| 1 | PART (A) :DESIGN & SUPPLY OF THE FOLLOWING: |
| 2 | A.1-- SPV system complete with PV modules (minimum 590 Wp TOPCon cell) installed in array with Modular Mounting Structure (MMS) complete on Ground as per site requirements.Capacity/ size-- 450KW |
| 3 | A.2--Invertor complete with safeties & protection Capacity/ size--200 KW |
| 4 | A.3--Solar meter & CT with testingCapacity/ size--As per site requirement |
| 5 | A.4-- DC cables (6 sq. mm, Copper), cable trays, supports, conduits etcCapacity/ size-- As per site requirement |
| 6 | A.5-- AC Cable - (Size as per SLD)(Copper conductor, GI armoured, XLPE/HR PVC insultaed, 1.1 KV grade cable., - Length shall be as per site requirement between Inverter to AC Isolatorbox, including cable trays in buildings & outside buildings, necessary MS supports, etc as per site requirement. Capacity/ size-- |
| 7 | A.6-- AC Cable For Solar PV System - (Size as per SLD), Aluminium conductor, GI armoured XLPE/HR PVC insultaed, 1.1 KV grade cable., - Total length (tentative cable route shown in site layout) as per site requirement between each Inverter Isolator Box to LT Power Distribution Panel and existing LT PCC , including cable trays in buildings & outside buildings, necessary MS supports, etc as per site requirement.Capacity/ size--As per site requirement |
| 8 | A.7-- Chemical Earthing system, with solid copper bonded rods (minimum 250 microns coating thickness), copper earth strips, Copper earth electrodes,lightning arrestor etc.Capacity/ size--As per site requirement |
| 9 | A.8--Remote monitoring system, Weather station (Solar irradiation sensor, wind velocity meter, Ambient temperature sensor)As per site requirement |
| 10 | A.9-- Bidirectional meter and Solar Check meter (11 KV) with CT, PT units as per Local Electricity board requirement. Necessary testing & liaison with MSEDCL/ CEIG /MEDA and obtaining approvals are included in the scope of work.Capacity/ size--As per site requirement |
| 11 | A.10-- Spares, tools, metersCapacity/ size-- |
| 12 | PART (B) : Installation, Testing and Commissioning |
| 13 | B.1-- SPV system complete with PV modules (minimum 590 Wp TOPCon cell) installed in array with MMS complete on Ground as per site requirements.Capacity/ size--450KW |
| 14 | B.2--Invertor complete with safeties & protectionCapacity/ size--200 KW |
| 15 | B.3-- Solar meter & CT with testingCapacity/ size--As per site requirement |
| 16 | B.4-- DC cables (6 sq. mm, Copper), cable trays, supports, conduits etc as per site requirement. Capacity/ size-- |
| 17 | B.5-- AC Cable - (Size as per SLD)(Copper conductor, GI armoured, XLPE/HR PVC insultaed, 1.1 KV grade cable., - Length shall be as per site requirement between Inverter to AC Isolator box, including cable trays in buildings & outside buildings, necessary MS supports, etc as per site requirement. Capacity/ size-- As per site requirement |
| 18 | B.6-- AC Cable For Solar PV System - (Size as per SLD), Aluminium conductor, GI armoured XLPE/HR PVC insultaed, 1.1 KV grade cable., - Total length (tentative cable route shown in site layout) as per site requirement between each Inverter Isolator Box to LT Power Distribution Panel and existing LT PCC , including cable trays in buildings & outside buildings, necessary MS supports, etc as per site requirement.Capacity/ size-- |
| 19 | B--7 Chemical Earthing system, with solid copper bonded rods (minimum 250 microns coating thickness), copper earth strips, Copper earth electrodes, lightning arrestor etc. Capacity/ size-- As per site requirement |
| 20 | B--8 Remote monitoring system, Weather station (Solar irradiation sensor, wind velocity meter, Ambient temperature sensor)Capacity/ size-- |
| 21 | B--9 Bidirectional mete r and Solar Check meter (11 KV) with CT, PT units as per Local Electricity board requirement. Necessary testing & liaison with MSEDCL/ CEIG /MEDA and obtaining approvals are included in the scope of work.Capacity/ size-- As per site requirement |
| 22 | B.10-- Civil works complete – like pile foundation, construction of invertor room, Path way, Putting Gravels grouting of bolts/structural members, breaking of wall /floor slab, cut-outs making, finishing, painting, support etc required for the SPV system is included in the scope of work.Capacity/ size-- |
| 23 | Note-- Please refer the technical specification mention in the Tender documents for detailed list for comprhensive BOQ |