet 0.50 mm thick havingaluminum zinc coating 150 gsm/ sqm corrugated steel sheetany colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws complete all asdirected by Engineer -in -charge. 57 S&F Pre painted galvalum sheet 0.50 mm thick havingaluminum zinc coating 150 gsm/ sqmplain steel sheetany colour having tensile strength of 550 Mpa as in Roof covering /cladding (ridge) to wall fixed with self tapping screws complete all asdirected . 58 M&L Hand rails, half round or other stock section or core for wooden hand rail straight portion , drilled and counter sunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing postincluding cutting tops to shape as directed, drilling holes, notching for wire , etc.; flat iron fillets ( for securing wire mesh etc. including all necessary drilling , bolting or rivetting , etc., and similar work conforming to Fe 290 Gde E 165 with and including applying two coats of synthetic enamel paint over a coat of primer alround before fixing in position complete all as specified and directed 59 Dismantling timber scantling, framed /un framed workof 40 sq. cm and over in section in any position complete as directed. 60 Dismantling of wrought iron or mild steel work of any description not other wise provided for complete all as specified and as directed. 61 S&F rolled section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors fixed with angle cleats or other connecting plates confirming to Fe-290 ( Gde E-165) complete all as specified and directedMAKE : SAIL ,RINL TATA , KAMDHENU OR EQUIVALENT 62 M&L for two coats of synthetic enamel paint over a coat of red oxideprimer on new steel surfaces over 10 cm width or girth including preparation of new surfaces. 63 Cutting of cracks to V section in existing wall surface, cleaning out, wetting, grouting with cement and sand slurry 1:3 etc complete all as specified and directed. 64 M&L forreinforced cement concrete nominal mixtype B1 (1:2:4)( using 20 mm graded stone aggregate ) as in beams , cantilevers bressummers , lintel over 1.5 m span etc. complete all as specified and directed. 65 M&L for use and waste Formwork to sides & soffits of floor or roof beam rough finishedsurfaces of concretecomplete all as specified and directed. 66 S&F mild steel bars 10 mm dia and over (TMT) cut to length bent to shape required including cracking,bending spirally for hooping ends and binding with and including mild steel wire not less than 0.90 mm dia quality of steel conforming to Fe-410-0 or Fe-410-S. 67 S&FTMT bars 6 to 8 mm diacut to length bent to shape required including cracking,bending spirally for hooping ends and binding with and including mild steel wire not less than 0.90 mm dia quality of steel conforming to Fe-410-0 or Fe-410-S. 68 Dismantling boarding any description fixed with nails in any position (including cup board shutter/shelve upto 25mm thick) complete. 69 S&F in repair 18/19mm thick WPC board, prelaminated both face with decorative choice laminations one side and other side balancing white, fixed with screws to timber frame work includingbeading on cutting /exposed edges, polishing for cupboard shutter including hardware. 70 S&F for aluminium anodised barrel tower bolts of extruded section of 100mm size, complete all as specified and directed. 71 S&F for continuous (piano) hinges mild steel bright finish or electro galvanised width of width of flaps nexc 30 mm (when open), complete all as specified and directed. 72 S&F for extruded aluminium alloy handle of 100 mm size fabricatedtype, anodised.complete all as specified . 73 S&F for Haps and staple safety type Aluminium anodised with MS hinge pin including bolt to hinge pin of 100 mm size sixed with screw complete all as specified . 74 S&F for magnate catcher of metal body and striking plate heavy duty includind fixed with screw, complete all as specified and directed. 75 M&L marble stone strip as in border etc in kota stone flooring machine cut bedded jointed and pointed with grey cement slurry including cutting and polishing to mirror finish complete all as specified and directed.Note :- Marble strips of 75 mm wide & 10 to 15 mm thick shall be used. 76 S&F 4 mm thick, 600mm wide rounded edge mirror of selected quality glass, with back polishig mounted and fixed with stainless steel decorativecap wahsers and screws set fixed on PVC rawl plugs complete all as specified and directed. 77 S&F for in repairsofvitreous china wash basin, white, oval type, size 550 x 400mm Including waste coupling ,waste pipe and labour for fixing pillar tap ,pvc connection but including cutting for and pinning in ends of and including brackets complete all as specified and directed. . Note : Pillar tap andPVC connection will be measured paid separetly. 78 Taking up or down steel tubing and connetion including cleaning for refixing or removing to store of 20mm bore of pipe, complete all as specified and directed. 79 Taking up or down steel tubing and connection including cleaning for refixing or removing to store of 25mm bore of pipe, complete all as specified and directed. 80 supply and laying 20 mm dia .of bore CPVC pipe SDR11 and Plain CPVC SDR11 fittings (ISI ) marked ,concealed or fixed to wall or laid in floors complete all as specified and as directed 81 supply and laying 25 mm dia .of bore CPVC pipe SDR11 and Plain CPVC SDR11 fittings (ISI ) marked ,concealed or fixed to wallor laid in floors complete all as specified and as directed 82 S&F for in repairs 15mm angle cock ISI Mark chromium plated,cast copper alloy, with brass ceramic disc spindleand capston heads,scewed down high pressure, with or without lettered hot or Cold with long srewed shanks and flynuts, srewedfor iron pipe fixed and complete all as specified ..MAKE : Neptuneseries of Prayag or similar in PARRYWARE/CERA /JAQUAR/HINDWARE 83 S&F for 15mm ,bib tapISI Mark Fancy type long body chromium plated,cast copper alloy, with brass ceramic disc spindle and capston heads,scewed down high pressure, with or without lettered hot or Cold with long srewed shanks and flynuts, srewedfor iron pipe fixed in repair and complete all as specified .MAKE : Neptuneseries of Prayag or similar in PARRYWARE/CERA /JAQUAR/HINDWARE 84 S&F for in repairs Soap dish of CP fixed with pvc rawal plugs and screw, complete all as specified and directed. 85 S&F for in repair Aluminium Anodised tubular towel rail D type 20mm dia and 60cm long complete all as specified and directed. 86 Supply only15mm dia PVC connection with PTMT nuts of length 450 mm, complete all as specified and directed. 87 S & F in repair Rotational moulded poly-ethylenewater storage tanks (cylinderical vertical with closed top) 1000 litres capacity, triplr layer in construction white in colour hoisted and fixed in positioncomplete all as specified and directed. 88 S&F for 20mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20 m m - 210 gms / 25mm-455gms/ 40mm - 690 gms) complete all as specified and directed. 89 S & F in repair for plate rack made out of .90 mm thick stainless steelof wire type / sheet patternsize nad type as directed by Engineer In Charge and approved by GE fixed to wall with necessary fitting arrangement Complete all as specified and directed. 90 S&F for 75 mm dia PVC(SWR)pipes single socketed, in any length with rubber ring joints,laid in trenches or in floors complete all as specified . 91 S&F 5mm thick hollow wall panelling plain colour PVC sheet in strips & channel feathered at the edges for fixing on Solid PVC Wall Lining,Insulated PVC Wall Lining, and Solid PVC Partitions inclusive of solvent cement and fixing at site including disconnecting and refixing of electric light board complete all as specified and as directed. 92 M & L PCC 1:2: 4 type B-1 using 20 mm graded store aggregate as in surface channel, drains etc including use and waste of form work where necessary complete all as specified and as directed. 93 Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using forms, moulds, mitred/stopped ends etc. 94 Demolition and breaking drain pipe (salt glazed stoneware) of 150mm dia set in cement mortar including packing under and haunching against side of pipe complete all as specified and as directed. 95 Supplying, laying, jointing and testing salt glazed stone ware drain pipe 150mm dia grade ‘A’ laid in trenches and jointed in cement mortar 1:1 complete all as specified and as directed. 96 M & L cement concrete bed to drain pipe 150mm dia including packing under and haunching against side of pipe after they are laid and tested in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate complete all as specified and as directed. 97 Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth for sewage line, manhole etc not exceeding 10 sqm on plan and getting out in Soft/Loose type of soil complete all as specified and as directed. 98 Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed. 99 Taking down carefully existing aluminum / copper point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, ceiling fan with regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc to match with existing surfaces complete all as specified and directed. 100 Taking down submain wiring of any size any type and in any position metalic/non metallic PVC conduit of wooden batten complete all as specified and directed. 101 Taking down unserviceable Sheet metal box & MCB DB TPN with MCBs of any make/capacity, complete, all as specified and directed by Engr-In-Charge. 102 Taking down carefullyexisting wooden board , Main switch, MCB DB boxes with MCBs, sheet metal boxes, cut out, etc of any size anycapacity fromboards completeall as specified and as directed. 103 Taking down carefully sub main wiring / service connection twin core from wall / LT pole of any size of Aluminum with wooden batten and or through rigid conduit including GI wire and making good the disturbed surfaces of walls, roofs, floors etc complete all as specified and as directed. 104 M & L for Modular concealed point wiring including cutting chasing filling of surface for fixing of conduit and making good distrubed surface one lightcontrolled by one modular switch with PVC insulated and unsheathed flame retardant Low Smoke(FRLS-H) cable of 1.5 sqmm including taking down of old U/S point wiring (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, withmodular MS terminal boxes (not less than 1.6mm thick) including earth dolly and 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed for the following. Note : Modular matching cover frame pates of defferent sizes areshall be measured separately. 105 One light point controlled by one switch. 106 One Ceiling fan point controlled by one switch. 107 One Exhaust fan point controlled by one switch. 108 One 5 pin multipurpose socket out let 5/6 Amps on the same board with other switch. 109 One 3 pin/5 pin switch socket outlet, 5 Amps on independent board. 110 Description all as per item No 104.00 here in before but point wiring with 2.5 sqmm FRLSHconfirming to IS 694:2010, multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sqmm FRLSH PVC insulated multi strand copper conductor cable as continous earth wire. 111 Description all as per item No 104.00 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke and halogen ( FRLSH ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 2.5 sqmm green multi stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed. 112 S&F switch pianoflush button type 5 Amp single pole one waycomplete all as specified and asdirected. 113 S&F socket outlet 2in1, 3 pin, 5 Amp flush type complete all as specified and asdirected. 114 S&F switch piano flush button type 15 Amp single pole one way complete all as specified and asdirected. 115 S&F socket outlet2in1, 3 pin, 5 Amp and 15 Amp flush type complete all as specified and asdirected. 116 S & F delux Fan Regulator electronic rotary, step type 240 Volt50 Hz,complete all as specified as directed. 117 S&F Modular switch 1 way 6A,1 module complete all as specified and directed. 118 S&F Socket, 6A - 2/3 pin combined 2 module,complete all as specified and directed. 119 S&F Modular switch 1 way 16A,1 module 15 Amp complete all as specified and directed. 120 S&F Socket 6A/16A - 6 pin combined 2 module complete all as specified and directed. 121 S&F ceiling rose surface bakelite 63.5 mm dia three terminal complete all as specified and directed. 122 S&F Fan step regulator, 120W - 2 module 240 volts, AC 50Hz complete all as specified and directed. 123 S&FLamp holder with metal ring, PVC/Polycarbonate type with back plate suitable for batten fittings ISI Marked complete. 124 S & F 9W/10W LED retrofit lamp B-22 holder base with polycorbonate body and aluminium heat sink complete all as specified as directed. 125 S & F sheet metal box Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp complete all as specified and as directed. 126 Supply and fixing in repair 20 W LED 6000k Decorative ultra slim linear LED fitting fixture with extruded polycarbonate ,environmental friendly ,energy efficentinterated driver and 28watts lamp fitted including wiring upto and terminal into ceiling rose complete all as specified and directed by Engr-in- Charge. 127 Supply and fix LED 35/36W street light fitting,5700 K energy saving & environmental friendly long life versatile pressure die cast aluminiumIP 66.road way luminare with high power LEDs as light source and electronic driver suitable for pole dia 35 mm including 35 mm dia light grade tube bracket ,bend to shape 1.80 mtrlength with two nos of clamps of size 50mm x 6mm with nuts and bolts,washers etcincluding connection with 1.5sqmm threesinglecorePVC insulated and PVC sheathed cable stranded copper cable upto ceiling rose and fixing on walls/pole complete all as specified and directed. 128 M&L, sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.(NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. 129 S & F Regid non-metallicPVCconduitnot less than 25 dia (external) ISI markedon surface and including cutting necessary chases on wall/ ceiling surface for drawing of conduit incl of all acces and all fitting such as Tees ,bendblbow reducer bell mouth , tube endand fixing accessories such as couplerlocknutsaddle pipe, hook etc complete all as specified and as directed 130 S&F TPN DB-DPX 125 MCCB DBs 4 way double door with provision for DPX 125 MCCB andas incomer CONCEALED ON WALLand SP/TP MCBs as out going no of modules DPX 100, Complete all as specified and as directed. 131 S&F TPN DB-DPX 125 MCCB DBs 4 way double door with provision for DPX 125 MCCB CONCEALED ON WALL andas incomer and SP/TP MCBs as out going no of modules DPX 125+12, Complete all as specified and as directed. 132 Supply and fix MCCB having breaking capacity of of 16 KA 415V, 4 pole having rating capacity of 100 Amp 100% ICU complete all as specified and as directed. 133 Supply and fix MCCB having breaking capacity of of 16 KA 415V, 4 pole having rating capacity of 125 Amp 100% ICU complete all as specified and as directed. 134 S&F MCB DB, sheet metal enclosures double door SPN 8 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed.. 135 S&F sheet metal enclosure double doorconcealed suitable for distribution boards when MCBs to be used having 100 Amp rated bus bar SPN DB 8 ways 240 V complete all as specified and as directed . 136 S&F, MCB SPN 40-63 Amps, 240 volts C series 10 KA ,including connection with suitable size copper lugs complete all as specified and directed.. 137 S&F, MCB SP 240 volts, 6to 40 Amps, C series 10 KA including connection with suitable size copper lugs.complete all as specified and directed. 138 S&F MCB single pole 6 to 32Amps 240 V,10KA, C series,complete all as specified and as directed 139 S&F for modular plateincluding fixing , modular switchs , modular socket ,modulare regulator complete all as specified and directed by engr-in-charge. 140 (a)White cover plate with frame but 2/3/4 module 141 (b) White cover plate with frame but 6/8/12 module. 142 Supply and laying XLPE insulated, armoured heavy duty electric cables with aluminium conductor, 1100 volts grade, cross sectional area 16 X 4 sq. mm complete all as specified and as directed. 143 Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 35 Sqmm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. 144 Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 25 Sqmm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. 145 S & F sheet metal enclosure with two pin socket , chain plug cover with one MCB DP of 20/32 Amp capacity with alignment 10 KA c’ seriescomplete all as specified and as directed. 146 S&F BLDC Ceiling fan complete with three aluminium blades down rod, snackel clamp, reel insulator, fan canopy split pin and accessories 230 V, 1200mm sweep with service value not less than 7.8, power consumption not more than 28-30 watt and minimum air delivery of 210-230 CMM, BEE 5 star rated, two core PVC insulated copper wire white sheathed of size 0.5 sqmm from fan connector to ceiling rose complete all as specified and directed.NOTE:-(I) Writing MES no in 20mm letter size with black paint etc is deemed to be included in quoted rate.(ii) Old fan deposit in store yard. 147 S&F inin replacement of 35 W of size 2 Feet X 2 Feet LED6500K rescessedmounting luminaire glare free suitable for armstrong/ grid ceiling in MS/CRCA housing with high brightness LEDs incl wiring upto and terminating into existing ceiling rose complete all as specified . 148 Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etcfor protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge. 149 Supply and Fixing Exhaust fans AC single phase 230/240V of size 300 mm sweep, 1400 RPM with louvre complete including with all arrangement of making holes on wall, making good and finishing of disturbed surfaces matching with the existing surfaces, necessary fixing arrangement such as fastener bolts, nuts, washers etc, of appropriate size all as specified and as directed 150 M&L pipe galvanised iron of size 50 mm dia, light grade ISI marked, complete with fittings laid in trenches/ fixed with poles etc as protection to cables complete as ditrected by Engineer in Charge 151 M&L for earthing completewith galvanisedsteelearth plateelectrode of size 600 mm x 600 mm x 6 mm thickweithing not less than 17.5 Kg buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade)and watering pipe 20 mm bore GI pipe(light grade) andchamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg.50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and saltcomplete and earth leadconnected to earthing test point (up to main switches, DBs) completeall as specified &testing on completion. NOTE:-(I)item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii)PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra costof additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate. 152 M & L for pvc surface conduit point wiring complete with PVC insulated and unsheathed flame retardant low smoke low smoke and halogen( FRLSH ) cable of 2.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with MS terminal boxes (not less than 1.0mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dollywith3 mm thick plastic laminated sheet top cover of approved make and colour including 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed . 153 M&L, sub main wiringwith two single core PVC insulated unsheathed FRLSH confirming to IS 694:2010, multi stranded copper conductor (ISI marked with valid CML No), cable 1100 Volt grade, 6 sqmm size drawn in and includingnon metallic rigid PVC concealed conduit medium grade (ISI marked with valid CML No) not less than 25 mm dia with all fitting & fixing accessories including one run single core PVC insulated unsheathed 6 Sqmm FRLSH confirming to IS 14930 (Part-I) 2001, copper conductor (ISI marked with valid CML No) colour code as a earth continuity and connected upto DB complete all as specified and directed.(NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chasesin wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface with putty to match with the existing surface. 154 S&F MCB DB, sheet metal enclosures double door SPN 8 way with bus bar 240 volts 2 in 1 shutter type (METAL DOOR)type with blanking plates where required and IP 43 degree protection complete all as specified and directed.. 155 S&F, MCB SPN 40-63 Amps, 240 volts C series 10 KA ,including connection with suitable size copper lugs complete all as specified and directed.. 156 S&F, MCB SP 240 volts, 6to 40 Amps, C series 10 KA including connection with suitable size copper lugs.complete all as specified and directed. 157 S&F storage type water heater (Geyser),5 star BEE rating, 230 Volt AC, 25 Ltrs capacity comprising Stainless steel inner tank,suitable heatng element, thermostate with adjustable temperature setting , indication lamps provision for inlet outlet and air vent connections & NRV,inclucluding all fixing arrangement such s faster bolts, nuts washers etc complete including making gooddisturbed wall surfaces matching with the existing surfaces and finishing all as specified and as directed. 158 S&F PVC connection 15 mm size suitable for geyser/hot water, heavy duty with brass nuts, 450 mm long complete all as specified and as directed. 159 S&F angle cock, cast copper alloy, srewed down , high pressure, with cruntch or butter fly handle, screwed both ends for iron pipe or for unions and fixed of size 15 mm dia complete all as specified and as directed. 160 S&F Bib taps, cast copper alloy with crutch or butter fly handle, screwed down, screwed for iron pipe and fixed of size 15 mm dia complete all as specified and as directed. 161 Supply and fixing galvanised mild steel water tubing of 15 mm dia bore medium grade ISI marked with and incl all fittings like bends, elbow, Tee, reducer sockets & union etc laid in trenches, under floor or fixed to walls / ceilings complete all as specified and as directed. 162 S&F MCB protected power socketunit with sheet steel enclosure include power socket ,mini MCB SP 20 A ,240V,50 Hz complete all as specified and directed 163 Material and labour for submain wiring with PVC insulated, unsheathed 2 single core cable 1100 vols grade FRLS with stranded copper conductors of size 2.5 sq mm (Nominal area) drawn into conduit (Existing / new), with and including 2.5 sq mm green PVC insulated FRLS stranded copper conductor cable as contineous earth wire terminated with copper lugs / thimbles all as specified and as directed.Note : 1.New conduit and conduit accessories shall be measured and paid separately. 164 S&F TPN DB-DPX 125 MCCB DBs 4 way double door with provision for DPX 125 MCCB andas incomer CONCEALED ON WALLand SP/TP MCBs as out going no of modules DPX 100, Complete all as specified and as directed. 165 Supply and fix MCCB having breaking capacity of of 16 KA 415V, 4 pole having rating capacity of 100 Amp 100% ICU complete all as specified and as directed. 166 Supplying, installation, connecting, testing and commissioning of outdoor type distribution transformer of 200 KVA, 11/0.433 KV, 3 phase, 50 Hz, ONAN cooled oil immersed copper wound step down enrgy efficient (Level 2) as per IS 1180 : 2014 with amended No 1, 2, 3 & 4 floor mounted complete with first fillingISI marked filtered & dehydrated transformer oil and other standard fittings / accessories and 7 position off circuit/load tap changer (tapping range +/- 7.5% in steps of 2.5% each) with vector group DYN -11 complete all as specified and as directed Note - (a) The ambient temprature shall be 48 degree Centigrade when measured by the resistance method after continuous full load run . (b) The transformer shall be complete with standard fittings all as specified and conforming to IS:335 of 1993 for oil and IS: 1180 Part -I of 2014 for transformer and comprising of followings:- (i) One No cable box on LV side (secondary side) consisting of 04 Nos of porcelain bushing with bushing rods and another cable box on HV side (primary side) consisting of 03 Nos of porcelain bushing with bushing rods etc complete with nut, washers, cable gland etc.(ii) Oil conservator tank with filter type drain valve and oil level gauge.(iii)Oil level indicator with minimum and maximum marking(iv)Dehydration silica gel breather assembly with first fill of dehydrating agent and oil seal.(v)Explosion vent with diaphragm complete.(vi)Thermometer pocket on tank cover.(vii)Dial type thermometer vapour pressure having range 0-120 degree C with max reading pointer max temp indicator and resetting device.(viii)Rating plate with terminal marking.(ix)02 Nos earthing terminal on tank and cover for fixing earth strip of size 32 x 6 mm.(x) Oil level gauge and top valve for oil filtration and drain cum sampling valve. 167 (xi)Lifting hook.(xii)Oil filler hole with cap /plug with connection complete.(xiii)Air relief valve plug.(xiv)Detachable rollers - 04 Nos(xv)Extra bushing for Neutral out side the cable box for independent earthing for neutral earth.(xvi)First fill of fresh transformer oil confirming to relevant IS and tested up to 40 KV die electric strength. (xvii)Suitable PCC foundation for mounting of tranformer. 168 Supplying, laying, jointing & commissioning in replacement of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, (Earthed) cross sectional area 95 sqmm 3 core as per IS 7098 Pt-II complete all as specified and directed. 169 Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 25 sq mm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. 170 Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 50 sq mm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. 171 Supply and laying or fixing or passing through HDPE pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel or strip and overall PVC sheathed, 185 sq mm 4 core ISI Marked as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed. 172 Supply laying dry clean sand free from sharp materials, unscreened filling in trenches around under ground cables for cushioning complete all as specified and directed. 173 M&L for PCC cable cover class HV type 1 flat size 300 mm x 180 mm x 40 mm, ISI marked across the cable for protection of cable after sand cushioning complete all as specified & directed. 174 Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etcfor protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge. 175 S&F of cable jointing Kit 11 KV (earthed) grade cable for outdoor type end termination indor & outdoor type heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 95 sqmm complete all as specified and directed. 176 Supply, installation, testing and commissioning of lightening arrester polymer typeSMX type complete with all fittings transmission class, discharge capacity 65 Kilo Amp suitable for system voltage 11 KV complete all as specified and directed. 177 M&L for switch air break gang operated triple pole polymer type, mechanically operated mounted onHT insulators (12 insulator type) and MS steel framewith operating mechanism worked from ground level with 11 KV insulation for current rating up to 200 amps 11000 volts with locking arrangement, MS clamps, nuts, bolts and washers etc also incl drop out expulsion type fuse, single pole up to 25 Amps, 11000 volts fuse barrels, incl two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and directed. 178 Supply, erecting and fixing in replacement of true vertical position, steel tubular swaged pole (410 SP-55), 11 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole shall be provided with one coat of red oxide primer and two coats of aluminium paint complete all as specified and directed.(Numbering of the poles shall be done with synthetic enameled painted letter of shape & size as directed.). The quoted rate includes cost for shifting of existing Cross arms, bracing, ACSR conductorsinsulators, GI wire from eisting pole to new poles.Note :- Excavation including earth work and PCC foundation will be measured and paid separately. 179 S & F and replacement of cross arms, bracing, supports clamps and back plates fabricated from structural steel sections incl nuts & bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed 180 Supply ,commissioningandtestingfactory madeLTfeeder pillar, outdoortypefloor mounted ,suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of3.15 mm CRCA MS sheet and 50x50x5mm thick angle iron base frame work,powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside,both side openingtype, with aprons for cable entry,with double door shutter and locking arrangementand consisting of the followingcomplete all as specified and directed. (a) Aluminiumbus barfour strips800 Amps ,415 volts,fixed on epoxy insulated with panel fixed horizontally, duly insulatedwithheat shrinkable sleeves in colour code - 01 Set.Incoming:-(b) MCCB,04 Pole, 315 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 No(Ics=Icu=100%)Outgoing:-(c ) MCCB,04 Pole, 250 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 Nos(Ics=Icu=100%)(Make :- Havells/L&T/schnider/ABB) (d) MCCB,04 Pole, 100 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts , adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I- 01 Nos(Ics=Icu=100%).(e)Spare way for MCCB 63 Amp 4 way - 01 Nos (g) Analoge type volt meter 0-500 volt- 1Set. (h) Indication lamps R,Y,BLEDtype with 3 Nos– 1 set:-(f) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminumstrips for MCCBs. Note :- Panel drawings & make of MCCB/SDFU will be submitted by contractor for approval from Accepting Officer before ordering the panel. 181 S&F in replacementtesting , commissioning of outdoor type bus barpanel padestal type weather proof CPRI aproovedMS cubical panelboard made of3 mm CRCA MS sheet outdoor type of size 100 cm x 80 cm x 40 cm, 4 Nos of aluminium bus bar of 200 Amp capacity with MCCB 4 pole of Capacity 200 Amp 25 KA (Ics =Icu=100%) including one coat of redoxide and two coat of enamel paint powder coated, mounted on mild steel channel of suitable size andPCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels,, aluminium bus barchanel insulated with colour coated heat shrinkable sleaves and mounted on DMC/Epoxy insulator all as specified & directed. LTPanel board should be as per IS/IEC 61439-I: 2011 &IS/IEC 61439-2 : 2011, Type Test certificates for Short Circuit Test, Temperature Rise Test, Di-ElectricProperty Test and Degree of Protection IP-65 at minimum 4000 Amps with Breaking capacity not less than 65KA. ( The contractor should submit all Certificates before executing the job.)

Key Value

Document Fees
INR 1000 /-
EMD
INR 197000.0 /-
Tender Value
INR 1.22 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail